Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Design technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

The GlueX central drift chamber: Design and performance

Tests and studies concerning the design and performance of the GlueX Central Drift Chamber (CDC) are presented. A full-scale prototype was built to test and steer the mechanical and electronic design. Small scale prototypes were constructed to test for sagging and to do timing and resolution studies of the detector. These studies were used to choose the gas mixture and to program a Monte Carlo simulation that can predict the detector response in an external magnetic field. Particle identification and charge division possibilities were also investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of an optimized hexapole magnet for a 14.5 GHz electron cyclotron resonance ion source

A hexapole magnet for a 14.5 GHz electron cyclotron resonance (ECR) ion source, where the maximum radial field on the wall of the plasma chamber is higher than 1.1 T, has been designed and fabricated. The size of the outer diameter and the number of the sector of the hexapole are optimized for a 14.5 GHz ECR ion source with the help of a three-dimensional field calculation code. Moreover, to make a strong and long-life magnet against the demagnetic field on the hexapole multilayered structure in radial and axial directions is considered in the design. The distributions of the demagnetic fields are estimated by the calculation of the radial field in a hexapole magnet and the axial field from the solenoid coils. Proper grades of magnetic materials depending on the strength of the demagnetic field are applied for the different layers. The magnetic fields of the measured and calculated ones have been compared.

43 PARTICLE ACCELERATORS↗

Bragg x-ray survey spectrometer for ITER

Several potential impurity ions in the ITER plasmas will lead to loss of confined energy through line and continuum emission. For real time monitoring of impurities, a seven channel Bragg x-ray spectrometer (XRCS survey) is considered. This paper presents design and analysis of the spectrometer, including x-ray tracing by the Shadow-XOP code, sensitivity calculations for reference H-mode plasma and neutronics assessment. The XRCS survey performance analysis shows that the ITER measurement requirements of impurity monitoring in 10 ms integration time at the minimum levels for low-Z to high-Z impurity ions can largely be met.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal expansion recovery microscopy: Practical design considerations

A detailed study of relevant parameters for the design and operation of a photothermal microscope technique recently introduced is presented. The technique, named thermal expansion recovery microscopy (ThERM) relies in the measurement of the defocusing introduced by a surface that expands and recovers upon the heating from a modulated source. A new two lens design is presented that can be easily adapted to commercial infinite conjugate microscopes and the sensitivity to misalignment is analyzed. The way to determine the beam size by means of a focus scan and the use of that same scan to verify if a thermoreflectance signal is overlapping with the desired ThERM mechanism are discussed. Finally, a method to cancel the thermoreflectance signal by an adequate choice of a nanometric coating is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The motional Stark effect diagnostic on NSTX

This work describes the implementation and recent results from the motional Stark effect (MSE) collisionally induced fluorescence diagnostic on NSTX. Due to the low magnetic field on NSTX the MSE diagnostic requires a new approach for the viewing optics and spectral filter. This has been accomplished with a novel optical design that reduces the geometric Doppler broadening, and a high throughput, high resolution spectral filter to optimize signal-to-noise ratio. With these improvements the polarization fraction is {approx}30%-40% and, combined with the large throughput, a time resolution of {approx}5 ms. The MSE diagnostic presently has 16 sight lines operating, providing measurements of the magnetic field line pitch from the plasma center to near the outboard edge of the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Test Reactor In-Canal Ultrasonic Scanner: Experiment Design and Initial Results on Irradiated Plates

An irradiation test device has been developed to support testing of prototypic scale plate type fuels in the Advanced Test Reactor. The experiment hardware and operating conditions were optimized to provide the irradiation conditions necessary to conduct performance and qualification tests on research reactor type fuels for the RERTR program. The device was designed to allow disassembly and reassembly in the ATR spent fuel canal so that interim inspections could be performed on the fuel plates. An ultrasonic scanner was developed to perform dimensional and transmission inspections during these interim investigations. Example results from the AFIP-2 experiment are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NESSUS (Numerical Evaluation of Stochastic Structures Under Stress)/EXPERT: Bridging the gap between artificial intelligence and FORTRAN

The development of a probabilistic structural analysis methodology (PSAM) is described. In the near-term, the methodology will be applied to designing critical components of the next generation space shuttle main engine. In the long-term, PSAM will be applied very broadly, providing designers with a new technology for more effective design of structures whose character and performance are significantly affected by random variables. The software under development to implement the ideas developed in PSAM resembles, in many ways, conventional deterministic structural analysis code. However, several additional capabilities regarding the probabilistic analysis makes the input data requirements and the resulting output even more complex. As a result, an intelligent front- and back-end to the code is being developed to assist the design engineer in providing the input data in a correct and appropriate manner. The type of knowledge that this entails is, in general, heuristically-based, allowing the fairly well-understood technology of production rules to apply with little difficulty. However, the PSAM code, called NESSUS, is written in FORTRAN-77 and runs on a DEC VAX. Thus, the associated expert system, called NESSUS/EXPERT, must run on a DEC VAX as well, and integrate effectively and efficiently with the existing FORTRAN code. This paper discusses the process undergone to select a suitable tool, identify an appropriate division between the functions that should be performed in FORTRAN and those that should be performed by production rules, and how integration of the conventional and AI technologies was achieved.

Fink, Pamela K.↗

Combining low-energy electron microscopy and scanning probe microscopy techniques for surface science: Development of a novel sample-holder

We introduce an experimental facility dedicated to surface science that combines Low-Energy Electron Microscopy/Photo-Electron Emission Microscopy (LEEM/PEEM) and variable-temperature Scanning Probe Microscopy techniques. A technical challenge has been to design a sample-holder that allows to exploit the complementary specifications of both microscopes and to preserve their optimal functionality. Experimental demonstration is reported by characterizing under ultrahigh vacuum with both techniques: Au(111) surface reconstruction and a two-layer thick graphene on 6H-SiC(0001). A set of macros to analyze LEEM/PEEM data extends the capabilities of the setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of 0.38 THz backward-wave oscillator based on slotted sine waveguide and pencil electron beam

A novel backward wave oscillator (BWO) is presented by utilizing a slotted sine waveguide with a pencil electron beam to produce the high power terahertz wave. The high frequency characteristics including dispersion properties, interaction impedances, and transmission characteristics of the slotted sine waveguide are analyzed in detail. The high frequency system including the output coupler, slow wave structure (SWS), and reflector are designed properly. A 3-D particle-in-cell mode is applied to predict the device performance of the BWO based on the novel SWS. The investigation results demonstrate that this device can generate over 8.05 W output power in the frequency range of 363.4–383.8 GHz by using a 30 mA pencil electron beam and adjusting the beam voltage from 20 kV to 32 kV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reducing Turbulent Transport in Toroidal Configurations via Shaping

Recent progress in reducing turbulent transport in stellarators and tokamaks by 3D shaping using a stellarator optimization code in conjunction with a gyrokinetic code is presented. The original applications of the method focussed on ion temperature gradient transport in a quasi-axisymmetric stellarator design. Here, an examination of both other turbulence channels and other starting configurations is initiated. It is found that the designs evolved for transport from ion temperature gradient turbulence also display reduced transport from other transport channels whose modes are also stabilized by improved curvature, such as electron temperature gradient and ballooning modes. The optimizer is also applied to evolving from a tokamak, finding appreciable turbulence reduction for these devices as well. From these studies, improved understanding is obtained of why the deformations found by the optimizer are beneficial, and these deformations are related to earlier theoretical work in both stellarators and tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and Test of a Large Aperture $Nb_3Sn$ Cos-Theta Dipole Coil with Stress Management

An innovative stress-management (SM) concept for cos-theta (CT) coils (SMCT coil concept) has been proposed at Fermilab. A large-aperture two-layer Nb3Sn SMCT dipole coil was designed and manufactured to validate and test the SM concept including coil design, fabrication technology, and performance. The first large-aperture SMCT coil (SMCT1) was fabricated and assembled with a small-aperture Nb3Sn coil inside a dipole mirror magnet. SMCT1 coil tests in a dipole mirror structure was performed in two configurations - SMCTM1a with only powered two-layer SMCT1 coil and SMCTM1b with the SMCT coil connected in series with an inner two-layer dipole coil. The test goals are to prove the SMCT coil concept in two-layer and four-layer mirror configurations; demonstrate that the magnet can reach the targeted quench current at the established preload; study magnet training, training memory after thermal cycle, ramp rate and temperature dependences of the magnet quench current; and test the SMCT1 coil quench protection parameters. This paper summarizes the SMCT1 coil design and parameters, the coil main fabrication steps, its assembly in the dipole mirror structure. The results of the SMCTM1a/b mirror test are presented and discussed.

43 PARTICLE ACCELERATORS↗

Low Enriched Uranium Core Design for the Massachusetts Institute of Technology Reactor (MITR) with Un-finned 12 mil-thick Clad UMo Monolithic Fuel

This report contains the results of reactor fuel element design for conversion of the Massachusetts Institute of Technology Reactor (MITR) from the use of highly enriched uranium (HEU) fuel to the use of low enriched uranium (LEU) fuel. The analyses were performed by staff members of the Global Threat Reduction Initiative (GTRI) Reactor Conversion Program at the Argonne National Laboratory (ANL) and the Massachusetts Institute of Technology Nuclear Reactor Laboratory. The core conversion to LEU is being performed with financial support of the U.S. government.

Bergeron, A.↗

An optically accessible pyrolysis microreactor

We report an optically accessible pyrolysis micro-reactor suitable for in situ laser spectroscopic measurements. A radiative heating design allows for completely unobstructed views of the micro-reactor along two axes. The maximum temperature demonstrated here is only 1300 K (as opposed to 1700 K for the usual SiC micro-reactor) because of the melting point of fused silica, but alternative transparent materials will allow for higher temperatures. Laser induced fluorescence measurements on nitric oxide are presented as a proof of principle for spectroscopic characterization of pyrolysis conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rocket Engine Turbine Blade Surface Pressure Distributions Experiment and Computations

Understanding the unsteady aspects of turbine rotor flow fields is critical to successful future turbine designs. A technology program was conducted at NASA's Marshall Space Flight Center to increase the understanding of unsteady environments for rocket engine turbines. The experimental program involved instrumenting turbine rotor blades with miniature surface mounted high frequency response pressure transducers. The turbine model was then tested to measure the unsteady pressures on the rotor blades. The data obtained from the experimental program is unique in two respects. First, much more unsteady data was obtained (several minutes per set point) than has been possible in the past. Also, an extensive steady performance database existed for the turbine model. This allowed an evaluation of the effect of the on-blade instrumentation on the turbine's performance. A three-dimensional unsteady Navier-Stokes analysis was also used to blindly predict the unsteady flow field in the turbine at the design operating conditions and at +15 degrees relative incidence to the first-stage rotor. The predicted time-averaged and unsteady pressure distributions show good agreement with the experimental data. This unique data set, the lessons learned for acquiring this type of data, and the improvements made to the data analysis and prediction tools are contributing significantly to current Space Launch Initiative turbine airflow test and blade surface pressure prediction efforts.

Hudson, Susan T.↗

Design and assessment of a 6 ps-resolution time-to-digital converter with 5 MGy gamma-dose tolerance for nuclear instrumentation

Time-to-Digital Converters (TDCs) are key building blocks in time-based mixed-signal systems, used for the digitization of analog signals in time domain. A short survey on state-of-the-art TDCs is given. In order to realize a TDC with picosecond time resolution as well as multi MGy gamma-dose radiation tolerance, a novel multi-stage noise-shaping (MASH) delta-sigma ({Delta}{Sigma}) TDC structure is proposed. The converter, implemented in 0.13 {mu}m, achieves a time resolution of 5.6 ps and an ENOB of 11 bits, when the over sampling ratio (OSR) is 250. The TDC core consumes only 1.7 mW, and occupies an area of 0.11 mm{sup 2}. Owing to the usage of circuit level radiation hardened-by-design techniques, such as passive RC oscillators and constant-g{sub m} biasing, the TDC exhibits enhanced radiation tolerance. At a low dose rate of 1.2 kGy/h, the frequency of the counting clock in the TDC remains constant up to at least 160 kGy. Even after a total dose of 3.4 MGy at a high dose rate of 30 kGy/h, the TDC still achieves a time resolution of 10.5 ps with an OSR of 250. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY15 Status of Immersion Phased Array Ultrasonic Probe Development and Performance Demonstration Results for Under Sodium Viewing

This Technical Letter Report (TLR) describes work conducted at the Pacific Northwest National Laboratory (PNNL) during FY 2015 on the under-sodium viewing (USV) PNNL project 58745, Work Package AT-15PN230102. This TLR satisfies PNNL’s M3AT-15PN2301027 milestone, and is focused on summarizing the design, development, and evaluation of a two-dimensional matrix phased-array probe referred to as serial number 3 (SN3). In addition, this TLR also provides the results from a performance demonstration of in-sodium target detection trials at 260°C using a one-dimensional 22-element linear array developed in FY14 and referred to as serial number 2 (SN2).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Propulsion Study for Small Transport Aircraft Technology (STAT)

Propulsion requirements were determined for 0.5 and 0.7 Mach aircraft. Sensitivity studies were conducted on both these aircraft to determine parametrically the influence of propulsion characteristics on aircraft size and direct operating cost (DOC). Candidate technology elements and design features were identified and parametric studies conducted to select the STAT advanced engine cycle. Trade off studies were conducted to determine those advanced technologies and design features that would offer a reduction in DOC for operation of the STAT engines. These features were incorporated in the two STAT engines. A benefit assessment was conducted comparing the STAT engines to current technology engines of the same power and to 1985 derivatives of the current technology engines. Research and development programs were recommended as part of an overall technology development plan to ensure that full commercial development of the STAT engines could be initiated in 1988.

Gill, J. C.↗