Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

The Design, Implementation, and Performance of the Astro-H SXS Aperture Assembly and Blocking Filters

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The properties that make the SXS array a powerful x-ray spectrometer also make it sensitive to photons from the entire electromagnetic band, and particles as well. If characterized as a bolometer, it would have a noise equivalent power (NEP) of less than 4x10(exp -18) W/(Hz)0.5(exp 0.5). Thus it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. Additionally, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. Both of these needs are addressed by a series of five thin-film radiation-blocking filters, anchored to the nested temperature stages, that block long-wavelength radiation while minimizing x-ray attenuation. The aperture assembly is a system of barriers, baffles, filter carriers, and filter mounts that supports the filters and inhibits their potential contamination. The three outer filters also have been equipped with thermometers and heaters for decontamination. We present the requirements, design, implementation, and performance of the SXS aperture assembly and blocking filters.

radiation - blocking filters↗

Scientific Considerations for Future Spectroscopic Measurements from Space of Activity on the Sun

High-resolution UV and X-ray spectroscopy are important to understanding the origin and evolution of magnetic energy release in the solar atmosphere, as well as the subsequent evolution of heated plasma and accelerated particles. Electromagnetic radiation is observed from plasma heated to temperatures ranging from about 10 k K to above 10 MK, from accelerated electrons emitting photons primarily at X-ray energies, and from ions emitting in gamma rays. These observations require space-based instruments sensitive to emissions at wavelengths shorter than the near UV. This article reviews some recent observations with emphasis on solar eruptive events, the models that describe them, and the measurements they indicate are needed for substantial progress in the future. Specific examples are discussed demonstrating that imaging spectroscopy with a cadence of seconds or better is needed to follow, understand, and predict the evolution of solar activity. Critical to substantial progress is the combination of a judicious choice of UV, EUV, and soft X-ray imaging spectroscopy sensitive to the evolution of this thermal plasma combined with hard X-ray imaging spectroscopy sensitive to suprathermal electrons. The major challenge will be to conceive instruments that, within the bounds of possible technologies and funding, have the flexibility and field of view to obtain spectroscopic observations where and when events occur while providing an optimum balance of dynamic range, spectral resolution and range, and spatial resolution.

Holman, Gordon D.↗

Long-term monitoring of ULF electromagnetic fields at Parkfield, CA

Electric and magnetic fields in the (10{sup -4}-1.0) Hz band were monitored at two sites adjacent to the San Andreas Fault near Parkfield and Hollister, California from 1995 to present. A data window [2002-2005], enclosing the September 28, 2004 M6 Parkfield earthquake, was analyzed to determine if anomalous electric or magnetic fields, or changes in ground conductivity, occurred before the earthquake. The data were edited, removing intervals of instrument malfunction leaving 875 days in the four-year period. Frequent, spike-like disturbances were common, but were not more frequent around the time of the earthquake; these were removed before subsequent processing. Signal to noise amplitude spectra, estimated via magnetotelluric processing showed the behavior of the ULF fields to be remarkably constant over the period of analysis. These first-order plots make clear that most of the recorded energy is coherent over the spatial extent of the array. Three main statistical techniques were employed to separate local anomalous electrical or magnetic fields from the dominant coherent natural fields: transfer function estimates between components at each site were employed to subtract the dominant field, and look deeper at the 'residual' fields; the data were decomposed into principal components to identify the dominant coherent array modes; and the technique of canonical coherences was employed to distinguish anomalous fields which are spatially broad from anomalies which occur at a single site only, and furthermore to distinguish anomalies which are present in both the electric and magnetic fields from those which are present in only one field type. Standard remote reference apparent resistivity estimates were generated daily at Parkfield. A significant seasonal component of variability was observed suggesting local distortion due to variations in near surface resistance. In all cases, high levels of sensitivity to subtle electromagnetic effects were demonstrated, but no effects which can be reasonably characterized as precursors to the Parkfield earthquake were found.

54 ENVIRONMENTAL SCIENCES↗

Magnetic diagnostics for equilibrium reconstructions in the presence of nonaxisymmetric eddy current distributions in tokamaks (invited)

The lithium tokamak experiment (LTX) is a modest-sized spherical tokamak (R{sub 0}=0.4 m and a=0.26 m) designed to investigate the low-recycling lithium wall operating regime for magnetically confined plasmas. LTX will reach this regime through a lithium-coated shell internal to the vacuum vessel, conformal to the plasma last-closed-flux surface, and heated to 300-400 deg. C. This structure is highly conductive and not axisymmetric. The three-dimensional nature of the shell causes the eddy currents and magnetic fields to be three-dimensional as well. In order to analyze the plasma equilibrium in the presence of three-dimensional eddy currents, an extensive array of unique magnetic diagnostics has been implemented. Sensors are designed to survive high temperatures and incidental contact with lithium and provide data on toroidal asymmetries as well as full coverage of the poloidal cross-section. The magnetic array has been utilized to determine the effects of nonaxisymmetric eddy currents and to model the start-up phase of LTX. Measurements from the magnetic array, coupled with two-dimensional field component modeling, have allowed a suitable field null and initial plasma current to be produced. For full magnetic reconstructions, a three-dimensional electromagnetic model of the vacuum vessel and shell is under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Imaging and Coherence Beamline I13 at Diamond

The coherence and imaging beamline I13 is dedicated to hard x-ray imaging on the micro- and nano-lengthscale, performing microscopy either in direct or reciprocal space. For both, lens-based and lensless imaging, two independent stations will be operated in a separate building at a distance of 250 m from the source. The imaging branch will perform in-line phase contrast imaging and tomography over a large field of view in the 6- to 35-keV energy range. In addition, it will be possible to switch to full-field microscopy with 50-nm spatial resolution. Other microscopies will be developed according to the scientific needs. Resolution beyond the limitations given by the detector and x-ray optics will be achieved with techniques working in the far field. Coherent x-ray diffraction (CXRD) and other coherent diffraction imaging techniques such as ptychography will also be implemented on the same 'coherence' branch. The beamline hosts a number of innovative features such as the so-called 'mini-beta' layout for electron optics in the storage ring or new concepts for beamline instrumentation. The stations will be operational in 2011.

43 PARTICLE ACCELERATORS↗

Mapping gravitational lensing of the CMB using local likelihoods

We present a new estimation method for mapping the gravitational lensing potential from observed CMB intensity and polarization fields. Our method uses Bayesian techniques to estimate the average curvature of the potential over small local regions. These local curvatures are then used to construct an estimate of a low pass filter of the gravitational potential. By utilizing Bayesian/likelihood methods one can easily overcome problems with missing and/or nonuniform pixels and problems with partial sky observations (E- and B-mode mixing, for example). Moreover, our methods are local in nature, which allow us to easily model spatially varying beams, and are highly parallelizable. We note that our estimates do not rely on the typical Taylor approximation which is used to construct estimates of the gravitational potential by Fourier coupling. We present our methodology with a flat sky simulation under nearly ideal experimental conditions with a noise level of 1 {mu}K-arcmin for the temperature field, {radical}(2) {mu}K-arcmin for the polarization fields, with an instrumental beam full width at half maximum (FWHM) of 0.25 arcmin.

79 ASTRONOMY AND ASTROPHYSICS↗

The NOvA Test Beam Program

NOvA is a long-baseline oscillation neutrino experiment designed to study and measure a wide range of important topics for neutrino physics such as the neutrino mixing parameters, the neutrino mass hierarchy, and CP violation in the lepton sector. The NOvA Test Beam experiment uses a scaled-down detector of 30 tons to analyze tagged beamline particles. A new tertiary beamline deployed at Fermilab can select and identify electrons, muons, pions, kaons and protons with momenta from 0.2 to 2 GeV/c. Using these data, the Test Beam program will provide NOvA with a better understanding of the largest systematic uncertainties impacting the analyses, including the detector response, calibration, and hadronic and electromagnetic energy resolution. The status and future plans for the NOvA Test beam program, along with preliminary results, are presented in these Proceedings.

43 PARTICLE ACCELERATORS↗

EMI / EMC Design for Class D Payloads (Resource Prospector / NIRVSS)

EMI/EMC techniques are applied to a Class D instrument (NIRVSS) to achieve low noise performance and reduce risk of EMI/EMC testing failures and/or issues during system integration and test. Basic techniques are not terribly expensive or complex, but do require close coordination between electrical and mechanical staff early in the design process. Low-cost methods to test subsystems on the bench without renting an EMI chamber are discussed. This method was applied to the NIRVSS instrument and achieved improvements up to 59dB on conducted emissions measurements between hardware revisions.

low noise↗

Signal enhancement using a switchable magnetic trap

A system for analyzing a sample including providing a microchannel flow channel; associating the sample with magnetic nanoparticles or magnetic polystyrene-coated beads; moving the sample with said magnetic nanoparticles or magnetic polystyrene-coated beads in the microchannel flow channel; holding the sample with the magnetic nanoparticles or magnetic polystyrene-coated beads in a magnetic trap in the microchannel flow channel; and analyzing the sample obtaining an enhanced analysis signal. An apparatus for analysis of a sample includes magnetic particles connected to the sample, a microchip, a flow channel in the microchip, a source of carrier fluid connected to the flow channel for moving the sample in the flow channel, an electromagnet trap connected to the flow line for selectively magnetically trapping the sample and the magnetic particles, and an analyzer for analyzing the sample.

47 OTHER INSTRUMENTATION↗

Systems and methods for locating and imaging proppant in an induced fracture

Born Scattering Inversion (BSI) systems and methods are disclosed. A BSI system may be incorporated in a well system for accessing natural gas, oil and geothermal reserves in a geologic formation beneath the surface of the Earth. The BSI system may be used to generate a three-dimensional image of a proppant-filled hydraulically-induced fracture in the geologic formation. The BSI system may include computing equipment and sensors for measuring electromagnetic fields in the vicinity of the fracture before and after the fracture is generated, adjusting the parameters of a first Born approximation model of a scattered component of the surface electromagnetic fields using the measured electromagnetic fields, and generating the image of the proppant-filled fracture using the adjusted parameters.

02 PETROLEUM↗

Optical phased array using guided resonance with backside reflectors

Methods and systems for controlling the phase of electromagnetic waves are disclosed. A device can consist of a guided resonance grating layer, a spacer, and a reflector. A plurality of devices, arranged in a grid pattern, can control the phase of reflected electromagnetic phase, through refractive index control. Carrier injection, temperature control, and optical beams can be applied to control the refractive index.

47 OTHER INSTRUMENTATION↗

Polarized Positive and Negative Muon Beams to perform DVCS Measurements at COMPASS

The high energies available at CERN, and the option of using either positive or negative polarized muon beams, make the fixed-target COMPASS set-up a unique place for studying GPDs, through Deeply Virtual Compton Scattering (DVCS). A GPD program is part of the Medium and Long Term Plans at COMPASS [1]. This contribution presents the methodology and the goal of such experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Strangeonia in Photoproduction using CLAS

The HyCLAS experiment at Jefferson Lab is a program to search for new and unusual mesons produced via photoproduction. The strangeonia sector is poorly known and a main component of this program is a search for new strangeonium states. The reaction {gamma}p{yields}p{phi}{eta} is an ideal channel to look for strangeonium states due to the strangeness content of both the {phi} and {eta}. The data was acquired at the JLAB CLAS facility using a 4-5.5 GeV tagged photon beam. The {phi} meson is identified via the K{sup +}K- decay. The recoil proton is observed in the CLAS spectrometer and the {eta} meson is identified through the missing mass. Also of interest is the search for strangeonia decaying to {phi}{pi}{sup 0} and {phi}{omega}. These channels are OZI suppressed for qq-bar mesons and an observation of a meson decaying to these channels would provide a strong evidence of mesons beyond qqa-bar. Preliminary results describing the data quality, kinematics and dynamics will be shown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Weakly Interacting Sub-eV Particle Searches

We make use of the generation-regeneration or 'light shining through a wall' technique in searches for optical-wavelength photons mixing with hypothetical hidden-sector paraphotons in the mass range between 10{sup -5} and 10{sup -2} electron volts for a mixing parameter greater than 10{sup -7} and in sensitive searches for scalar and pseudoscalar coupling of photons to light neutral bosons in the mass range of approximately 1.0 milli-electron volts and coupling strength greater than 10{sup -6} GeV{sup -1}. Additionally, there is an effort underway to use photons in the microwave region using this same technique to make a more sensitive measurement in the mass range of approximately 0.1 milli-electron volts. The equipment in the latter effort will be used to search for galactic halo axions in this same mass range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray Emission from Electron Betatron Motion in a Laser-Plasma Accelerator

Single-shot x-ray spectra from electron bunches produced by a laser-plasma wakefield accelerator (LPA) were measured using a photon-counting single-shot pixelated Silicon-based detector [3], providing for the first time direct spectra without assumptions required by filter based techniques. In addition, the electron bunch source size was measured by imaging a wire target, demonstrating few micron source size and stability. X-rays are generated when trapped electrons oscillate in the focusing field of the wake trailing the driver laser pulse. In addition to improving understanding of bunch emittance and wake structure, this provides a broadband, synchronized femtosecond source of keV x-rays. Electron bunch spectra and divergence were measured simultaneously and preliminary analysis shows correlation between x-ray andelectron spectra. Bremsstrahlung background was managed using shielding and magnetic diversion.

43 PARTICLE ACCELERATORS↗

Far-ultraviolet signatures of the {sup 3}He(n,tp) reaction in noble gas mixtures

Previous work showed that the {sup 3}He(n,tp) reaction in a cell of {sup 3}He at atmospheric pressure generated tens of far-ultraviolet photons per reacted neutron. Here we report amplification of that signal by factors of 1000 and more when noble gases are added to the cell. Calibrated filter-detector measurements show that this large signal is due to noble gas excimer emissions and that the nuclear reaction energy is converted to far-ultraviolet radiation with efficiencies of up to 30%. The results have been placed on an absolute scale through calibrations at the NIST SURF III synchrotron. They suggest possibilities for high-efficiency neutron detectors as an alternative to existing proportional counters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Aplanatic Three-Mirror Objective for High-Magnification Soft X-Ray Microscopy

An innovative solution for high-magnification microscopy, based on attaching afocal optics for focal length reduction, is proposed. The solution, consisting of three spherical mirrors, allows one to enhance a magnification of a laboratory based soft x-ray microscope over 1000x, where movies with diffraction-limited resolution can be observed with an x-ray CCD. The design example, having a numerical aperture of 0.25, was successfully demonstrated both a high magnification and a large field of view.

07 ISOTOPE AND RADIATION SOURCES↗