Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DISCHARGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Multi-Model Assessment of Global Hydropower and Cooling Water Discharge Potential Under Climate Change

Worldwide, 98% of total electricity is currently produced by thermoelectric power and hydropower. Climate change is expected to directly impact electricity supply, in terms of both water availability for hydropower generation and cooling water usage for thermoelectric power. Improved understanding of how climate change may impact the availability and temperature of water resources is therefore of major importance. Here we use a multi-model ensemble to show the potential impacts of climate change on global hydropower and cooling water discharge potential. For the first time, combined projections of streamflow and water temperature were produced with three global hydrological models (GHMs) to account for uncertainties in the structure and parametrization of these GHMs in both water availability and water temperature. The GHMs were forced with bias-corrected output of five general circulation models (GCMs) for both the lowest and highest representative concentration pathways (RCP2.6 and RCP8.5). The ensemble projections of streamflow and water temperature were then used to quantify impacts on gross hydropower potential and cooling water discharge capacity of rivers worldwide. We show that global gross hydropower potential is expected to increase between +2.4% (GCM-GHM ensemble mean for RCP 2.6) and +6.3% (RCP 8.5) for the 2080s compared to 1971-2000. The strongest increases in hydropower potential are expected for Central Africa, India, central Asia and the northern high-latitudes, with 18-33% of the world population living in these areas by the 2080s. Global mean cooling water discharge capacity is projected to decrease by 4.5-15% (2080s). The largest reductions are found for the United States, Europe, eastern Asia, and southern parts of South America, Africa and Australia, where strong water temperature increases are projected combined with reductions in mean annual streamflow. These regions are expected to affect 11-14% (for RCP2.6 and the shared socioeconomic pathway (SSP)1, SSP2, SSP4) and 41-51% (RCP8.5-SSP3, SSP5) of the world population by the 2080s.

global hydrological models↗

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge and Neutralizer Cathodes

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for both discharge and neutralizer cathodes. Discharge keeper erosion was found to be significantly reduced from what was observed in the NEXT 2 kh wear test and NSTAR Extended Life Test, providing adequate protection of vital cathode components throughout the test with ample lifetime remaining. The area of the discharge cathode orifice plate that was exposed by the keeper orifice exhibited net erosion, leading to cathode plate material building up in the cathode-keeper gap and causing a thermally-induced electrical short observed during the test. Significant erosion of the neutralizer cathode orifice was also found and is believed to be the root cause of an observed loss in flow margin. Deposition within the neutralizer keeper orifice as well as on the downstream surface was thicker than expected, potentially resulting in a facility-induced impact on the measured flow margin from plume mode. Neutralizer keeper wall erosion on the beam side was found to be significantly lower compared to the NEXT 2 kh wear test, likely due to the reduction in beam extraction diameter of the ion optics that resulted in decreased ion impingement. Results from the post-test inspection have led to some minor thruster design improvements.

Electric Propulsion↗

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for the discharge chamber as well as other miscellaneous components such as the high-voltage propellant isolators and electrical cabling. Comparison of magnetic field measurements taken during pretest and post-test inspections indicate that the field strength did not degrade, consistent with performance data obtained during the test. Inspection of discharge chamber mesh samples show a deposition coating primarily composed of grid material that is approximately 15 micrometers in thickness. This thickness is well within the retention capability of the mesh and is therefore not expected to present any issues. Approximately 3.1 grams of deposition flakes were found at the bottom of the discharge chamber, composed primarily of grid material and carbon. Calculated size histograms of these flakes indicate that 99% have a maximum dimension of 200 micrometers or smaller, which is significantly less than the ion optics grid gap. Larger flakes that are capable of causing a grid-to-grid short will be analyzed to determine if their formation will occur in flight or is a facility effect. The high-voltage propellant isolators as well as numerous other electrical insulators were inspected and no evidence of arcing or any other issues were found.

Electric Propulsion↗

Electrostatic Discharge Testing of Carbon Composite Solar Array Panels for the Europa Mission to Jupiter

Carbon composite solar array panel coupons similar to those considered for use on the planned NASA Europa Mission were exposed to energetic electrons to observe the size and rate of electrostatic discharge production. The discharge size and rate were found to be primarily dependent on the quantity of dielectric binder pooled on the surface of the sample. Cooling the samples to cryogenic temperatures increased the size of discharges but an end of mission radiation dose had only minimal effects. Samples were composed of M55J carbon composite impregnated with an RS3 binder. Additional samples tested included a co-cured Kapton surface.

Green, Nelson W.↗

Probing Sensitivity of Discharge Characteristics to Model Selection using Uncertainty Quantification in an aprotic Li-Oxygen Battery

Currently, there are several models in the literature, such as kinetic models, microstructural models, and mass transport models that describe a Li-air battery's discharge behavior. Many of these models are calibrated and tested at low current densities and cannot be easily transferred to high current densities. Even at low current densities, there is no quantitative method for a researcher to choose a reaction kinetic model such as classical Butler-Volmer and its derivatives, and modified Marcus-Hush-Chidsey, a resistance model for lithium peroxide such as electron transport via tunneling or linear resistivity, a surface coverage model (lithium peroxide growth) such as partial coverage or full coverage, and mass transport model (discussed in Ref. [1]). Also, it is time-consuming to test different models at high current density (1C) due to a lack of well-tested models and well-calibrated model parameters. For this presentation, we will develop an analytical model, which acts as a surrogate model for a sophisticated finite element model to predict discharge time and discharge voltage. Next, we use an uncertainty quantifying technique called reduced-order stochastic optimization [2, 3] to determine the uncertainty in model parameters for rate kinetics, lithium peroxide resistivity, and parasitic resistance. Finally, a finite element simulation is performed to determine the error introduced by the surrogate model and its influence on the uncertainty in the model parameters.

M Mehta↗

Work function reduction in lanthanum hexaboride hollow cathodes operated in gas discharges

Thermal characterization of lanthanum hexaboride (LaB6) hollow cathodes has revealed lower than expected electron emitter temperatures when the cathode reaches steady state. This phenomenon is observed at discharge currents ranging from 5 to 35 A and xenon mass ow rates of 5 to 25 sccm in cathodes with three di erent ori ce diameters. Thus, the accepted value of the work function for polycrystalline LaB6, 2.66 eV, does not describe well the emission characteristics of LaB6 hollow cathodes operating with internal gas discharges at steady state. The measured temperatures and a model of the hollow cathode emitter and xenon discharge were used to estimate the value of the work function in these experiments, yielding a value ranging from 2.1 - 2.44 eV. Measurements of the work function as a function of depth on a hollow cathode emitter using X-ray photoelectron spectroscopy and ion beam milling indicate that the work function in a thin layer near the emitting surface is lower than in the bulk material. We postulate that a lanthanum-rich emitting surface with a lower work function develops as a result of lanthanum recycling in the internal plasma.

Lopez Ortega, Alejandro↗

Electrostatic Discharges from Conductive Thermal Coatings

Selecting the correct thermal control coating for a spacecraft can be a significant challenge. From the start, the process includes balancing conflicting needs. Thermal control paints must have the ability to either absorb or emit heat as desired and this property cannot change beyond a set point over the life of the mission. When the mission involves operating in a heavy charging environment, the control coating must be static dissipative enough to bleed away absorbed energetic electrons to minimize induced electric fields and the risk of electrostatic discharges. Finding the right balance of thermal performance and electrical performance can be difficult for spacecraft designers. In an effort to aid in spacecraft design, a number of white and black thermal control coatings were tested at the Jet Propulsion Laboratory using a two-part test campaign. These tests involved an initial screening test to determine the bulk resistivity of the material using a traditional parallel plate test, but placed in a vacuum chamber immersed in a bath of liquid nitrogen to obtain data over a range of temperatures. The most promising materials were then exposed to a stream of energetic electrons and monitored for the production of electrostatic discharges. Results from these tests indicated that only a few of the common thermal control coatings have a resistivity below 109 ohm-cm as suggested in NASA-HDBK-4002A. Of those that meet this criterion, most will still produce electrostatic discharges when exposed to electrons with energies from 20keV to 60keV while held at cryogenic temperatures. Additional testing is required to characterize additional coatings to create a database that designers may use when selecting an appropriate coating for their application.

Chinn, James↗

Post-test Inspection of NASA’s Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for the discharge chamber as well as other miscellaneous components such as the high-voltage propellant isolators and electrical cabling. Comparison of magnetic field measurements taken during pretest and post-test inspections indicate that the field strength did not degrade, consistent with performance data obtained during the test. Inspection of discharge chamber mesh samples show a deposition coating primarily composed of grid material that is approximately 15 μm in thickness. This thickness is well within the retention capability of the mesh and is therefore not expected to present any issues. Approximately 3.1 grams of deposition flakes were found at the bottom of the discharge chamber, composed primarily of grid material and carbon. Calculated size histograms of these flakes indicate that 99% have a maximum dimension of 200 μm or smaller, which is significantly less than the ion optics grid gap. Larger flakes that are capable of causing a grid-to-grid short will be analyzed to determine if their formation will occur in flight or is a facility effect. The high-voltage propellant isolators as well as numerous other electrical insulators were inspected and no evidence of arcing or any other issues were found.

Rohit Shastry↗

Post-test Inspection of NASA’s Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge and Neutralizer Cathodes

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 h of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for both discharge and neutralizer cathodes. Discharge keeper erosion was found to be significantly reduced from what was observed in the NEXT 2 kh wear test and NSTAR Extended Life Test, providing adequate protection of vital cathode components throughout the test with ample lifetime remaining. The area of the discharge cathode orifice plate that was exposed by the keeper orifice exhibited net erosion, leading to cathode plate material building up in the cathode-keeper gap and causing a thermally-induced electrical short observed during the test. Significant erosion of the neutralizer cathode orifice was also found and is believed to be the root cause of an observed loss in flow margin. Deposition within the neutralizer keeper orifice as well as on the downstream surface was thicker than expected, potentially resulting in a facility-induced impact on the measured flow margin from plume mode. Neutralizer keeper wall erosion on the beam side was found to be significantly lower compared to the NEXT 2 kh wear test, likely due to the reduction in beam extraction diameter of the ion optics that resulted in decreased ion impingement. Results from the post-test inspection have led to some minor thruster design improvements.

Ion engine↗

Low current plasmatron fuel converter having enlarged volume discharges

A novel apparatus and method is disclosed for a plasmatron fuel converter ("plasmatron") that efficiently uses electrical energy to produce hydrogen rich gas. The volume and shape of the plasma discharge is controlled by a fluid flow established in a plasma discharge volume. A plasmatron according to this invention produces a substantially large effective plasma discharge volume allowing for substantially greater volumetric efficiency in the initiation of chemical reactions within a volume of bulk fluid reactant flowing through the plasmatron.

30 DIRECT ENERGY CONVERSION↗

Apparatus for atmospheric pressure pin-to-hole spark discharge and uses thereof

Disclosed herein are atmospheric pressure pin-to-hole pulsed spark discharge devices and methods for creating plasma. The devices include a conduit for fluidically communicating a gas, a plasma, or both, therethrough, portion of the conduit capable of being connected to a gas supply, and a second portion of the conduit capable of emitting a plasma; a positive electrode comprising a sharp tip; and a ground plate electrode. Disclosed are methods for treating a skin ulcer using non-thermal plasma include flowing a gas through a cold spark discharge zone simultaneously with the creation of a pulsed spark discharge to give rise to a non-thermal plasma emitted from a conduit, the non-thermal plasma comprising NO; and contacting a skin ulcer with said non-thermal plasma for sufficient time and intensity to give rise to treatment of the skin ulcer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma spark discharge reactor and durable electrode

A plasma spark discharge reactor for treating water. The plasma spark discharge reactor comprises a HV electrode with a head and ground electrode that surrounds at least a portion of the HV electrode. A passage for gas may pass through the reactor to a location proximate to the head to provide controlled formation of gas bubbles in order to facilitate the plasma spark discharge in a liquid environment.

54 ENVIRONMENTAL SCIENCES↗

Gas discharge tube true random number generator

A hardware random number generator comprises a gas discharge tube, an average voltage generator, and a comparator. The gas discharge tube includes first, second, and third terminals and may generate a variable voltage on the second terminal when a supply voltage is applied to the first and third terminals. The average voltage generator receives the variable voltage from the gas discharge tube and may generate an average voltage equal to a moving average value of the variable voltage over successive periods of time. The comparator receives the variable voltage and the average voltage and may generate a random stream of data bits, such that a value of each bit varies according to the relative magnitudes of the variable voltage and the average voltage.

42 ENGINEERING↗

Apparatus for atmospheric pressure pin-to-hole spark discharge and uses thereof

Disclosed herein are atmospheric pressure pin-to-hole pulsed spark discharge devices and methods for creating plasma. The devices include a conduit for fluidically communicating a gas, a plasma, or both, therethrough, portion of the conduit capable of being connected to a gas supply, and a second portion of the conduit capable of emitting a plasma; a positive electrode comprising a sharp tip; and a ground plate electrode. Disclosed are methods for treating a skin ulcer using non-thermal plasma include flowing a gas through a cold spark discharge zone simultaneously with the creation of a pulsed spark discharge to give rise to a non-thermal plasma emitted from a conduit, the non-thermal plasma comprising NO; and contacting a skin ulcer with said non-thermal plasma for sufficient time and intensity to give rise to treatment of the skin ulcer.

Dobrynin, Danil V.↗

Multi-electrode/multi-modal atmospheric pressure glow discharge plasma ionization device

Apparatus include an atmospheric pressure glow discharge (APGD) analyte electrode defining an analyte discharge axis into an APGD volume, and a plurality of APGD counter electrodes having respective electrical discharge ends directed to the APGD volume, wherein the APGD analyte electrode and the APGD counter electrodes are configured to produce an APGD plasma in the APGD volume with a voltage difference between the APGD analyte electrode and one or more of the AGPD counter electrodes. An electrode can be integrated into an ion inlet. Apparatus can be configured to perform auto-ignition and/or provide multi-modal operation through selectively powering electrodes. Electrode holder devices are disclosed. Related methods are disclosed.

Koppenaal, David W.↗

Electric-pulse discharge as a novel technique to synthesize {beta}-SiC nano-crystallites from liquid-phase organic precursors

{beta}-SiC nano-crystallites have been prepared by electric pulses discharged in liquid-phase organic precursors. The composition and crystal structure of the products were characterized by X-ray diffraction, Raman spectroscopy, field emission scanning electronic and transmission electron microscopy. Transmission electron microscopy showed that the sample synthesized from the precursor (hexamethyl disilane) is composed of uniform grains with only 8 nm, while the one synthesize from the other precursor (dimethyl silicone oil) is of better crystalline structure with average grain size 22 nm, which may be attributed to discharge in liquid-phase source and short discharge intervals.

36 MATERIALS SCIENCE↗

The Zero-Discharge Policy and its Implications for Tritium Inventory at Columbia Generating Station

Columbia Generating Station, a boiling water reactor (BWR), has not made a discharge of radioactive liquids to the Columbia River since 1998. A concern raised when this zero-discharge policy was first considered was that radioactive tritium produced during plant operation would be concentrated in reactor plant water due to the reduced rate at which tritiated water is replaced with makeup water. Elevated concentration of tritium in plant systems could result in internal exposure, especially during refueling outages when personnel are working in the vicinity of the reactor cavity. Tritium data before and after implementation of the zero-discharge policy demonstrate that there has been no significant effect on tritium concentration in plant systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Firearm discharge location systems and methods

Firearm discharge location systems and methods are described. According to one aspect, a firearm discharge location system includes a plurality of microphones spaced from one another, timing circuitry configured to generate a plurality of asynchronous timing references, wherein data capture operations with respect to the microphones of a first pair are synchronized with one another using a first of the timing references and data capture operations with respect to the microphones of a second pair are synchronized with one another using a second of the timing references, and processing circuitry configured to use outputs of the first and second pairs of the microphones to identify a location of a firearm discharge.

Gonzalez, Eric G.↗