Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Confocal Raman imaging of skin sections containing hair follicles using classical least squares regression and multivariate curve resolution – alternating least squares

Confocal Raman microscopy (CRM) is applied ex vivo for imaging of the spatial distribution of different skin components in skin sections containing hair follicles. For multivariate data analysis, different methods are used in order to spectrally decompose the reference spectra of the skin components (dermis, viable epidermis, stratum corneum and hair). Classical least squares regression (CLS) and multivariate curve resolution–alternating least squares (MCR-ALS) are chosen as suitable methods. In comparison to other optical methods, the advantage of CRM is molecular specificity and dispensability of labelling dyes, which is e.g. necessary in fluorescence microscopy. Therefore, a useful future application of CRM in combination with multivariate data analysis lies in the analysis of penetration routes of topically applied substances, such as cosmetic formulations or drugs into the skin, which is particularly interesting in and around hair follicles. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The persistence of large scale structures. Part I. Primordial non-Gaussianity

Abstract We develop an analysis pipeline for characterizing the topology of large scale structure and extracting cosmological constraints based on persistent homology . Persistent homology is a technique from topological data analysis that quantifies the multiscale topology of a data set, in our context unifying the contributions of clusters, filament loops, and cosmic voids to cosmological constraints. We describe how this method captures the imprint of primordial local non-Gaussianity on the late-time distribution of dark matter halos, using a set of N-body simulations as a proxy for real data analysis. For our best single statistic, running the pipeline on several cubic volumes of size 40 (Gpc/h) 3 , we detect f NL loc =10 at 97.5% confidence on ~ 85% of the volumes. Additionally wetest our ability to resolve degeneracies betweenthe topological signature of f NL loc and variation of σ 8 and argue that correctly identifying nonzero f NL loc in this case is possible via an optimal template method. Our method relies on information living at $\mathcal{O}$(10) Mpc/h, a complementary scale with respect to commonly used methods such as the scale-dependent bias in the halo/galaxy power spectrum. Therefore, while still requiring a large volume, our method does not require sampling long-wavelength modes to constrain primordial non-Gaussianity. Moreover, our statistics are interpretable: we are able to reproduce previous results in certain limits and we make new predictions for unexplored observables, such as filament loops formed by dark matter halos in a simulation box.

Astronomy & Astrophysics↗

Improving Subsurface Stress Characterization for Carbon Dioxide Storage Projects by Incorporating Machine Learning Techniques

The overall objective of this project is to develop a framework for reliable characterization and prediction of the state of stress in the overburden and underburden (including the basement) in CO 2 storage reservoirs using machine learning and integrated geomechanics and geophysical methods. Specifically, we propose to develop workflow encompassing of technologies and/or methods to predict stress and pressure changes due to CO 2 injection in an active tertiary recovery site and their impacts on subtle fault activation, fractures and occurrence of microseismic events and compare responses to field observations. In this project, we anticipate using dataset from the Farnsworth field Unit (FWU) which is operated by Purdure Petroleum. A novel elastic-waveform VSP inversion technique will be used to estimate high-resolution spatial and temporal changes of elastic moduli in CO 2 storage reservoirs, which will be combined with velocity-stress relationship derived from laboratory tests to obtain subsurface pressure and stress. Clustered microseismic data will be jointly inverted for improved focal mechanisms. Least-squares reverse-time migration of microseismic waveform data will be performed to directly image fracture/fault zones. Additionally, a deep neural network machine learning technique with convolutional and recurrent layers will be used for learning the spectro-temporal structures in microseismic waveforms. The results of this geotechnical data analysis will be integrated to develop a high-resolution 3D mechanical earth model extending from the overburden sealing formations to the underburden including the basement. Mechanical properties will be derived through integration of mechanical logs, tests, available results from chemo-mechanical laboratory tests, and elastic inversion of seismic data using a combination of Bayesian and stochastic methods as well as machine learning technique. Failure features (faults/fractures) will be represented and/or modeled based on seismic and core data analysis. A transient hydrodynamic-geomechanical model will be developed through coupling with the calibrated FWU reservoir simulation model. The full physics coupled model will be used to train a reduced order proxy model using machine learning algorithm for estimating stress which will then be used with appropriate constitutive relationships and forward seismological models to simulate pressure changes and induced microseismicity. An advanced optimization framework will be developed to perform a history match to minimize error between field observations and simulated. The history matched proxy model will be verified against the full-physics equivalent. The field observations that will be used in the coupled model calibration process include pressure/stress inverted from VSP, moment magnitude from microseismic analysis, real time downhole pressure measurements, production and injection data. Parameter sensitivity and uncertainty analysis will be performed to characterize the impact of model parameter uncertainty on stress estimates. The proposed project will have significant impact on future field implementation of the proposed technology. Because the project field site is an ongoing CO 2 EOR development, the value of the new technology will be demonstrated in an operational context and evaluated as a viable risk mitigation strategy. Cost/benefit will be evaluated together with the various commercial incentives for CO 2 sequestration available to oil and gas operators. The extensive available dataset and ongoing data acquisition under the SWP Phase III work plan provides flexibility for investigation of multiple approaches and reduces technical risk.

58 GEOSCIENCES↗

Passive neutron coincidence counting with plastic scintillators for the characterization of radioactive waste drums

The quantification of radioactive material is essential in the fields of safeguards, criticality control of nuclear processes, dismantling of nuclear facilities and components, or radioactive waste characterization. The Nuclear Measurement Laboratory (LMN) of CEA is involved in the development of time-correlated neutron detection techniques using plastic scintillators. Usually, 3He proportional counters are used for passive neutron coincidence counting owing to their high thermal neutron capture efficiency and gamma insensitivity. However, the global {sup 3}He shortage in the past few years has made these detectors extremely expensive. In addition, contrary to {sup 3}He counters for which a few tens of microseconds are needed to thermalize fast neutrons, in view to maximize the {sup 3}He(n,p){sup 3}H capture cross section, plastic scintillators are based on elastic scattering and therefore the light signal is formed within a few nanoseconds, correlated pulses being detected within a few dozen- or hundred nanoseconds. This time span reflects fission particles time of flight, which allows reducing accordingly the duration of the coincidence gate and thus the rate of random coincidences, which may totally blind fission coincidences when using {sup 3}He counters in case of a high (α,n) reaction rate. However, plastic scintillators are very sensitive to gamma rays, requiring the use of a thick metallic shield to reduce the corresponding background. Cross talk between detectors is also a major issue, which consists on the detection of one particle by several detectors due to elastic or inelastic scattering, leading to true but undesired coincidences. Data analysis algorithms are tested to minimize cross-talk in simultaneously activated detectors. The distinction between useful fission coincidences and the correlated background due to cross-talk, (α,n) and induced (n,2n) or (n,n'γ) reactions, is achieved by measuring 3-fold coincidences. The performances of a passive neutron coincidence counting system for radioactive waste drums using plastic scintillators have been studied using the Monte Carlo radiation transport code MCNPX-PoliMi v2.0 coupled to data processing algorithms developed with ROOT data analysis software. In addition to the correlated background, accidental coincidences are taken into account in the simulation by randomly merging pulses from different calculations with fission and (α,n) sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data acquisition and processing system of the electron cyclotron emission imaging system of the KSTAR tokamak

A new innovative electron cyclotron emission imaging (ECEI) diagnostic system for the Korean Superconducting Tokamak Advanced Research (KSTAR) produces a large amount of data. The design of the data acquisition and processing system of the ECEI diagnostic system should consider covering the large data production and flow. The system design is based on the layered structure scalable to the future extension to accommodate increasing data demands. Software architecture that allows a web-based monitoring of the operation status, remote experiment, and data analysis is discussed. The operating software will help machine operators and users validate the acquired data promptly, prepare next discharge, and enhance the experiment performance and data analysis in a distributed environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-D-BRF-01: Pediatric Treatment Planning II: The PENTEC Report On Normal Tissue Complications

With advances in multimodality therapy, childhood cancer cure rates approach 80%. However, both radiotherapy and chemotherapy may cause debilitating or even fatal ‘late effects’ that are critical to understand, mitigate, or prevent. QUANTEC identified the uncertainties relating to side-effects of adult treatments, but this is more complicated for children in whom a mosaic of tissues develops at different rates and temporal sequences. Childhood cancer survivors have long life expectancy and may develop treatmentinduced secondary cancers and severe organ/tissue injury decades after treatment. Collaborative long-term observational studies and clinical research programs for survivors of pediatric and adolescent cancer provide some dose-response data for follow-up periods exceeding 40 years. Data analysis is challenging due to the influence of both therapeutic and developmental variables. PENTEC is a group of radiation oncologists, pediatric oncologists, subsepcialty physicians, medical physicists, biomathematic modelers/statisticians, and epidemiologists charged with conducting a critical synthesis of existing literature aiming to: critically analyze radiation dose-volume effects on normal tissue tolerances as a function of age/development in pediatric cancer patients in order to inform treatment planning and improve outcomes for survivors; describe relevant physics issues specific to pediatric radiotherapy; propose dose-volumeoutcome reporting standards to improve the knowledge base to inform future treatment guidelines. PENTEC has developed guidelines for systematic literature reviews, data extraction tolls and data analysis. This education session will discuss:1. Special considerations for normal tissue radiation response of children/adolescents, e.g. the interplay between development and radiotherapy effects.2. Epidemiology of organ/tissue injuries and secondary cancers.3. Exploration of dose-response differences between children and adults4. Methodology for literature review, data mining of outcomes databases, and NTCP or longitudinal modeling of doseresponse. 5. PENTEC goals and timetable. Learning Objectives: Understand important differences between normal tissue effects of radiation therapy in pediatric and adult patients. Be able to identify situations where there is ‘interplay’ between organ development and radiation-induced complications. Identify methods to systematically extract quantitative dose-volumeresponse relationships from existing outcomes databases. Provide guidance for the medical physicist to properly understand, implement, guide and control contemporary technology and applications in pediatric radiation oncology.

60 APPLIED LIFE SCIENCES↗

Impact Analysis of Data Integrity Attacks on FACTS-based Wide-Area Voltage Control System

Energy management system (EMS) consists of several wide-area control applications that serve as a backbone for security, stability, and reliability of the power system. Wide-area voltage control system (WAVCS), one of the critical wide-area applications, operates in coordination with local Flexible AC Transmission System (FACTS) devices to provide voltage security and optimal management of active and reactive power resources. Since the WAVCS relies on wide-area communication and data sharing devices, possible cybersecurity vulnerabilities have to be addressed to ensure the closed-loop operation of WAVCS. In this paper, we present a methodology for performing an impact analysis of cyber-attacks in WAVCS cybersecurity. In particular, different types of data integrity attacks, such as malicious tripping, fault replay, and signal altering attacks, are considered, and detailed impact analysis is conducted in a testbed environment using the Kundur's four machine two-area system. For performing an impact analysis, the transient voltage stability of the sensitive bus voltage is studied, followed by the quantitative assessment and severity ranking using the voltage profile index. Our experimental evaluation reveals that the data integrity attacks on control signals exhibit a higher attack severity than on the measurement signals. Further, the severity of these attacks varies with nature (static or dynamic), location, and types of attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing a Thomson scattering diagnostic for fast dynamics and high background

The Madison Symmetric Torus (MST) presents challenging conditions for Thomson scattering (TS) measurements. The MST plasmas are reversed-field pinches (RFPs) with electron density n{sub e}<3x10{sup 13} cm{sup -3}, typically 1x10{sup 13} cm{sup -3}. The TS system was designed to measure from 10 eV to 2 keV; however, six polychromators were upgraded from four to eight spectral channels to resolve to 10 keV. There is no diverter or vertical field, so wall interaction results in high background light both from ion and neutral bremsstrahlungs and from line radiation. Also during standard plasmas, the RFP exhibits regular reconnection sawteeth events during which the plasma current, density, and temperature profiles are flattened. These events are of interest both due to the reconnection physics and to their contribution to the MST equilibrium and confinement. These events occur over 100 {mu}S and exhibit large changes in background light and fast changes in temperature. During improved confinement plasmas, there are no sawteeth; the background is low but the temperature can be over an order of magnitude higher. Data analysis of the system has been developed to accommodate both the large dynamic range of the temperature, the fast dynamics, and the fast changing, high amplitude background. Special attention has been paid to the sources of error, in particular, the contribution of the background. A response-function method reduces the measured uncertainty by a factor of 2. Numerical techniques have been developed which are extremely robust. Two methods are used, a conventional {chi}{sup 2} minimization using a Levenberg-Marquardt algorithm coupled with Monte Carlo modeling for the error bar and a Bayesian statistics method. The Bayesian method computes the probability distribution for the measured photons and electron temperature and this information can be used to ensemble data and will allow future integrated data analysis efforts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of Platooning Trucks to Better Understand Dynamic Air Flow

Track testing has shown significant fuel-savings promise for truck platooning strategies but also raised unexpected questions about close following and long-distance following scenarios that could significantly impact savings realized in real-world conditions. The 2017 track test collaboration among NREL, Lawrence Berkeley National Laboratory, NRC Canada, Transport Canada, and others included onboard instrumentation to help the team gain a deeper understanding of the dynamic interaction between multiple vehicles. NREL's approach includes detailed data analysis for additional onboard sensors and J1939 CAN bus data from 2017 track test to investigate following truck air flow and turbulence changes to explain reduced savings at close following distances for the last vehicle in a platoon, define engine-cooling impacts of platooning position in different formations due to reduction of ram air through front grill and generate an understanding of a true in-use "baseline" with other vehicles on the highway. Initial data analysis indicates many of the data trends in wind angle, wind speed, and temperatures show a change in pattern for the closer following distances where fuel savings decrease for the following vehicles was also documented. This is encouraging in that the planned further analysis may yield the desired insights into the cause of the reduced savings. Once analyzed, light-duty vehicle and dynamic scenarios will help us refine the sensitivity of findings from the standard platooning scenarios.

30 DIRECT ENERGY CONVERSION↗

A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process

Recent progress in sensing techniques and data analytics tools have significantly accelerated the development of Wire Arc Additive Manufacturing (WAAM) systems. This data centric approach emphasizes leveraging available data throughout the production process to optimize performance. Integration of extensive data analysis provides the opportunity to improve precision, reduce waste, and enhance the quality of produced parts. This method relies on AI/ML models and optimization techniques, which are developed using the data collected from various sources, including in-situ sensors, ex-situ imaging, and manufacturing process parameters. The quality and diversity of this data, along with the alignment between different data streams (achieved through spatiotemporal registration) are critical for the successful development of AI/ML and optimization models. In this work, we present a spatiotemporally registered dataset generated during the WAAM process of deposition of a rectangular block. The dataset includes the comprehensive description of deposition process, process parameters, in-situ collected welding characteristics, acoustic data, and X-Ray Computed Tomography analysis data for the build. Dataset A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process has arisen under UT-Battelle, LLC’s Prime Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy (DOE) to manage and operate the Oak Ridge National Laboratory. UT-Battelle, LLC will not assert any rights under United States law or under the Prime Contract it has in the dataset against any user of the dataset, including any copyrights or patent rights. UT-Battelle, LLC requests that attribution to the dataset is provided as academically appropriate.

42 ENGINEERING↗

National Cancer Data Base Analysis of Radiation Therapy Consolidation Modality for Cervical Cancer: The Impact of New Technological Advancements

Purpose: To utilize the National Cancer Data Base to evaluate trends in brachytherapy and alternative radiation therapy utilization in the treatment of cervical cancer, to identify associations with outcomes between the various radiation therapy modalities. Methods and Materials: Patients with International Federation of Gynecology and Obstetrics stage IIB-IVA cervical cancer in the National Cancer Data Base who received treatment from January 2004 to December 2011 were analyzed. Overall survival was estimated by the Kaplan-Meier method. Univariate and multivariable analyses were performed to identify factors associated with type of boost radiation modality used and its impact on survival. Results: A total of 7654 patients had information regarding boost modality. A predominant proportion of patients were Caucasian (76.2%), had stage IIIB (48.9%) disease with squamous (82.0%) histology, were treated at academic/research centers (47.7%) in the South (34.8%), and lived 0 to 5 miles (27.9%) from the treating facility. A majority received brachytherapy (90.3%). From 2004 to 2011, brachytherapy use decreased from 96.7% to 86.1%, whereas intensity modulated radiation therapy (IMRT) and stereotactic body radiation therapy (SBRT) use increased from 3.3% to 13.9% in the same period (P<.01). Factors associated with decreased brachytherapy utilization included older age, stage IVA disease, smaller tumor size, later year of diagnosis, lower-volume treatment centers, and facility type. After controlling for significant factors from survival analyses, IMRT or SBRT boost resulted in inferior overall survival (hazard ratio, 1.86; 95% confidence interval, 1.35-2.55; P<.01) as compared with brachytherapy. In fact, the survival detriment associated with IMRT or SBRT boost was stronger than that associated with excluding chemotherapy (hazard ratio, 1.61′ 95% confidence interval, 1.27-2.04′ P<.01). Conclusions: Consolidation brachytherapy is a critical treatment component for locally advanced cervical cancer; however, there has been declining utilization of brachytherapy. Increased use of IMRT and SBRT boost coupled with increased mortality risk should raise concerns about utilizing these approaches over brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of maximum likelihood methods to laser Thomson scattering measurements of low density plasmas

Laser Thomson scattering (LTS) is an established plasma diagnostic technique that has seen recent application to low density plasmas. It is difficult to perform LTS measurements when the scattered signal is weak as a result of low electron number density, poor optical access to the plasma, or both. Photon counting methods are often implemented in order to perform measurements in these low signal conditions. However, photon counting measurements performed with photo-multiplier tubes are time consuming and multi-photon arrivals are incorrectly recorded. In order to overcome these shortcomings a new data analysis method based on maximum likelihood estimation was developed. The key feature of this new data processing method is the inclusion of non-arrival events in determining the scattered Thomson signal. Maximum likelihood estimation and its application to Thomson scattering at low signal levels is presented and application of the new processing method to LTS measurements performed in the plume of a 2-kW Hall-effect thruster is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

sitoolbox: A package for Bayesian estimation of the isotropy violation in the CMB sky

ABSTRACT The standard model of cosmology predicts a statistically isotropic (SI) cosmic microwave background (CMB) sky. However, the SI violation signals are always present in an observed sky-map. Different cosmological artefacts, measurement effects, and unavoidable effects during data analysis, etc. may lead to isotropy violation in an otherwise SI sky. Therefore, a proper data analysis technique should calculate all these SI violation signals, so that they can be matched with SI violation signals from the known sources, and then conclude if there is any intrinsic SI violation in the CMB sky. In one of our recent works, we presented a general Bayesian formalism for measuring the isotropy violation signals in the CMB sky in the presence of an idealized isotropic noise. In this paper, we have extended the mechanism and develop a software package, sitoolbox, for measuring SI violation in presence of anisotropic noise and masking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Secondary Ion Mass Spectral Imaging of Metals and Alloys

Secondary Ion Mass Spectrometry (SIMS) is an outstanding technique for Mass Spectral Imaging (MSI) due to its notable advantages, including high sensitivity, selectivity, and high dynamic range. As a result, SIMS has been employed across many domains of science. In this review, we provide an in-depth overview of the fundamental principles underlying SIMS, followed by an account of the recent development of SIMS instruments. The review encompasses various applications of specific SIMS instruments, notably static SIMS with time-of-flight SIMS (ToF-SIMS) as a widely used platform and dynamic SIMS with Nano SIMS and large geometry SIMS as successful instruments. We particularly focus on SIMS utility in microanalysis and imaging of metals and alloys as materials of interest. Additionally, we discuss the challenges in big SIMS data analysis and give examples of machine leaning (ML) and Artificial Intelligence (AI) for effective MSI data analysis. Finally, we recommend the outlook of SIMS development. It is anticipated that in situ and operando SIMS has the potential to significantly enhance the investigation of metals and alloys by enabling real-time examinations of material surfaces and interfaces during dynamic transformations.

36 MATERIALS SCIENCE↗

TH-AB-209-02: Gadolinium Measurements in Human Bone Using in Vivo K X-Ray Fluorescence (KXRF) Technique

Purpose: Improvement in an in vivo K x-ray fluorescence system, based on 109Cd source, for the detection of gadolinium (Gd) in bone has been investigated. Series of improvements to the method is described. Gd is of interest because of the extensive use of Gd-based contrast agents in MR imaging and the potential toxicity of Gd exposure. Methods: A set of seven bone equivalent phantoms with different amount of Gd concentrations (from 0–100 ppm) has been developed. Soft tissue equivalent plastic plates were used to simulate the soft tissue overlaying the tibia bone in an in vivo measurement. A new 5 GBq 109Cd source was used to improve the source activity in comparison to the previous study (0.17 GBq). An improved spectral fitting program was utilized for data analysis. Results: The previous published minimum detection limit (MDL) for Gd doped phantom measurements using KXRF system was 3.3 ppm. In this study the MDL for bare bone phantoms was found to be 0.8 ppm. Our previous study used only three layers of plastic (0.32, 0.64 and 0.96 mm) as soft tissue equivalent materials and obtained the MDL of 4–4.8 ppm. In this study the plastic plates with more realistic thicknesses to simulate the soft tissue covering tibia bone (nine thicknesses ranging from 0.61–6.13 mm) were used. The MDLs for phantoms were determined to be 1.8–3.5 ppm. Conclusion: With the improvements made to the technology (stronger source, improved data analysis algorithm, realistic soft tissue thicknesses), the MDL of the KXRF system to measure Gd in bare bone was improved by a factor of 4.1. The MDL is at the level of the bone Gd concentration reported in literature. Hence, the system is ready to be tested on human subjects to investigate the use of bone Gd as a biomarker for Gd toxicity.

60 APPLIED LIFE SCIENCES↗

Spherical harmonic modes of 5.5 post-Newtonian gravitational wave polarizations and associated factorized resummed waveforms for a particle in circular orbit around a Schwarzschild black hole

Recent breakthroughs in numerical relativity enable one to examine the validity of the post-Newtonian expansion in the late stages of inspiral. For the comparison between post-Newtonian (PN) expansion and numerical simulations, the waveforms in terms of the spin-weighted spherical harmonics are more useful than the plus and cross polarizations, which are used for data analysis of gravitational waves. Factorized resummed waveforms achieve better agreement with numerical results than the conventional Taylor expanded post-Newtonian waveforms. In this paper, we revisit the post-Newtonian expansion of gravitational waves for a test particle of mass {mu} in circular orbit of radius r{sub 0} around a Schwarzschild black hole of mass M and derive the spherical harmonic components associated with the gravitational wave polarizations up to order v{sup 11} beyond Newtonian. Using the more accurate h{sub lm}'s computed in this work, we provide the more complete set of associated {rho}{sub lm}'s and {delta}{sub lm}'s that form important bricks in the factorized resummation of waveforms with potential applications for the construction of further improved waveforms for prototypical compact binary sources in the future. We also provide ready-to-use expressions of the 5.5PN gravitational waves polarizations h{sub +} and h{sub x} in the test-particle limit for gravitational waves data analysis applications. Additionally, we provide closed analytical expressions for 2.5PN h{sub lm}, 2PN {rho}{sub lm}, and 3PN {delta}{sub lm}, for general multipolar orders l and m in the test-particle limit. Finally, we also examine the implications of the present analysis for compact binary sources in Laser Interferometer Space Antenna.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray power and yield measurements at the refurbished Z machine

Advancements have been made in the diagnostic techniques to measure accurately the total radiated x-ray yield and power from z-pinch implosion experiments at the Z machine with high accuracy. The Z machine is capable of outputting 2 MJ and 330 TW of x-ray yield and power, and accurately measuring these quantities is imperative. We will describe work over the past several years which include the development of new diagnostics, improvements to existing diagnostics, and implementation of automated data analysis routines. A set of experiments on the Z machine were conducted in which the load and machine configuration were held constant. During this shot series, it was observed that the total z-pinch x-ray emission power determined from the two common techniques for inferring the x-ray power, a Kimfol filtered x-ray diode diagnostic and the total power and energy diagnostic, gave 449 TW and 323 TW, respectively. Our analysis shows the latter to be the more accurate interpretation. More broadly, the comparison demonstrates the necessity to consider spectral response and field of view when inferring x-ray powers from z-pinch sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗