Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using standard calibrated geometries to characterize a coaxial high purity germanium gamma detector for Monte Carlo simulations

A detector model optimization procedure based on matching Monte Carlo simulations with measurements for two experimentally calibrated sample geometries which are frequently used in radioactivity measurement laboratories results in relative agreement within 5% between simulated and measured efficiencies for a high purity germanium detector. The optimization procedure indicated that the increase in dead layer thickness is largely responsible for a detector efficiency decrease in time. The optimized detector model allows Monte Carlo efficiency calibration for all other samples of which the geometry and bulk composition is known. The presented method is a competitive and economic alternative to more elaborate detector scanning methods and results in a comparable accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of AlGaN-Delta–GaN-Based UV Photodiodes in a Metal–Semiconductor–Metal Configuration for Efficient and Fast Solar Blind UV Sensing

Metal–semiconductor–metal (MSM) configured UV photodiodes (PD’s) were designed and fabricated on an AlGaN/GaN–based substrate for efficient and ultrafast UV detection. The purpose was to investigate the feasibility of obtaining efficient and ultrafast temporal response from these devices in the UV given the challenges associated with the formation of Schottky contacts on laterally oriented AlGaN/GaN thin films. Two sets of devices were implemented using Pt and Au as metal contacts with 5-µm finger width, 5-µm finger spacing, and a 50-µm x 50-µm active area. Spectral and voltage bias studies were done to establish the spectral profile and the effect of bias voltage on the responsivity of the detectors at 265 nm. Here, the best vertical MSM PD’s produced 0.6-A/W responsivity under 10-V bias voltage at 265 nm. Peak spectral responsivities were recorded as 1.35 A/W and 1.25 A/W at 240 nm for Pt and Au PD’s, respectively.

42 ENGINEERING↗

Test results from LAGEOS-2 optical characterization using pulsed lasers

The Laser Geodynamic Satellite-2 (LAGEOS-2) has undergone extensive optical testing at NASA Goddard Space Flight Center during 1989. The techniques included measuring the far field diffraction pattern using cw and pulsed lasers. In the pulsed measurement technique, response of the satellite was studied by measuring the far-field diffraction pattern (FFDP) as a function of pulsewidth, wavelength, polarization, position in the FFDP, detector/processing techniques, and satellite orientation. The purpose of the pulsed laser testing was two-fold: (1) to characterize the satellite optical response with the detector and signal processing electronics currently used in most SLR stations using the portable laser ranging standard, and (2) to characterize the satellite response for various conditions using the highest bandwidth optical detector (streak camera) available for the next generation of satellite laser ranging (SLR) technology. The portable ranging standard employed multiple measurement devices and an optical calibration scheme to eliminate range-dependent and amplitude-dependent systematics. These precautions were taken to eliminate/minimize instrumental errors and provide maximum accuracy. For LAGEOS orbit (6000 Km), ground stations are located 34 to 38 Mu radians off the axis of the return signal from the satellite; therefore, an optical mask was used to restrict the field of view (FOV) of detection to this annular region of the FFDP. The two measurement techniques were implemented using an aperture sharing scheme and complemented each other by providing mutual verification.

Varghese, Thomas K.↗

Characterization of Multianode Photomultiplier Tubes for use in the CLAS12 RICH detector

In this work, we present results of the detailed study of several hundred Hamamatsu H12700 Multianode Photomultiplier Tubes (MaPMTs), characterizing their response to the Cherenkov light photons in the second Ring Imaging Cherenkov detector, a part of the CLAS12 upgrade at Jefferson Lab. The total number of pixels studied was 25536. The single photoelectron spectra were measured for each pixel at different high voltages and light intensities of the laser test setup. Using the same dedicated front-end electronics as in the first RICH detector, the setup allowed us to characterize each pixel’s properties such as gain, quantum efficiency, signal crosstalk between neighboring pixels, and determine the signal threshold values to optimize their efficiency to detect Cherenkov photons. A recently published state-of-the-art mathematical model, describing photon detector response functions measured in low light conditions, was extended to include the description of the crosstalk contributions to the spectra. The database of extracted parameters will be used for the final selection of the MaPMTs, their arrangement in the new RICH detector, and the optimization of the operational settings of the front-end electronics. The results show that the characteristics of the H12700 MaPMTs satisfy our requirements for the position-sensitive single photoelectron detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton Scattering in NOvA Test Beam

The NuMI Off-axis $\nu_e$ Appearance (NOvA) experiment is a two-detector, long baseline, neutrino oscillation experiment, which aims to make a determination of the neutrino mass ordering, the octant of $\theta_{23}$, and measure possible charge-parity (CP) violation. Determining these parameters is a step towards answering some of the fundamental questions about neutrinos. Are neutrinos their own antiparticle? Could neutrinos be responsible for the matter-antimatter asymmetry of the universe? How do neutrinos get their mass? Answering these questions requires precise measurements of the parameters that govern how neutrinos behave, namely the mass squared splittings, mixing angles, and possible CP-violating phase factor in the PNMS matrix. Reaching high precision requires minimizing both statistical and systematic errors. As NOvA continues to accumulate data, the sizes of our statistical errors continue to shrink such that in a couple of years they will be comparable to our systematic errors. NOvA's current systematic errors are dominated by energy and calibration uncertainties. The Test Beam program was initiated to address these uncertainties by assessing the detector response in an environment where more parameters of the incoming particles are known. One of the main goals of the Test Beam program is to garner a better understanding of our systematic errors, particularly in energy measurement and detector response, so that the modeling of these parameters can be improved. I studied protons in the Test Beam Detector with momenta around \unit[1]{GeV/c}, the high end of the momentum range relevant to quasielastic neutrino interactions in NOvA. One question this sample can help to answer is if we correctly simulate the fraction of protons that have an inelastic scattering interaction versus ranging out. If protons inelastically scatter at different rates in our simulation and data, the correction applied to the hadronic system when reconstructing neutrino energy could be inaccurate, since events with inelastic scattering will have less visible energy in the detector. This is particularly important for quasielastic $\nu_\mu$ events, which have the lowest hadronic energy resolution, and therefore give us our best measurements of $\Delta m_{32}^2$ and $\theta_{23}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wavelength-shifting properties of luminescence nanoparticles for high energy particle detection and specific physics process observation

Here, ultraviolet (UV) photon detection is becoming increasingly important in the quest to understand the fundamental building blocks of our universe. Basic properties of neutrinos and Dark Matter are currently being explored through interactions with noble elements. In response to interactions with fundamental particles, these elements emit scintillation photons in the UV range. However, most available detectors have poor response in the UV so it is typically necessary to shift UV to a wavelength, matching the sensitivity of the viable detectors. We report on development of UV-enhanced photosensors using wavelength-shifting properties of nanoparticles. Several nanoparticle coatings were tested for absorption of UV light with subsequent emission in the visible wavelength for high energy particle detection. ZnS:Mn, Eu, ZnS: Mn, CuCy (Copper Cysteamine) and CdTe nanoparticles all exhibited enhanced detection for wavelengths in the range 200-320 nm in several different tests, while ZnS:Ag and CdS nanoparticle showed little or no enhancement in that range. In addition, various LaF3:Ce nanoparticle concentrations in approximately constant thickness of 2,5-diphenyloxazole (PPO)/polystyrene bases were also tested to optimize the nanoparticle concentration for the best outcome. Our studies indicated that ZnS:Mn, Eu, ZnS: Mn, Cu-Cy, CdTe and LaF 3 :Ce nanoparticles show potential for light detection from fundamental particle interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Localization of a radioactive source in an urban environment using Bayesian Metropolis methods [Bayesian Metropolis methods for source localization in an urban environment]

Here, we present a method for localizing an unknown source of radiation in an urban environment using a distributed detector network. This method employs statistical parameter estimation techniques, relying on an approximation for the response of a detector to the source based on a simplified model of the underlying transport phenomena, combined with a Metropolis-type sampler that is modified to propagate the effect of fixed epistemic uncertainties in the material macroscopic cross sections of objects in the scene. We apply this technique to data collected during a measurement campaign conducted in a realistic analog for an urban scene using a network of six mobile detectors. Our initial results are able to localize the source to within approximately 8 m over a scene of size 300 m 200 m in two independent trials with 30 min count times, including a characterization of the uncertainty associated with the poorly known macroscopic cross sections of objects in the scene. In these measurements, the nearest detectors were between 20 m to 30 m from the source, and recorded count rates between approximately 3 and 13 times background. A few detectors had line-of-sight to the source, while the majority were obscured by objects present in the scene. After extending our model to account for the orientation of the detectors and correcting for anomalies in the measurement data we were able to further improve the localization accuracy to approximately 2 m in both trials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of stop quark mass at the LHC

The cascade mass reconstruction approach was applied to simulated production of the lightest stop quark at the LHC in the cascade decay g-tilde{yields}t-tilde{sub 1}t{yields}{chi}-tilde{sub 2}{sup 0}tt{yields}l-tilde{sub R}ltt{yields}{chi}-tilde{sub 1}{sup 0}lltt with top quarks decaying into hadrons. The stop quark mass was reconstructed assuming that the masses of gluino, slepton, and the two lightest neutralinos were reconstructed in advance. A data sample set for the SU3 model point containing 400 k supersymmetry events was generated which corresponded to an integrated luminosity of about 20 fb{sup -1} at 14 TeV. These events were passed through the AcerDET detector simulator, which parametrized the response of a generic LHC detector. The mass of the t-tilde{sub 1} was reconstructed with a precision of about 10%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction of {tau}-tilde{sub 1} mass at the LHC

The cascade mass reconstruction approach was used for mass reconstruction of the lightest {tau}-tilde produced at the LHC in the cascade decay g-tilde {yields} b-tildeb {yields} {chi}-tilde{sub 2}{sup 0}bb {yields} {tau}-tilde{sub 1}{tau}bb {yields} {chi}-tilde{sub 1}{sup 0}{tau}{tau}bb. The {tau}-tilde{sub 1} mass was reconstructed assuming that masses of gluino, bottom squark, and two lightest neutralinos were reconstructed in advance. SUSY data sample sets for the SU(3) model point containing 160k events each were generated which corresponded to an integrated luminosity of about 8 fb{sup -1} at 14 TeV. These events were passed through the AcerDET detector simulator, which parametrized the response of a generic LHC detector. The mass of the {tau}-tilde{sub 1} was reconstructed with a precision of about 20% on average.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray remote sensing and in-situ spectroscopy for planetary exploration missions and gamma-ray remote sensing and in-situ spectroscopy for planetary exploration missions

Detectors that will be used for planetary missions must have their responses calibrated in a reproducible manner. A calibration facility is being constructed at Schlumberger-Doll Research for gamma and x ray detectors. With this facility the detector response can be determined in an invariant and reproducible fashion. Initial use of the facility is expected for the MARS94 detectors. Work is continuing to better understand the rare earth oxyorthosilicates and to define their characteristics. This will allow a better use of these scintillators for planetary missions. In a survey of scintillating materials two scintillators were identified as promising candidates besides GSO, LSO, and YSO. These are CdWO4 and CsI(Tl). It will be investigated if a detector with a better overall performance can be assembled with various photon converters. Considerable progress was achieved in photomultiplier design. The length of an 1 inch diameter PMT could be reduced from 4.2 to 2.5 inches without performance degradation. This technology is being employed in the gamma ray detector for the NEAR project. A further weight and size reduction of the detector package can be achieved with miniaturized integrated power supplies.

Mahdavi, M.↗

Design and performance of an Automatic Gain Control system for the High Energy X-Ray Timing Experiment

The High Energy X-Ray Timing Experiment (HEXTE), currently under development for the X-Ray Timing Explorer (XTE) mission, employs a closed loop gain control system to attain 0.5 percent stabilization of each of eight-phoswich detector gains. This Automatic Gain Control (AGC) system utilizes a split window discriminator scheme to control the response of each detector pulse height analyzer to gated Am-241 X-ray events at 60 keV. A prototype AGC system has been implemented and tested within the gain perturbation environment expected to be experienced by the HEXTE instrument in flight. The AGC system and test configuration are described. Response, stability and noise characteristics are measured and compared with theoretical predictions. The system is found to be generally suitable for the HEXTE application.

Pelling, Michael R.↗

Understanding the SNO+ Detector

SNO+, a large liquid scintillator experiment, is the successor of the Sudbury Neutrino Observatory (SNO) experiment. The scintillator volume will be loaded with large quantities of 130 Te, an isotope that undergoes double beta decay, in order to search for neutrinoless double beta decay. In addition to this search, SNO+ has a broad physics program due to its sensitivity to solar and supernova neutrinos, as well as reactor and geo anti-neutrinos. SNO+ can also place competitive limits on certain modes of invisible nucleon decay during its first phase. The detector is currently undergoing commissioning in preparation for its first phase, in which the detector is filled with ultra pure water. This will be followed by a pure scintillator phase, and then a Tellurium-loaded scintillator phase to search for neutrinoless double beta decay. Here we present the work done to model detector aging, which was first observed during SNO. The aging was found to reduce the optical response of the detector. We also describe early results from electronics calibration of SNO+.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of quasi-elastic scattering in the NOνA near detector prototype

NOvA is a 14 kTon long-baseline neutrino oscillation experiment currently being installed in the NuMI off-axis neutrino beam produced at Fermilab. A 222 Ton prototype NOνA detector was built and operated in the neutrino beam for over a year to understand the response of the detector and its construction. Muon neutrino interaction data collected in this test are being analyzed to identify quasi-elastic charged-current interactions and measure the behavior of the quasi-elastic muon neutrino cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation of Particle-Material Interactions

This paper gives an overview of the particle transport theory essentials, the basics of particle-material interaction simulation, physical quantities needed to simulate particle transport and interactions in materials, Monte Carlo simulation flow, response of additive detectors, statistical weights and other techniques to minimize statistical errors. Effects in materials under irradiation, materials response related to component lifetime and performance are considered with a focus on high-energy and high-power accelerator applications. Implementation of simulation of particle-material interactions in the modern Monte Carlo codes along with the code s main features and results of recent benchmarking are described.

43 PARTICLE ACCELERATORS↗

The On-Orbit Calibrations for the Fermi Large Area Telescope

The Large Area Telescope (LAT) on-board the Fermi Gamma-ray Space Telescope began its on-orbit operations on June 23, 2008. Calibrations, defined in a generic sense, correspond to synchronization of trigger signals, optimization of delays for latching data, determination of detector thresholds, gains and responses, evaluation of the perimeter of the South Atlantic Anomaly (SAA), measurements of live time, of absolute time, and internal and spacecraft boresight alignments. Here we describe on-orbit calibration results obtained using known astrophysical sources, galactic cosmic rays, and charge injection into the front-end electronics of each detector. Instrument response functions will be described in a separate publication. This paper demonstrates the stability of calibrations and describes minor changes observed since launch. These results have been used to calibrate the LAT datasets to be publicly released in August 2009.

79 ASTRONOMY AND ASTROPHYSICS↗

A technique for verifying the input response function of neutron time-of-flight scintillation detectors using cosmic rays

An accurate interpretation of DD or DT fusion neutron time-of-flight (nTOF) signals from current mode detectors employed at the Z-facility at Sandia National Laboratories requires that the instrument response functions (IRF’s) be deconvolved from the measured nTOF signals. A calibration facility that produces detectable sub-ns radiation pulses is typically used to measure the IRF of such detectors. This work, however, reports on a simple method that utilizes cosmic radiation to measure the IRF of nTOF detectors, operated in pulse-counting mode. The characterizing metrics reported here are the throughput delay and full-width-at-half-maximum. This simple approach yields consistent IRF results with the same detectors calibrated in 2007 at a LINAC bremsstrahlung accelerator (Idaho State University). In particular, the IRF metrics from these two approaches and their dependence on the photomultipliers bias agree to within a few per cent. This information may thus be used to verify if the IRF for a given nTOF detector employed at Z has changed since its original current-mode calibration and warrants re-measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The (55)Fe X-ray Energy Response of Mercury Cadmium Telluride Near-Infrared Detector Arrays

The accurate determination of a detector's fundamental parameters, including read noise, dark current, and QE, relies on a proper measurement of a detector's conversion gain (e- ADU(exp -1)). Charge coupling effects, such as interpixel capacitance, attenuate photon shot noise and result in an overestimation of conversion gain when implementing the photon transfer technique. An approach involving (55)Fe X-rays provides a potentially straightforward measurement of conversion gain by comparing the observed instrumental counts (ADU) to the known charge (e-) liberated by the X-ray. This technique is already preferred within the CCD community, as the pair production energy for silicon is well established. In contrast, to date the pair production energy is unknown for HgCdTe, a material commonly used for near-infrared detectors. In this paper, we derive a preliminary calibration of the (55)Fe X-ray energy response of HgCdTe using 8 HST WFC3 1.7 micrometers flight grade detectors. Our conversion of the X-ray intensities from counts into electrons implements a technique that restores the 'true' gain via classical propagation of errors. For these detectors, our analysis yields preliminary results of good statistical precision: each Ka event generates 1849 +/- 46 electrons, which corresponds to a pair production energy of 3.21+/-f 0.08 eV. We are continuing to assess potential systematic effects to further refine the accuracy of this result.

Fox, Ori↗