Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy - Conversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Money for Research, Not for Energy Bills: Finding Energy and Cost Savings in High Performance Computer Facility Designs

High-performance computing facilities in the United States consume an enormous amount of electricity, cutting into research budgets and challenging public- and private-sector efforts to reduce energy consumption and meet environmental goals. However, these facilities can greatly reduce their energy demand through energy-efficient design of the facility itself. Using a case study of a facility under design, this article discusses strategies and technologies that can be used to help achieve energy reductions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy 101: Energy Efficient Commercial Buildings

Learn how commercial buildings can incorporate whole-building design to save energy and money while enhancing performance and comfort. This video highlights several energy-saving features of the Research Support Facility at the Energy Department's National Renewable Energy Laboratory-a model for high-performance office building design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency and Renewable Energy for New Home Construction in Maui

For residential property owners preparing to rebuild homes in Maui, this fact sheet, produced by the National Renewable Energy Laboratory (NREL), a national laboratory of the U.S. Department of Energy (DOE), provides a brief introduction to the topics of renewable energy and energy efficiency for new residential construction, presents a few high-level considerations and key concepts, and provides a sampling of information on rebates, incentives, certification programs, standards, and relevant policies. This fact sheet is not intended to be comprehensive nor to replace local resources.

appliances↗

Life Cycle Assessment of Thermal Energy Storage: Two-Tank Indirect and Thermocline

In the United States, concentrating solar power (CSP) is one of the most promising renewable energy (RE) technologies for reduction of electric sector greenhouse gas (GHG) emissions and for rapid capacity expansion. It is also one of the most price-competitive RE technologies, thanks in large measure to decades of field experience and consistent improvements in design. One of the key design features that makes CSP more attractive than many other RE technologies, like solar photovoltaics and wind, is the potential for including relatively low-cost and efficient thermal energy storage (TES), which can smooth the daily fluctuation of electricity production and extend its duration into the evening peak hours or longer. Because operational environmental burdens are typically small for RE technologies, life cycle assessment (LCA) is recognized as the most appropriate analytical approach for determining their environmental impacts of these technologies, including CSP. An LCA accounts for impacts from all stages in the development, operation, and decommissioning of a CSP plant, including such upstream stages as the extraction of raw materials used in system components, manufacturing of those components, and construction of the plant. The National Renewable Energy Laboratory (NREL) is undertaking an LCA of modern CSP plants, starting with those of parabolic trough design.

14 SOLAR ENERGY↗

Techno-economic analysis of long-duration energy storage and flexible power generation technologies to support high-variable renewable energy grids

As variable renewable energy penetration increases beyond 80%, clean power systems will require long-duration energy storage or flexible, low-carbon generation. Here, we provide a detailed techno-economic evaluation and uncertainty analysis of applicable technologies and identify challenges and opportunities to support electric grid planning. We show that for a 120-h storage duration rating, hydrogen systems with geologic storage and natural gas with carbon capture are the least-cost low-carbon technologies for both current and future capital costs. These results are robust to uncertainty for the future capital cost scenario, but adiabatic compressed air and pumped thermal storage could be the least-cost technologies in the current capital cost scenario under uncertainty. Finally, we present a new storage system using heavy-duty vehicle fuel cells that could reduce the levelized cost of energy by 13%–20% compared with the best previously considered storage technology and, thus, could help enable very high (>80%) renewable energy grids.

25 ENERGY STORAGE↗

From TPL assessment to design optimization: Wave energy converter control co-design applied to the RM3

The Reference Model (RM) project developed six marine energy converter concepts using a sequential design methodology, which, while widely adopted in the industry, often overlooks interactions between system components, resulting in suboptimal designs. One such example is the Reference Model 3 (RM3), a two-body point absorber wave energy converter (WEC). An assessment using the Technology Performance Level (TPL) revealed that RM3’s low power-to-cost ratio, partly due to expensive steel construction, limits its techno-economic performance. Here, this study aims to redesign RM3 by reducing its scale and employing control co-design to integrate WEC and Power Take-Off (PTO) dynamics, constraints, and cost considerations within an optimization framework. We demonstrate the limitations of RM3’s current PTO design and explore the benefits of scaling down to enhance techno-economic viability by lowering material costs. Using WecOptTool, we conduct a parameter sweep over gear ratios and spring stiffnesses for various Commercial Off-The-Shelf generators in irregular wave conditions. Our findings emphasize the importance of aligning PTO components with WEC dynamics, showing that control co-design and strategic scaling can improve RM3’s power-to-cost ratio. This study presents a transferable example of applied control co-design for other WECs, supporting early-stage developers in their design decisions.

Off the shelf components↗

Multifaceted drivers for onshore wind energy repowering and their implications for energy transition

Wind energy is anticipated to become a backbone of the future energy system. Ageing wind turbine fleets, increasing land-use constraints and rising relevance of societal factors make the deployment of land-based (onshore) wind energy ever more complicated. Consequently, repowering is expected to become a rapidly growing point of focus for the wind industry. Here we propose a more holistic and socially informed project-level approach to analyse repowering activity that enables a more robust understanding of the process and potentials. We demonstrate that for wind pioneer in Denmark, only 67% of the capacity removed in repowering projects was related to the physical space needed for a new turbine. Other factors that drive repowering include regulation (for example, noise-related, 8–17%), development principles (for example, aesthetics, 7–20%) and political bargaining (4–13%). The recognition of repowering as a negotiated process between host communities and wind developers will probably be critical to unlock the full potential of wind energy in the future.

17 WIND ENERGY↗

Non-empirical Nuclear Energy Functionals, Pairing Gaps and Odd-Even Mass Differences

First, we briefly outline some aspects of the starting project to design non-empirical energy functionals based on low-momentum vacuum interactions and many-body perturbation theory. Second, we present results obtained within an approximation of such a scheme where the pairing part of the energy density functional is constructed at first order in the nuclear plus Coulomb two-body interaction. We discuss in detail the physics of the odd-even mass staggering and the necessity to compute actual odd-even mass differences to analyze it meaningfully.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rovibrational energy transfer in the He-C{sub 3} collision: Potential energy surface and bound states

We present a four-dimensional potential energy surface (PES) for the collision of C{sub 3} with He. Ab initio calculations were carried out at the coupled-cluster level with single and double excitations and a perturbative treatment of triple excitations, using a quadruple-zeta basis set and mid-bond functions. The global minimum of the potential energy is found to be −26.9 cm{sup −1} and corresponds to an almost T-shaped structure of the van der Waals complex along with a slightly bent configuration of C{sub 3}. This PES is used to determine the rovibrational energy levels of the He-C{sub 3} complex using the rigid monomer approximation (RMA) and the recently developed atom-rigid bender approach at the Close Coupling level (RB-CC). The calculated dissociation energies are −9.56 cm{sup −1} and −9.73 cm{sup −1}, respectively at the RMA and RB-CC levels. This is the first theoretical prediction of the bound levels of the He-C{sub 3} complex with the bending motion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy Spectrum of Ultrahigh-Energy Cosmic Rays across Declinations -90° to +44.8° as Measured at the Pierre Auger Observatory

The energy spectrum of cosmic rays above 2.5 EeV has been measured across the declination range - 9 0 ° ≤ δ ≤ + 44.8 ° using ∼ 310 000 events accrued at the Pierre Auger Observatory from an exposure of ( 104 900 ± 3 100 ) km 2 sr yr . No significant variations of energy spectra with declination are observed, after allowing or not for nonuniformities across the sky arising from the well-established dipolar anisotropies in the arrival directions of ultrahigh-energy cosmic rays. Here, the instep feature in the spectrum at ≃ 10 EeV reported previously is now established at a significance above 5 σ . Within the statistics, the energy spectra are indistinguishable across declinations so disfavoring an origin for the instep from a few distinctive sources.

Abdul Halim, A. [University of Adelaide]↗

Changes in the Zero-Point Energy of the Protons as the Source of the Binding Energy of Water to A-Phase DNA

The measured changes in the zero-point kinetic energy of the protons are entirely responsible for the binding energy of water molecules to A phase DNA at the concentration of 6 water molecules/base pair. The changes in kinetic energy can be expected to be a significant contribution to the energy balance in intracellular biological processes and the properties of nano-confined water. The shape of the momentum distribution in the dehydrated A phase is consistent with coherent delocalization of some of the protons in a double well potential, with a separation of the wells of 0.2 Angst .

74 ATOMIC AND MOLECULAR PHYSICS↗

Modeling and Assessment of Integrated Hydroelectric Power and Hydrogen Energy Storage

Environmental and regulatory constraints are increasingly posing challenges to the optimal operation of hydroelectric facilities. Hydrogen energy storage (HES) is well-suited to address these challenges.Using excess or low-cost hydroelectric power during off-peak hours to produce hydrogen can help reduce water spills and unlock opportunities for energy arbitrage. Moreover, the oxygen byproduct of electrolysis can be used to improve the dissolved oxygen (DO) levels in tailrace water. %, a key water quality metric for hydroelectric facilities.This paper presents an innovative framework for modeling and assessing the integrated hydroelectric-hydrogen system, considering subsystem constraints and coupling, benefits in spill water reduction and DO mitigation, as well as diverse hydrogen utilization, including re-electrification, blending with natural gas, and direct sales. Comprehensive case studies were conducted to assess the techno-economic performance of the integrated system in different deployment scenarios.

Energy storage, Hydrogen, Hydropower, Optimization↗

Cost Reduction of School Bus Fleet Electrification With Optimized Charging and Distributed Energy Resources: Preprint

Considerations for electrifying school buses are presented with an analysis of battery sizing to match bus driving requirements. The charging and vehicle-to-building dispatch of the electric school buses were optimized to evaluate the potential to reduce the impact of the bus charging on the school's electric utility bill. Distributed energy resources (DER) and flexible building loads were also considered with the school bus electrification to evaluate the further reduction in energy costs with enhanced system integration and optimized dispatch. The effect of degradation on the school bus batteries was analyzed to determine if the smart charging and vehicle-to-building battery operation decreases the life of the battery. The results show that there is an opportunity to mitigate the increase of electric utility bills with improved charging controls and bi-directionally operating the school bus batteries to reduce building demand charges. The battery degradation analysis using dispatch with optimized charging and discharging shows acceptable battery life.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Wave Energy Converter Control Competition: Overview

Over the past two years, a wave energy converter control systems competition (WECCCOMP) has been in progress, with the objective of comparing different wave energy converter (WEC) control paradigms on a standard benchmark problem. The target system is a point absorber, corresponding to a single float with an absolute reference, of the WaveStar WEC prototype. The system was modelled in WEC-Sim, with the hydrodynamic parameters validated against tank test data. Competitors were asked to design and implement a WEC control system for this model, with performance evaluated across six sea states. The evaluation criteria included a weighted combination of average converted power, peak/average power, and the degree to which the system physical constraints were exploited or temporarily exceeded.

16 TIDAL AND WAVE POWER↗