Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Power quality disturbances diagnosis: A 2D densely connected convolutional network framework

The fast and accurate diagnosis of power quality disturbances (PQD) aids in avoiding shutdowns and unnecessary procedures, concerning electric energy distribution systems. As such, a number of techniques have been tested and applied in order to reach this objective. Majority of the techniques applied are two-step based. On the first step, power quality disturbances features are extracted. Second step, considering features extracted, disturbance classification is implemented. Recently, relevant literature has presented data-driven signal processing-based approaches, as deep convolutional neural networks (DCNN), which can implement both processing steps while providing automated recognition of patterns and outliers in data. However, not considered by state-of-art, power quality disturbances are evolving in nature, while all possible regularities might not be represented in the dataset. In this work a 2 Dimension Densely Connected Convolutional Network (2D-DenseNet) framework is presented. Further, a case study with synthetic disturbance events are analyzed. Easy-to-implement formulation, built on the 2D-DenseNet, without hard-to-design parameters, highlight potential aspects for real-life implementation.

42 ENGINEERING↗

A Machine Learning Framework to Deconstruct the Primary Drivers for Electricity Market Price Events

As the electricity grid is moving towards a 100% Renewable Energy Source Bulk Power Grid, the overall operations of the power system operations and electricity markets are changing. The electricity markets are not only dispatching resources economically but also taking into account various controllable actions like renewable curtailment, transmission congestion mitigation, and energy storage optimization to make sure the grid is operating reliably. As a result, price formations in electricity markets have become quite complex. Traditional root cause analysis and statistical approaches are rendered inapplicable to analyze and infer the main drivers behind price formation in the modern grid and markets with variable renewable energy (VRE). In this paper, we propose a machine learning analysis framework to deconstruct some primary drivers for price formation in modern electricity markets with high renewable energy and the outcomes can be utilized for various critical aspects of market design, renewable dispatch and curtailment, operations, and cyber-security applications. The framework can be applied to any ISO or market data and in this paper it is applied to open-source publicly available datasets from California Independent System Operator (CAISO) and ISO New England.

machine learning (ML), electricity markets, Renewa↗

Hybrid Electric Drivetrain Testing and Design (CRADA CRD-17-00699 Final Report)

Hybrid electric drivetrains have recently become of a great interest in the medium and heavy-duty vehicle market as it enables substantial reduction of petroleum use, vehicle level fuel use and criteria pollutant emissions. These vehicle performance improvements are not only economically beneficial for business operations relying on large fleets of vehicles, they are also paramount for curbing energy use and the negative effects of vehicle operations on the environment. Efficient Drivetrains, Inc. (EDI), acquired in July 2018 by Cummins, Inc., is a small company focused on development of medium and heavy-duty hybrid electric drivetrains. EDI has already developed the general hardware architecture of their drivetrain system, but there is still a significant effort to be done on optimizing the system in terms of control strategies and component sizing in order to maximize the benefits of the hybrid drivetrain. Historically, hybrid electric systems have proven to deliver better fuel economy in certain applications than their conventional counterparts. Particular areas of advantageous applications are vocations with kinetically intensive transient duty cycles and operations requiring some sort of power take off whose power demand is not well matched to the size of the vehicle’s main engine, thus forcing it to operate in extremely inefficient operating modes. Hybrid drivetrains can be at a disadvantage when pressed into duty cycle operation consisting of extensive steady state highway cruise due to various design compromises optimized for more transient operation. This can also lead to increase in vehicle emissions if the system is not optimized properly. Ample opportunity for extensive optimization is needed to overcome these obstacles.

33 ADVANCED PROPULSION SYSTEMS↗

Peak load reduction and load shaping in HVAC and refrigeration systems in commercial buildings by using a novel lightweight dynamic priority-based control strategy

Reducing peak power demand in a building can reduce electricity expenses for the building owner and contribute to the efficiency and reliability of the electrical power grid. For the building owner, reduced expenses come from the reduction or elimination of peak power charges on electricity bills. For the power system operator, reducing peak power demand leads to a more predictable load profile and reduces stress on the electric grid system. Herein we present a computationally inexpensive, dynamic, and retrofit-deployable control strategy to effect peak load reduction and load shaping. The effectiveness of the control strategy is examined in a simulation with 80 air-conditioning units and 40 refrigeration units. The results show that a peak demand reduction of 60 kW can be achieved relative to peak demand in a typical set point–based approach. The proposed strategy was deployed in a gymnasium building with four rooftop HVAC units, where it showed over 15% peak demand (kW) reduction savings while maintaining or lowering energy consumption (in kilowatt-hours) relative to the set point–based thermostat controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Designing Dynamic Wireless Power Transfer Corridors for Heavy Duty Battery Electric Commercial Freight Vehicles

The use of wireless power transfer systems, consisting of inductive electrical coils on the vehicle and the power source may be designed for dynamic operations where the vehicle will absorb energy at highway speeds from transmitting coils in the road. This has the potential to reduce the onboard energy storage requirements for vehicles while enabling significantly longer missions. This paper presents an approach to architecting a dynamic wireless power transfer corridor for heavy duty battery electric commercial freight vehicles. By considering the interplay of roadway power capacity, roadway and vehicle coil coverage, seasonal road traffic loading, freight vehicle class and weight, vehicle mobility energy requirements, on-board battery chemistry, non-electrified roadway vehicle range requirements, grid capacity, substation locations, and variations in electricity costs, we minimize the vehicle TCO by architecting the electrified roadway and the vehicle battery simultaneously. The idea optimizes battery size and chemistry so that the depth of discharge between recharge events and expected life are balanced, thus fully utilizing the energy available throughout the course of the battery system's life. The approach is illustrated by applying it to the I-75 freight corridor, where the framework developed may be expanded and applied to a larger interstate system, expanded regional corridor, or other transportation network.

Sujan, Vivek↗

20% of US electricity from wind will have limited impacts on system efficiency and regional climate

Abstract Impacts from current and future wind turbine (WT) deployments necessary to achieve 20% electricity from wind are analyzed using high resolution numerical simulations over the eastern USA. Theoretical scenarios for future deployments are based on repowering (i.e. replacing with higher capacity WTs) thus avoiding competition for land. Simulations for the contemporary climate and current WT deployments exhibit good agreement with observed electricity generation efficiency (gross capacity factors (CF) from simulations = 45–48%, while net CF for WT installed in 2016 = 42.5%). Under the scenario of quadrupled installed capacity there is a small decrease in system-wide efficiency as indicated by annual mean CF. This difference is approximately equal to that from the two simulation years and may reflect saturation of the wind resource in some areas. WT modify the local near-surface climate in the grid cells where they are deployed. The simulated impact on near-surface climate properties at both the regional and local scales does not increase with increasing WT installed capacity. Climate impacts from WT are modest compared to regional changes induced by historical changes in land cover and to the global temperature perturbation induced by use of coal to generate an equivalent amount of electricity.

17 WIND ENERGY↗

A Systematic Study to Determine 5G Baseline Performance for Scientific Computing

The fifth-generation (5G) cellular networks envisions achieving higher data rates, improved connectivity, reduced latency, and better quality of service (QoS) than the fourthgeneration (4G) cellular networks. Such improved performance can be utilized to address the challenges in applications such as electricity generation in power systems. The traditional power grids responsible for electricity generation suffer from drawbacks such as life-threatening blackout crises, and energy storage proliferation as they are not robust to extreme climatic conditions. A recent study proposed the idea of extending the capabilities of advanced wireless technologies such as the current 5G to develop a robust, energy-efficient, and secure smart grids. However there are two main challenges associated with the integration of power systems and wireless technologies. First, it is imperative to understand the architecture and the enabling technologies of 5G to ensure that the performance requirements of the smart grids are met. Second, an end-to-end testbed is required to determine if the performance requirements are met by estimating the 5G characteristics such as latency, and throughput. Our proposed alleviates the aforementioned concerns in the following manner. To begin with, a systematic study of the 5G architecture including both the StandAlone (SA) and Non-Standalone (NSA) operations is presented. Furthermore, a detailed survey of the possible 5G enabling technologies is elicited. In addition to these, an end-toend testbed that can estimate the 5G characteristics is explained in detail with appropriate preliminary results.

5G, 5G Communication↗

A taxonomy of systems that combine utility-scale renewable energy and energy storage technologies

Interest in renewable energy-based hybrid systems—which combine multiple renewable energy and/or energy storage technologies—is apparent and growing. Such systems could play an important role in the grid of the future, but our ability to quantify their potential impacts is hindered by (a) the inconsistent treatment of hybrid systems and (b) an incomplete understanding of which aspects of hybridization will have the greatest influence. In this article, we review the literature and propose an organization scheme for utility-scale hybrid systems in which electricity is generated from commercially available, renewable energy technologies, and electricity is the only output. Based on this literature review, we propose three categories for delineating systems that link multiple renewable energy and/or energy storage technologies: co-located resources (locational linkage only), virtual power plants (operational linkage only), and full hybrids (location and operational linkages). Proposing a categorization based on whether the systems involve locational and/or operational linkages reflects the fact that technology combinations do not represent a meaningful delineation. In addition, the categories are ideal for informing model development efforts, by identifying the unique characteristics that must be captured in adequate representations of systems that fall under each category. Our categories can also help inform policy considerations, as they delineate system characteristics that would introduce distinct permitting, siting, interconnection, and policy challenges. Therefore, we believe that our proposed taxonomy will help organize thinking and research efforts in a way that will enable consistent evaluation of the costs, values, and potential of renewable energy-based hybrids.

25 ENERGY STORAGE↗

Speed to Power: Solutions for Accelerating Large Load Connections

Rapid growth in demand from data centers and other large loads is creating a range of new challenges for electricity planners, investors, system operators, and regulators, leading to bottlenecks that have slowed connection of large loads to the electric grid. In response, innovative solutions for accelerating large load connections are beginning to emerge across the U.S. Drawing on an extensive document and literature review, this report identifies more than 40 potential solutions for accelerating large load connections, organized into five functional areas: load forecasting, interconnection, resource planning and procurement, markets and operations, and cost allocation and ratemaking. The five functional areas provide a framework for organizing challenges and solutions to large load connection bottlenecks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Electric Drivetrain Testing and Design (CRADA CRD-17-00699 Final Report)

Hybrid electric drivetrains have recently become of a great interest in the medium and heavy-duty vehicle market as it enables substantial reduction of petroleum use, vehicle level fuel use and criteria pollutant emissions. These vehicle performance improvements are not only economically beneficial for business operations relying on large fleets of vehicles, they are also paramount for curbing energy use and the negative effects of vehicle operations on the environment. Efficient Drivetrains, Inc. (EDI), acquired in July 2018 by Cummins, Inc., is a small company focused on development of medium and heavy-duty hybrid electric drivetrains. EDI has already developed the general hardware architecture of their drivetrain system, but there is still a significant effort to be done on optimizing the system in terms of control strategies and component sizing in order to maximize the benefits of the hybrid drivetrain. Historically, hybrid electric systems have proven to deliver better fuel economy in certain applications than their conventional counterparts. Particular areas of advantageous applications are vocations with kinetically intensive transient duty cycles and operations requiring some sort of power take off whose power demand is not well matched to the size of the vehicle’s main engine, thus forcing it to operate in extremely inefficient operating modes. Hybrid drivetrains can be at a disadvantage when pressed into duty cycle operation consisting of extensive steady state highway cruise due to various design compromises optimized for more transient operation. This can also lead to increase in vehicle emissions if the system is not optimized properly. Ample opportunity for extensive optimization is needed to overcome these obstacles.

33 ADVANCED PROPULSION SYSTEMS↗

Probabilistic Risk Assessment of a Light Water Reactor Coupled with a High-Temperature Electrolysis Hydrogen Production Plant

This paper presents recent updates on the Level 1 Probabilistic Risk Assessment (PRA) of Light Water Reactors (LWRs) coupled with a hydrogen production plant. It provides the overview of past results on the PRA for Pressurized Water Reactors (PWRs) and Boiling Water Reactors (BWRs) coupled to a 1150 MW High Temperature Electrolysis Facility (HTEF), as well as the latest research results for a smaller 100 MW HTEF facility. Differences between the two HTEF designs are listed. Key differences include the amount and quality of diverted LWR steam, complexity of the Heat Extraction System (HES), and the electrical power source for the HTEF plant. A Failure Mode and Effect Analysis (FMEA) was conducted for the new HTEF design, and the LWR PRA models were modified in the SAPHIRE risk assessment tool to account for the newly identified risk contributors. These include the steam loss event at the HES system, the electrical overcurrent event at the HTEF facility and at the transmission line from the LWR plant, and the hydrogen detonation event at the HTEF facility. The coupling of LWRs with a 100 MW HTEF increases the frequency of several initiating events. For the reference PWR, the largest frequency increase is for the steam line break event at 5.5%. While for the reference BWR, the largest frequency increase is for the switchyard-related Loss of Offsite Power (LOOP) event at 0.11%. The overall plant risk increases by 6.56% and 0.03% for PWR and BWR reference plants respectively. It is found that these risk metrics satisfy the safety criteria of both 10 CFR 50.59 and Regulatory Guide 1.174 licensing pathways.

08 HYDROGEN↗

Electrical control of coherent spin rotation of a single-spin qubit

Nitrogen vacancy (NV) centers, optically active atomic defects in diamond, have attracted tremendous interest for quantum sensing, network, and computing applications due to their excellent quantum coherence and remarkable versatility in a real, ambient environment. One of the critical challenges to develop NV-based quantum operation platforms results from the difficulty in locally addressing the quantum spin states of individual NV spins in a scalable, energy-efficient manner. Here, we report electrical control of the coherent spin rotation rate of a single-spin qubit in NV-magnet based hybrid quantum systems. By utilizing electrically generated spin currents, we are able to achieve efficient tuning of magnetic damping and the amplitude of the dipole fields generated by a micrometer-sized resonant magnet, enabling electrical control of the Rabi oscillation frequency of NV spins. Our results highlight the potential of NV centers in designing functional hybrid solid-state systems for next-generation quantum-information technologies. The demonstrated coupling between the NV centers and the propagating spin waves harbored by a magnetic insulator further points to the possibility to establish macroscale entanglement between distant spin qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mauka Energy FEVER Tool DOE SBIR Phase 1 Final Scientific/Technical Report

This report is on the Forestry Electric Vehicle Energy Routing (FEVER) Tool, a novel software system developed to support heavy-duty electric vehicle (EV) operations in remote, forested, and mountainous regions. The Phase I project aimed to demonstrate the feasibility of modeling EV energy consumption using terrain elevation, road conditions, and route features specific to forestry logistics. The tool combines geographic information systems (GIS), electric motor physics, and vehicle-specific data to calculate feasible, energy-efficient routes. Collaborations with Oregon State University’s Research Forests and Titan Freight Systems enabled collection and validation of GPS and elevation-based trip data. The FEVER Tool offers substantial opportunities for the efficient management of medium- and heavy-duty electric vehicles in sectors like forestry, agriculture, mining, defense and waste management—areas which are beginning to adopt HDEVs. The project demonstrated technical feasibility and lays the groundwork for commercial development and deployment in other industries and environmental conditions in Phase II.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Transactive Approach for Service Restoration Utilizing Customer Load Flexibility and Grid-Edge Resources

This paper develops a transactive energy system model to restore electricity to customers in an isolated distribution system after an outage. The model is developed to engage a variety of customer types - prosumers, flexible loads, critical/noncritical customers, and distributed generators - as active participants in the restoration process. Unlike many existing transactive approaches, the proposed model is developed for service restoration and accounts for various customer types and their autonomy and privacy through an iterative approach to determine the optimal market price, while maintaining systemlevel power flow and voltage constraints. The advantages of the proposed approach are numerically validated on a modified IEEE 123-bus test system.

distributed energy resources↗

System Health and Status Reporting is Used to Improve Infrastructure Systems at the Hanford Site - 20449

Reliable physical infrastructure systems are vital to completing the clean-up mission and the start-up and commissioning of new nuclear waste processing facilities at the Hanford Site. Key infrastructure systems at Hanford include water, sewer, and electrical utilities, roads, telecommunications/network systems, and fire systems. All of the infrastructure systems are non-nuclear, General Service systems that are being maintained under formal engineering configuration control and none are specifically credited in any documented safety analysis (DSA). Starting in calendar year 2017, the Hanford Site's infrastructure and services contractor started producing system health and status reports for a total of 15 critical infrastructure systems as means to get a better understanding of each system's health and how it could be improved to ensure better and more reliable service delivery. As the reporting, tracking, and use of the metrics has matured, the number of systems for which reports are being developed has been expanded to a total of 23. Each of the critical infrastructure systems are assigned primary and alternate design authorities that complete qualifications on each assigned system. The design authorities actively manage and maintain configuration control on each of their systems and track metrics associated with availability, maintenance (corrective and preventive), and configuration of the technical baseline. The metrics are based on the principles established in Chapter V of DOE O 420.1C, Facility Safety, [1] and have been tailored as appropriate to each of the key infrastructure systems. An overall assessment of system health is performed and documented on a routine basis (e.g., quarterly). Included in this documentation is a quantitative score for each of the metrics (i.e., availability, maintenance, configuration management) along with results of system walk-downs, description of any permanent design modifications, identification of new or emerging issues and vulnerabilities affecting the system, and an assessment by the design authority of actions necessary to improve the system health score. The overall status scores are calculated using a formula and based on a pre-determined grading scale, a color is assigned for simple presentation. The information gained from developing the reports is being used to (1) assist with making timely and better informed decisions through the use of solid technical bases that are increasing the overall reliability and capabilities of the Site's infrastructure systems as new expense and capital projects in the Reliability Projects Investment Portfolio (RPIP) are prioritized and executed; (2) feed the risk management program, and (3) integrate the technical content of Master Plans that describe the Site's needs for the system and the system's capabilities to meet those future needs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Transactive Approach for Service Restoration Utilizing Customer Load Flexibility and Grid-Edge Resources: Preprint

This paper develops a transactive energy system model to restore electricity to customers in an isolated distribution system after an outage. The model engages a variety of customer types -- prosumers, flexible loads, critical/noncritical customers, and distributed generators -- as active participants in the restoration process. Unlike many existing transactive approaches, the proposed model is developed for service restoration and accounts for various customer types and their \textit{autonomy} and \textit{privacy} through an iterative approach to determine the optimal market price, while maintaining system-level power flow and voltage constraints. The advantages of the proposed approach are numerically validated on a modified IEEE 123-bus test system.

distributed energy resources↗

A Transactive Approach for Service Restoration Utilizing Customer Load Flexibility and Grid-Edge Resources

This paper develops a transactive energy system model to restore electricity to customers in an isolated distribution system after an outage. The model engages a variety of customer types -- prosumers, flexible loads, critical/noncritical customers, and distributed generators -- as active participants in the restoration process. Unlike many existing transactive approaches, the proposed model is developed for service restoration and accounts for various customer types and their autonomy and privacy through an iterative approach to determine the optimal market price, while maintaining system-level power flow and voltage constraints. The advantages of the proposed approach are numerically validated on a modified IEEE 123-bus test system.