Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Thermal control surfaces experiment (SOO69) flight systems performance

The thermal control surfaces experiment (TCSE) was the most complex hardware system aboard the Long Duration Exposure Facility (LDEF). The TCSE system consists of a scanning spectroreflectometer that measured test samples mounted on a rotatable carousel assembly. A microprocessor based data system controlled all aspects of TCSE system operation. Power was provided by four primary batteries. Flight measurement and housekeeping data were stored on a tape recorder for postflight analysis. The TCSE is a microcosm of complex electro-optical payloads being developed by NASA, DoD, and the aerospace community. The TCSE provides valuable data on the performance of these systems in space. The TCSE flight system and its excellent performance on the LDEF mission are described. A few operational anomalies were encountered and are discussed. Initial post-flight tests show that the TCSE system remains functional although some degradation in the optical measurements were observed. The results of these tests are also presented.

Wilkes, Donald R.↗

Modification by food of the calcium absorbability and physicochemical effects of calcium citrate

The food-calcium (Ca) interaction was examined in 12 healthy women (mean age 38 years) maintained on a constant metabolic diet. They underwent three phases of study, comprised of control (no Ca), Ca citrate (1 g Ca/day) during meals, and Ca citrate separately from meals. Each phase was 7 days in length and two 24-hour urine samples were collected on days 6 and 7. The rise from the control phase in urinary Ca was slightly more prominent when Ca citrate was given with meals than without (68 and 62%, respectively). The fall in urinary phosphorus was equivalent at about 25% between Ca citrate phases. The rise in urinary citrate and pH and the decline in urinary ammonium were more prominent when Ca citrate was given with meals; however, the changes were small or nonsignificant. The urinary saturation of Ca oxalate, brushite or monosodium urate did not differ between the two Ca citrate phases. There was a nonsignificant rise in serum iron during Ca citrate phases. The results suggest that: 1) dissolution and absorption of Ca citrate might be slightly greater when given with food than without; 2) that the ability of Ca citrate to attenuate crystallization of stone-forming Ca salts in urine is not modified by food; and 3) that Ca citrate may not impair iron absorption from food.

Non-NASA Center↗

Development of a Work Control System for Propulsion Testing at NASA Stennis

This paper will explain the requirements and steps taken to develop the current Propulsion Test Directorate electronic work control system for Test Operations. The PTD Work Control System includes work authorization and technical instruction documents, such as test preparation sheets, discrepancy reports, test requests, pre-test briefing reports, and other test operations supporting tools. The environment that existed in the E-Complex test areas in the late 1990's was one of enormous growth which brought people of diverse backgrounds together for the sole purpose of testing propulsion hardware. The problem that faced us was that these newly formed teams did not have a consistent and clearly understood method for writing, performing or verifying work. A paper system was developed that would allow the teams to use the same forms, but this still presented problems in the large amount of errors occurring, such as lost paperwork and inconsistent implementation. In a sampling of errors in August 1999, the paper work control system encountered 250 errors out of 230 documents released and completed, for an error rate of 111%.

Messer, Elizabeth A.↗

Levitation Technology in International Space Station Research

The International Space Station (ISS) is a unique multidisciplinary orbiting laboratory for science and technology research, enabling discoveries that benefit life on Earth and exploration of the universe. ISS facilities for containerless sample processing in Materials Science experiments include levitation devices with specimen positioning control while reducing containment vessel contamination. For example, ESA's EML (ElectroMagnetic Levitator), is used for melting and solidification of conductive metals, alloys, or semiconductors in ultra-high vacuum, or in high-purity gaseous atmospheres. Sample heating and positioning are accomplished through electromagnetic fields generated by a coil system. EML applications cover investigation of solidification and microstructural formation, evaluation of thermophysical properties of highly reactive metals (whose properties can be very sensitive to contamination), and examination of undercooled liquid metals to understand metastable phase convection and influence convection on structural changes. MSL utilization includes development of novel light-weight, high-performance materials. Another facility, JAXA's ELF (Electrostatic Levitation Furnace), is used to perform high temperature melting while avoiding chemical reactions with crucibles by levitating a sample through Coulomb force. ELF is capable of measuring density, surface tension, and viscosity of samples at high temperatures. One of the initial ELF investigations, Interfacial Energy-1, is aimed at clarification of interfacial phenomena between molten steels and oxide melts with industrial applications in control processes for liquid mixing. In addition to these Materials Science facilities, other ISS investigations that involve levitation employ it for biological research. For example, NASA's "Magnetic 3D Culturing and Bioprinting" investigation uses magnetic levitation for three-dimensional culturing and positioning of magnetized cells to generate spheroid assemblies for biomedical applications. Levitation is also used as a modeled microgravity ground analog in the NASA OsteoOmics ISS investigation, which tests whether magnetic levitation accurately simulates microgravity conditions by studying gravitational regulation of osteoblast and osteoclast genomics and metabolism. Elucidating the cellular mechanisms of bone loss in microgravity contributes to the understanding of bone loss in medical disorders on Earth, which may lead to development of preventive or therapeutic countermeasures. Thus, the ISS state-of-the-art laboratory offers various levitation capability platforms with applications for innovative research in Materials and Life Sciences disciplines, with benefits for humanity.

Guinart-Ramirez, Y.↗

Cold Survivable Distributed Motor Controller (CSDMC)

This paper presents the results of NASA’s COLDTECH development entitled “Cold Survivable Distributed Motor Controller (CSDMC)”. This work addresses the need to lower the mass, power and volume of the motor control electronics and its associated cabling. Landed payload mass of ocean world missions typically requires a spacecraft launch mass of 7-10x the landed mass due to the required propellant to get the payload to the surface. Reduction of landed mass leads to cheaper, more frequent missions and/or increased science return. This work addresses this need by developing a distributed electronics architecture, which places control and power electronics near or at actuators and instruments. The outcome of this effort will result in a 10X reduction in harness mass, enabling a significant increase in science payload which then enables more capable sample acquisition, delivery and analysis systems on these missions. Placing the control and power conversion electronics at or near the actuators or instruments is the cornerstone of our distributed architecture. To do this, we developed the technology necessary to distribute the electronics and place them on a shared interface and power bus. This enables a significant reduction in cable mass along with its associated complexity. This allows spacecraft designers to take advantage of volume at the extremities that would normally not be utilized. In this paper we discuss the technologies and system design to achieve these goals in support of ocean world missions. These technologies include the development of our motor control modules, a point of load regulator and isolated converter modules along with the packaging technology necessary to allow our electronics to survive the extreme temperatures.

Stell, Chris↗

Sample Acquisition and Handling System from a Remote Platform

A system has been developed to acquire and handle samples from a suspended remote platform. The system includes a penetrator, a penetrator deployment mechanism, and a sample handler. A gravity-driven harpoon sampler was used for the system, but other solutions can be used to supply the penetration energy, such as pyrotechnic, pressurized gas, or springs. The deployment mechanism includes a line that is attached to the penetrator, a spool for reeling in the line, and a line engagement control mechanism. The penetrator has removable tips that can collect liquid, ice, or solid samples. The handling mechanism consists of a carousel that can store a series of identical or different tips, assist in penetrator reconfiguration for multiple sample acquisition, and deliver the sample to a series of instruments for analysis. The carousel sample handling system was combined with a brassboard reeling mechanism and a penetrator with removable tips. It can attach the removable tip to the penetrator, release and retrieve the penetrator, remove the tip, and present it to multiple instrument stations. The penetrator can be remotely deployed from an aerobot, penetrate and collect the sample, and be retrieved with the sample to the aerobot. The penetrator with removable tips includes sample interrogation windows and a sample retainment spring for unconsolidated samples. The line engagement motor can be used to control the penetrator release and reeling engagement, and to evenly distribute the line on the spool by rocking between left and right ends of the spool. When the arm with the guiding ring is aligned with the spool axis, the line is free to unwind from the spool without rotating the spool. When the arm is perpendicular to the spool axis, the line can move only if the spool rotates.

Badescu, Mircea↗

Contamination Knowledge Strategy for the Mars 2020 Sample-Collecting Rover

The Mars 2020 rover will collect carefully selected samples of rock and regolith as it explores a potentially habitable ancient environment on Mars. Using the drill, rock cores and regolith will be collected directly into ultraclean sample tubes that are hermetically sealed and, later, deposited on the surface of Mars for potential return to Earth by a subsequent mission. Thorough characterization of any contamination of the samples at the time of their analysis will be essential for achieving the objectives of Mars returned sample science (RSS). We refer to this characterization as contamination knowledge (CK), which is distinct from contamination control (CC). CC is the set of activities that limits the input of contaminating species into a sample, and is specified by requirement thresholds. CK consists of identifying and characterizing both potential and realized contamination to better inform scientific investigations of the returned samples. Based on lessons learned by other sample return missions with contamination-sensitive scientific objectives, CC needs to be "owned" by engineering, but CK needs to be "owned" by science. Contamination present at the time of sample analysis will reflect the sum of contributions from all contamination vectors up to that point in time. For this reason, understanding the integrated history of contamination may be crucial for deciphering potentially confusing contaminant-sensitive observations. Thus, CK collected during the Mars sample return (MSR) campaign must cover the time period from the initiation of hardware construction through analysis of returned samples in labs on Earth. Because of the disciplinary breadth of the scientific objectives of MSR, CK must include a broad spectrum of contaminants covering inorganic (i.e., major, minor, and trace elements), organic, and biological molecules and materials.

Farley, K. A.↗

Constraining the Surface Exposure Age of Asteroid Bennu Using Cosmogenic Radionuclides in an OSIRIS-REx Aggregate Sample and Individual Particles

Observations by NASA’s OSIRIS-REx spacecraft of asteroid Bennu revealed evidence that this small rubble-pile asteroid experiences several active surface processes that likely control its recent surface exposure history. In October 2020, the spacecraft collected a surface sample from a relatively young ~20 m diameter crater (Hokioi) on asteroid Bennu, and the sample was successfully delivered to Earth on September 24, 2023. Based on the population of craters >50 m diameter, Bennu’s surface is 0.1–1 Ga old, but the old surface is affected by recent processes including smaller meteoroid impacts, mass movement, and particle ejections. The sampling location within Hokioi crater was selected based on its relatively flat surface devoid of large boulders, but the crater floor is also believed to be one of the youngest surfaces on asteroid Bennu, with an age of <100 kyr. As the crater is ~2 m deep, the samples that were collected by OSIRIS-REx may have been relatively shielded from cosmic rays during most of its recent history. This scenario is different from the samples that were collected by Hayabusa2 from asteroid Ryugu, where cosmogenic noble gas and radionuclides indicate cosmic-ray exposure (CRE) ages of ~5 Myr near the surface. Our goal is to understand the recent exposure history of surface samples of asteroid Bennu utilizing radionuclides ( 10 Be, 26 Al, 36 Cl, 41 Ca) produced by both galactic (GCR) and solar (SCR) cosmic rays. With half- lives ranging from 0.1 to 1.36 million years (Myr), the concentrations of these cosmogenic nuclides provide information on the duration and exposure conditions (irradiation depth) of these samples on a timescale of a few Myr. This work will test one of the OSIRIS-REx mission’s driving hypotheses about asteroid Bennu’s recent evolution: that Hokioi crater is part of a population of small (25 m) spectrally red craters on Bennu that are less than 0.1 Myr old.

K. C. Welten↗

STS-113/11A: Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned in December 2002 and in May 2003 aboard Soyuz 5

The toxicological assessments of grab sample canisters (GSCs) returned aboard STS-l13 and Soyuz 5 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSCs were 79-120% except as noted in the table. One sample was returned with the valve opened. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Octafluoropropane (OFP) has leaked from heat-exchange units in large quantities, so its concentration is tracked separately. Because formaldehyde is quantified from sorbent badges, its concentration is also listed separately. The table shows that the air quality in general was acceptable for crew respiration through the middle of December 2002. No conclusions can be made about the air quality after that date due to NASA's inability to return air samples from the ISS . Alcohols are not being controlled to the recently lowered guideline of 5 mg/m3, which was recommended to protect the water recovery systems. The airlock sample was taken during the regeneration of Met ox canisters in the adjacent Node. The trace pollutants were not increased above background; however, inspection of table 1 in the appendix shows a CO2 concentration of 17,000 mg/cu m, which is a relatively high concentration, but still below the 24-hour SMAC of23,000 mg/cu m. The control of OFP continues to be adequate at least through December 2002. Formaldehyde concentrations suggest that the high levels that were being found in the Lab atmosphere have subsided. This is probably attributable to the restoration of IMV in early February 2003 . Before the obstructing material was removed from ducts the Lab formaldehyde concentrations approached 0.06 mg/cu m, whereas after the repair the levels were near 0.04 mg/m3 . This does not mean that local sources in the Lab have been reduced, only that the excess of formaldehyde produced in the Lab is distributed into the whole volume of the ISS.

James, John T.↗

The Importance of Water for High Fidelity Information Processing and for Life

Is water an absolute prerequisite for life? Life depends on a variety of non-covalent interactions among molecules, the nature of which is determined as much by the solvent in which they occur as by the molecules themselves. Catalysis and information processing, two essential functions of life, require non-covalent molecular recognition with very high specificity. For example, to correctly reproduce a string consisting of 600,000 units of information (e.g ., 600 kilobases, equivalent to the genome of the smallest free living terrestrial organisms) with a 90% success rate requires specificity > 107 : 1 for the target molecule vs. incorrect alternatives. Such specificity requires (i) that the correct molecular association is energetically stabilized by at least 40 kJ/mol relative to alternatives, and (ii) that the system is able to sample among possible states (alternative molecular associations) rapidly enough to allow the system to fall under thermodynamic control and express the energetic stabilization. We argue that electrostatic interactions are required to confer the necessary energetic stabilization vs. a large library of molecular alternatives, and that a solvent with polarity and dielectric properties comparable to water is required for the system to sample among possible states and express thermodynamic control. Electrostatic associations can be made in non-polar solvents, but the resulting complexes are too stable to be "unmade" with sufficient frequency to confer thermodynamic control on the system. An electrostatic molecular complex representing 3 units of information (e.g., 3 base pairs) with specificity > 107 per unit has a stability in non-polar solvent comparable to that of a carbon-carbon bond at room temperature. These considerations suggest that water, or a solvent with properties very like water, is necessary to support high-fidelity information processing, and can therefore be considered a critical prerequisite for life.

Hoehler, Tori M.↗

Physical and Chemical Toeholds for Exoplanet Bioastronomy

If a search for exoplanet life were mounted today, the likely focus would be to detect oxygen (or ozone) in the atmosphere of a water-bearing rocky planet orbiting roughly 1AU from a G-type star. This appropriately conservative and practical default is necessary in large part because biological input on the question of where and how to look for life has progressed little beyond a purely empirical reliance on the example of terrestrial biology. However, fundamental physical and chemical considerations may impose significant yet universal constraints on biological potential. The liquid water + oxygen paradigm will be considered as an example, with a focus on the question, is liquid water a prerequisite for life? . Life requires a solvent to mediate interactions among biological molecules. A key class of these interactions is molecular recognition with high specificity, which is essential for high fidelity catalysis and (especially) information processing. For example, to correctly reproduce a string consisting of 600,000 units of information (e.g., 600 kilobases, equivalent to the genome of the smallest free living terrestrial organisms) with a 90% success rate requires specificity greater than 10(exp 7):1 for the target molecule vs. incorrect alternatives. Such specificity requires (i) that the correct molecular association is energetically stabilized by at least 40 kJ/mol relative to alternatives, and (ii) that the system is able to sample among possible states (alternative molecular associations) rapidly enough to allow the system to fall under thermodynamic control and express the energetic stabilization. We argue that electrostatic interactions are required to confer the necessary energetic stabilization vs. a large library of molecular alternatives, and that a solvent with polarity and dielectric properties comparable to water is required for the system to sample among possible states and express thermodynamic control. Electrostatic associations can be made in non-polar solvents, but the resulting complexes are too stable to be "unmade" with sufficient frequency to confer thermodynamic control on the system. Such considerations suggest that water, or a solvent with properties very like water, is necessary to support high-fidelity information processing a feature that must be common to all biology and can therefore be considered a critical prerequisite for life.

Hoehler, Tori↗

Containerless processing of undercooled melts

All practical solidification processes involve some level of melt undercooling. Usually in bulk liquids crystallization is initiated at a heterogeneous nucleation site at low undercooling. The realization of appreciable levels of liquid undercooling requires some control over the kinetics of crystal nucleation. One level of control is available in containerless processing where the capability to melt and solidify samples without a container removes a major source of impurities and heterogeneous nucleation sites which can be effective in promoting large undercooling and in studying other potential nucleants. The microgravity environment offers a unique opportunity for containerless processing of large liquid samples with negligible melt disturbance and continuous temperature measurement throughout processing. Perhaps the most important potential for microgravity containerless processing lies in the significant structural control to develop distinct microstructures and metastable phases during solidification at high undercooling.

Perepezko, J. H.↗

Digital approximation of continuous-data control systems by point-by-point state comparison

This paper presents a point-by-point state comparison method of approximating a continuous-data system by a sampled-data system. The problem is to attempt the matching of the states of the two systems at the sampling instants. A partial matching has to be conducted if the systems have more states than controls. A weighting matrix is used to regulate the partial matching and weights placed on each state. The digital approximation is affected by use of forward gain E(T) and feedback gain G(T) in the sampled-data system. It is shown that, in general, these gains can be approximated by truncated Taylor series expansions. An illustrative example is given using the one-axis dynamics of the Skylab satellite.

Kuo, B. C.↗

Spaceflight Effects and Molecular Responses in the Mouse Eye: Observations after NASA Shuttle Mission STS-133

Background: Human space exploration implies a combination of stressors including microgravityinduced cephalad fluid shift and radiation exposure. Ocular changes in astronauts leading to visual impairment are of occupational health relevance. The effect of this complex environment on ocular morphology and function is poorly understood. Material and Methods: Mice were assigned to a Flight (FLT) group flown on shuttle mission STS133, Animal Enclosure Module (AEM), or vivarium (VIV) ground controls. Eyes were collected at 1, 5 and 7 days after landing, and were fixed for histological sectioning. The contralateral eye was used for gene expression profiling by qRT-PCR. Routine histology and immunohistochemistry using 8-hydroxy-2'-deoxyguanosine (8-OHdG), caspase-3, glial fibrillary acidic protein (GFAP) and beta-amyloid were used to study the eyes. Results and Conclusions: 8-OHdG and caspase-3 immunoreactivity was increased in the retina in FLT samples at return from flight (R+1) compared to ground controls, and decreased at day 7 (R+7), suggesting an increase in oxidative stress and cell apoptosis. FLT mice showed evidence of retinal pigment epithelium (RPE) apoptosis possibly secondary to oxidative damage. Although attenuation of RPE has been related to retinal choroidal folds in astronauts, it is yet to be determined whether or not increased RPE apoptosis may contribute to the formation of choroidal folds or may increase the risk for other retinal pathologies, such as AMD. beta-amyloid was seen in the nerve fibers at the post-laminar region of the optic nerve in the flight samples (R+7). Deposition of beta-amyloid has a strong correlation with mechanical trauma. The coexpression of GFAP in astrocytes and oligodentrocytes in these same areas supports the possible mechanical origin probably secondary to intracranial pressure that is transmitted into the nerve, as a result of an increase in venous pressure associated to microgravity-induced cephalic fluid shift. However, there is the need to further investigate the nature of the changes through additional experimental work. Gene expression of oxidative and cellular stress response genes was unregulated in the retina of FLT samples upon landing followed by lower levels by R+7. These results suggest that reversible molecular damage occurs in the retina of mice exposed to spaceflight and that protective cellular and molecular pathways are induced in the retina in response to these changes.

ProsperoPonce, Claudia Maria↗

Rugged, Portable, Real-Time Optical Gaseous Analyzer for Hydrogen Fluoride

Hydrogen fluoride (HF) is a primary evolved combustion product of fluorinated and perfluorinated hydrocarbons. HF is produced during combustion by the presence of impurities and hydrogen- containing polymers including polyimides. This effect is especially dangerous in closed occupied volumes like spacecraft and submarines. In these systems, combinations of perfluorinated hydrocarbons and polyimides are used for insulating wiring. HF is both highly toxic and short-lived in closed environments due to its reactivity. The high reactivity also makes HF sampling problematic. An infrared optical sensor can detect promptly evolving HF with minimal sampling requirements, while providing both high sensitivity and high specificity. A rugged optical path length enhancement architecture enables both high HF sensitivity and rapid environmental sampling with minimal gaseous contact with the low-reactivity sensor surfaces. The inert optical sample cell, combined with infrared semiconductor lasers, is joined with an analog and digital electronic control architecture that allows for ruggedness and compactness. The combination provides both portability and battery operation on a simple camcorder battery for up to eight hours. Optical detection of gaseous HF is confounded by the need for rapid sampling with minimal contact between the sensor and the environmental sample. A sensor is required that must simultaneously provide the required sub-parts-permillion detection limits, but with the high specificity and selectivity expected of optical absorption techniques. It should also be rugged and compact for compatibility with operation onboard spacecraft and submarines. A new optical cell has been developed for which environmental sampling is accomplished by simply traversing the few mm-thick cell walls into an open volume where the measurement is made. A small, low-power fan or vacuum pump may be used to push or pull the gaseous sample into the sample volume for a response time of a few seconds. The optical cell simultaneously provides for an enhanced optical interaction path length between the environmental sample and the infrared laser. Further, the optical cell itself is comprised of inert materials that render it immune to attack by HF. In some cases, the sensor may be configured so that the optoelectronic devices themselves are protected and isolated from HF by the optical cell. The optical sample cell is combined with custom-developed analog and digital control electronics that provide rugged, compact operation on a platform that can run on a camcorder battery. The sensor is inert with respect to acidic gases like HF, while providing the required sensitivity, selectivity, and response time. Certain types of combustion events evolve copious amounts of HF, very little of other gases typically associated with combustion (e.g., carbon monoxide), and very low levels of aerosols and particulates (which confound traditional smoke detectors). The new sensor platform could warn occupants early enough to take the necessary countermeasures.

Pilgrim, Jeffrey↗

On the continuous dependence with respect to sampling of the linear quadratic regulator problem for distributed parameter systems

The convergence of solutions to the discrete or sampled time linear quadratic regulator problem and associated Riccati equation for infinite dimensional systems to the solutions to the corresponding continuous time problem and equation, as the length of the sampling interval (the sampling rate) tends toward zero (infinity) is established. Both the finite and infinite time horizon problems are studied. In the finite time horizon case, strong continuity of the operators which define the control system and performance index together with a stability and consistency condition on the sampling scheme are required. For the infinite time horizon problem, in addition, the sampled systems must be stabilizable and detectable, uniformly with respect to the sampling rate. Classes of systems for which this condition can be verified are discussed. Results of numerical studies involving the control of a heat/diffusion equation, a hereditary of delay system, and a flexible beam are presented and discussed.

Rosen, I. G.↗

X-ray reflection efficiency of nickel-coated quartz optical flats

The reflection efficiency of quartz optical flats vacuum coated with 1000-A nickel was evaluated. Of the three vacuum coated samples tested, two had been contaminated during the firing of the Lunar Module Reaction Control System in the vacuum chamber. Measurements were made for 1.54-, 1.79-, and 2.29-A incident radiation. The reflection efficiency of the contaminated samples was reduced by as much as 50 percent for some angles of incidence.

Reynolds, J. M.↗

Measuring Q And f(sub r) Of A Microwave Cavity: Part I

Method of measuring quality factor (Q) and frequency of resonance (f(subr)) of microwave cavity exploits two inflection points of power-vs.-frequency resonance curve of cavity. Intended particularly for use with microwave cavity in which sample of lossy dielectric material heated to specified high temperature by microwave power at resonant frequency. Accurate measurement contributes to enhanced monitoring and control in contactless high-temperature processing of materials. Also used with small spherical sample to determine temperature dependence of complex dielectric constant.

Barmatz, Martin B.↗