Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

NUHOMS{sup R} EOS (Extended Optimized Storage): Robust, Advanced, and Dual Purpose Dry Storage System - 16472

AREVA TN has completed the design, analysis, and US NRC license submittal for the NUHOMS{sup R} Extended Optimized Storage (EOS) system. NUHOMS{sup R} EOS offers a large capacity and high heat load dry storage and transportation solution for UNF. EOS is not a new system, but an evolution of the already-proven safe and low-risk horizontal NUHOMS{sup R} storage system, which is one of the most widely used UNF dry storage systems in the United States. The EOS system features a 37PTH dry shielded canister (DSC) for 37 PWR UNF assemblies and an 89BTH DSC for the 89 BWR UNF assemblies. The EOS DSCs will be stored inside a horizontal storage module (HSM) that is a robust, fortress-like concrete storage overpack. Designed with the lessons learned from the Fukushima event in Japan in mind, EOS has robust margins for beyond design basis (BDB) events and offers the lowest risk and highest safety margin of any dry storage system design for recovery from BDB events. EOS also offers innovative aging management features with an aging management program (AMP) to assure safe and low dose long-term storage at the utility sites. EOS incorporates ports for AMP inspections and offers the option of using duplex stainless steel (DSS) for the DSC shell in order to negate corrosion issues. EOS is stored horizontally and above ground, making it easy and quick to access for visual inspection, monitoring, and mitigating actions during AMP. NUHOMS{sup R} EOS is optimized for high capacity, high burnup, high enrichments, and very low cooling times for UNF assemblies. It enables the highest heat load per canister (50 kW) and low dose rates. Even with high heat loads, EOS has significant margins to design basis limits. As the future of used fuel disposition will require the need to move fuel off-site to interim or consolidated storage, EOS is the ideal solution as it enables on-site loading and unloading operations that mitigate risk when transferring fuel on-site or transporting fuel off-site. The EOS design can be safely located in a traditional outdoor setting with fortress-like concrete reinforced modules that offer superior resistance to attack or can be safely operated inside of a building enclosure for those utilities desiring a more discreet siting for its used fuel storage systems. EOS has an innovative basket design that is made of high strength low alloy (HSLA) material and is easy to fabricate due to its non-welded design. Its innovative inlet and outlet air vent design, which incorporates dose reduction hardware, allows for optimal ambient airflow for highly efficient heat transfer with minimal radiation dose. The NUHOMS{sup R} EOS storage modules are interlocked in a side-by-side configuration offering superior and robust seismic performance. The license application for NUHOMS{sup R} EOS is currently under US NRC review and this system will be available for deployment in 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Building Organic/Inorganic Hybrid Interphases for Fast Interfacial Transport in Rechargeable Metal Batteries

Abstract We report a facile in situ synthesis that utilizes readily accessible SiCl 4 cross‐linking chemistry to create durable hybrid solid–electrolyte interphases (SEIs) on metal anodes. Such hybrid SEIs composed of Si‐interlinked OOCOR molecules that host LiCl salt exhibit fast charge‐transfer kinetics and as much as five‐times higher exchange current densities, in comparison to their spontaneously formed analogues. Electrochemical analysis and direct optical visualization of Li and Na deposition in symmetric Li/Li and Na/Na cells show that the hybrid SEI provides excellent morphological control at high current densities (3–5 mA cm −2 ) for Li and even for notoriously unstable Na metal anodes. The fast interfacial transport attributes of the SEI are also found to be beneficial for Li‐S cells and stable electrochemical cycling was achieved in galvanostatic studies at rates as high as 2 C. Our work therefore provides a promising approach towards rational design of multifunctional, elastic SEIs that overcome the most serious limitations of spontaneously formed interphases on high‐capacity metal anodes.

Zhao, Qing↗

Understanding the Role of Overpotentials in Lithium Ion Conversion Reactions: Visualizing the Interface

Oxide conversion reactions are known to have substantially higher specific capacities than intercalation materials used in Li-ion batteries, but universally suffer from large overpotentials associated with the formation of interfaces between the resulting nanoscale metal and Li 2 O products. Here we use the interfacial sensitivity of operando X-ray reflectivity to visualize the structural evolution of ultrathin NiO electrodes and their interfaces during conversion. We observe two additional reactions prior to the well-known bulk, three-dimensional conversion occurring at 0.6 V: an accumulation of lithium at the buried metal/oxide interface (at 2.2 V) followed by interfacial lithiation of the buried NiO/Ni interface at the theoretical potential for conversion (at 1.9 V). To understand the mechanisms for bulk and interfacial lithiation, we calculate interfacial energies using density functional theory to build a potential-dependent nucleation model for conversion. These calculations show that the additional space charge layer of lithium is a crucial component for reducing energy barriers for conversion in NiO.

25 ENERGY STORAGE↗

Safe and Private Forward-trading Platform for Transactive Microgrids

Power grids are evolving at an unprecedented pace due to the rapid growth of distributed energy resources (DER) in communities. These resources are very different from traditional power sources, as they are located closer to loads and thus can significantly reduce transmission losses and carbon emissions. However, their intermittent and variable nature often results in spikes in the overall demand on distribution system operators (DSO). To manage these challenges, there has been a surge of interest in building decentralized control schemes, where a pool of DERs combined with energy storage devices can exchange energy locally to smooth fluctuations in net demand. Building a decentralized market for transactive microgrids is challenging, because even though a decentralized system provides resilience, it also must satisfy requirements such as privacy, efficiency, safety, and security, which are often in conflict with each other. As such, existing implementations of decentralized markets often focus on resilience and safety but compromise on privacy. In this article, we describe our platform, called TRANSAX, which enables participants to trade in an energy futures market, which improves efficiency by finding feasible matches for energy trades, enabling DSOs to plan their energy needs better. TRANSAX provides privacy to participants by anonymizing their trading activity using a distributed mixing service, while also enforcing constraints that limit trading activity based on safety requirements, such as keeping planned energy flow below line capacity. We show that TRANSAX can satisfy the seemingly conflicting requirements of efficiency, safety, and privacy. We also provide an analysis of how much trading efficiency is lost. Trading efficiency is improved through the problem formulation, which accounts for temporal flexibility, and system efficiency is improved using a hybrid-solver architecture. Lastly, we describe a testbed to run experiments and demonstrate its performance using simulation results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Southeast Regional Clean Energy Policy Analysis (Revised)

More than half of the electricity produced in the southeastern states is fuelled by coal. Although the region produces some coal, most of the states depend heavily on coal imports. Many of the region's aging coal power facilities are planned for retirement within the next 20 years. However, estimates indicate that a 20% increase in capacity is needed over that time to meet the rapidly growing demand. The most common incentives for energy efficiency in the Southeast are loans and rebates; however, total public spending on energy efficiency is limited. The most common state-level policies to support renewable energy development are personal and corporate tax incentives and loans. The region produced 1.8% of the electricity from renewable resources other than conventional hydroelectricity in 2009, half of the national average. There is significant potential for development of a biomass market in the region, as well as use of local wind, solar, methane-to-energy, small hydro, and combined heat and power resources. Options are offered for expanding and strengthening state-level policies such as decoupling, integrated resource planning, building codes, net metering, and interconnection standards to support further clean energy development. Benefits would include energy security, job creation, insurance against price fluctuations, increased value of marginal lands, and local and global environmental paybacks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Semiconductor: Supply Chain Deep Dive Assessment

In February 2021, President Biden signed Executive Order (EO) 14017, “America’s Supply Chains,” directing seven executive agencies to evaluate the resilience and security of the nation’s critical supply chains and to craft strategies for six industrial bases that underpin America’s economic and national security. See Sec. 3(b) of E.O. 14017. As part of the one-year response to EO 14017, the U.S. Department of Energy (DOE), through the national laboratories, conducted evaluations of the supply chains that encompass the Energy Sector Industrial Base, with a particular focus on technologies required to decarbonize the U.S. by 2050. This report focuses on one of these technologies, semiconductors, both conventional and wide bandgap (WBG) power electronics (PE). As noted in the 100-Day report, conventional semiconductors are a keystone technology that are essential for the operation of nearly every electronic device, including those that are critical to decarbonization, such as electric vehicles (EVs), industrial and building applications, and electricity generation and end use. In addition, power electronics have been applied to industrial equipment to improve energy efficiency and enhance controllability. Power electronics have also been used to improve the reliability of data centers and critical infrastructure, including the stabilization of the electric grid while subjected to disturbances. Increasingly, power electronics are being used to integrate renewable energy and battery storage systems, enabling new grid services and the development of microgrids. It is estimated that 30% of the electricity used in the U.S. passes through power electronic devices, and studies suggest that this number could reach 80% as power electronics are deployed in more markets. Nearly all forms of electrified transportation will depend on power electronics. Power electronic systems utilize high-capacity semiconductor devices at their core. The continued growth in power electronics depends on sustained innovation in the semiconductor industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Residential Variable-Capacity Heat Pumps Sized to Heating Loads

Variable capacity heat pumps are an emerging technology offering significant energy savings potential and improved efficiency. With conventional single-speed systems, it is important to appropriately size heat pumps for the cooling load as over-sizing would result in cycling and insufficient latent capacity required for humidity control. These appropriately sized systems are often under-sized for the heating load and require inefficient supplemental electric resistance heat to meet the heating demand. Variable capacity heat pumps address these shortcomings by providing an opportunity to intentionally size systems for the dominant heating season load without adverse effects of cycling or insufficient dehumidification in the cooling season. This intentionally-sized system could result in significant energy savings in the heating season, as the need for inefficient supplemental electric resistance heat is drastically reduced. This is a continuation of a study evaluating the energy consumption of variable capacity heat pumps installed in two unoccupied research homes in Farragut, a suburb of Knoxville, Tennessee. In this particular study, space conditioning systems are intentionally sized for the heating season loads to provide an opportunity to understand and evaluate the impact this would have on electric resistance heat use and dehumidification. The results and conclusions drawn through this research are valid and specific for portions of the Southeastern and Midwestern United States falling in the mixed-humid climate zone. While other regions in the U.S. do not experience this type of climate, this work provides a basis for, and can help understand the implications of other climate zones on residential space conditioning energy consumption. The data presented here will provide a framework for fine tuning residential building EnergyPlus models that are being developed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Modelling and Performance Evaluation of a Chemisorption Heat Pump for Cold Climate

Space heating is a significant contributor to the energy consumption in residential buildings, especially in cold climates where electric-driven heat pumps lose the advantage of high efficiency and conventional gas-combustion furnaces have limited efficiency. Chemical adsorption (chemisorption) heat pumps (CSHP) have the potential for producing heating with high energy efficiency under cold operating conditions. A CSHP operates intermittently between desorption and adsorption modes, and their performance is affected by system design and transient system control. This study developed a dynamic model and used it to evaluate the daily system performance under different designs and controls, particularly the buffer tank size and the controlled minimum heating power. The simulation results revealed the effects of these parameters on the system performance and helped identify the optimal design and control for the highest coefficient of performance and heating capacity.

Yang, Zhiyao↗

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗

Neutron Imaging of Al6061 Prepared by Solid-State Friction Stir Additive Manufacturing

Solid-state Friction Stir Additive Manufacturing has recently gained attention as a result of its capacity to fabricate large-scale parts while preserving the mechanical properties of the feedstock material. However, the correlation between the quality of layer-by-layer bonding of the deposited metal and processing parameters has remained unknown. Neutron imaging techniques, with 90% total transmission per cm, are employed for Al6061 parts fabricated by MELD ® Technology as a non-destructive evaluation approach for the first time to investigate the layer-by-layer structure of a stadium-shaped ingot in different sections. The post-processed results show the fabricated parts with an optimized set of processing parameters are void-free. However, the hydrocarbon-based feedstock lubricant segregates between the layers, which consequently may lead to non-uniform weaker mechanical properties along the build direction and stimulate crack initiation during mechanical loading. The tensile test results show 14% lower strain-to-failure values in alleged contaminated areas in transmission imaging results. Additionally, layer bonding is significantly impacted by hot-on-hot and hot-on-cold layer deposition schemes, especially for larger layer thicknesses.

36 MATERIALS SCIENCE↗

Review of the potential and challenges of MOF-based adsorption heat pumps for sustainable cooling and heating in the buildings

Heat pumps are regarded as the most suitable means to meet the future demand of heating and cooling in the building, as they require small input of electrical energy and output high thermal energy. Vapor compression heat pump (VCHP) and transcritical-CO 2 heat pump are the two major heat pump technologies currently dominating the market. However, VCHP system suffers from its fugitive emission of hydrofluorocarbon (HFC) refrigerants, and transcritical-CO 2 system requires high operating pressure (typically 9–13 MPa). For low-to-medium temperature heating and cooling applications thermally driven adsorption heat pump (AHP) provides a better alternative to VCHP and transcritical-CO 2 system as AHP uses natural refrigerants and operates at a much lower pressure. But currently available AHP technology has the limitation of low coefficient of performance (COP). Advances in synthesizing metal-organic frameworks (MOF) with high gas adsorption capacity have created an opportunity to address the problem of low COP of current AHP technology. Here, this article reviews the progress made in the past decade in utilizing MOF and conventional adsorbents with different working fluids in AHP technology and compares their performance. The article also summarizes the key challenges for the MOF-based AHP technology and provides the authors’ perspective to address these challenges.

30 DIRECT ENERGY CONVERSION↗

Exploring Wildfire & Energy data toward State Prioritization Index (WESPI)

Energy infrastructure can both induce and suffer risks from wildfires ranging from direct damage to energy assets such as substations and power lines to Public Safety Power Shutoffs. Recent wildfire events underscore the need for data-driven approaches that help states and utilities proactively plan for wildfire risk. Existing national tools such as Federal Emergency Management Agency (FEMA)’s National Risk Index (NRI) are valuable for community hazard planning. However, they are less suited for energy infrastructure, as they emphasize population and building exposure rather than system vulnerabilities. In this paper, we explore relationships between energy and wildfire data and present a Wildfire-Energy State Prioritization Index (WESPI). Our methodology combines data from the US Forest Service’s Fire Simulation (FSIM) dataset with energy resilience metrics, historical fire incidents, and geospatial data on transmission lines and fire stations. Correlation analyses suggest that FSIM burn probability is more strongly associated with power outage metrics (ρ = 0.32) than NRI wildfire frequency, and counties with a greater density of fire stations experience more frequent, but less intense wildfires. We further leverage data for burn probability, transmission line density, and fire station density to develop a Wildfire-Energy State Prioritization Index (WESPI) to highlight counties where wildfire hazard, infrastructure exposure, and limited suppression capacity converge. The index provides a consistent, scalable framework for state energy offices and utilities to screen counties for vegetation management, optimization of outage management system deployment, and to inform wildfire mitigation plans.

Critical infrastructure↗

New Mexico: New Mexico's Clean Energy Resources and Economy [Brochure]

New Mexico is poised to become a leader in clean energy production, thanks to its exceptional renewable resources—particularly the solar energy potential of its southern deserts. From 2010 to 2011, New Mexico’s solar photovoltaic capacity nearly tripled from 43 megawatts (MW) to 116 MW, placing New Mexico fourth in the nation. Concentrated solar thermal generation plants have the potential to further develop this resource. Geothermal activity in the northern Rocky Mountain areas has significant energy production potential; there are also pockets of strong wind resources across the state. New Mexico’s state energy policies and utility incentive programs aim to take full advantage of these resources. In 2012, 4.4% of electricity in New Mexico was generated from renewable resources. New Mexico’s Renewable Portfolio Standard requires that this rate increase to 20% by 2020 for investor-owned utilities and 10% for cooperatives. In addition to its Renewable Portfolio Standard, personal and corporate tax credits are available for alternative energy production and efficient building development. To encourage conservation, New Mexico has also adopted an energy efficiency standard. Its goal is to reduce energy consumption relative to 2005 levels—5% by 2014 and 10% by 2020. New Mexico also boasts several utility rebate programs for energy efficient appliance purchases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Akutan Geothermal: Resource Report

Geothermal energy resources are present in the Hot Springs Bay Valley geothermal area, and the City has invested considerable money and time in the exploration of the resource for future use. Exploration activities funded primarily through a grant the City was awarded from Alaska Energy Authority and later supplemented by the U. S. Department of Energy (DOE), with cost share from the City. The exploration led to the development of a geothermal resource conceptual model that was built and refined between 2008 and 2018. During this period, geological and geophysical studies, exploration drilling and other activities were completed, including a preliminary feasibility study for a power project, investigations of the terrain for suitability for access and development, environmental and archeological review, plus TG well abandonment and a review of economic considerations. The model of the resource predicts that there is a viable geothermal resource in two general areas: on the northwest edge of Hot Springs Bay Valley going northwest of the valley (hot springs area) and southwest of the Valley (fumarole area). The resource temperature for the valley area is expected to be about 170°C (340°F) and given the size and permeability estimates (with a factor for the level of confidence in the estimates), the mean power capacity of the outflow resource is 3 MWe and the P50 (most likely) power capacity is 1 MWe. The fumarole area has an expected resource temperature of 240°C (464°F) and given the size and permeability estimates mean capacity is 20 MWe and the P50 (most likely) capacity is 9 MWe. Permeability is the most difficult factor to predict and has a significant impact on the available geothermal fluids and therefore the amount of power that can be generated. The uncertainty in this value is the main reason for lower confidence in the likelihood of exploration success and the wide range in predicted MW values. The permeability has been difficult to locate as indicated by the results of the flow test at AK-3 in 2017. The test resulted in the production of some fluid, but due to low permeability, the recharge to the wellbore was too slow to sustain flow. The greatest probability of overall MWe production is in the fumarole region, but development is hampered by poor accessibility. The extremely high cost of road building for exploratory drilling, put an end to planning at an intermediate stage of the project and refocused attention on the viability of development in the hot spring outflow part of the resource. The City will be determining what the next steps are with AK-3, which is still that is still open and maintained in a suspended status in HSBV. While AK-3 remains accessible (not plugged with cement) it will need to be maintained. The City has a bond with AOGCC that will remain in place until the well is abandoned. GRG recommends that the well be maintained open as an asset for the foreseeable future.

15 GEOTHERMAL ENERGY↗

HEP Science Network Requirements--Final Report

The Energy Sciences Network (ESnet) is the primary provider of network connectivity for the US Department of Energy Office of Science, the single largest supporter of basic research in the physical sciences in the United States. In support of the Office of Science programs, ESnet regularly updates and refreshes its understanding of the networking requirements of the instruments, facilities, scientists, and science programs that it serves. This focus has helped ESnet to be a highly successful enabler of scientific discovery for over 20 years. In August 2009 ESnet and the Office of High Energy Physics (HEP), of the DOE Office of Science, organized a workshop to characterize the networking requirements of the programs funded by HEP. The International HEP community has been a leader in data intensive science from the beginning. HEP data sets have historically been the largest of all scientific data sets, and the communty of interest the most distributed. The HEP community was also the first to embrace Grid technologies. The requirements identified at the workshop are summarized below, and described in more detail in the case studies and the Findings section: (1) There will be more LHC Tier-3 sites than orginally thought, and likely more Tier-2 to Tier-2 traffic than was envisioned. It it not yet known what the impact of this will be on ESnet, but we will need to keep an eye on this traffic. (2) The LHC Tier-1 sites (BNL and FNAL) predict the need for 40-50 Gbps of data movement capacity in 2-5 years, and 100-200 Gbps in 5-10 years for HEP program related traffic. Other key HEP sites include LHC Tier-2 and Tier-3 sites, many of which are located at universities. To support the LHC, ESnet must continue its collaborations with university and international networks. (3) While in all cases the deployed 'raw' network bandwidth must exceed the user requirements in order to meet the data transfer and reliability requirements, network engineering for trans-Atlantic connectivity is more complex than network engineering for intra-US connectivity. This is because transoceanic circuits have lower reliability and longer repair times when compared with land-based circuits. Therefore, trans-Atlantic connectivity requires greater deployed bandwidth and diversity to ensure reliability and service continuity of the user-level required data transfer rates. (4) Trans-Atlantic traffic load and patterns must be monitored, and projections adjusted if necessary. There is currently a shutdown planned for the LHC in 2012 that may affect projections of trans-Atlantic bandwidth requirements. (5) There is a significant need for network tuning and troubleshooting during the establishment of new LHC Tier-2 and Tier-3 facilities. ESnet will work with the HEP community to help new sites effectively use the network. (6) SLAC is building the CCD camera for the LSST. This project will require significant bandwidth (up to 30Gbps) to NCSA over the next few years. (7) The accelerator modeling program at SLAC could require the movement of 1PB simulation data sets from the Leadership Computing Facilities at Argonne and Oak Ridge to SLAC. The data sets would need to be moved overnight, and moving 1PB in eight hours requires more than 300Gbps of throughput. This requirement is dependent on the deployment of analysis capabilities at SLAC, and is about five years away. (8) It is difficult to achieve high data transfer throughput to sites in China. Projects that need to transfer data in or out of China are encouraged to deploy test and measurement infrastructure (e.g. perfSONAR) and allow time for performance tuning.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Building interface bonding and shield for stable Li-rich Mn-based oxide cathode

Implementation of Li-rich Mn-based oxide cathode with high-energy-density has been restrained by capacity/voltage degradation that results from irreversible lattice oxygen loss and structure rearrangements. To resolve these challenges, in this work, Li 1.2 Mn 0.54 Ni 0.13 Co 0.13 O 2 encapsulated by amorphous Co x B (CB-LRM) is rationally designed via autocatalytic plating for highly reversible cationic/anionic hybrid cathode material. Band coherency is ingeniously evoked by interface-reconstruction between bulk structure and amorphous coating layer, which lower the energy of O $2p$ states. Furthermore, this is associated with strengthened orbital hybridization of O $2p$-Mn $3d$ and increased formation energy of oxygen vacancy, which mitigates the lattice oxygen loss considerably. Additionally, interface shielding effects that protect electrode against electrolyte corrosion and the reduction of surface oxygen are also present with fully coverage of amorphous Co x B coating layer. As a result, the as-designed CBLRM cathode exhibits excellent cycle stability after 100 loops with only 0.154% per cycle capacity fade and improved voltage degradation. Given this, this work provides a potential avenue for rational design of lattice oxygen-based electrode materials with high-energy-density.

25 ENERGY STORAGE↗

A Total Cost of Ownership Model for Low Temperature PEM Fuel Cells in Combined Heat and Power and Backup Power Applications

A total cost of ownership model is described for low temperature proton exchange membrane stationary fuel cell systems for combined heat and power (CHP) applications from 1-250kW and backup power applications from 1-50kW. System designs and functional specifications for these two applications were developed across the range of system power levels. Bottom-up cost estimates were made for balance of plant costs, and detailed direct cost estimates for key fuel cell stack components were derived using design-for-manufacturing-and-assembly techniques. The development of high throughput, automated processes achieving high yield are projected to reduce the cost for fuel cell stacks to the $300/kW level at an annual production volume of 100 MW. Several promising combinations of building types and geographical location in the U.S. were identified for installation of fuel cell CHP systems based on the LBNL modelling tool DER CAM. Life-cycle modelling and externality assessment were done for hotels and hospitals. Reduced electricity demand charges, heating credits and carbon credits can reduce the effective cost of electricity ($/kWhe) by 26-44percent in locations such as Minneapolis, where high carbon intensity electricity from the grid is displaces by a fuel cell system operating on reformate fuel. This project extends the scope of existing cost studies to include externalities and ancillary financial benefits and thus provides a more comprehensive picture of fuel cell system benefits, consistent with a policy and incentive environment that increasingly values these ancillary benefits. The project provides a critical, new modelling capacity and should aid a broad range of policy makers in assessing the integrated costs and benefits of fuel cell systems versus other distributed generation technologies.

08 HYDROGEN↗