Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

SU-F-BRA-02: Electromagnetic Tracking in Brachytherapy as An Advanced Modality for Treatment Quality Assurance

Purpose: To present the use of Electromagnetic Tracking (EMT) for quality assurance in brachytherapy by means of phantom studies and to assess the clinical applicability of EMT during HDR breast brachytherapy. Methods: An EMT system was investigated to examine its suitability for clinical applications in brachytherapy. A field generator served as electromagnetic field emitter. Sensors (magnetic sensitive only), connected to a control unit, were used and their respective position and orientation inside a pre-defined measurement volume (500 mm cube length) determined. Up to three 6DoF sensors were placed on the phantom’s surface to obtain additional reference coordinates used to derive relative measured positions of a smaller 5DoF sensor inserted in the 6F catheters of the implant. The catheters were successively measured by manual displacement of the sensor at ∼40 mm/s. The measured catheter tracks, acquired multiple times at various locations (CT and treatment room), were smoothed, divided into intervals (2.5 mm dwell step size), registered (rigid Iterative Closest Point transformation) and compared against the known phantom geometry. Results: The reference coordinates were used to exclude the influence of external (e.g., respiratory-induced) motion. Precision tests in a clinical setting showed variances below 1 mm (translational) and 1° (rotational), respectively. Our method for catheter reconstruction preserved the length of the tracked catheter (within 1 mm). The measured tracking accuracy was 1±0.3 mm (maximum: 2 mm). The results are less accurate in environments potentially interfering with the magnetic field, e.g., in the vicinity of ferromagnetic table components. Conclusion: Our EMT system is able to perform reproducible and accurate catheter tracking and reconstruction. Currently, measurements of the implant geometry in HDR breast treatments are initiated. Online implant monitoring by means of EM tracking may be a first step towards advanced brachytherapy treatment QA. The study was financially supported by ELEKTA | Nucletron. There are no further disclosures and conflicts.

60 APPLIED LIFE SCIENCES↗

First Exclusive Measurement of Deeply Virtual Compton Scattering off He 4 : Toward the 3D Tomography of Nuclei

Here, we report on the first measurement of the beam-spin asymmetry in the exclusive process of coherent deeply virtual Compton scattering off a nucleus. The experiment used the 6 GeV electron beam from the CEBAF accelerator at Jefferson Lab incident on a pressurized $^4$He gaseous target placed in front of the CEBAF Large Acceptance Spectrometer (CLAS). The scattered electron was detected by CLAS and the photon by a dedicated electromagnetic calorimeter at forward angles. To ensure the exclusivity of the process, a specially designed radial time projection chamber was used to detect the recoiling $^4$He nuclei. We measured beam-spin asymmetries larger than those observed on the free proton in the same kinematic domain. From these, we were able to extract, in a model-independent way, the real and imaginary parts of the only $^4$He Compton form factor, $\cal H_A$. This first measurement of coherent deeply virtual Compton scattering on the $^4$He nucleus, with a fully exclusive final state via nuclear recoil tagging, leads the way toward 3D imaging of the partonic structure of nuclei.

43 PARTICLE ACCELERATORS↗

Jet fragmentation transverse momentum distributions in pp and p-Pb collisions at $ \sqrt{s}$, $\sqrt{s_{\mathrm{NN}}}$ = 5.02 TeV

Jet fragmentation transverse momentum ( j T ) distributions are measured in proton-proton (pp) and proton-lead (p-Pb) collisions at s NN = 5 . 02 TeV with the ALICE experiment at the LHC. Jets are reconstructed with the ALICE tracking detectors and electromagnetic calorimeter using the anti- k T algorithm with resolution parameter R = 0 . 4 in the pseudorapidity range |η| < 0 . 25. The j T values are calculated for charged particles inside a fixed cone with a radius R = 0 . 4 around the reconstructed jet axis. The measured j T distributions are compared with a variety of parton-shower models. Herwig and P ythia 8 based models describe the data well for the higher j T region, while they underestimate the lower j T region. The j T distributions are further characterised by fitting them with a function composed of an inverse gamma function for higher j T values (called the “wide component”), related to the perturbative component of the fragmentation process, and with a Gaussian for lower j T values (called the “narrow component”), predominantly connected to the hadronisation process. The width of the Gaussian has only a weak dependence on jet transverse momentum, while that of the inverse gamma function increases with increasing jet transverse momentum. For the narrow component, the measured trends are successfully described by all models except for Herwig. For the wide component, Herwig and PYTHIA 8 based models slightly underestimate the data for the higher jet transverse momentum region. These measurements set constraints on models of jet fragmentation and hadronisation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An updated nuclear-physics and multi-messenger astrophysics framework for binary neutron star mergers

The multi-messenger detection of the gravitational-wave signal GW170817, the corresponding kilonova AT2017gfo and the short gamma-ray burst GRB170817A, as well as the observed afterglow has delivered a scientific breakthrough. For an accurate interpretation of all these different messengers, one requires robust theoretical models that describe the emitted gravitational-wave, the electromagnetic emission, and dense matter reliably. In addition, one needs efficient and accurate computational tools to ensure a correct cross-correlation between the models and the observational data. For this purpose, we have developed the Nuclear-physics and Multi-Messenger Astrophysics framework NMMA. The code allows incorporation of nuclear-physics constraints at low densities as well as X-ray and radio observations of isolated neutron stars. In previous works, the NMMA code has allowed us to constrain the equation of state of supranuclear dense matter, to measure the Hubble constant, and to compare dense-matter physics probed in neutron-star mergers and in heavy-ion collisions, and to classify electromagnetic observations and perform model selection. Here, we show an extension of the NMMA code as a first attempt of analyzing the gravitational-wave signal, the kilonova, and the gamma-ray burst afterglow simultaneously. Incorporating all available information, we estimate the radius of a 1.4M ⊙ neutron star to be $R$ $=$ $11.98^{+0.35}_{-0.04}$ km.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-resolved Coulomb-explosion imaging of nuclear wave-packet dynamics induced in diatomic molecules by intense few-cycle laser pulses

We studied the nuclear dynamics in diatomic molecules (N{sub 2}, O{sub 2}, and CO) following their interaction with intense near-IR few-cycle laser pulses. Using Coulomb-explosion imaging in combination with the pump-probe approach, we mapped dissociation pathways of those molecules and their molecular ions. We identified all symmetric and asymmetric breakup channels for molecular ions up to N{sub 2}{sup 5+}, O{sub 2}{sup 4+}, and CO{sup 4+}. For each of those channels we measured the kinetic energy release (KER) spectra as a function of delay between the pump and probe pulses. For both N{sub 2} and O{sub 2} the asymmetric (3,1) channel is only observed for short (<20 fs) delays and completely disappears after that. We interpret this observation as a signature of electron localization taking place in dissociating molecular tri-cations when their internuclear separation reaches about 2.5 times the equilibrium bond length. This is a direct confirmation that electron localization plays an essential role in the universal mechanism of enhanced ionization in homonuclear diatomic molecules. Using classical and quantum mechanical simulations of the time-dependent KER spectra, we identify the pathways and intermediate states involved in the laser-induced dissociation of those molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cosmic Background Rejection of the ICARUS experiment at Fermilab

The Short Baseline Neutrino program at Fermilab aims to explore significant regions of parameter space, applicable to sterile neutrinos at the eV mass scale, as suggested by existing experimental anomalies. To this purpose it exploits Liquid Argon Time Projection Chamber detectors located along the Booster Neutrino Beamline to measure both νe appearance and νµ disappearance: the Short Baseline Neutrino Detector and the ICARUS-T600 detector at 110 and 600 m from the neutrino source, respectively. The ICARUS T-600 Far Detector, located at shallow depth, is surrounded by a Cosmic Ray Tagger system to mitigate the cosmic ray background. On average ~ 11 muon tracks are expected to cross the detector during the ~ 1 ms drift time. The cosmic ray tagger is composed of plastic scintillator bars, ensuring near 4π coverage of the detector aiming at tagging cosmic muons and thus reject 𝛾s produced by muon interactions in the surrounding materials that can generate an electromagnetic showers mimicking a νe signal. The system allows one to disentangle cosmic rays from particles originated in a neutrino interaction inside the detector by measuring their position and crossing time. A synchronization of the cosmic ray tagger with the ICARUS photon detection system with a nanosecond accuracy allows one to reject cosmic particles recorded during the beam spill and thus select an enriched sample of neutrino triggered events ahead of the event reconstruction. An overview of the cosmic ray tagger system as well as its role in the neutrino events identification and cosmic background rejection will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraining the evolutionary history of Newton's constant with gravitational wave observations

Space-borne gravitational wave detectors, such as the proposed Laser Interferometer Space Antenna, are expected to observe black hole coalescences to high redshift and with large signal-to-noise ratios, rendering their gravitational waves ideal probes of fundamental physics. The promotion of Newton's constant to a time function introduces modifications to the binary's binding energy and the gravitational wave luminosity, leading to corrections in the chirping frequency. Such corrections propagate into the response function and, given a gravitational wave observation, they allow for constraints on the first time derivative of Newton's constant at the time of merger. We find that space-borne detectors could indeed place interesting constraints on this quantity as a function of sky position and redshift, providing a constraint map over the entire range of redshifts where binary black hole mergers are expected to occur. A gravitational wave observation of an inspiral event with redshifted masses of 10{sup 4}-10{sup 5} solar masses for three years should be able to measure G/G at the time of merger to better than 10{sup -11} yr{sup -1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ALICE Electromagnetic Calorimeter

ALICE is the general purpose experiment at the LHC dedicated to the study of heavy-ion collisions. The electromagnetic calorimeter (EMCal) is a late addition to the ALICE suite of detectors with first modules installed in ALICE this year. The EMCal is designed to trigger on high energy gamma-rays and jets, and to enhance the capabilities of ALICE for these measurements. The EMCal is a Pb/scintillator sampling shish-kebab type calorimeter. The EMCal construction, readout, and performance in beam tests at the CERN SPS and PS are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum noise of a Michelson-Sagnac interferometer with a translucent mechanical oscillator

Quantum fluctuations in the radiation pressure of light can excite stochastic motions of mechanical oscillators thereby realizing a linear quantum opto-mechanical coupling. When performing a precise measurement of the position of an oscillator, this coupling results in quantum radiation pressure noise. Up to now this effect has not been observed yet. Generally speaking, the strength of radiation pressure noise increases when the effective mass of the oscillator is decreased or when the power of the reflected light is increased. Recently, extremely light SiN membranes ({approx_equal}100 ng) with high mechanical Q values at room temperature ({>=}10{sup 6}) have attracted attention as low thermal noise mechanical oscillators. However, the power reflectance of these membranes is much lower than unity (<0.4 at a wavelength of 1064 nm) which makes the use of advanced interferometer recycling techniques to amplify the radiation pressure noise in a standard Michelson interferometer inefficient. Here, we propose and theoretically analyze a Michelson-Sagnac interferometer that includes the membrane as a common end mirror for the Michelson interferometer part. In this topology, both power and signal recycling can be used even if the reflectance of the membrane is much lower than unity. In particular, signal recycling is a useful tool because it does not involve a power increase at the membrane. We derive the formulas for the quantum radiation pressure noise and the shot noise of an oscillator position measurement and compare them with theoretical models of the thermal noise of a SiN membrane with a fundamental resonant frequency of 75 kHz and an effective mass of125 ng. We find that quantum radiation pressure noise should be observable with a power of 1 W at the central beam splitter of the interferometer and a membrane temperature of 1 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diagnosing collisionless energy transfer using field–particle correlations: gyrokinetic turbulence

Determining the physical mechanisms that extract energy from turbulent fluctuations in weakly collisional magnetized plasmas is necessary for a more complete characterization of the behaviour of a variety of space and astrophysical plasmas. Such a determination is complicated by the complex nature of the turbulence as well as observational constraints, chiefly that in situ measurements of such plasmas are typically only available at a single point in space. Recent work has shown that correlations between electric fields and particle velocity distributions constructed from single-point measurements produce a velocity-dependent signature of the collisionless damping mechanism. We extend this work by constructing field–particle correlations using data sets drawn from single points in strongly driven, turbulent, electromagnetic gyrokinetic simulations to demonstrate that this technique can identify the collisionless mechanisms operating in such systems. The velocity-space structure of the correlation between proton distributions and parallel electric fields agrees with expectations of resonant mechanisms transferring energy collisionlessly in turbulent systems. This work motivates the eventual application of field–particle correlations to spacecraft measurements in the solar wind, with the ultimate goal to determine the physical mechanisms that dissipate magnetized plasma turbulence.

Physics↗

C IV EMISSION AND THE ULTRAVIOLET THROUGH X-RAY SPECTRAL ENERGY DISTRIBUTION OF RADIO-QUIET QUASARS

In the rest-frame ultraviolet (UV), two of the parameters that best characterize the range of emission-line properties in quasar broad emission-line regions are the equivalent width and the blueshift of the C IV {lambda}1549 line relative to the quasar rest frame. We explore the connection between these emission-line properties and the UV through X-ray spectral energy distribution (SED) for radio-quiet (RQ) quasars. Our sample consists of a heterogeneous compilation of 406 quasars from the Sloan Digital Sky Survey (at z > 1.54) and Palomar-Green survey (at z < 0.4) that have well-measured C IV emission-line and X-ray properties (including 164 objects with measured {Gamma}). We find that RQ quasars with both strong C IV emission and small C IV blueshifts can be classified as 'hard-spectrum' sources that are (relatively) strong in the X-ray as compared to the UV. On the other hand, RQ quasars with both weak C IV emission and large C IV blueshifts are instead 'soft-spectrum' sources that are (relatively) weak in the X-ray as compared to the UV. This work helps to further bridge optical/soft X-ray 'eigenvector 1' relationships to the UV and hard X-ray. Based on these findings, we argue that future work should consider systematic errors in bolometric corrections (and thus accretion rates) that are derived from a single mean SED. Detailed analysis of the C IV emission line may allow for SED-dependent corrections to these quantities.

79 ASTRONOMY AND ASTROPHYSICS↗

Soil architecture and subsurface stratigraphic heterogeneities across land-lake interfaces along Lake Erie.

Uploaded raw datasets from electrical resistivity tomography (ERT), ground penetrating radar (GPR), electromagnetic induction (EMI) and insitu sensors were acquired across land-lake interfaces along Lake Erie. These datasets were useful to delineate the soil architecture and subsurface stratigraphic heterogeneities. We combined multiple geophysical methods with lithostratigraphic logs from borehole cores and data from soil and borehole sensors to investigate spatial heterogeneities across land-lake interfaces. The apparent electrical conductivity (Eca) maps matched closely with the soil maps from public database and also detected additional soil units that were missing in the traditional soil maps. This implies that electromagnetic induction (EMI) could be relied upon for non invasive characterization of soils in sampling restricted sites where only non-invasive measurements are feasible. Results from electrical resistivity tomography (ERT) and Ground penetrating radar (GPR) are consistent with the surficial geology of the study area, and revealed that the vertical variabilities at the sites are mainly driven by stratigraphy.The ERT data (.stg) were acquired from three different sites portage river (PTR), crane creek (CRC) and old woman creek (OWC). The ".stg" files can be opened with ERT inversion software such as EarthImager, ResIpy or Res2DInv. The GPR data (.GPZ) were also acquired from the three sites, and the ".GPZ" data files can be opened with EKKO_project 5 software from Sensors & Software Inc., or with any other standard GPR software. The EM data (.csv) were acquired from the three sites while the soil sensor data (.csv) here were acquired only from crane creek site. The ".csv) files can be opened with MS Excel or any other spread sheet software.

54 ENVIRONMENTAL SCIENCES↗

Geometric phase in entangled systems: A single-neutron interferometer experiment

The influence of the geometric phase on a Bell measurement, as proposed by Bertlmann et al. [Phys. Rev. A 69, 032112 (2004)] and expressed by the Clauser-Horne-Shimony-Holt (CHSH) inequality, has been observed for a spin-path-entangled neutron state in an interferometric setup. It is experimentally demonstrated that the effect of geometric phase can be balanced by a change in Bell angles. The geometric phase is acquired during a time-dependent interaction with a radiofrequency field. Two schemes, polar and azimuthal adjustment of the Bell angles, are realized and analyzed in detail. The former scheme yields a sinusoidal oscillation of the correlation function S, dependent on the geometric phase, such that it varies in the range between 2 and 2{radical}(2) and therefore always exceeds the boundary value 2 between quantum mechanic and noncontextual theories. The latter scheme results in a constant, maximal violation of the Bell-like CHSH inequality, where S remains 2{radical}(2) for all settings of the geometric phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IS THE BLACK HOLE IN GX 339-4 REALLY SPINNING RAPIDLY?

The wide-band Suzaku spectra of the black hole (BH) binary GX 339-4, acquired in 2007 February during the Very High state, were reanalyzed. Effects of event pileup (significant within approx3' of the image center) and telemetry saturation of the X-ray Imaging Spectrometer (XIS) data were carefully considered. The source was detected up to approx300 keV, with an unabsorbed 0.5-200 keV luminosity of 3.8 x 10{sup 38} erg s{sup -1} at 8 kpc. The spectrum can be approximated by a power law of photon index 2.7, with a mild soft excess and a hard X-ray hump. When using the XIS data outside 2' of the image center, the Fe K line appeared extremely broad, suggesting a high BH spin as already reported by Miller et al. based on the same Suzaku data and other CCD data. When the XIS data accumulation is further limited to >3' to avoid event pileup, the Fe K profile becomes narrower, and a marginally better solution appears which suggests that the inner disk radius is 5-14 times the gravitational radius (1sigma), though a maximally spinning BH is still allowed by the data at the 90% confidence level. Consistently, the optically thick accretion disk is inferred to be truncated at a radius 5-32 times the gravitational radius. Thus, the Suzaku data allow an alternative explanation without invoking a rapidly spinning BH. This inference is further supported by the disk radius measured previously in the High/Soft state.

79 ASTRONOMY AND ASTROPHYSICS↗

Tau flavored dark matter and its impact on tau Yukawa coupling

In this paper we perform a systematic study of the tau flavored dark matter (DM) model by introducing two kinds of mediators (a scalar doublet and a charged scalar singlet). The electromagnetic properties of the DM, as well as their implications in DM direct detections, are analyzed in detail. The model turns out contributing a significant radiative correction to the tau lepton mass, in addition to loosing the tension between the measured DM relic density and constraints of DM direct detections. The loop corrections can be O(10%) of the total tau mass. Signal rates of the Higgs measurements from the LHC in the h →τ τ and h → γ γ channels, relative to the Standard Model expectations, can be explained in this model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton form factors and two-photon exchange in elastic electron-proton scattering

Proton electromagnetic form factors are among the most important sources of information about the internal structure of the proton. Two different methods for measuring these form factors, the method proposed by Rosenbluth and the polarization-transfer method, yield contradictory results. It is assumed that this contradiction can be removed upon taking into account the hard part of the contribution of two-photon exchange to the cross section for elastic electron-proton scattering. This contribution can measured experimentally via a precision comparison of the cross sections for the elastic scattering of positrons and electrons on protons. Such a measurement, performed at the VEPP-3 storage ring in Novosibirsk at the beam energies of 1.6 and 1.0 GeV for positron (electron) scattering angles in the ranges of θ{sub e} = 15°–25° and 55°–75° in the first case and in the range of θ{sub e} = 65°–105° in the second case is described in the present article. Preliminary results of this experiment and their comparison with theoretical predictions are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Acceleration Mechanism Of Pulsed Laser-Electromagnetic Hybrid Thruster

A fundamental study of a newly developed rectangular pulsed laser-electromagnetic hybrid thruster was conducted. Laser-ablation plasma in the thruster was induced through laser beam irradiation onto a solid target and accelerated by electrical means instead of direct acceleration only by using a laser beam. The performance of the thrusters was evaluated by measuring the ablated mass per pulse and impulse bit. As results, significantly high specific impulses up to 7,200 s were obtained at charge energies of 8.6 J. Moreover, from the Faraday cup measurement, it was confirmed that the speed of ions was accelerated with addition of electric energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE FIRST DETECTION OF [O IV] FROM AN ULTRALUMINOUS X-RAY SOURCE WITH SPITZER. II. EVIDENCE FOR HIGH LUMINOSITY IN HOLMBERG II ULX

This is the second of two papers examining Spitzer Infrared Spectrograph observations of the ultraluminous X-ray source (ULX) in Holmberg II. Here, we perform detailed photoionization modeling of the infrared lines. Our analysis suggests that the luminosity and morphology of the [O IV] 25.89 mum emission line is consistent with photoionization by the soft X-ray and far ultraviolet (FUV) radiation from the accretion disk of the binary system and inconsistent with narrow beaming. We show that the emission nebula is matter-bounded both in the line-of-sight direction and to the east, and probably radiation-bounded to the west. A bolometric luminosity in excess of 10{sup 40} erg s{sup -1} would be needed to produce the measured [O IV] flux. We use modeling and previously published studies to conclude that shocks likely contribute very little, if at all, to the high-ionization line fluxes observed in the Holmberg II ULX. Additionally, we find that the spectral type of the companion star has a surprisingly strong effect on the predicted strength of the [O IV] emission. This finding could explain the origin of [O IV] in some starburst systems containing black hole binaries.

79 ASTRONOMY AND ASTROPHYSICS↗