Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Rashba-Zeeman-effect-induced spin filtering energy windows in a quantum wire

We perform a numerical study on the spin-resolved transport in a quantum wire (QW) under the modulation of both Rashba spin-orbit coupling (SOC) and a perpendicular magnetic field by using the developed Usuki transfer-matrix method in combination with the Landauer-Büttiker formalism. Wide spin filtering energy windows can be achieved in this system for unpolarized spin injection. In addition, both the width of energy window and the magnitude of spin conductance within these energy windows can be tuned by varying Rashba SOC strength, which can be apprehended by analyzing the energy dispersions and spin-polarized density distributions inside the QW, respectively. Further study also demonstrates that these Rashba-SOC-controlled spin filtering energy windows show a strong robustness against disorders. These findings may not only benefit to further understand the spin-dependent transport properties of a QW in the presence of external fields but also provide a theoretical instruction to design a spin filter device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrathin metal-semiconductor-metal resonator for angle invariant visible band transmission filters

We present transmission visible wavelength filters based on strong interference behaviors in an ultrathin semiconductor material between two metal layers. The proposed devices were fabricated on 2 cm × 2 cm glass substrate, and the transmission characteristics show good agreement with the design. Due to a significantly reduced light propagation phase change associated with the ultrathin semiconductor layer and the compensation in phase shift of light reflecting from the metal surface, the filters show an angle insensitive performance up to ±70°, thus, addressing one of the key challenges facing the previously reported photonic and plasmonic color filters. This principle, described in this paper, can have potential for diverse applications ranging from color display devices to the image sensors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transport of low pressure electronegative SF{sub 6} plasma through a localized magnetic filter

The generation of an ion-ion plasma where only few electrons are present in the discharge could be appropriated in the context of ion plasma source applications. We present in this paper results obtained with a one-dimensional fluid model in the context of low pressure electronegative SF{sub 6} plasma. Without magnetic field, results show that the electron density is still large in the discharge. With a localized magnetic filter, where the magnetic field strength is such that the transport of the electrons is affected while the transport of ion species remains unmagnetized, we show that a region with a negative–positive ion plasma is found downstream the magnetic filter. The negative ions are produced in the filter due to the decrease of electron temperature. We also find conditions when the plasma sheath near the biased electrode collapses and the negative ion extraction from the plasma becomes possible. In addition, the influence of E × B electron transport on the one-dimensional model results is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Double-sided Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10} thin films based high temperature superconducting filter operating above 100 K

A high temperature superconducting (HTS) filter on double-sided Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10} (Tl-2223) thin films is designed in this letter. High-quality double-sided Tl-2223 thin films are prepared on 10 × 10 × 0.5 mm{sup 3} LaAlO{sub 3} (001) substrate. The critical temperatures T{sub c} of the films are 120 ± 1 K and the critical current densities J{sub c} are 3–4 MA/cm{sup 2} at 77 K for both sides. X-ray diffraction θ-2θ scans and rotational ϕ-scans prove that the films are strongly textured with the c axis perpendicular to the substrate surface. A 3-pole band-pass filter is then fabricated on the Tl-2223 thin films with 4% relative bandwidth and a center frequency of 4.0 GHz. At 77 K, 100 K, and 102 K, the insertion loss in the passband is 0.088 dB, 0.21 dB, and 0.27 dB, respectively. These performances show that the proposed HTS filter is satisfying even when the operating temperature is above 100 K, which makes it possible to work in outer space without cryogenic systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fast wavelength calibration method for spectrometers based on waveguide comb optical filter

A novel fast wavelength calibration method for spectrometers based on a standard spectrometer and a double metal-cladding waveguide comb optical filter (WCOF) is proposed and demonstrated. By using the WCOF device, a wide-spectrum beam is comb-filtered, which is very suitable for spectrometer wavelength calibration. The influence of waveguide filter’s structural parameters and the beam incident angle on the comb absorption peaks’ wavelength and its bandwidth are also discussed. The verification experiments were carried out in the wavelength range of 200–1100 nm with satisfactory results. Comparing with the traditional wavelength calibration method based on discrete sparse atomic emission or absorption lines, the new method has some advantages: sufficient calibration data, high accuracy, short calibration time, fit for produce process, stability, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silicon on-chip bandpass filters for the multiplexing of high sensitivity photonic crystal microcavity biosensors

A method for the dense integration of high sensitivity photonic crystal (PC) waveguide based biosensors is proposed and experimentally demonstrated on a silicon platform. By connecting an additional PC waveguide filter to a PC microcavity sensor in series, a transmission passband is created, containing the resonances of the PC microcavity for sensing purpose. With proper engineering of the passband, multiple high sensitivity PC microcavity sensors can be integrated into microarrays and be interrogated simultaneously between a single input and a single output port. The concept was demonstrated with a 2-channel L55 PC biosensor array containing PC waveguide filters. The experiment showed that the sensors on both channels can be monitored simultaneously from a single output spectrum. Less than 3 dB extra loss for the additional PC waveguide filter is observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Controllable spin polarization and spin filtering in a zigzag silicene nanoribbon

Using non-equilibrium Green's function, we study the spin-dependent electron transport properties in a zigzag silicene nanoribbon. To produce and control spin polarization, it is assumed that two ferromagnetic strips are deposited on the both edges of the silicene nanoribbon and an electric field is perpendicularly applied to the nanoribbon plane. The spin polarization is studied for both parallel and anti-parallel configurations of exchange magnetic fields induced by the ferromagnetic strips. We find that complete spin polarization can take place in the presence of perpendicular electric field for anti-parallel configuration and the nanoribbon can work as a perfect spin filter. The spin direction of transmitted electrons can be easily changed from up to down and vice versa by reversing the electric field direction. For parallel configuration, perfect spin filtering can occur even in the absence of electric field. In this case, the spin direction can be changed by changing the electron energy. Finally, we investigate the effects of nonmagnetic Anderson disorder on spin dependent conductance and find that the perfect spin filtering properties of nanoribbon are destroyed by strong disorder, but the nanoribbon retains these properties in the presence of weak disorder.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hollow core waveguide as mid-infrared laser modal beam filter

A novel method for mid-IR laser beam mode cleaning employing hollow core waveguide as a modal filter element is reported. The influence of the input laser beam quality on fiber optical losses and output beam profile using a hollow core waveguide with 200 μm-bore size was investigated. Our results demonstrate that even when using a laser with a poor spatial profile, there will exist a minimum fiber length that allows transmission of only the Gaussian-like fundamental waveguide mode from the fiber, filtering out all the higher order modes. This essentially single mode output is preserved also when the waveguide is bent to a radius of curvature of 7.5 cm, which demonstrates that laser mode filtering can be realized even if a curved light path is required.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analytically solvable chaotic oscillator based on a first-order filter

A chaotic hybrid dynamical system is introduced and its analytic solution is derived. The system is described as an unstable first order filter subject to occasional switching of a set point according to a feedback rule. The system qualitatively differs from other recently studied solvable chaotic hybrid systems in that the timing of the switching is regulated by an external clock. The chaotic analytic solution is an optimal waveform for communications in noise when a resistor-capacitor-integrate-and-dump filter is used as a receiver. As such, these results provide evidence in support of a recent conjecture that the optimal communication waveform for any stable infinite-impulse response filter is chaotic.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

External modes in quantum dot light emitting diode with filtered optical feedback

This research reports a theoretical investigation on the role of filtered optical feedback (FOF) in the quantum dot light emitting diode (QD-LED). The underlying dynamics is affected by a sidle node, which returns to an elliptical shape when the wetting layer (WL) is neglected. Both filter width and time delay change the appearance of different dynamics (chaotic and mixed mode oscillations, MMOs). The results agree with the experimental observations. Here, the fixed point analysis for QDs was done for the first time. For QD-LED with FOF, the system transits from the coherence collapse case in conventional optical feedback to a coherent case with a filtered mode in FOF. It was found that the WL washes out the modes which is an unexpected result. This may attributed to the longer capture time of WL compared with that between QD states. Thus, WL reduces the chaotic behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Short spatial filters with spherical lenses for high-power pulsed lasers

We report possible employment of short spatial filters based on spherical lenses in a pulsed laser source (neodymium glass, 300 J, 1 ns). The influence of the spherical aberration on the quality of output radiation and coefficient of conversion to the second harmonics is studied. The ultra-short aberration spatial filter of length 1.9 m with an aperture of 122 mm is experimentally tested. A considerable shortening of multi-cascade pump lasers for modern petawatt laser systems is demonstrated by the employment of short spatial filters without expensive aspherical optics. (elements of laser systems)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tunable semiconductor laser with two acousto-optic tunable filters in its external cavity

We report a laser with a linear external cavity containing a near-IR injection semiconductor optical amplifier as a gain element and two acousto-optic tunable filters (AOTFs) with quasi-collinear interaction of acoustic and light waves. At identical frequencies of RF signals that control the filters and ensure compensation for the Doppler frequency shift of light passing through the AOTFs, the steady-state laser emission linewidth can be reduced to about 25 MHz, which is almost three orders of magnitude smaller than that in the case of one filter (20 GHz). The position of the emission line, which remains narrow, slowly fluctuates within a spectral range about 3 GHz wide, which seems to be due to the large length of the external cavity and insufficient thermal stabilization of its components. This does not prevent us from obtaining light with a large coherence length. In emission wavelength sweep mode, the instantaneous emission linewidth increases with tuning rate, reaching 0.022 nm (8.8 GHz) at the highest tuning rate: 10{sup 4} nm s{sup −1}. In the case of automatic control over the output optical power at a level of 3 mW, the tuning range is 815 – 875 nm. Such instruments are of practical interest for optical coherence tomography, spectroscopy, optical metrology, and other application areas. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-threshold, single-transverse-mode, 940-nm vertical-cavity surface-emitting laser with a mode filter and half-wavelength cavity

We demonstrate a structure for a vertical-cavity surface-emitting laser (VCSEL) with a mode filter and half-wavelength (λ/2) cavity. The effects of λ/2- and λ-cavities on the threshold current are studied. The thickness and etched diameter of the mode filter are optimised to achieve single-transverse-mode output. The results show that when changing from λ-cavity to λ/2-cavity, the threshold current of the VCSEL decreases by 30.7% (from 0.85 mA to 0.65 mA). In addition, for the mode-filter thickness of 80 nm, and the etched diameter of 2.5 μm, the side mode suppression ratio reaches 90 dB, which meets the requirement of single-transverse-mode output. The VCSELs with the optimised design can overcome many difficulties and have great potential in 3D face recognition. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STUDIES OF NGC 6720 WITH CALIBRATED HST/WFC3 EMISSION-LINE FILTER IMAGES. I. STRUCTURE AND EVOLUTION ,

We have performed a detailed analysis of the Ring Nebula (NGC 6720) using Hubble Space Telescope WFC3 images and derived a new three-dimensional model. Existing high spectral resolution spectra played an important supplementary role in our modeling. It is shown that the Main Ring of the nebula is an ionization-bounded irregular non-symmetric disk with a central cavity and perpendicular extended lobes pointed almost toward the observer. The faint outer halos are determined to be fossil radiation, i.e., radiation from gas ionized in an earlier stage of the nebula when it was not ionization bounded. The narrowband WFC3 filters that isolate some of the emission lines are affected by broadening on their short wavelength side and all the filters were calibrated using ground-based spectra. The filter calibration results are presented in an appendix.

79 ASTRONOMY AND ASTROPHYSICS↗

ENHANCING CORONAL STRUCTURES WITH THE FOURIER NORMALIZING-RADIAL-GRADED FILTER

Images of the corona have a high dynamic range which is excellent for quantitative photometric analysis. To understand the processes governing the solar corona, it is essential to have information about the absolute brightness as well as the underlying structure. However, due to the steep radial gradient of brightness in the images, and to the fact that structures closer to the solar disk have higher contrast than structures further from the disk, human vision cannot view the intricate structure of the corona in such images. The recently developed normalizing-radial-graded filter (NRGF) is an effective way for revealing the coronal structure. In this work, we present a more adaptive filter inspired by the NRGF, which we call the Fourier normalizing-radial-graded filter (FNRGF). It approximates the local average and the local standard deviation by a finite Fourier series. This method enables the enhancement of finer details, especially in regions of lower contrast. We also show how the influence of additive noise is reduced by a modification to the FNRGF. To illustrate the power of the method, the FNRGF is applied to images of emission from coronal forbidden lines observed during the 2010 July 11 total solar eclipse. It is also successfully applied to space-based observations of the low corona in the extreme ultraviolet and to white light coronagraph observations, thus demonstrating the validity of the FNRGF as a new tool that will help the interpretation of the information embedded in most types of coronal images.

79 ASTRONOMY AND ASTROPHYSICS↗

State-selective detection of velocity-filtered ND{sub 3} molecules

Translationally cold and slow ND{sub 3} is prepared by filtering the slow molecules from a thermal gas-phase sample using a curved electrostatic hexapole guide. This filter, like the curved quadrupole guide introduced by Rangwala et al. [Phys. Rev. A 67, 043406 (2003)] selects molecules by their forward velocity and effective electric dipole moment. Here we describe two main modifications with respect to previous work: (1) A segmented hexapole guide is used that produces a harmonic potential for the linearly Stark-shifted levels of ND{sub 3}. A curved guide is combined with a straight hexapole guide, and independent high-voltage supplies are employed to allow for bandpass velocity filtering. (2) State-selective laser ionization is used to obtain time- and state-selective detection of the guided molecules. This enables the experimental determination of the rotational state population of the guided molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optimal configurations of filter cavity in future gravitational-wave detectors

Sensitivity of future laser interferometric gravitational wave detectors can be improved using squeezed light with frequency-dependent squeeze angle and/or amplitude, which can be created using additional so-called filter cavities. Here we compare performances of several variants of this scheme, proposed during the last few years, assuming the case of a single relatively short (tens of meters) filter cavity suitable for implementation already during the life cycle of the second-generation detectors, like Advanced LIGO. Using numerical optimization, we show that the phase filtering scheme proposed by Kimble et al [H. J. Kimble, Yu. Levin, A. B. Matsko, K. S. Thorne, and S. P. Vyatchanin, Phys. Rev. D 65, 022002 (2001).] looks like the best candidate for this scenario.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimum filter-based discrimination of neutrons and gamma rays

An optimum filter-based method for discrimination of neutrons and gamma-rays in a mixed radiation field is presented. The existing filter-based implementations of discriminators require sample pulse responses in advance of the experiment run to build the filter coefficients, which makes them less practical. Our novel technique creates the coefficients during the experiment and improves their quality gradually. Applied to several sets of mixed neutron and photon signals obtained through different digitizers using stilbene scintillator, this approach is analyzed and its discrimination quality is measured. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗