Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical circuits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Cu-Local Structures and Their Relation with Nanoscale Electrical Performance in CdTe

For decades, copper has been introduced in CdTe devices to improve overall performance (open circuit voltage, fill factor, and series resistance). While multiple articles have reported on Cu-based defects, very little is known about how the local structure around the copper atom affects electrical performance. Using X-ray Absorption Near Edge Structure (XANES) coupled with X-ray microscopy we investigate good and poor performing region in Cu-doped CdTe devices. Our XANES coupled with theoretical standards by FEFF9 suggest that CU 2 Te phase and Cu Cd may be responsible for the high electrical performance of the regions under study. This correlation of structure-performance at the nanoscale offers a unique framework to understand and tune processes with deep implications to the overall electrical performance of the solar cell.

CdTe↗

Light‐Driven BiVO 4 –C Fuel Cell with Simultaneous Production of H 2 O 2

Abstract Photoelectrochemical (PEC) systems have been researched for decades due to their great promise to convert sunlight to fuels. The majority of the research on PEC has been using light to split water to hydrogen and oxygen, and its performance is limited by the need of additional bias. Another research direction on PEC using light, is to decompose organic materials while producing electricity. In this work, the authors report a new type of unassisted PEC system that uses light, water and oxygen to simultaneously produce electricity and hydrogen peroxide (H 2 O 2 ) on both the photoanode and cathode, which is essentially a light‐driven fuel cell with H 2 O 2 as the main product at the two electrodes, meanwhile achieving a maximum power density of 0.194 mW cm ‐2 , an open circuit voltage of 0.61 V, and a short circuit current density of 1.09 mA cm ‐2 . The electricity output can be further used as a sign for cell function when accompanied by a detector such as a light‐emitting diode (LED) light or a multimeter. This is the first work that shows H 2 O 2 two‐side generation with a strict key factors study of the system, with a clear demonstration of electricity output ability using low‐cost earth abundant materials on both sides, which represents an exciting new direction for PEC systems.

Shi, Xinjian↗

Design and Verification of An Open-Circuit Electro-Hydraulic Actuator System with An Integrated Electro-Hydraulic Unit

This paper proposes an electro-hydraulic actuator (EHA) system, and two novel-designed electro-hydraulic units (EHU) consisting of a fixed-displacement hydraulic pump and a variable-speed electric motor. Both the novel EHU designs integrate an electric machine and a hydraulic machine in a single unit, featuring compactness and power density. However, they differ for salient aspects such as power and electric machine cooling system. The EHA system features an open circuit design, where hydraulic hoses connect the EHU with a tank, a valve manifold, and the hydraulic cylinder. In this way, the proposed EHA technology can be used to implement distributed hydraulic actuation in a vehicle without requiring changes to the hydraulic actuators or at the overall layout of the hydraulic components with respect to the original vehicle design. A dedicated test rig is developed to verify the performance of the proposed EHA system. The efficiency of the EHA is measured in a steady state and under a realistic duty cycle of a commercial compact loader. The measured efficiency of the system can reach 54% with up to 20kN load and 6kW power level.

42 ENGINEERING↗

Internal configuration of prismatic lithium-ion cells at the onset of mechanically induced short circuit

The response of Li-ion cells to mechanically induced internal electrical shorts is an important safety performance metric design. We assume that the battery internal configuration at the onset of electrical short influences the subsequent response and can be used to gauge the safety risk. We subjected a series of prismatic Li-ion cells to lateral pinching using 0.25", 0.5", 1", 2" and 3" diameter steel balls until the onset of internal short. The external aluminum enclosure froze the internal cell configuration at the onset of short and enabled us to cross-section the cells, and take the cross-section images. The images indicate that an internal electric short is preceded by extensive strain partitioning in the cells, fracturing and tearing of the current collectors, and cracking and slipping of the electrode layers with multiple fault lines across multiple layers. These observations are at odds with a common notion of homogeneous deformation across the layers and strain hardening of electrodes that eventually punch through the separator and short the cell. The faults are akin to tectonic movements of multiple layers that are characteristic of granular materials and bonded aggregates. As a result, the short circuits occur after extensive internal faulting, which implies significant stretching and tearing of separators.

25 ENERGY STORAGE↗

Magnetic Random Access Memory based non-volatile asynchronous Muller cell for ultra-low power autonomous applications

Micro and nano electronic integrated circuit domain is today mainly driven by the advent of the Internet of Things for which the constraints are strong, especially in terms of power consumption and autonomy, not only during the computing phases but also during the standby or idle phases. In such ultra-low power applications, the circuit has to meet new constraints mainly linked to its changing energetic environment: long idle phases, automatic wake up, data back-up when the circuit is sporadically turned off, and ultra-low voltage power supply operation. Such circuits have to be completely autonomous regarding their unstable environment, while remaining in an optimum energetic configuration. Therefore, we propose in this paper the first MRAM-based non-volatile asynchronous Muller cell. This cell has been simulated and characterized in a very advanced 28 nm CMOS fully depleted silicon-on-insulator technology, presenting good power performance results due to an extremely efficient body biasing control together with ultra-wide supply voltage range from 160 mV up to 920 mV. The leakage current can be reduced to 154 pA thanks to reverse body biasing. We also propose an efficient standard CMOS bulk version of this cell in order to be compatible with different fabrication processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lightning-activated electrical ground for cable shields

Device protects cables used to connect circuits that are physically separated from lightning-induced high-voltage. Circuit returns to normal high impedance open configuration after lightning-induced shield voltage is dissipated.

Castle, K. D.↗

Comparison of entropy production rates in two different types of self-organized flows: Benard convection and zonal flow

Two different types of self-organizing and sustaining ordered motion in fluids or plasmas--one is a Benard convection (or streamer) and the other is a zonal flow--have been compared by introducing a thermodynamic phenomenological model and evaluating the corresponding entropy production rates (EP). These two systems have different topologies in their equivalent circuits: the Benard convection is modeled by parallel connection of linear and nonlinear conductances, while the zonal flow is modeled by series connection. The ''power supply'' that drives the systems is also a determinant of operating modes. When the energy flux is a control parameter (as in usual plasma experiments), the driver is modeled by a constant-current power supply, and when the temperature difference between two separate boundaries is controlled (as in usual computational studies), the driver is modeled by a constant-voltage power supply. The parallel (series)-connection system tends to minimize (maximize) the total EP when a constant-current power supply drives the system. This minimum/maximum relation flips when a constant-voltage power supply is connected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impedance Characteristics and Polarization Behavior of a Microbial Fuel Cell in Response to Short-Term Changes in Medium pH

pH oppositely influences anode and cathode performance in microbial fuel cells. The differential electrochemical effects at each electrode and the resultant full-cell performance were analyzed in medium pH from 6.0 to 8.0. Potentials changed -60 mV/pH for the anode and -68 mV/pH for the cathode, coincident with thermodynamic estimations. Open circuit voltage reached a maximum (741 mV) at pH 7, and maximum power density was highest (712 mW/m{sup 2}) at pH 6.5 as the cathode performance improved at lower pH. Maximum current density increased and apparent half-saturation potential (E{sub KA}) decreased with increasing medium pH due to improved anode performance. An equivalent circuit model composed of two time constant processes accurately fit bioanode impedance data. One of these processes was consistently the rate-limiting step for acetate-oxidizing exoelectrogenesis, with its pH-varying charge transfer resistance R{sub 2} ranging from 2- to 321-fold higher than the pH-independent charge transfer resistance R{sub 1}. The associated capacitance C{sub 2} was 2-3 orders of magnitude larger than C{sub 1}. R{sub 2} was lowest near E{sub KA} and increased by several orders of magnitude at anode potentials above E{sub KA}, while R{sub 1} was nearly stable. However, fits deviated slightly at potentials above E{sub KA} due to emerging impedance possibly associated with diffusion and excessive potential.

30 DIRECT ENERGY CONVERSION↗

Residential Advanced Photovoltaic Inverter Pilot Study Results for Select Distribution Secondaries in Hawai'i

Penetration levels of residential rooftop solar photovoltaic (PV) generation on the Hawaiian island of O'ahu have increased significantly in recent years, with many circuits now at the limits of their PV hosting capacity. NREL and Hawaiian Electric have used this opportunity to deploy advanced inverters at new customer installations that would not otherwise have been approved, as a pilot study to gain first-hand operational field data and experience on the impact of inverter-based grid support functions. At each customer location, the deployed advanced inverters were remotely controlled and monitored. Additionally, customer AMI (smart meter) and secondary distribution transformer data was also available for the analysis. The analysis focused on quantifying the customer behind-the-meter voltage rise due to PV production, determining the customer voltage rise with advanced inverters in unity power factor as well as advanced grid support function modes, and estimating the curtailment when inverters have Volt-VAR and Volt-Watt enabled. The results show that: 1) Behind-the-meter voltage rise is often not negligible. 2) An inverter's operating point on a Volt-VAR/Volt-Watt curve depends strongly on the design of the secondary system on which it is installed. 3) The mitigation of voltage rise on the secondary system using Volt-VAR may not be effective if only a small proportion of inverters have grid support enabled, or if the reactance/resistance (X/R) ratio of the grid is low. 4) Volt-Watt curtailment can be estimated using co-located irradiance sensors but there may be opportunities to estimate it using inverter internal electrical measurements. 5) Estimated curtailment is very low for the locations analyzed to date.

14 SOLAR ENERGY↗

Slow light, open-cavity formation, and large longitudinal electric field on a slab waveguide made of indefinite permittivity metamaterials

The optical properties of slab waveguides made of indefinite permittivity ({epsilon}) materials (IEMs) are considered. In this medium, the real part of the transverse permittivity is negative while that of the longitudinal permittivity is positive. At any given frequency, the IEM waveguide supports an infinite number of transverse magnetic (TM) eigenmodes. For a slab waveguide with a fixed thickness, at most only one TM mode is forward wave. The remainder are backward waves which can have a very large phase index. At a critical thickness, the waveguide supports degenerate forward- and backward-wave modes with zero group velocity if loss is absent. Above the critical thickness, the waveguide supports complex-conjugate decay modes instead of propagating modes. The presence of loss in IEMs will lift the TM mode degeneracy, resulting in modes with finite group velocity. A feasible realization is proposed. The performance of the IEM waveguide is analyzed and possible applications are discussed, which are supported by numerical calculations. These slab waveguides can be used to make optical delay lines in optical buffers to slow down and trap light, to form open cavities, to generate strong longitudinal electric fields, and as phase shifters in optical integrated circuits. Although the presence of loss will hinder these applications, gain can be introduced to compensate the loss and enhance the performance.

36 MATERIALS SCIENCE↗

Simultaneous determination of electrical conductivity and thickness of nonmagnetic metallic foils using two-sided multifrequency eddy current techniques

Here, in this paper, we describe a simple method for performing multifrequency eddy current characterization of free-standing uniform-thickness metallic foils using a forked inductive coil arrangement. The method involves measuring the mutual inductance between two coils when a foil is present between the coils, and when it is not present; the ratio of these mutual inductances is compared with an analytical solution, and foil conductivity, thickness, and sheet resistance are simultaneously estimated using numerical inversion and least-squares fitting. This method was used to characterize 34 non-ferrous metallic samples with thicknesses between 50 and 640 μm and with conductivities between 0.8 × 10 7 and 5.8 × 10 7 S/m. The estimated thicknesses from eddy current characterization agreed well with those measured using confocal optical techniques; the two approaches agreed to within 1 μm for samples that were thinner than 200 μm, and to within 0.5% for samples that had a thickness of 200 μm or greater. The estimated conductivities from eddy current characterization were in close agreement with expected values, given knowledge of the materials used. A particular strength of this approach is that the instrumentation needed is broadly available in research and development laboratories and the associated fixturing is easy to manufacture and assemble. A calibration procedure is described that can be used to reduce errors from geometric uncertainties. This calibration requires a sample that has only a known conductivity or thickness; both do not need to be known. The method described herein is likely extensible to conductivities and thickness well outside the ranges measured as part of this work.

47 OTHER INSTRUMENTATION↗

Recycling of WEEE: Characterization of spent printed circuit boards from mobile phones and computers

Highlights: > This paper presents new and important data on characterization of wastes of electric and electronic equipments. > Copper concentration is increasing in mobile phones and remaining constant in personal computers. > Printed circuit boards from mobile phones and computers would not be mixed prior treatment. - Abstract: This paper presents a comparison between printed circuit boards from computers and mobile phones. Since printed circuits boards are becoming more complex and smaller, the amount of materials is constantly changing. The main objective of this work was to characterize spent printed circuit boards from computers and mobile phones applying mineral processing technique to separate the metal, ceramic, and polymer fractions. The processing was performed by comminution in a hammer mill, followed by particle size analysis, and by magnetic and electrostatic separation. Aqua regia leaching, loss-on-ignition and chemical analysis (inductively coupled plasma atomic emission spectroscopy - ICP-OES) were carried out to determine the composition of printed circuit boards and the metal rich fraction. The composition of the studied mobile phones printed circuit boards (PCB-MP) was 63 wt.% metals; 24 wt.% ceramics and 13 wt.% polymers; and of the printed circuit boards from studied personal computers (PCB-PC) was 45 wt.% metals; 27 wt.% polymers and ceramics 28 wt.% ceramics. The chemical analysis showed that copper concentration in printed circuit boards from personal computers was 20 wt.% and in printed circuit boards from mobile phones was 34.5 wt.%. According to the characteristics of each type of printed circuit board, the recovery of precious metals may be the main goal of the recycling process of printed circuit boards from personal computers and the recovery of copper should be the main goal of the recycling process of printed circuit boards from mobile phones. Hence, these printed circuit boards would not be mixed prior treatment. The results of this paper show that copper concentration is increasing in mobile phones and remaining constant in personal computers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical and experimental analysis of mechanically induced failure in electric vehicle battery modules

Mitigating thermal runaway and cell-to-cell propagation is essential for improving the safety of electric and hybrid vehicles. Enhancing digital twin capabilities to predict battery mechanical abuse is particularly critical for automotive and aerospace applications, where crashworthiness is a key concern. Understanding failure conditions and propagation in battery modules during mechanical abuse is complex due to interactions between structural deformation, heat transfer, electrochemical processes, exothermic reactions and mechanical fracture. While prior studies have focused on modeling cell-level behavior, extending these models to module or pack level is necessary for a system level understating of electric vehicle safety. This study develops coupled large deformation finite element models that simultaneously solve for electrochemistry, material failure, internal short circuit and thermal runaway propagation. The models account for mechanical and thermal interactions between lithium-ion cells and other battery components while the contact interfaces are evolving with time. Model-predicted voltage, temperature and force responses are compared with experimental data for validation. The results demonstrate that the approach captures key failure mechanisms, including thermal propagation through heat transfer, electrical propagation from short circuits in parallel-connected cells, and mechanical propagation via penetration and crack formation. These findings show that computational models are valuable tools for understanding battery module failure and providing insight that can reduce the need for extensive experimental testing.

25 ENERGY STORAGE↗

Grid FriendlyTM Device Model Development and Simulation

In late 2007, the Bonneville Power Administration (BPA) contracted Pacific Northwest National Laboratory (PNNL) to complete a research project titled Grid-Responsive Demand-Side Control Using Grid Friendly Appliance Technologies [Hammerstrom 2009, DeSteese and Hammerstrom 2009]. Cosponsors included Portland General Electric (PGE) and Puget Sound Energy (PSE). The project focused on applications of the Grid Friendly Appliance (GFA) controller, which is an autonomous controller that was designed to advise devices like appliances concerning valuable demand-side grid services that should be conducted. The controller bases its advice on observations it makes from the ac voltage signal. Electric tank water heaters were selected to be controlled by the GFA controller in this project. Two autonomous responses are addressed herein. First, an under-voltage-responsive water heater is able to recognize sudden reductions in feeder circuit voltage at each water heater and may curtail any electric load that is being consumed by the water heater. These under-voltage events are usually induced by nearby electrical faults. An under-voltage response is necessarily specified by the set of voltage thresholds at which the responsive water heaters would respond. The set of voltages at which the curtailment would be released must also be specified. Additionally, any delays prior to the water heater load becoming curtailed or again released must be specified. For example, a delay may be intentionally imposed prior to curtailing water heater loads to avoid responses during the fault itself. Much longer and randomized delays should be imposed prior to the release of curtailments in order to re-establish diversity of the water heater loads and soften what could otherwise be an abrupt reintroduction of a large aggregated electrical load into the already stressed grid region.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Domain Reflectometry NDE for Aging Cables in Nuclear Power Plants

Cable insulation polymers are among the more susceptible materials to age-related degradation within a nuclear power plant. This is recognized by both regulators and utilities, so all plants have developed cable aging management programs to detect damage before critical component failure in compliance with regulatory guidelines. Although a wide range of tools are available to evaluate cables and cable systems, cable aging management programs vary in how condition monitoring and nondestructive examinations are conducted as utilities search for the most reliable and cost-effective ways to assess cable system condition. Frequency domain reflectometry (FDR) is emerging as one valuable tool to locate and assess damaged portions of a cable system with minimal cost and only requires access in most cases to one of the cable terminal ends. Since laboratory studies to evaluate the use of FDR for inspection of aged cables can be expensive and data interpretation may be confounded by multiple factors which influence results, a model-based approach is desired to parametrically investigate the effect of insulation material damage in a controlled manner. This work describes development of a physics-based FDR model which uses finite element simulations of cable segments in conjunction with cascaded circuit element simulations to efficiently study a cable system. One or more segments of the cable system model have altered physical or electrical properties which represent the degree of damage and the location of the damage in the system. This circuit model is then subjected to a simulated FDR examination. The modeling approach is verified using several experimental cases and by comparing it to a commercial simulator suitable for simulation of some cable configurations. The model is used to examine a broad range of parameters including defect length, defect profile, degree of degradation, number and location of defects, FDR bandwidth, and addition of impedance-matched extensions to minimize the end-shadow effect.

Cable Inspection, Frequency Domain Reflectometry↗

On the Impact of High-Order Harmonic Generation in Electrical Distribution Systems

The modern power grid has seen a rise in the integration of non-linear loads, presenting a significant concern for operators. These loads introduce unwanted harmonics, leading to potential issues such as overheating and improper functioning of circuit breakers. In pursuing a more sustainable grid, the adoption of electric vehicles (EVs) and photovoltaic (PV) systems in residential networks has increased. Understanding and examining the effects of high-order harmonic frequencies beyond $1.5$ kHz is crucial to understanding their impact on the operation and planning of electrical distribution systems under varying nonlinear loading conditions. This study investigates a diverse set of critical power electronic loads within a household modeled using PSCAD/EMTdc, analyzing their unique harmonic spectra. This information is utilized to run the time-series harmonic analysis program in OpenDSS on a modified IEEE 34 bus test system model. The impact of high-order harmonics is quantified using metrics that evaluate total harmonic distortion (THD), transformer harmonic-driven eddy current loss component, and propagation of harmonics from the source to the substation transformer.

Peerzada, Aaqib A. [BATTELLE (PACIFIC NW LAB)]↗

A complementary MOS process

The complete sequence used to manufacture complementary metal oxide semiconductor (CMOS) integrated circuits is described. The fixed-gate array concept is presented as a means of obtaining CMOS integrated circuits in a fast and reliable fashion. Examples of CMOS circuits fabricated by both the conventional method and the fixed-gate array method are included. The electrical parameter specifications and characteristics are given along with typical values used to produce CMOS circuits. Temperature-bias stressing data illustrating the thermal stability of devices manufactured by this process are presented. Results of a preliminary study on the radiation sensitivity of circuits manufactured by this process are discussed. Some process modifications are given which have improved the radiation hardness of our CMOS devices. A formula description of the chemicals and gases along with the gas flow rates is also included.

Jhabvala, M. D.↗