Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Electrochemically decorated gold nanoparticles on CVD graphene ChemFET sensor for the highly sensitive detection of As(III)

Here, in this paper, we report a novel reusable receptor-free chemically sensitive field-effect transistor (ChemFET) sensor for the sensitive detection of As(III) using electrochemical doping of Au nanoparticles (AuNPs)-chemical vapour deposition (CVD) graphene (Gr) sensing film (AuNPs-Gr). The sensor consists of a single-gap gold electrode and a single layer of CVD graphene as a conducting/sensing channel decorated with a thin layer of electrochemically deposited AuNPs to catalyze the electroreduction of As(III) ions onto the sensing channel. A new detection strategy was proposed by measuring the resistance change rate of the AuNPs-Gr sensing channel modified between the source electrode and drain electrode, wherein the resistance change was caused by the electrochemical doping of As(0). The results indicated that the electrochemical doping of As(0) onto the sensing channel led to an increase in resistance through the doping interaction among As(0), AuNPs and graphene, enabling the proposed sensor to have an extraordinary detection performance with a high sensitivity. Moreover, the proposed sensor can be recycled by removing the As(0) deposited on the sensing film with the aid of a simple electrochemical oxidization process. Additionally, the mechanism of the sensing strategy based on the electrochemical n-doping of As(0) into the AuNPs-Gr sensing film was investigated using a top liquid gate electrode. The As(III) concentration detected by the AuNPs-Gr ChemFET sensor was as low as 0.001 μg/L, demonstrating that such sensors with a compatible sensing strategy can be used to detect As(III) with high sensitivity, easy fabrication, fast response and can be recycled.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity analysis of high resolution gamma-ray detection for safeguards monitoring at natural uranium conversion facilities

Under the policies proposed by recent International Atomic Energy Agency (IAEA) circulars and policy papers, implementation of safeguards exists when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed in previous work to develop and validate gamma-ray nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UO 2 (NO 3 ) 2 ) solution exiting solvent extraction was identified as a key measurement point (KMP). Passive nondestructive assay techniques using high resolution gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely manner. Building upon the aforementioned previous validation work on detector sensitivity to varying concentrations of uranyl nitrate via a series of dilution measurements, this work investigates detector response parameter sensitivities to gamma-ray signatures of uranyl nitrate. The full energy peak efficiency of a detection system is dependent upon the sample, geometry, absorption, and intrinsic efficiency parameters. Perturbation of these parameters translates into corresponding variations of the 185.7 keV peak area of the 235 U in uranyl nitrate. Such perturbations in the assayed signature impact the quality or versatility of the safeguards conclusions drawn. Given the potentially high throughput of uranyl nitrate in NUCPs, the ability to assay 1 SQ of material requires uncertainty «1%. Accounting for material self-shielding properties, pipe thickness, and source-detector orientation is instrumental in determining the robustness of gamma-ray detection in the process monitoring of uranyl nitrate in NUCPs. Monte Carlo models and ray-tracing models were employed to determine the sensitivity of the detected 185.7 keV photon to self-shielding properties, pipe thickness, and source-detector geometry. Considering the implementation of the detection of 1 SQ, diversion of 1 SQ becomes essentially undetectable given the systematic uncertainty, in addition to considerations such as propagating uncertainties due to pipe offset/position, as well as minor variations in pipe thickness. Consequently, pipe thickness was the most sensitive variable in affecting full energy efficiency of the 185.7 keV signature peak with up to 8% variation in efficiency for ±0.5 mm changes in Schedule 40 304L stainless steel piping. Furthermore, computation of the attenuation correction factor of the uranyl nitrate solution [CF(AT) (i.e. εsample)] using Parker's method using with the approximation for the geometrical factor κ≈π/4 was validated through experimental, Monte Carlo and ray-tracing calculations for a uranyl nitrate filled transfer pipe segment. Furthermore, quantifying sensitivity in detector position, as well as voiding effects due to bubbly flow or laminar flow with an air gap in the uranyl nitrate becomes increasingly important as considerations from (static) design-scale measurements translate into (dynamic) field operations tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of sub-500-μm cracks in multicrystalline silicon wafer using edge-illuminated dark-field imaging to enable thin solar cell manufacturing

High capital expenditures associated with manufacturing thin silicon wafers make it difficult for the industry to scale up and prevent novel technologies from entering the market. Thin wafers fail largely due to breakage during solar cell processing and handling. One of the root causes for breakage is sub-mm edge cracks in the silicon wafer, and these cracks cannot be reliably detected by most commercially-available crack detection tools. In this work, we first investigate the correlation between wafer thickness and critical crack length, and explain the importance of detecting sub-500-μm edge cracks as the wafer thickness is reduced. Secondly, we extend our previous work of micro-crack detection to demonstrate an edge illumination technique using a near-infrared laser to image edge cracks less than 500 μm in length in multicrystalline silicon. Thirdly, we investigate two fundamental edge illumination mechanisms based on dark-field imaging; namely, direct and vicinal illumination. We will then compare these methods to a state-of-the-art rear illumination method. The advantages and disadvantages of both illumination methods are presented and provide an in-depth analysis of light-crack interaction. In particular, we find that the robustness of vicinal illumination is due to diffuse reflectance. The diffuse reflectance has less dependence on crack configurations, while direct illumination has more dependence on the crack configurations because it utilizes specular reflectance. Our results show that our proposed prototype can detect sub-mm edge cracks in multicrystalline silicon wafers, which is an important step in enabling thin silicon wafer manufacturing.

14 SOLAR ENERGY↗

Combining fast magic angle spinning dynamic nuclear polarization with indirect detection to further enhance the sensitivity of solid-state NMR spectroscopy

Dynamic nuclear polarization (DNP) and indirect detection are two commonly applied approaches for enhancing the sensitivity of solid-state NMR spectroscopy. However, their use in tandem has not yet been investigated. With the advent of low-temperature fast magic angle spinning (MAS) probes with 1.3-mm diameter rotors capable of MAS at 40 kHz it becomes feasible to combine these two techniques. In this study, we performed DNP-enhanced 2D indirectly detected heteronuclear correlation (idHETCOR) experiments on 13 C, 15 N, 113 Cd and 89 Y nuclei in functionalized mesoporous silica, CdS nanoparticles, and Y 2 O 3 nanoparticles. The sensitivity of the 2D idHETCOR experiments was compared with those of DNP-enhanced directly-detected 1D cross polarization (CP) and 2D HETCOR experiments performed with a standard 3.2-mm rotor. Due to low CP polarization transfer efficiencies and large proton linewidth, the sensitivity gains achieved by indirect detection alone were lower than in conventional (non-DNP) experiments. Nevertheless, despite the smaller sample volume the 2D idHETCOR experiments showed better absolute sensitivities than 2D HETCOR experiments for nuclei with the lowest gyromagnetic ratios. Finally, for 89 Y, 2D idHETCOR provided 8.2 times better sensitivity than the 1 D 89 Y-detected CP experiment performed with a 3.2-mm rotor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An integrated electrochemical device based on immunochromatographic test strip and enzyme labels for sensitive detection of disease-related biomarkers

A novel electrochemical biosensing device that integrates an immunochromatographic test strip and a screen-printed electrode (SPE) connected to a portable electrochemical analyzer was presented for rapid, sensitive, and quantitative detection of disease-related biomarker in human blood samples. The principle of the sensor is based on sandwich immunoreactions between a biomarker and a pair of its antibodies on the test strip, followed by highly sensitive square-wave voltammetry (SWV) detection. Horseradish peroxidase (HRP) was used as a signal reporter for electrochemical readout. Hepatitis B surface antigen (HBsAg) was employed as a model protein biomarker to demonstrate the analytical performance of the sensor in this study. Some critical parameters governing the performance of the sensor were investigated in detail. The sensor was further utilized to detect HBsAg in human plasma with an average recovery of 91.3%. In comparison, a colorimetric immunochromatographic test strip assay (ITSA) was also conducted. The result shows that the SWV detection in the electrochemical sensor is much more sensitive for the quantitative determination of HBsAg than the colorimetric detection, indicating that such a sensor is a promising platform for rapid and sensitive point-of-care testing/screening of disease-related biomarkers in a large population

59 BASIC BIOLOGICAL SCIENCES↗

Rapid and Sensitive Detection of Protein Biomarker Using a Portable Fluorescence Biosensor based on Quantum Dots and a Lateral Flow Test Strip

A portable fluorescence biosensor with rapid and ultrasensitive response for trace protein has been built up with quantum dots and lateral flow test strip. The superior signal brightness and high photostability of quantum dots are combined with the promising advantages of lateral flow test strip and resulted in high sensitivity, selectivity and speedy for protein detection. Nitrated ceruloplasmin, a significant biomarker for cardiovascular disease, lung cancer and stress response to smoking, was used as model protein to demonstrate the good performances of this proposed Qdot-based lateral flow test strip. Quantitative detection of nitrated ceruloplasmin was realized by recording the fluorescence intensity of quantum dots captured on the test line. Under optimal conditions, this portable fluorescence biosensor displays rapid responses for nitrated ceruloplasmin in wide dynamic range with a detection limit of 0.1ng/mL (S/N=3). Furthermore, the biosensor was successfully utilized for spiked human plasma sample detection with the concentration as low as 1ng/mL. The results demonstrate that the quantum dot-based lateral flow test strip is capable for rapid, sensitive, and quantitative detection of nitrated ceruloplasmin and hold a great promise for point-of-care and in field analysis of other protein biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

Direct Real-Time Detection of Vapors from Explosive Compounds

The real-time detection of vapors from low volatility explosives including PETN, tetryl, RDX and nitroglycerine along with various compositions containing these substances is demonstrated. This was accomplished with an atmospheric flow tube (AFT) using a non-radioactive ionization source and coupled to a mass spectrometer. Direct vapor detection was demonstrated in less than 5 seconds at ambient temperature without sample pre-concentration. The several seconds of residence time of analytes in the AFT provides a significant opportunity for reactant ions to interact with analyte vapors to achieve ionization. This extended reaction time, combined with the selective ionization using the nitrate reactant ions (NO3- and NO3-•HNO3), enables highly sensitive explosives detection. Observed signals from diluted explosive vapors indicate detection limits below 10 ppqv using selected ion monitoring (SIM) of the explosive-nitrate adduct at m/z 349, 378, 284 and 289 for tetryl, PETN, RDX and NG respectively. Also provided is a demonstration of the vapor detection from 10 different energetic formulations, including double base propellants, plastic explosives and commercial blasting explosives using SIM for the NG, PETN and RDX product ions.

atmospheric pressure ionization↗

Detection of Inorganic Salt-Based Homemade Explosives (HME) by Atmospheric Flow Tube–Mass Spectrometry

Using a commercial mass spectrometer interfaced with an atmospheric flow tube (AFT) allowed detection of a variety of inorganic compounds used as oxidizers in homemade explosives at picogram levels. The AFT provides reaction times between 3-5 seconds with flows of 6 L/min, enabling detection levels, after thermal desorption, similar to those previously demonstrated for RDX vapors in the low parts-per-quadrillion range. The thermal desorption of chlorate and perchlorate salts resulted in the production of the corresponding anions which have higher electron affinities than the nitrate reactant ions. A dielectric barrier discharge, used as the ionization source, produced the nitrate reactant ions. In some instances, the molecular salt formed adducts with the nitrate, chlorate, and/or perchlorate anions, giving insight into the original identity of the salt cation. Urea nitrate, guanidine nitrate, and potassium nitrate were also detected as adducts with the nitrate reactant ion. Direct room-temperature vapor detection of urea nitrate and hydrogen peroxide, which have relatively high vapor pressures compared to the other salts in this study, is also demonstrated. Room-temperature vapor detection of chlorate and perchlorate salts is possible by the addition of a dilute acid which converts the salt into a more volatile acidic form. A discussion of the instrumentation, methods used, and the ionization chemistry is provided.

chlorate, perchlorate, nitrate, detection, hydroge↗

Potential Source Apportionment and Meteorological Conditions Involved in Airborne 131 I Detections in January/February 2017 in Europe

Traces of particulate radioactive iodine (I-131) were detected in the European atmosphere in January/February 2017. Concentrations of this nuclear fission product were very low, ranging 0.1 to 10 mu Bq m(-3) except at one location in western Russia where they reached up to several mBq m(-3). Detections have been reported continuously over an 8-week period by about 30 monitoring stations. We examine possible emission source apportionments and rank them considering their expected contribution in terms of orders of magnitude from typical routine releases: radiopharmaceutical production units > sewage sludge incinerators > nuclear power plants > spontaneous fission of uranium in soil. Inverse modeling simulations indicate that the widespread detections of I-131 resulted from the combination of multiple source releases. Among them, those from radiopharmaceutical production units remain the most likely. One of them is located in Western Russia and its estimated source term complies with authorized limits. Other existing sources related to I-131 use (medical purposes or sewage sludge incineration) can explain detections on a rather local scale. As an enhancing factor, the prevailing wintertime meteorological situations marked by strong temperature inversions led to poor dispersion conditions that resulted in higher concentrations exceeding usual detection limits in use within the informal Ring of Five (Ro5) monitoring network.

54 ENVIRONMENTAL SCIENCES↗

Engineering a new tripartite split-ccGFP system from Corynactis californica for detecting protein–protein interactions

Protein-protein interactions (PPIs) are critical to a range of biological processes and, consequently, aberrant interactions are implicated in many disorders. The study of the complex networks of PPIs promises to elucidate undiscovered roles in cellular processes and the mechanisms of disease. To accomplish this, tools to effectively sense PPIs are necessary. Effective PPI sensors must rapidly detect interactions in real-time with high sensitivity without perturbing the proteins of interest (POIs) under study. Split fluorescent proteins have previously been used to successfully monitor PPIs, in part due to the small size of the tags. Here, we developed an optimized tripartite split GFP system based on Corynactis californica GFP (ccGFP) to detect PPIs in vitro. In this sensor system, ccGFP fragments ccGFP10 and ccGFP11 are tagged to two POIs. PPIs can then be detected via fluorescence by complementation to the third fragment, ccGFP1-9, which reconstitutes functional ccGFP. The optimized ccGFP system shows improved detection kinetics and pH and temperature stability compared to a previous system. We then validated the sensor by monitoring PPIs in two model systems: attractive/repulsive coiled-coils and rapamycin-inducible FRB/FKBP heterodimerization. Finally, we developed an anti-tripartite ccGFP single-chain variable fragment (scFv), which could enable versatile detection of identified protein-protein complexes.

59 BASIC BIOLOGICAL SCIENCES↗

DETECTION OF LACK OF FUSION WELD DEFECTS BY RADIOGRAPHY

In this work, radiography was employed as the NDT technique for detection of flaws in circumferential girth welds of steel pipelines used in offshore installations in the petroleum industry. The kind of defect specifically focused was lack of fusion. It is currently accepted in the literature that radiography is not as sensitive as ultrasonics to detect lack of fusion defects. Unfortunately, the radiographic inspection can barely detect lack of fusion and only when it is associated to inclusions and voids of considerable size. However, in a previous article ('Reliability of radiographic inspection of steel pipeline girth welds', QNDE Conference, 2007), the authors showed that it is possible to detect lack of fusion defects if, in the radiographic tests, the angle of incidence is the same angle that the weld bevel makes with the test piece surface, which means lowering the angle of disorientation between the flaw and the radiographic beam. However, no concerns were made to sizing the defects. Computational simulation was used with XRSIM software to establish the optimal radiographic parameters to reach the lower limit for detection for this kind of defect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Indirect detections and analyses of GRBs by ionospheric response

We report on the independent and indirect detection of GRBs by their ionospheric response (SID--Sudden Ionospheric Disturbance) observed at VLF (Very Low Frequency), and discus its possible impact on GRB science and investigations in general. Although few such detections have been already reported in the past, the capability of such alternative and indirect investigations of GRBs still remains to be investigated in more details. We present and discuss examples of such VLF/SID detection of GRBs 060124A, GRB080319D a GRB080320A. A network of SID monitors has been created and is operated to detect more GRBs. The importance of these detections for GRB analyses and GRB science in general is still to be further and in full detail exploited. Some possible outcomes in this direction will be outlined and discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Indirect detections and analyses of GRBs by ionospheric response

We present and discuss the independent and indirect detection of GRBs by their ionospheric response (SID--Sudden Ionospheric Disturbance) observed at VLF (Very Low Frequency), and evaluate its possible impact on GRB science and investigations in general. Although few such detections have been already reported in the past, the capability of such alternative and indirect investigations of GRBs still remains to be investigated in more details. We present and discuss examples of such VLF/SID detection of GRBs 060124A, GRB080319D a GRB080320A. A network of SID monitors has been created and is operated to detect more GRBs. The importance of these detections for GRB analyses and GRB science in general is still to be further and in full detail exploited.

79 ASTRONOMY AND ASTROPHYSICS↗

Surface Detection in a STXM Microscope

We have modified scanning transmission x-ray microscopes (STXM) at the Canadian Light Source and the Advanced Light Source with total electron yield (TEY) detection (TEY-STXM). This provides improved surface-sensitive detection, simultaneous with existing bulk-sensitive transmission detection in the STXM microscopes. We have explored sample-current and channeltron-based electron yield detection. Both approaches provide improved surface sensitive imaging and spectroscopy, although channeltron-based detection is superior. TEY-STXM provides surface sensitive imaging of ultrathin films such as phase-separated Langmuir-Blodgett monolayer films, as well as differentiation of surface and bulk oxides of patterned metallic thin films. This paper will outline the experimental challenges of this method and the opportunities for correlative surface and bulk measurements of complex samples.

07 ISOTOPE AND RADIATION SOURCES↗

A bubble detection system for propellant filling pipeline

This paper proposes a bubble detection system based on the ultrasound transmission method, mainly for probing high-speed bubbles in the satellite propellant filling pipeline. First, three common ultrasonic detection methods are compared and the ultrasound transmission method is used in this paper. Then, the ultrasound beam in a vertical pipe is investigated, suggesting that the width of the beam used for detection is usually smaller than the internal diameter of the pipe, which means that when bubbles move close to the pipe wall, they may escape from being detected. A special device is designed to solve this problem. It can generate the spiral flow to force all the bubbles to ascend along the central line of the pipe. In the end, experiments are implemented to evaluate the performance of this system. Bubbles of five different sizes are generated and detected. Experiment results show that the sizes and quantity of bubbles can be estimated by this system. Also, the bubbles of different radii can be distinguished from each other. The numerical relationship between the ultrasound attenuation and the bubble radius is acquired and it can be utilized for estimating the unknown bubble size and measuring the total bubble volume.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High repetition rate laser-induced breakdown spectroscopy using acousto-optically gated detection

This contribution introduces a new type of setup for fast sample analysis using laser-induced breakdown spectroscopy (LIBS). The novel design combines a high repetition rate laser (up to 50 kHz) as excitation source and an acousto-optical modulator (AOM) as a fast switch for temporally gating the detection of the emitted light. The plasma radiation is led through the active medium of the AOM where it is diffracted on the transient ultrasonic Bragg grid. The diffracted radiation is detected by a compact Czerny-Turner spectrometer equipped with a CCD line detector. Utilizing the new combination of high repetition rate lasers and AOM gated detection, rapid measurements with total integration times of only 10 ms resulted in a limit of detection (LOD) of 0.13 wt.% for magnesium in aluminum alloys. This short integration time corresponds to 100 analyses/s. Temporal gating of LIP radiation results in improved LODs and consecutively higher sensitivity of the LIBS setup. Therefore, an AOM could be beneficially utilized to temporally detect plasmas induced by high repetition rate lasers. The AOM in combination with miniaturized Czerny-Turner spectrometers equipped with CCD line detectors and small footprint diode pumped solid state lasers results in temporally gateable compact LIBS setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single molecule transistor based nanopore for the detection of nicotine

A nanopore based detection methodology was proposed and investigated for the detection of Nicotine. This technique uses a Single Molecular Transistor working as a nanopore operational in the Coulomb Blockade regime. When the Nicotine molecule is pulled through the nanopore area surrounded by the Source(S), Drain (D), and Gate electrodes, the charge stability diagram can detect the presence of the molecule and is unique for a specific molecular structure. Due to the weak coupling between the different electrodes which is set by the nanopore size, the molecular energy states stay almost unaffected by the electrostatic environment that can be realised from the charge stability diagram. Identification of different orientation and position of the Nicotine molecule within the nanopore area can be made from specific regions of overlap between different charge states on the stability diagram that could be used as an electronic fingerprint for detection. This method could be advantageous and useful to detect the presence of Nicotine in smoke which is usually performed using chemical chromatography techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detecting brain tumor in computed tomography images using Markov random fields and fuzzy C-means clustering techniques

Brain tumors, are an abnormal growth of tissues in the brain. They may arise in people of any age. They must be detected early, diagnosed accurately, monitored carefully, and treated effectively in order to optimize patient outcomes regarding both survival and quality of life. Manual segmentation of brain tumors from CT scan images is a challenging and time consuming task. Size and location accurate detection of brain tumor plays a vital role in the successful diagnosis and treatment of tumors. Brain tumor detection is considered a challenging mission in medical image processing. The aim of this paper is to introduce a scheme for tumor detection in CT scan images using two different techniques Hidden Markov Random Fields (HMRF) and Fuzzy C-means (FCM). The proposed method has been developed in this research in order to construct hybrid method between (HMRF) and threshold. These methods have been applied on 4 different patient data sets. The result of comparison among these methods shows that the proposed method gives good results for brain tissue detection, and is more robust and effective compared with (FCM) techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗