Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPACTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

A compact multipurpose nanomanipulator for use inside a scanning electron microscope

A compact, two-stage nanomanipulator was designed and built for use inside a scanning electron microscope. It consists of a fine stage employing piezostacks that provide a 15 {mu}m range in three dimensions and a coarse stage based on commercially available stick-slip motors. Besides the fabrication of enhanced probes for scanning probe microscopy and the enhancement of electron field emitters, other novel manipulation processes were developed, such as locating, picking up, and positioning small nanostructures with an accuracy of {approx}10 nm. In combination with in situ I-V experiments, welding, and etching, this results in a multipurpose nanofactory, enabling a new range of experiments.

36 MATERIALS SCIENCE↗

The compact electron cyclotron resonance ion source KeiGM for the carbon ion therapy facility at Gunma University

A high-energy carbon-ion radiotherapy facility is under construction at Gunma University Heavy Ion Medical Centre (GHMC). Its design was based on a study of the heavy ion radiotherapy at the National Institute of Radiological Sciences (NIRS) in order to reduce the size and construction cost of the facility. A compact electron cyclotron resonance ion source (ECRIS) for Gunma University, called KeiGM, was installed in 2008. It is almost a copy of the prototype ECRIS Kei2 which was developed by NIRS; meanwhile this prototype produced over 1 e mA of C{sup 4+} using C{sub 2}H{sub 2} gas (660 W and 40 kV). The beam intensity of C{sup 4+} was 600 e {mu}A with CH{sub 4} gas (250 W and 30 kV). The beam intensity satisfies the required value of 300 e {mu}A.

43 PARTICLE ACCELERATORS↗

A compact and continuously driven supersonic plasma and neutral source

A compact and repetitively driven plasma source has been developed by utilizing a magnetized coaxial plasma gun (MCPG) for diagnostics requiring deep penetration of a large amount of neutral flux. The system consists of a MCPG 95mm in length with a DN16 ConFlat connection port and an insulated gate bipolar transistor (IGBT) inverter power unit. The power supply consists of an array of eight IGBT units and is able to switch the discharge on and off at up to 10 kV and 600 A with a maximum repetitive frequency of 10 kHz. Multiple short duration discharge pulses maximize acceleration efficiency of the plasmoid. In the case of a 10 kHz operating frequency, helium-plasmoids in the velocity range of 20 km/s can be achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A compact streak camera for 150 fs time resolved measurement of bright pulses in ultrafast electron diffraction

We have developed a compact streak camera suitable for measuring the duration of highly charged subrelativistic femtosecond electron bunches with an energy bandwidth in the order of 0.1%, as frequently used in ultrafast electron diffraction (UED) experiments for the investigation of ultrafast structural dynamics. The device operates in accumulation mode with 50 fs shot-to-shot timing jitter, and at a 30 keV electron energy, the full width at half maximum temporal resolution is 150 fs. Measured durations of pulses from our UED gun agree well with the predictions from the detailed charged particle trajectory simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a digital data acquisition system and optimization of n-{gamma} discrimination for a compact neutron spectrometer

A compact NE213 liquid scintillation neutron spectrometer with a new digital data acquisition (DAQ) system is now in operation at the Physikalisch-Technische Bundesanstalt (PTB). With the DAQ system, developed by ENEA Frascati, neutron spectrometry with high count rates in the order of 5x10{sup 5} s{sup -1} is possible, roughly an order of magnitude higher than with an analog acquisition system. To validate the DAQ system, a new data analysis code was developed and tests were done using measurements with 14-MeV neutrons made at the PTB accelerator. Additional analysis was carried out to optimize the two-gate method used for neutron and gamma (n-{gamma}) discrimination. The best results were obtained with gates of 35 ns and 80 ns. This indicates that the fast and medium decay time components of the NE213 light emission are the ones that are relevant for n-{gamma} discrimination with the digital acquisition system. This differs from what is normally implemented in the analog pulse shape discrimination modules, namely, the fast and long decay emissions of the scintillating light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact stellar objects under the influence of strong magnetic fields

In the present work we study the properties of compact objects under the influence of strong magnetic fields. We consider a gas of nucleons, electrons and muons with beta equilibrium under the influence of different values of magnetic fields, with and without anomalous magnetic moment. Equations of state and mass-radius relations are calculated for different values of the magnetic fields.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Perveance and ion bunch structure from a 'compact, high-pressure' laser ion source

The Dublin City University (DCU) laser ion source (LIS) is a 'compact high-pressure' laser ion source utilizing a table top Q-switched laser. The DCU-LIS combines high laser fluence (F>4 kJ cm{sup -2}), high laser intensity (I>10{sup 11} W cm{sup -2}) with a short field free region (L=48 mm) and high source potential (V{sub ext}>40 kV) in order to offset recombination losses within the plasma and maximize the proportion of highly charged ions which are extracted from the plasma plume. Such a configuration also provides high peak currents (I{sub p}>3 mA), high current densities (J>5 mA cm{sup -2}), and high charge states (Cu{sup 6+}) in the extracted ion-bunch train. However, to obtain and utilize these parameter values in a high pressure LIS requires characterization and control of a number of processes related to ion dynamics and space charge effects on the extracted ions at the plasma plume-anode-extraction gap interface. Relevant issues include electric field distortion, Debye shielding, beam divergence, overfocusing, and perveance (P) in addition to current density profiles for the extracted ion beam. In this paper we focus on these issues and their impact on charge particle extraction and acceleration with a view to elucidating the parameter regimes within which the DCU-LIS performance envelope is optimal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Compact Ion Source with a Hot Hollow Cathode

A compact ion source with 14 mm diameter, 30 mm long discharge region was developed. A total size of the ion source including the beam extraction system was 60 mm in diameter and 160 mm in length. A high temperature coaxial cathode consisting of thin-wall tantalum and tungsten tubes produced a discharge plasma. A source gas was supplied through the inner W tube of the coaxial cathode. A stable plasma of H{sub 2} was maintained with the discharge current of 2.0 A at 68 A cathode heating current. The optimum H{sub 2} gas pressure for ion beam extraction was 2x10{sup -2} Pa. Hydrogen ion beam current was 120 {mu}A (1 mA/cm{sup 2}) at 2.0 A discharge current and 3.0 kV extraction voltage.

43 PARTICLE ACCELERATORS↗

Compact formulas for guiding-center orbits in axisymmetric tokamak geometry

Compact formulas for trapped-particle and passing-particle guiding-center orbits in axisymmetric tokamak geometry are given in terms of the Jacobi elliptic functions and complete elliptic integrals. These formulas can find applications in bounce-center kinetic theory as well as guiding-center Fokker-Planck kinetic theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulations of stable compact proton beam acceleration from a two-ion-species ultrathin foil

We report stable laser-driven proton beam acceleration from ultrathin foils consisting of two ion species: heavier carbon ions and lighter protons. Multidimensional particle-in-cell simulations show that the radiation pressure leads to very fast and complete spatial separation of the species. The laser pulse does not penetrate the carbon ion layer, avoiding the proton Rayleigh-Taylor (RT)-like instability. Ultimately, the carbon ions are heated and spread extensively in space. In contrast, protons always ride on the front of the carbon ion cloud, forming a compact high quality bunch. We introduce a simple three-interface model to interpret the instability suppression in the proton layer. The model is backed by simulations of various compound foils such as carbon-deuterium and carbon-tritium foils. The effects of the carbon ions' charge state on proton acceleration are also investigated. It is shown that with the decrease of the carbon ion charge state, both the RT-like instability and the Coulomb explosion degrade the energy spectrum of the protons. Finally, full 3D simulations are performed to demonstrate the robustness of the stable two-ion-species regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel compact design of calibration equipment for gas and thermal sensors

A novel design of calibration equipment has been developed for static and dynamic calibrations of gas and thermal sensors. This system is cheap, compact, and easily adjustable, which is also combined with a plasma surface modification source for tailoring the surface of sensors to ensure the sensitivity and selectivity. The main advantage of this equipment is that the operating temperature, bias voltage, types of plasma source (for surface modification), types of feeding gases, and gas flow rate (for calibrations), etc., can be independently controlled. This novel system provides a highly reliable, reproducible, and economical method of calibrations for various gas and thermal sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact Electronic Gamma Source For Radiotherapy

A compact mono-energetic gamma source is being developed to replace the radiological sources used in radiotherapy and other medical instruments. The electronic gamma source utilizes low-energy nuclear reactions to generate gammas in the 0.5 to 1.0 MeV energy range. Independent control of the ion current and energy is achieved by decoupling the RF-driven ion source and pyroelectric crystal-based acceleration systems The ions are accelerated to voltages above 100 keV and bombard a reaction target to produce gammas. Thermal management of the pyroelectric crystal-based accelerator is achieved by convective dielectric fluid flow around the crystal. This approach provides better temperature uniformity in the crystal and higher dielectric strength for suppressing voltage breakdown and enabling faster thermal cycling rates.

43 PARTICLE ACCELERATORS↗

A Permanent-Magnet Microwave Ion Source For A Compact High-Yield Neutron Generator

We present recent work on the development of a microwave ion source that will be used in a high-yield compact neutron generator for active interrogation applications. The sealed tube generator will be capable of producing high neutron yields, 5x10{sup 11} n/s for D-T and {approx}1x10{sup 10} n/s for D-D reactions, while remaining transportable. We constructed a microwave ion source (2.45 GHz) with permanent magnets to provide the magnetic field strength of 87.5 mT necessary for satisfying the electron cyclotron resonance (ECR) condition. Microwave ion sources can produce high extracted beam currents at the low gas pressures required for sealed tube operation and at lower power levels than previously used RF-driven ion sources. A 100 mA deuterium/tritium beam will be extracted through a large slit (60x6 mm{sup 2}) to spread the beam power over a larger target area. This paper describes the design of the permanent-magnet microwave ion source and discusses the impact of the magnetic field design on the source performance. The required equivalent proton beam current density of 40 mA/cm{sup 2} was extracted at a moderate microwave power of 400 W with an optimized magnetic field.

43 PARTICLE ACCELERATORS↗

A compact electron cyclotron resonance proton source for the Paul Scherrer Institute's proton accelerator facility

A compact electron cyclotron resonance proton source has been developed and installed recently at thePaul Scherrer Institute's high intensity proton accelerator. Operation at the ion source test stand and the accelerator demonstrates a high reliability and stability of the new source. When operated at a 10 - 12 mA net proton current the lifetime of the source exceeds 2000 h. The essential development steps towards the observed performance are described.

43 PARTICLE ACCELERATORS↗

A compact digital time differential perturbed angular correlation-spectrometer using field programmable gate arrays and various timestamp algorithms

A user-friendly fully digital time differential perturbed angular correlation (TDPAC)-spectrometer with six detectors and fast digitizers using field programmable gate arrays (FPGA) is described and performance data are given. The new spectrometer has an online data analysis feature, a compact size, and a time resolution such as conventional analog spectrometers. Its calculation intensive part was implemented inside the digitizer. This gives the possibility to change parameters (energy windows, constant fraction trigger delay) and see their influence immediately in the {gamma}-{gamma} correlation diagrams. Tests were performed which showed that the time resolution using a {sup 60}Co source with energy window set at 1.17 MeV and 1.33 MeV is 265 ps with LaBr{sub 3}(Ce) scintillators and 254 ps with BaF{sub 2} scintillators. A true constant fraction algorithm turned out to be slightly better than the constant fraction of amplitude method. The spectrometer performance was tested with a TDPAC measurement using a {sup 44}Ti in rutile source and a positron lifetime measurement using {sup 22}Na. The maximum possible data rate of the spectrometer is 1.1 x 10{sup 6} {gamma} quanta per detector and second.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Compact Penning Ion Source for Material Studies

Development of ion sources of various sizes has been carried out since a long back. Gaseous ions of different nature are being used in different field of research as well as industrial applications like surface modification, doping, surface etching, sputtering, production of nano size particles and focused ion beam etc. Out of various geometry and operation regime, due to compactness, ruggedness and long life, penning type ion sources are widely used in different field of research and applications. One such type of ion source was developed in our laboratory. Though this source was meant for neutron generation, using deuterium ions, the effectiveness for other purposes was investigated. The discharge characteristic was studied for different gases like, Deuterium, Helium, Nitrogen, Oxygen and Argon. The source being a self extracted type; the extracted ion current from the extraction aperture was measured using one faraday cup. In this paper we have discussed, the discharge characteristic and the extraction ion current for different type of gases.

07 ISOTOPE AND RADIATION SOURCES↗

Electron Strippers for Compact Neutron Generators

The next generation of compact tandem-type DD or DT neutron generators requires a robust electron stripper with high charge exchange efficiency. In this study, stripping foils of various types were tested, and the H{sup -} to H{sup +} conversion efficiency, endurance to the heat load, and durability were investigated in terms of suitability in the tandem-type neutron generator. In the experiments, a H{sup -} beam was accelerated to about 180 keV, passes through a stripping foil, and produces a mixed beam of H{sup -}, H{sup 0}, and H{sup +}. These ions were separated by an electric field, and detected by a movable Faraday cup to determine the conversion efficiency. The experimental results using thin foils of diamond-like carbon, gold, and carbon nano-tubes revealed issues on the robustness. As a new concept, a H{sup -} beam was injected onto a metal surface with an oblique angle, and reflected H{sup +} ions are detected. It was found that the conversion efficiency, H{sup +} fraction in the reflected particles, depends on the surface condition, with the maximum value of about 90%.

43 PARTICLE ACCELERATORS↗

Plasma-enhanced gasification of low-grade coals for compact power plants

A high temperature of a steam torch ensures an efficient gasification of low-grade coals, which is comparable to that of high-grade coals. Therefore, the coal gasification system energized by microwaves can serve as a moderately sized power plant due to its compact and lightweight design. This plasma power plant of low-grade coals would be useful in rural or sparsely populated areas without access to a national power grid.

20 FOSSIL-FUELED POWER PLANTS↗