Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

The Cost of Decarbonization and Energy Upgrade Retrofits for US Homes

Cost is a major barrier when upgrading homes to reduce carbon emissions required to meet DOE’s climate-related goals. This report summarizes a nationwide effort to gather home energy upgrade project cost data along with household energy performance data. The goal was to develop cost benchmarks and to guide future R&D efforts aimed at cost compression and scaling of the residential upgrade market. The cost data were compiled for both total project costs and costs of individual measures. The majority of energy savings were modeled, with some models using measured site data for calibration. The database was analyzed using clustering techniques to find common energy and CO2 reduction approaches. The individual measures were combined into archetypal solutions to determine least-cost approaches to maximizing energy and carbon savings. Several financial analyses were preformed to examine other cost metrics beyond first cost. Project data was obtained for 1,739 projects, from 15 states and 12 energy programs, with a total of 10,512 individual measures. The database includes a wide-array of projects, ranging from single-measure HVAC upgrades to net-zero energy whole home remodels. Projects were predominantly single-family detached dwellings with wood frame construction. Most of the data was obtained from energy programs because they had recorded the necessary information and were willing to share with this study. This sample of convenience can provide broad guidance and national cost benchmarks, but lacks sufficient detail to draw more disaggregated conclusions, such as geographical trends. The majority of data contributions were obtained without compensation from sources where the required data was already in some sort of structured format. We compensated sources to enter data from individual projects into a structured data format for about 500 projects, with an average cost of about $40 per project. The database was highly skewed to lower cost, lower impact projects due to the nature of the sample of convenience. Less than 10% of projects had savings greater than 50%. The cost data for individual measures in the database are being used in other DOE efforts on residential energy use/decarbonization. This data collection effort should continue in order to provide the best-informed guidance for DOE and industry R&D, as well as deployment efforts (including policy and program planning).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

On the localness of the spectral energy transfer in turbulence

Data for the energy transfer function are used to estimate the degree of localness of energy transfer in homogeneous turbulence. It is found that in regions where the energy which enters a wavenumber band is greater than the energy leaving, much of the energy entering the band is produced by wavenumbers an order of magnitude smaller. Thus for both low and high Reynolds numbers, spectral energy transfer is nonlocal. The tendency of the energy to jump between separated wavenumber regions agrees with the theory that turbulence forms concentrated regions of large velocity gradients. It is also felt that the universal equilibrium theory may be applicable if the Reynolds number of the turbulence is very high.

Deissler, R. G.↗

An Update on the Geothermal Data Repository's Data Standards and Pipelines: Geospatial Data and Distributed Acoustic Sensing Data

The Department of Energy's (DOE) Geothermal Data Repository (GDR) team has implemented data standards and automated data pipelines for the following data types: 1) drilling data, 2) geospatial datasets, and 3) DAS data. An additional data pipeline is proposed for stimulation data. These data standards and pipelines are intended to improve the real-world applicability of geothermal machine learning outputs through improving the quality of data. More specifically, through standardizing high-value datasets, the GDR is reducing project-specific data curation requirements, allowing more time to be spent on actual research. By automating this process, the burden of standardization is taken off of the user, overall increasing the availability of standardized data. This paper provides an update on the GDR's transition toward data standardization through automated data pipelines and calls for feedback from the community on how we can improve this process.

cloud-optimized↗

Fast 2D Bicephalous Convolutional Autoencoder for Compressing 3D Time Projection Chamber Data

High-energy large-scale particle colliders produce data at high speed in the order of 1 terabytes per second in nuclear physics and petabytes per second in high energy physics. Developing real-time data compression algorithms to reduce such data at high throughput to fit permanent storage has drawn increasing attention. Specifically, at the newly constructed sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC), a time projection chamber is used as the main tracking detector, which records particle trajectories in a volume of three-dimensional (3D) cylinder. The resulting data are usually very sparse with occupancy around 10.8%. Such sparsity presents a challenge to conventional learning-free lossy compression algorithms, such as SZ, ZFP, and MGARD. The 3D convolutional neural network (CNN)-based approach, Bicephalous Convolutional Autoencoder (BCAE), outperforms traditional methods both in compression rate and reconstruction accuracy. BCAE can also utilize the computation power of graphical processing units suitable for deployment in a modern heterogeneous highperformance computing environment. This work introduces two BCAE variants: BCAE++ and BCAE-2D. BCAE++ achieves a 15% better compression ratio and a 77% better reconstruction accuracy measured in mean absolute error compared with BCAE. BCAE-2D treats the radial direction as the channel dimension of an image, resulting in a 3× speedup in compression throughput. In addition, we demonstrate an unbalanced autoencoder with a larger decoder can improve reconstruction accuracy without significantly sacrificing throughput. Lastly, we observe both the BCAE++ and BCAE-2D can benefit more from using half-precision mode in throughput (76 - 79% increase) without loss in reconstruction accuracy. The source code and links to data and pretrained models can be found at https://github.com/BNL-DAQ-LDRD/NeuralCompression_v2

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Designing Energy-Efficient Quantum Computers Through Prediction and Reduction of Cooling Requirements for Cryogenic Electronics

Quantum computing has been identified as a “wild card” by the International Energy Agency in predicting future global data center energy usage. This is primarily because both uncertainty in the extent to which quantum computing will be adopted, and uncertainty in the power consumption of individual quantum data centers. Unlike the classical counterparts, quantum computers need to be maintained at near absolute zero, requiring energy-intensive cryogenic cooling systems. Therefore, as quantum computers scale up from existing 50 qubit technology demonstrations to the 10,000 to 100,000 qubit systems that will be able to solve complex problems, the energy consumption of both the electronics and the required cooling systems will also increase. To predict this scaling, this work analyzes the energy requirements for both computation and cooling of quantum hardware. We show that the energy requirements for cooling of quantum computers is determined by several computing system parameters, including the number and type of physical qubits, the operating temperature, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. The energy requirements can then be found based on thermal system parameters such as cooling efficiency and cryostat heat transfer. Analysis of these parameters shows that the energy required for cooling is significantly larger than that required for computation, a reversal from energy usage patterns seen in conventional computing. The results and discussions provide a road-map for creating energy efficient quantum computers through the selection of computer architectures and cryogenic system configurations that minimize cooling requirements.

energy efficiency↗

PNNL streamlines energy-guzzling computers

In a room the size of a garage, two rows of six-foot-tall racks holding supercomputer hard drives sit back-to-back. Thin tubes and wires snake off the hard drives, slithering into the corners. Stepping between the rows, a rush of heat whips around you -- the air from fans blowing off processing heat. But walk farther in, between the next racks of hard drives, and the temperature drops noticeably. These drives are being cooled by a non-conducting liquid that runs right over the hardworking processors. The liquid carries the heat away in tubes, saving the air a few degrees. This is the Energy Smart Data Center at Pacific Northwest National Laboratory. The bigger, faster, and meatier supercomputers get, the more energy they consume. PNNL's Andres Marquez has developed this test bed to learn how to train the behemoths in energy efficiency. The work will help supercomputers perform better as well. Processors have to keep cool or suffer from "thermal throttling," says Marquez. "That's the performance threshold where the computer is too hot to run well. That threshold is an industry secret." The center at EMSL, DOE's national scientific user facility at PNNL, harbors several ways of experimenting with energy usage. For example, the room's air conditioning is isolated from the rest of EMSL -- pipes running beneath the floor carry temperature-controlled water through heat exchangers to cooling towers outside. "We can test whether it's more energy efficient to cool directly on the processing chips or out in the water tower," says Marquez. The hard drives feed energy and temperature data to a network server running specially designed software that controls and monitors the data center. To test the center’s limits, the team runs the processors flat out – not only on carefully controlled test programs in the Energy Smart computers, but also on real world software from other EMSL research, such as regional weather forecasting models. Marquez's group is also developing "power aware computing", where the computer programs themselves perform calculations more energy efficiently. Maybe once computers get smart about energy, they'll have tips for their users.

data center↗

Linear systematics mitigation in galaxy clustering in the Dark Energy Survey Year 1 Data

ABSTRACT We implement a linear model for mitigating the effect of observing conditions and other sources of contamination in galaxy clustering analyses. Our treatment improves upon the fiducial systematics treatment of the Dark Energy Survey (DES) Year 1 (Y1) cosmology analysis in four crucial ways. Specifically, our treatment (1) does not require decisions as to which observable systematics are significant and which are not, allowing for the possibility of multiple maps adding coherently to give rise to significant bias even if no single map leads to a significant bias by itself, (2) characterizes both the statistical and systematic uncertainty in our mitigation procedure, allowing us to propagate said uncertainties into the reported cosmological constraints, (3) explicitly exploits the full spatial structure of the galaxy density field to differentiate between cosmology-sourced and systematics-sourced fluctuations within the galaxy density field, and (4) is fully automated, and can therefore be trivially applied to any data set. The updated correlation function for the DES Y1 redMaGiC catalogue minimally impacts the cosmological posteriors from that analysis. Encouragingly, our analysis does improve the goodness-of-fit statistic of the DES Y1 3 × 2pt data set (Δχ2 = −6.5 with no additional parameters). This improvement is due in nearly equal parts to both the change in the correlation function and the added statistical and systematic uncertainties associated with our method. We expect the difference in mitigation techniques to become more important in future work as the size of cosmological data sets grows.

79 ASTRONOMY AND ASTROPHYSICS↗

Facility Energy Saving and Securing Technology Using Multi-Source Data (FEST) (Final Report)

Facility Energy Saving and Securing Technology (FEST) project focuses on developing algorithmic tools and techniques for analyzing cyber-physical security of DoD’s military site facilities, and optimal scheduling, operation and planning of their Distributed Energy Resources (DER). The project is led by LLNL with the team including University of Michigan-Dearborn and XENDEE. The military site partner providing the energy metering data is White Sands Missile Range (WSMR). This report summarizes the work performed during the project and future directions for follow-on research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DOE Commercial Building Asset Rating: An Application of Centralized Modeling Tools

This paper presents a novel approach used to develop the U.S. Department of Energy (DOE) Commercial Building Asset Rating, which is intended to help building owners better understand the installed system performance and the total energy use. A simplified data collection and energy-modeling method is employed to disaggregate building energy information. Furthermore, the approach outlined will also include a mechanism for identifying energy improvement opportunities. A detailed modeling approach to formulate an Asset Rating would most likely provide the greatest flexibility and accuracy. Such an approach would, however, require a substantial amount of user investment for collecting the energy audit, data and hiring a professional to perform energy modeling and analysis. A simplified model approach requires fewer input combinations, which could reduce opportunities for error and allow an inexperienced user to quickly develop energy models. However, the accuracy of the results is often questionable. To address the above issue, the method presented in this paper separates model inputs into categories based on overall energy impact, difficulty to obtain, and variability among buildings. We outline an approach that will allow great flexibility in terms of how many and which of the different categories of variables must be found to produce an accurate energy model. The approach will allow all key variables to be inferred from some minimum set of variables while at the same time allowing a user to enter many more variables if he or she has reliable values for them. The approach outlined will also provide constant values for some variables and algorithms for finding those which are very difficult to determine in the field. The whole of this approach will reduce modeling time and expertise required while maintaining accuracy and the ability to support the variability and complexity that exist in buildings. Therefore, the goals of facilitating cost-effective investment in energy efficiency and reducing energy use in the commercial building sector are met.

Asset Rating↗

Multi-facility analysis using metered power data to quantify MRI energy use and utility bill costs across scanner operating modes

This study quantifies the energy consumption of magnetic resonance imaging (MRI) scanners across discrete operating modes during routine clinical workflows, based solely on electrical power measurements. Although previous studies have investigated MRI energy consumption within single hospitals or specific clinical settings, this research provides a broader and more systematic analysis. Researchers analyzed electrical power data and applied a previously developed semi-automatic method for identifying MRI operating modes using load duration curves for 20 MRI scanners across four different U.S. healthcare facilities, encompassing outpatient, inpatient, and mixed-use clinical settings. A key innovation is the inclusion of localized hourly utility rates to estimate costs, a parameter absent in prior literature. Key findings indicate significant variability in energy and cost profiles between weekdays and weekends. Scanner characteristics, including magnet strength, manufacturer, vintage, location, and clinical setting, influenced average daily energy consumption and power thresholds for operating modes. Notably, the clinical setting of a scanner predominantly determines its energy use. For example, the scanners in outpatient facilities consumed more energy. The breakdown of energy usage and costs by operating modes showed scanners spend between 61% and 93% of their time in nonproductive modes, with one outlier spending 34%. Average daily energy use for the scanners in the study ranged from 160 to 1069 kWh, with energy costs ranging from $\$$9 to $\$$149. This study uses an existing framework to quantify MRI energy behavior, leading to insights that can enable improved performance and cost savings across different healthcare environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NEW STRONG-LINE ABUNDANCE DIAGNOSTICS FOR H II REGIONS: EFFECTS OF κ-DISTRIBUTED ELECTRON ENERGIES AND NEW ATOMIC DATA

Recently, Nicholls et al., inspired by in situ observations of solar system astrophysical plasmas, suggested that the electrons in H II regions are characterized by a κ-distribution of energies rather than a simple Maxwell-Boltzmann distribution. Here, we have collected together new atomic data within a modified photoionization code to explore the effects of both the new atomic data and the κ-distribution on the strong-line techniques used to determine chemical abundances in H II regions. By comparing the recombination temperatures (T {sub rec}) with the forbidden line temperatures (T {sub FL}), we conclude that κ ∼ 20. While representing only a mild deviation from equilibrium, this result is sufficient to strongly influence abundances determined using methods that depend on measurements of the electron temperature from forbidden lines. We present a number of new emission line ratio diagnostics that cleanly separate the two parameters determining the optical spectrum of H II regions—the ionization parameter q or U and the chemical abundance, 12+log(O/H). An automated code to extract these parameters is presented. Using the homogeneous data set from van Zee et al., we find self-consistent results between all of these different diagnostics. The systematic errors between different line ratio diagnostics are much smaller than those found in the earlier strong-line work. Overall, the effect of the κ-distribution on the strong-line abundances derived solely on the basis of theoretical models is rather small.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrated SOAs enable energy-efficient intra-data center coherent links

Coherent optical links are becoming increasingly attractive for intra-data center applications as data rates scale. Realizing the era of high-volume short-reach coherent links will require substantial improvements in transceiver cost and power efficiency, necessitating a reassessment of conventional architectures best-suited for longer-reach links and a review of assumptions for shorter-reach implementations. In this work, we analyze the impact of integrated semiconductor optical amplifiers (SOAs) on link performance and power consumption, and describe the optimal design spaces for low-cost and energy-efficient coherent links. Placing SOAs after the modulator provide the most energy-efficient link budget improvement, up to 6 pJ/bit for large link budgets, despite any penalties from nonlinear impairments. Increased robustness to SOA nonlinearities makes QPSK-based coherent links especially attractive, and larger supported link budgets enable the inclusion of optical switches, which could revolutionize data center networks and improve overall energy efficiency.

Maharry, Aaron (ORCID:0000000273732697)↗

Evolution of Galaxy Luminosity and Stellar-Mass Functions since $z=1$ with the Dark Energy Survey Science Verification Data

We present the first study of the evolution of the galaxy luminosity and stellar-mass functions (GLF and GSMF) carried out by the Dark Energy Survey (DES). We describe the COMMODORE galaxy catalogue selected from Science Verification images. This catalogue is made of $\sim 4\times 10^{6}$ galaxies at $0<z\lesssim1.3$ over a sky area of $\sim155\ {\rm sq. \ deg}$ with ${\it i}$-band limiting magnitude ${\it i}=23\ {\rm mag}$. Such characteristics are unprecedented for galaxy catalogues and they enable us to study the evolution of GLF and GSMF at $0<z<1$ homogeneously with the same statistically-rich data-set and free of cosmic variance effects. The aim of this study is twofold: i) we want to test our method based on the use of photometric-redshift probability density functions against literature results obtained with spectroscopic redshifts; ii) we want to shed light on the way galaxies build up their masses over cosmic time. We find that both the ${\it i}$-band galaxy luminosity and stellar mass functions are characterised by a double-Schechter shape at $z<0.2$. Both functions agree well with those based on spectroscopic redshifts. The DES GSMF agrees especially with those measured for the GAlaxy Mass Assembly and the PRism MUlti-object Survey out to $z\sim1$. At $0.2<z<1$, we find the ${\it i}$-band luminosity and stellar-mass densities respectively to be constant ($\rho_{\rm L}\propto (1+z)^{-0.12\pm0.11}$) and decreasing ($\rho_{\rm Mstar}\propto (1+z)^{-0.5\pm0.1}$) with $z$. This indicates that, while at higher redshift galaxies have less stellar mass, their luminosities do not change substantially because of their younger and brighter stellar populations. Finally, we also find evidence for a top-down mass-dependent evolution of the GSMF.

79 ASTRONOMY AND ASTROPHYSICS↗

Broad absorption line quasars in the Dark Energy Spectroscopic Instrument Early Data Release

Broad absorption line (BAL) quasars are characterized by gas clouds that absorb flux at the wavelength of common quasar spectral features, although blueshifted by velocities that can exceed $0.1c$. BAL features are interesting as signatures of significant feedback, yet they can also compromise cosmological studies with quasars by distorting the shape of the most prominent quasar emission lines, impacting redshift accuracy and measurements of the matter density distribution traced by the Lyman $\alpha$ forest. We present a catalogue of BAL quasars discovered in the Dark Energy Spectroscopic Instrument (DESI) survey Early Data Release, which were observed as part of DESI Survey Validation, as well as the first two months of the main survey. We describe our method to automatically identify BAL quasars in DESI data, the quantities we measure for each BAL, and investigate the completeness and purity of this method with mock DESI observations. We mask the wavelengths of the BAL features and re-evaluate each BAL quasar redshift, finding new redshifts which are $243\, {\rm km}\, {\rm s}^{-1}$ smaller on average for the BAL quasar sample. These new, more accurate redshifts are important to obtain the best measurements of quasar clustering, especially at small scales. Finally, we present some spectra of rarer classes of BALs that illustrate the potential of DESI data to identify such populations for further study.

79 ASTRONOMY AND ASTROPHYSICS↗

Scaled MP3 Non-Covalent Interaction Energies Agree Closely with Accurate CCSD(T) Benchmark Data

Scaled MP3 interaction energies calculated as a sum of MP2/CBS (complete basis set limit) interaction energies and scaled thirdorder energy contributions obtained in small or medium size basis sets agree very closely with the estimated CCSD(T)/CBS interaction energies for the 22 H-bonded, dispersion-controlled and mixed non-covalent complexes from the S22 data set. Performance of this so-called MP2.5 (third-order scaling factor of 0.5) method has also been tested for 33 nucleic acid base pairs and two stacked conformers of porphine dimer. In all the test cases, performance of the MP2.5 method was shown to be superior to the scaled spin-component MP2 based methods, e.g. SCS–MP2, SCSN–MP2 and SCS(MI)–MP2. In particular, a very balanced treatment of hydrogen-bonded compared to stacked complexes is achieved with MP2.5. The main advantage of the approach is that it employs only a single empirical parameter and is thus biased by two rigorously defined, asymptotically correct ab-initio methods, MP2 and MP3. The method is proposed as an accurate but computationally feasible alternative to CCSD(T) for the computation of the properties of various kinds of non-covalently bound systems.

59 BASIC BIOLOGICAL SCIENCES↗

Prototype College Building Energy Model: Building Characteristics and Energy Simulation Results

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 16 prototype building models, which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype college building, and a 4-story with 69,063 ft 2 building was considered as the prototype college building to represent an average-sized college building in the United States. To represent realistic occupancy schedules and increase the granularity of information, actual class reservation schedules were collected and used. This report documents the building and system characteristics of the prototype college building model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. The site energy use intensity of the college building was compared with 2012 Commercial Building Energy Consumption Survey (CBECS) and ENERGY STAR data to verify the simulation results. The site energy use intensity of the college building ranged from 60 to 202.4 kBtu/ft 2 , and compared with the energy use intensities of Commercial Building Energy Consumption Survey (122.9 kBtu/ft 2 ) and ENERGY STAR (84.3 kBtu/ft 2 ) data, the prototype college building results are in a reasonable range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Next-Level Energy Management in Manufacturing: Facility-Level Energy Digital Twin Framework Based on Machine Learning and Automated Data Collection

This research introduces an energy prediction framework at the facility level supported by automated data collection and machine learning models. It investigates whether reducing the prediction time scale allows for applying more complex machine learning techniques and if those techniques improve the prediction accuracy. The primary advantages of this framework lie in its automation of the energy prediction process and its provision of real-time energy data suitable for use in energy dashboards or digital twins. A sitewide dataset was created by combining 15 min energy and daily production data of five shops—assembly, battery, body (electric), body (gas), and paint—from a globally recognized electric vehicle manufacturer. Various machine learning models were evaluated on daily, weekly, and monthly datasets, including, in increasingly complex order: naïve, simple linear regression, net regularized generalized linear regression, principal component regression, k-nearest neighbor, random forest, and Bayesian regularized neural network. Compared to the current state-of-the-art energy consumption prediction for the industrial facility level, this research investigates more complex models and smaller time intervals for higher accuracy. The findings revealed that the more complex monthly models require a minimum of a year and a half of data to operate, while weekly models demand a year of data to achieve improved accuracy. Daily models can operate with only six months of data but exhibit poor performance due to reduced prediction accuracy of production. Key challenges identified include access to reliable, high-quality energy and production data and the initial demand for human labor.

digital twin↗

PV Inverter Availability from the U.S. PV Fleet

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data, and publish aggregated, anonymized results. An assessment of system availability is conducted on 1128 systems which passed our data quality checks, and include cumulative energy meter data. Overall inverter availability is low in the first 6 months of system performance before reaching steady-state by the end of the first year. System-level aggregated data shows a median (P50) system availability of 0.99, and a lower P90 value of 0.95. A dependence on system size is also identified, with better inverter availability results for smaller PV systems. Potential causes of this effect may include the selection of inverter itself: smaller inverters 6kW-250kW showed better average availability than inverters 300kW-5MW. The elimination of string combiner boxes and lower energy impact when one particular inverter goes off-line are potential benefits of a string inverter-based PV system architecture. DNV also analyzed availability data from over 1100 operating systems and found similar trends. DNV's P50 industry guidance on expected availability has been updated to reflect the data and the following observations: utility scale systems have lower availability than DG systems, availability is lower in first year compared to subsequent years, and that actual availability is lower than expected.

fleet↗