Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cost”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Wind Energy Costs in Puerto Rico Through 2035

In 2019, Puerto Rico codified into law a 100% renewable electricity by 2050 target. Decision makers there need information about the costs and performance of wind energy technologies to incorporate into planning efforts for the future grid. After consulting with key technical stakeholders and accounting for unique conditions in Puerto Rico like increased hurricane risks, we customize NREL's Renewable Energy Potential model to calculate how capital expenditures, operational expenditures, net annual energy generation, and levelized cost of energy (LCOE) vary in time and space for wind energy projects around Puerto Rico. Wind turbines can add value by providing grid services through grid-forming inverters and complement solar energy generation with evening and nighttime electricity production, especially offshore. By 2035, we expect average costs of land-based and offshore wind energy in Puerto Rico to reach $\$$69/MWh (6.9 cents/kWh) and $\$$100/MWh (10 cents/kWh), respectively. While these projections do not include transmission system upgrade costs, they do suggest that low-cost, clean electricity is possible for Puerto Rico.

17 WIND ENERGY↗

Levelized Cost of Charging Electric Vehicles

This data set includes the levelized cost of charging (LCOC) and lifetime fuel cost savings (LFCS) values as reported in "Levelized Cost of Charging of Electric Vehicles in the United States." Values are reported at the state and national levels for battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs). The data set also includes the four annual direct current fast charging (DCFC) station load profiles used to approximate the levelized cost of DCFC charging. Each profile provides 15-min resolved power requirements for one full year. Borlaug, B., Salisbury, S., Gerdes, M., and Muratori, M., Levelized Cost of Charging Electric Vehicles in the United States, Joule (2020), https://doi.org/10.1016/j.joule.2020.05.013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Levelized Cost of Charging Electric Vehicles

This data set includes the levelized cost of charging (LCOC) and lifetime fuel cost savings (LFCS) values as reported in "Levelized Cost of Charging of Electric Vehicles in the United States." Values are reported at the state and national levels for battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs). The data set also includes the four annual direct current fast charging (DCFC) station load profiles used to approximate the levelized cost of DCFC charging. Each profile provides 15-min resolved power requirements for one full year. Borlaug, B., Salisbury, S., Gerdes, M., and Muratori, M., Levelized Cost of Charging Electric Vehicles in the United States, Joule (2020), https://doi.org/10.1016/j.joule.2020.05.013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-economic analysis of using corn stover to supply heat and power to a corn ethanol plant - Part 1: Cost of feedstock supply logistics

Supply of corn stover to produce heat and power for a typical 170 dam3 dry mill ethanol plant is proposed. The corn ethanol plant requires 5.6 MW of electricity and 52.3 MW of process heat, which creates the annual stover demand of as much as 140 Gg. The corn stover supply system consists of collection, preprocessing, transportation and on-site fuel storage and preparation to produce heat and power for the ethanol plant. Economics of the entire supply system was conducted using the Integrated Biomass Supply Analysis and Logistics (IBSAL) simulation model. Corn stover was delivered in three formats (square bales, dry chops and pellets) to the combined heat and power plant. Delivered cost of biomass ready to be burned was calculated at 73 $ Mg-1 for bales, 86 $ Mg-1 for pellets and 84 $ Mg-1 for field chopped biomass. Among the three formats of stover supply systems, delivered cost of pelleted biomass was the highest due to high pelleting cost. Bulk transport of biomass in the form of chops and pellets can provide a promising future biomass supply logistic system in the US, if the costs of pelleting and transport are minimized.

collection cost↗

A Cost-Performance Analysis of a Sodium Heat Engine for Distributed Concentrating Solar Power

We present that a sodium thermal electrochemical converter (Na-TEC) generates electricity directly from heat through isothermal expansion of sodium ions across a beta"-alumina solid-electrolyte. This heat engine has been considered for use with conventional concentrating solar power (CSP) systems before. However, unlike previous single-stage devices, the improved design uses two stages with an interstage reheat, allowing more economical and efficient conversion up to 29% at a hot side temperature of 850 °C. Herein, a cost-performance analysis for this improved design assesses opportunities for distributed-CSP in the context of micro-combined heat and power systems. A high-level techno-economic analysis (TEA) is presented that explores four scenarios where a Na-TEC is used as the heat engine for a distributed-CSP system. Overnight capital cost and levelized cost of electricity (LCOE) are estimated for a system lifetime of 30 years, revealing that overnight capital costs in a range from $3.57 to $17.71 per W e are feasible, which equate to LCOEs from 6.9 to 17.2 cents kWh e -1 . This analysis makes a significant contribution by concurrently quantifying the efficiency and unit costs for a range of multistage configurations, and demonstrating that a Na-TEC may be a promising alternative to Stirling engines for distributed-CSP systems at residential scale of 1–5 kW e .

14 SOLAR ENERGY↗

Measuring environmental and cost benefits of riparian buffers for drinking water production in a Midwest watershed

Here, this study focuses on the economic value and carbon benefits of riparian buffers in urban drinking water production. The impact of riparian buffers on the waterworks operation in the Raccoon River watershed was quantified using the following metrics: nitrate concentration, days of nitrate removal operation, material and energy cost (based on 17 years of historical records with a watershed model), regression, and cost analysis. The findings indicate that the presence of riparian buffers in agricultural land can substantially decrease nitrate concentration in the water intake of the waterworks during the crop-growing season: 19% in April, 9% in May, and 11% in June. These reductions mean less nitrate treatment of the plant intake flow: 23% in April, 12% in May, and 3% in June. These changes lead to significant resource savings: 425 metric tons of sodium chloride (NaCl), 147 810 kWh of electricity, 253 metric tons of powdered activated carbon, and 20.8 million liters of fresh water. The buffers would also reduce greenhouse gas emissions by 86.9 metric tons (CO 2 equivalent) in 17 years. The total cost saving was estimated at $\$$327 326, with the highest potential savings in May ($\$$215 100), followed by April ($\$$65 465), and June ($\$$46 761). When factoring in buffer installation, cropland loss, nitrate removal, and cost associated with buffer harvest for biofuel in an established biomass market, the benefit to the entire watershed community would be $\$$2.63 million annually. The results underscore the significant cost benefits and environmental benefits associated with cropland riparian buffers in a watershed community. The approach employed in this study holds promise for assessing riparian buffer benefits in other watersheds, contributes to an understanding of sustainable water management practices, and provides a basis for decision making in a wide range of agricultural regions.

54 ENVIRONMENTAL SCIENCES↗

III-Vs at Scale: A PV Manufacturing Cost Analysis of the Thin Film Vapor-Liquid-Solid Growth Mode

The authors present a manufacturing cost analysis for producing thin-film indium phosphide modules by combining a novel thin-film vapor-liquid-solid (TF-VLS) growth process with a standard monolithic module platform. The example cell structure is ITO/n-TiO2/p-InP/Mo. For a benchmark scenario of 12% efficient modules, the module cost is estimated to be $0.66/W(DC) and the module cost is calculated to be around $0.36/W(DC) at a long-term potential efficiency of 24%. The manufacturing cost for the TF-VLS growth portion is estimated to be ~$23/m2, a significant reduction compared with traditional metalorganic chemical vapor deposition. The analysis here suggests the TF-VLS growth mode could enable lower-cost, high-efficiency III-V photovoltaics compared with manufacturing methods used today and open up possibilities for other optoelectronic applications as well.

14 SOLAR ENERGY↗

Aeration costs in stirred-tank and bubble column bioreactors

To overcome knowledge gaps in the economics of large-scale aeration for production of commodity products, Aspen Plus is used to simulate steady-state oxygen delivery in both stirred-tank and bubble column bioreactors, using published engineering correlations for oxygen mass transfer as a function of aeration rate and power input, coupled with new equipment cost estimates developed in Aspen Capital Cost Estimator and validated against vendor quotations. Here, these simulations describe the cost efficiency of oxygen delivery as a function of oxygen uptake rate and vessel size, and show that capital and operating costs for oxygen delivery drop considerably moving from standard-size (200 m 3 ) to world-class size (500 m 3 ) reactors, but only marginally in further scaling up to hypothetically large (1000 m 3 ) reactors. Finally, this analysis suggests bubble-column reactor systems can reduce overall costs for oxygen delivery by 10-20% relative to stirred tanks at low to moderate oxygen transfer rates up to 150 mmol/L-h.

09 BIOMASS FUELS↗

Tradeoffs among indoor air quality, financial costs, and CO 2 emissions for HVAC operation strategies to mitigate indoor virus in U.S. office buildings

Adapting building operation during the COVID-19 pandemic to improve indoor air quality (IAQ) while ensuring sustainable solutions in terms of costs and CO 2 emissions is challenging and limited in literature. Our previous study investigated different HVAC operation strategies, including increased filtration using MERV 10, MERV 13, or HEPA filters, as well as supplying 100% outdoor air into buildings for a system initially sized for MERV 10 filtration. This paper significantly extends that research by systematically analyzing the potential financial and environmental impact for different locations in the U.S. The previous medium office building system model is improved to account for operation in different climates. New evaluation metrics are created to consider the comprehensive impact of improving IAQ on costs and CO 2 emissions, using dynamic emission factors for electricity generation depending on the location. HVAC operation strategies are studied in five different locations across the United States, with distinct climates and electricity sources. In four of the five locations, MERV 13 filtration offers the best improvement in IAQ per increase in costs and emissions relative to MERV 10. The exception is the mildest climate of San Diego, where use of 100% outdoor air provides the best IAQ with a limited increase in costs and emissions. Finally, a system not sized for HEPA filtration can lead to increased costs and emissions without much improvement in IAQ.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost-effectiveness Analysis on Measures to Improve China's Coal-fired Industrial Boiler

Tackling coal-burning industrial boiler is becoming one of the key programs to solve the environmental problem in China. Assessing the economics of various options to address coal-fired boiler is essential to identify cost-effective solutions. This paper discusses our work in conducting a cost-effectiveness analysis on various types of improvement measures ranging from energy efficiency retrofits to switch from coal to other fuels in China. Sensitivity analysis was also performed in order to understand the impacts of some economic factors such as discount rate and energy price on the economics of boiler improvement options. The results show that nine out of 14 solutions are cost-effective, and a lower discount rate and higher energy price will result in more energy efficiency measures being cost-effective. Both monetary and non-monetary barriers to energy-efficiency improvement are discussed and policies to tackle these barriers are recommended. Our research aims at providing a methodology to assess cost-effective solutions to boiler problems.

01 COAL, LIGNITE, AND PEAT↗

Estimating the uncertainty of damage costs of pollution: A simple transparent method and typical results

Whereas the uncertainty of environmental impacts and damage costs is usually estimated by means of a Monte Carlo calculation, this paper shows that most (and in many cases all) of the uncertainty calculation involves products and/or sums of products and can be accomplished with an analytic solution which is simple and transparent. We present our own assessment of the component uncertainties and calculate the total uncertainty for the impacts and damage costs of the classical air pollutants; results for a Monte Carlo calculation for the dispersion part are also shown. The distribution of the damage costs is approximately lognormal and can be characterized in terms of geometric mean {mu}{sub g} and geometric standard deviation {sigma}{sub g}, implying that the confidence interval is multiplicative. We find that for the classical air pollutants {sigma}{sub g} is approximately 3 and the 68% confidence interval is [{mu}{sub g} / {sigma}{sub g}, {mu}{sub g}{sigma}{sub g}]. Because the lognormal distribution is highly skewed for large {sigma}{sub g}, the median is significantly smaller than the mean. We also consider the case where several lognormally distributed damage costs are added, for example to obtain the total damage cost due to all the air pollutants emitted by a power plant, and we find that the relative error of the sum can be significantly smaller than the relative errors of the summands. Even though the distribution for such sums is not exactly lognormal, we present a simple lognormal approximation that is quite adequate for most applications.

54 ENVIRONMENTAL SCIENCES↗

Assessment of external costs for transport project evaluation: Guidelines in some European countries

Many studies about the external costs generated by the transport system have been developed in the last twenty years. To standardize methodologies and assessment procedures to be used in the evaluation of the projects, some European countries recently have adopted specific guidelines that differ from each other in some aspects even sensibly. This paper presents a critical analysis of the British, Italian and German guidelines and is aimed at cataloguing the external cost types regarded and the assessment methods indicated as well as to highlight the differences of the results, in terms of applicability and reliability. The goal is to contribute to a European standardization process that would lead to the drafting of guidelines suited for all EU countries. - Highlights: • The analyzed guidelines agree on the methods to evaluate costs from air pollution, greenhouse gases and accidents. • They recommend respectively: dose-resp. approach; costs to reduce/permit emissions; whole direct, indirect and social costs. • For noise, DE guide indicates defensive expenditure or SP methods; IT guide, SP method; UK guide, the hedonic prices one. • For on territory impact, DE guide regards only the barrier effect; the IT one, also the soil consumption and system effects. • British guide proposes a qualitative methodology to estimate the impact on various landscapes and environments.

54 ENVIRONMENTAL SCIENCES↗

A system-level cost-of-energy wind farm layout optimization with landowner modeling

This work applies an enhanced levelized wind farm cost model, including landowner remittance fees, to determine optimal turbine placements under three landowner participation scenarios and two land-plot shapes. Instead of assuming a continuous piece of land is available for the wind farm construction, as in most layout optimizations, the problem formulation represents landowner participation scenarios as a binary string variable, along with the number of turbines. The cost parameters and model are a combination of models from the National Renewable Energy Laboratory (NREL), Lawrence Berkeley National Laboratory, and Windustiy. The system-level cost-of-energy (COE) optimization model is also tested under two land-plot shapes: equally-sized square land plots and unequal rectangle land plots. The optimal COEs results are compared to actual COE data and found to be realistic. The results show that landowner remittances account for approximately 10% of farm operating costs across all cases. Irregular land-plot shapes are easily handled by the model. We find that larger land plots do not necessarily receive higher remittance fees. The model can help site developers identify the most crucial land plots for project success and the optimal positions of turbines, with realistic estimates of costs and profitability. (C) 2013 Elsevier Ltd. All rights reserved.

36 MATERIALS SCIENCE↗

Levelized cost of charging of extreme fast charging with stationary LMO/LTO batteries

Extreme DC fast charging for electric vehicles (EVs) could be competitive with the internal combustion engine refueling experience and enable longer-distance travel, which could help with EV adoption and decarbonization, but these systems have high capital costs and extremely variable high-power demands. Behind-the-meter systems (BTMS) could support extreme-fast-charging (XFC) stations to increase nationwide adoption of EVs. Here, this study examines the optimal break-even levelized cost of charging (LCOC) across 96 BTMS scenarios to enable low-wait XFC stations providing 200 miles of charge in 10 min. This research simulates LCOC via synthetic XFC-capable EV loads, machine-learned battery life models from testing data, and nonlinear optimal controls, co-minimizing complex utility costs and battery replacements. An aggregate optimal BTMS design treating each EV load as equal likely gives an optimal LCOC per utility rate, the average of which is $\$$0.59/kWh. In addition, the sensitivity of optimal and off-optimal design factors, the long-life LMO/LTO chemistry, and optimized controls are analyzed. The battery control model, based on battery stressors to compare chemistries, optimizes LMO/LTO resting state of charge and cycle depth without compromising cost reduction, which enables greater flexibility in operation. The LCOC savings due to replacement reduction are small, up to $\$$0.035/kWh (6%), with an average of $\$$0.02/kWh (3.5%). Compared with gasoline stations, the aggregate XFC station design achieves comparable speed, experience of service, and cost at $\$$3.81/gal gasoline, showing that EVs can replace gasoline vehicles even for longer-distance travel.

25 ENERGY STORAGE↗

Cost-optimized energy storage operation for a grid-connected solar PV system at community and individual scales

This study provides a comparative analysis of grid-connected PV-integrated battery storage at individual and community scales. The paper addresses the challenge of managing energy demand-generation mismatch by using a battery energy storage optimization algorithm, which minimizes operational costs while accounting for battery degradation. Also, this work introduces a broader evaluation basis that includes seasonal variability, grid exchange smoothness, and scalability across different battery capacities. Results show that community-scale storage more effectively dampens grid exchange power fluctuations and reduces system costs, particularly with moderate price differences between electricity buying and selling prices and low battery capacities. The paper also analyzes the impacts of static control versus cost-optimized battery system management. Here, it is shown that the gap in system costs between the cost-optimized and static control scenarios widens as the price difference increases.

25 ENERGY STORAGE↗

Low-Dose Chest Computed Tomography for Lung Cancer Screening Among Hodgkin Lymphoma Survivors: A Cost-Effectiveness Analysis

Purpose: Hodgkin lymphoma (HL) survivors face an increased risk of treatment-related lung cancer. Screening with low-dose computed tomography (LDCT) may allow detection of early stage, resectable cancers. We developed a Markov decision-analytic and cost-effectiveness model to estimate the merits of annual LDCT screening among HL survivors. Methods and Materials: Population databases and HL-specific literature informed key model parameters, including lung cancer rates and stage distribution, cause-specific survival estimates, and utilities. Relative risks accounted for radiation therapy (RT) technique, smoking status (>10 pack-years or current smokers vs not), age at HL diagnosis, time from HL treatment, and excess radiation from LDCTs. LDCT assumptions, including expected stage-shift, false-positive rates, and likely additional workup were derived from the National Lung Screening Trial and preliminary results from an internal phase 2 protocol that performed annual LDCTs in 53 HL survivors. We assumed a 3% discount rate and a willingness-to-pay (WTP) threshold of $50,000 per quality-adjusted life year (QALY). Results: Annual LDCT screening was cost effective for all smokers. A male smoker treated with mantle RT at age 25 achieved maximum QALYs by initiating screening 12 years post-HL, with a life expectancy benefit of 2.1 months and an incremental cost of $34,841/QALY. Among nonsmokers, annual screening produced a QALY benefit in some cases, but the incremental cost was not below the WTP threshold for any patient subsets. As age at HL diagnosis increased, earlier initiation of screening improved outcomes. Sensitivity analyses revealed that the model was most sensitive to the lung cancer incidence and mortality rates and expected stage-shift from screening. Conclusions: HL survivors are an important high-risk population that may benefit from screening, especially those treated in the past with large radiation fields including mantle or involved-field RT. Screening may be cost effective for all smokers but possibly not for nonsmokers despite a small life expectancy benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trends in Local Therapy Utilization and Cost for Early-Stage Breast Cancer in Older Women: Implications for Payment and Policy Reform

Purpose: Older women with early-stage disease constitute the most rapidly growing breast cancer demographic, yet it is not known which local therapy strategies are most favored by this population in the current era. Understanding utilization trends and cost of local therapy is important for informing the design of bundled payment models as payers migrate away from fee-for-service models. We therefore used the Surveillance, Epidemiology, and End Results Medicare database to determine patterns of care and costs for local therapy among older women with breast cancer. Methods and Materials: Treatment strategy and covariables were determined in 55,327 women age ≥66 with Tis-T2N0-1M0 breast cancer who underwent local therapy between 2000 and 2008. Trends in local therapy were characterized using Joinpoint. Polychotomous logistic regression determined predictors of local therapy. The median aggregate cost over the first 24 months after diagnosis was determined from Medicare claims through 2010 and reported in 2014 dollars. Results: The median age was 75. Local therapy distribution was as follows: 27,896 (50.3%) lumpectomy with external beam radiation, 18,356 (33.1%) mastectomy alone, 6159 (11.1%) lumpectomy alone, 1488 (2.7%) mastectomy with reconstruction, and 1455 (2.6%) lumpectomy with brachytherapy. Mastectomy alone declined from 39.0% in 2000 to 28.2% in 2008, and the use of breast conserving local therapies rose from 58.7% to 68.2%. Mastectomy with reconstruction was more common among the youngest, healthiest patients, whereas mastectomy alone was more common among patients living in rural low-income regions. By 2008, the costs were $36,749 for lumpectomy with brachytherapy, $35,030 for mastectomy with reconstruction, $31,388 for lumpectomy with external beam radiation, $21,993 for mastectomy alone, and $19,287 for lumpectomy alone. Conclusions: The use of mastectomy alone in older women declined in favor of breast conserving strategies between 2000 and 2008. Using these cost estimates, price points for local therapy bundles can be constructed to incentivize the treatment strategies that confer the highest value.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A low-cost sulfate-based all iron redox flow battery

Redox flow batteries (RFBs) are promising choices for stationary electric energy storage. Nevertheless, commercialization is impeded by high-cost electrolyte and membrane materials. Here, we report a low-cost all-iron RFB that features inexpensive FeSO 4 electrolytes, microporous membrane along with a glass fiber separator. The addition of 0.1 м 1-ethyl-3-methylimidazolium chloride (EMIC) overcomes the low solubility of FeSO 4 in water which is raised to 2.2 м. DFT calculations demonstrate that EMI + can strengthen the interaction between sulfate anions and water molecules. This electrolyte composition also allows both anode and cathode reactions to operate without actively maintaining a pH gradient between them, thus eliminating the need for expensive ion exchange membranes. The all-iron RFB demonstrates stable operation at a current density of 20 mA cm –2 for more than 800 cycles via a simple, periodic regeneration process. Furthermore, the system cost of FeSO 4 /EMIC RFBs is projected to be $ 50 per kWh due to its low-cost active materials and the inexpensive microporous membrane. Finally, this low-cost, high-concentration all-iron RFB is a promising stationary energy–storage system for storing renewable energy.

25 ENERGY STORAGE↗