Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Lattice QCD Constraints on the Fourth Mellin Moment of the Pion Light Cone Distribution Amplitude using the HOPE method

The light-cone distribution amplitude (LCDA) of the pion contains information about the parton momentum carried by the quarks and is an important theoretical input for various predictions of exclusive processes at high energy, including the pion electromagnetic form factor. Progress towards constraining the fourth Mellin moment of the LCDA using the heavy-quark operator product expansion (HOPE) method is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE LOSS-CONE PROBLEM IN AXISYMMETRIC NUCLEI

We consider the problem of consumption of stars by a supermassive black hole (SBH) at the center of an axisymmetric galaxy. Inside the SBH sphere of influence, motion of stars in the mean field is regular and can be described analytically in terms of three integrals of motion: the energy E, the z-component of angular momentum L{sub z} , and the secular Hamiltonian H. There exist two classes of orbits, tubes and saucers; saucers occupy the low-angular-momentum parts of phase space and their fraction is proportional to the degree of flattening of the nucleus. Perturbations due to gravitational encounters lead to diffusion of stars in integral space, which can be described using the Fokker-Planck equation. We calculate the diffusion coefficients and solve this equation in the two-dimensional phase space (L{sub z} , H), for various values of the capture radius and the degree of flattening. Capture rates are found to be modestly higher than in the spherical case, up to a factor of a few, and most captures take place from saucer orbits. We also carry out a set of collisional N-body simulations to confirm the predictions of the Fokker-Planck models. We discuss the implications of our results for rates of tidal disruption and capture in the Milky Way and external galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Light cones in relativity: Real, complex, and virtual, with applications

We study geometric structures associated with shear-free null geodesic congruences in Minkowski space-time and asymptotically shear-free null geodesic congruences in asymptotically flat space-times. We show how in both the flat and asymptotically flat settings, complexified future null infinity I{sub C}{sup +} acts as a ''holographic screen,'' interpolating between two dual descriptions of the null geodesic congruence. One description constructs a complex null geodesic congruence in a complex space-time whose source is a complex worldline, a virtual source as viewed from the holographic screen. This complex null geodesic congruence intersects the real asymptotic boundary when its source lies on a particular open-string type structure in the complex space-time. The other description constructs a real, twisting, shear-free or asymptotically shear-free null geodesic congruence in the real space-time, whose source (at least in Minkowski space) is in general a closed-string structure: the caustic set of the congruence. Finally we show that virtually all of the interior space-time physical quantities that are identified at null infinity I{sup +} (center of mass, spin, angular momentum, linear momentum, and force) are given kinematic meaning and dynamical descriptions in terms of the complex worldline.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advancing the Frontiers of Deep Learning for Low-Dose 3D Cone-Beam CT Reconstruction

X-ray computed tomography (CT) is an important noninvasive medical imaging modality for studying the structural details of internal organs. Image reconstruction in CT is an inverse problem of recovering an object's internal structure from the absorption profile of X-ray beams (sinogram) measured using a detector. The classical variational approach for CT reconstruction minimizes an energy functional using an appropriate iterative algorithm. Motivated by the success of deep learning (DL), researchers have begun to leverage training data and enhanced computing capabilities in recent years to produce high-fidelity reconstructed images. Nonetheless, much of the academic research in DL algorithms for CT has focused primarily on the two-dimensional setting (with simplified forward operators and noise model) for proofs-of-concept, and a comprehensive benchmarking of various classical and data-driven CT reconstruction approaches has not beenundertaken. The key objective of our CT reconstruction grand challenge was to promote methodological advancements for both classical and DL-based approaches for clinical CT with a reasonably accurately simulated 3D CT forward operator and noise model. We have utilized the publicly available LIDC-IDRI dataset and simulated sinograms and FDK images corresponding to two dose levels (clinical- and low-dose, constituting two tracks of the challenge) starting from the normal-dose images as the ground truth. In this paper, we summarize the motivation, context, and results of our challenge, and highlight the future research directions in DL for clinical CT.

X-ray tomography↗

Effects of Mass Addition on the Stability of Slender Cones at Hypersonic Speeds

The effect of mass addition on the flow over bodies moving at hypersonic speeds has been studied by several investigators (e.g., Cresci and Libby). In most of this work, primary attention logically has been directed toward the effects of foreign-gas injection on heat transfer and pressure distributions, and, principally for this reason, most of the work ha been done at zero angle of attack. The foreign gas can be provided either by some active injection system or by the action of an ablation heat shield. With increasing rates of injection, the basic flow about the body can be affected significantly. One such effect was observed in the paper by Cresci and Libby, where it was shown that the shockwave standoff distance can be increased by gas injection at the nose of a body.

SLENDER BODY↗

Massive Degeneracy and Goldstone Bosons: A Challenge for the Light Cone

Wherein it is argued that the light front formalism has problems dealing with Goldstone symmetries. It is further argued that the notion that in hadron condensates can explain Goldstone phenomena is false. This talk can be summarized as follows: (1) Exact symmetries can be realized in Wigner or Goldstone mode. (2) When a symmetry is realized in Wigner mode the states of the theory form degenerate irreducible representations of the symmetry group and the lowest energy state is unique. (3) When a symmetry is realized in Goldstone mode the lowest energy state of the theory is infinitely degenerate, the states of the theory do not form irreducible representations of the symmetry group and there are massless particles coupled by the conserved currents to any one of the possible ground states. (4) In finite volume the signal of a Goldstone realization of a symmetry is that the number of nearly degenerate states grows rapidly with increasing volume and the gap between these states shrinks exponentially with the volume. (5) The existence of a condensate such as the magnetization, for a ferromagnet, or the staggered magnetization for an anti-ferromagnet, signals a Goldstone symmetry. This is because this condensate transforms non-trivially under the symmetry transformations and so its existence implies the ground state isn't unique. (6) PCAC means that the pion, kaon and eta are would be Goldstone bosons of the theory where the quark masses are set to zero. This interpretation is overwhelmingly supported by experimental data. This means that these particles are really the wiggling of the order parameter or condensate. (7) Finally, in order for the Goldstone particle to exist there has to be something to wiggle every place where the particle can exist. This means that the condensate that is the order parameter for this Goldstone symmetry cannot be confined to the interior of hadrons. Thus, to reiterate, the challenge for the Light Front is to show how the formalism gives rise to this sort of pattern of degeneracy when the physical volume of space becomes large.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Use of C-Arm Cone Beam CT During Hepatic Radioembolization: Protocol Optimization for Extrahepatic Shunting and Parenchymal Enhancement

PurposeTo optimize a C-arm computed tomography (CT) protocol for radioembolization (RE), specifically for extrahepatic shunting and parenchymal enhancement.Materials and MethodsA prospective development study was performed per IDEAL recommendations. A literature-based protocol was applied in patients with unresectable and chemorefractory liver malignancies undergoing an angiography before radioembolization. Contrast and scan settings were adjusted stepwise and repeatedly reviewed in a consensus meeting. Afterwards, two independent raters analyzed all scans. A third rater evaluated the SPECT/CT scans as a reference standard for extrahepatic shunting and lack of target segment perfusion.ResultsFifty scans were obtained in 29 procedures. The first protocol, using a 6 s delay and 10 s scan, showed insufficient parenchymal enhancement. In the second protocol, the delay was determined by timing parenchymal enhancement on DSA power injection (median 8 s, range 4–10 s): enhancement improved, but breathing artifacts increased (from 0 to 27 %). Since the third protocol with a 5 s scan decremented subjective image quality, the second protocol was deemed optimal. Median CNR (range) was 1.7 (0.6–3.2), 2.2 (−1.4–4.0), and 2.1 (−0.3–3.0) for protocol 1, 2, and 3 (p = 0.80). Delineation of perfused segments was possible in 57, 73, and 44 % of scans (p = 0.13). In all C-arm CTs combined, the negative predictive value was 95 % for extrahepatic shunting and 83 % for lack of target segment perfusion.ConclusionAn optimized C-arm CT protocol was developed that can be used to detect extrahepatic shunts and non-perfusion of target segments during RE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗