Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beam Optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Effects of radiation damage on the silicon lattice

Silicon was irradiated with both proton and electron particle beams in order to investigate changes in the structural and optical properties of the lattice as a result of the radiation damage. Lattice expansions occurred when large strain fields (+0.34 percent) developed after 1- and 3-MeV proton bombardment. The strain was a factor of three less after 1-MeV electron irradiation. Average increases of approximately 22 meV in the 3.46-eV interband energy gap and 14 meV in the Lorentz broadening parameter were measured after the electron irradiation.

Dumas, Katherine A.↗

Optical fiber sensors and signal processing for intelligent structure monitoring

Few mode optical fibers have been shown to produce predictable interference patterns when placed under strain. The use is described of a modal domain sensor in a vibration control experiment. An optical fiber is bonded along the length of a flexible beam. Output from the modal domain sensor is used to suppress vibrations induced in the beam. A distributed effect model for the modal domain sensor is developed. This model is combined with the beam and actuator dynamics to produce a system suitable for control design. Computer simulations predict open and closed loop dynamic responses. An experimental apparatus is described and experimental results are presented.

Thomas, Daniel↗

Gyrotron development for space power beaming

The use of a gyrotron for space power beaming, especially in the form of a lunar orbiting power station is discussed. The advantages of phased array power beaming, output power, and the design of a quasi-optical gyrotron are discussed.

Manheimer, Wallace M.↗

Feasibility of non-intrusive optical diagnostic measurements in hypersonic boundary layers for flight experiments

The present investigation of possible methods for nonintrusive optical diagnostics of hypersonic vehicle boundary layers notes electron-beam fluorescence to be capable of obtaining measurements of density, temperature, and shock-front location, as well as of N2, O2, and NO concentrations. NO will be a key indicator of vehicle nose and leading edge chemistry. It is expected that laser-induced fluorescence will allow measurements of NO and O2 concentrations when compact and reliable UV lasers become available; the sensors and instrumentation for spectral resolution of fluorescence along a line emanating from the vehicle and passing through the shock front already exist.

Cattolica, R. J.↗

Multi Spectral Imaging System

An optical imaging system provides automatic co-registration of a plurality of multi spectral images of an object which are generated by a plurality of video cameras or other optical detectors. The imaging system includes a modular assembly of beam splitters, lens tubes, camera lenses and wavelength selective filters which facilitate easy reconfiguration and adjustment of the system for various applications. A primary lens assembly generates a real image of an object to be imaged on a reticle which is positioned at a fixed length from a beam splitter assembly. The beam splitter assembly separates a collimated image beam received from the reticle into multiple image beams, each of which is projected onto a corresponding one of a plurality of video cameras. The lens tubes which connect the beam splitter assembly to the cameras are adjustable in length to provide automatic co-registration of the images generated by each camera.

Spiering, Bruce A.↗

Membrane Vibration Analysis Above the Nyquist Limit with Fluorescence Videogrammetry

A new method for generating photogrammetric targets by projecting an array of laser beams onto a membrane doped with fluorescent laser dye has recently been developed. In this paper we review this new fluorescence based technique, then proceed to show how it can be used for dynamic measurements, and how a short pulsed (10 ns) laser allows the measurement of vibration modes at frequencies several times the sampling frequency. In addition, we present experimental results showing the determination of fundamental and harmonic vibration modes of a drum style dye-doped polymer membrane tautly mounted on a 12-inch circular hoop and excited with 30 Hz and 62 Hz sinusoidal acoustic waves. The projected laser dot pattern was generated by passing the beam from a pulsed Nd:YAG laser though a diffractive optical element, and the resulting fluorescence was imaged with three digital video cameras, all of which were synchronized with a pulse and delay generator. Although the video cameras are capable of 240 Hz frame rates, the laser s output was limited to 30 Hz and below. Consequently, aliasing techniques were used to allow the measurement of vibration modes up to 186 Hz with a Nyquist limit of less than 15 Hz.

Dorrington, Adrian A.↗

SUB 1-Millimeter Size Fresnel Micro Spectrometer

An ultra-small micro spectrometer with less than 1mm diameter was constructed using Fresnel diffraction. The fabricated spectrometer has a diameter of 750 nmicrometers and a focal length of 2.4 mm at 533nm wavelength. The micro spectrometer was built with a simple negative zone plate that has an opaque center with an ecliptic shadow to remove the zero-order direct beam to the aperture slit. Unlike conventional approaches, the detailed optical calculation indicates that the ideal spectral resolution and resolving power do not depend on the miniaturized size but only on the total number of rings. We calculated 2D and 3D photon distribution around the aperture slit and confirmed that improved micro-spectrometers below 1mm size can be built with Fresnel diffraction. The comparison between mathematical simulation and measured data demonstrates the theoretical resolution, measured performance, misalignment effect, and improvement for the sub-1mm Fresnel micro-spectrometer. We suggest the utilization of an array of micro spectrometers for tunable multi-spectral imaging in the ultra violet range.

Park, Yeonjoon↗

Atmospheric-Fade-Tolerant Tracking and Pointing in Wireless Optical Communication

An acquisition, tracking, and pointing (ATP) system, under development at the time of reporting the information for this article, is intended to enable a terminal in a free-space optical communication system to continue to aim its transmitting laser beam toward a receiver at a remote terminal when the laser beacon signal from the remote terminal temporarily fades or drops out of sight altogether. Such fades and dropouts can be caused by adverse atmospheric conditions (e.g., rain or clouds). They can also occur when intervening objects block the line of sight between terminals as a result of motions of those objects or of either or both terminals

Ortiz, Gerardo↗

Laser Ranging Simulation Program

Laser Ranging Simulation Program (LRSP) is a computer program that predicts selected aspects of the performances of a laser altimeter or other laser ranging or remote-sensing systems and is especially applicable to a laser-based system used to map terrain from a distance of several kilometers. Designed to run in a more recent version (5 or higher) of the MATLAB programming language, LRSP exploits the numerical and graphical capabilities of MATLAB. LRSP generates a graphical user interface that includes a pop-up menu that prompts the user for the input of data that determine the performance of a laser ranging system. Examples of input data include duration and energy of the laser pulse, the laser wavelength, the width of the laser beam, and several parameters that characterize the transmitting and receiving optics, the receiving electronic circuitry, and the optical properties of the atmosphere and the terrain. When the input data have been entered, LRSP computes the signal-to-noise ratio as a function of range, signal and noise currents, and ranging and pointing errors.

Piazolla, Sabino↗

Free-Space Optical Communication for Spacecraft and Satellites including CubeSats in Low Earth Orbit (LEO)

A new method for optical data transmissions from satellites using laser arrays for laser beam pointing. Combines a lens system and a vertical cavity surface-emitting laser (VCSEL)/Photodetector Array, both mature technologies, in a novel way. With further development, possible applications include communications from the Earth to spacecraft in Earth orbit and in deep space, such as at the moon and Mars. A possible application is to the Artemis Program for CubeSats in low-Lunar Orbit (LLO), which use body pointing, by providing a fine pointing capability. This system has been applied to satellites in low-Earth orbit, (LEO), in a study using computer simulations of the laser beam propagation.

Goorjian, Peter M.↗

Optical systems for free-space laser communications

An overview of optical systems utilized in JPL's Optical Communications research is provided here. These include discussions on the flight terminal optics, the ground receiver aperture and the uplink beacon or command optical system. On-going efforts on these and beam-coupling techniques will be described.

Hemmati, Hamid↗

Balloon Data Readout via Free-Space Optical Communications

Free-space optical communications is a mature technology, using eye-safe beams and small-terminals, that has the potential to increase balloon data readout rates by orders of magnitude. Large commercial memory buffers paired with incredibly high-rate bursted communications – 100 Gbps has already been demonstrated with higher rates possible with existing commercial technologies – could revolutionize how science missions are designed and run. We will give an overview of the technology, show some examples of how it could already be useful to missions, and propose next steps to make affordable and robust systems be available to the balloon community.

Don Boroson↗

Dragonfly mass spectrometer titan environment optical damage testing

The Dragonfly Mass Spectrometer (DraMS) being developed at NASA’s Goddard Space Flight Center will use a solid-state 266-nm pulsed Nd:YAG laser perform compositional analysis on the surface of Titan. Due to the high fluence of the focused pulse energy on the laser’s beam steering unit (BSU) and the mass spectrometer window, the damage threshold of these optics in a Titan atmosphere needed to be characterized. This paper details the test setup and the successful demonstration of testing the highest fluence optics for the expected mission duration of 2 million laser pulses in a Titan-relevant atmosphere.

Matt Mullin↗

New Convex Grating Types for Concentric Imaging Spectrometers

The properties of convex gratings fabricated by electron-beam lithography are investigated. Three grating types are shown. These gratings allow the optical designer to fully realize the considerable advantages of concentric spectrometer forms.

spectrometers concentric imaging electron beam↗

Propagation of charge-exchange plasma produced by an ion thruster

A charge-exchange plasma is produced downstream of ion thrusters by collisions between energetic ions and neutrals escaping through the ion optics. The charge-exchange ions flow radially from the thruster beam due to electric fields produced by its density gradient. The propagation of the charge-exchange plasma after it leaves the thruster beam is the subject of this paper. Under the proper conditions there is an 'end-effect' of a long, cylindrical Langmuir probe which allows a significant increase in collected ion current when the probe is aligned with a flowing plasma. This effect is used to determine the charge-exchange plasma flow direction at various locations relative to the ion thruster. A portion of the charge-exchange plasma flows upstream of the ion thruster and can represent a contamination source to electrically propelled spacecraft. The ion current collected by the probe as a function of its angle with respect to the plasma flow allows determination of the plasma density and plasma flow velocity at the probe's location upstream of the ion thruster optics. The density value obtained from the ion current agree to within a factor of two of density values obtained by typical voltage-current Langmuir probe characteristics.

Carruth, M. R., Jr.↗

Optical diagnostics of solution crystal growth

Solution crystal growth monitoring of LAP/TGS crystals by various optical diagnostics systems, such as conventional and Mach-Zehnder (M-Z) interferometers, optical heterodyne technique, and ellipsometry, is under development. The study of the dynamics of the crystal growth process requires a detailed knowledge of crystal growth rate and the concentration gradient near growing crystals in aqueous solution. Crystal growth rate can be measured using conventional interferometry. Laser beam reflections from the crystal front as well as the back surface interfere with each other, and the fringe shift due to the growing crystal yields information about the growth rate. Our preliminary results indicate a growth rate of 6 A/sec for LAP crystals grown from solution. Single wavelength M-Z interferometry is in use to calculate the concentration gradient near the crystal. Preliminary investigation is in progress using an M-Z interferometer with 2 cm beam diameter to cover the front region of the growing crystal. In the optical heterodyne technique, phase difference between two rf signals (250 KHZ) is measured of which one is a reference signal, and the other growth signal, whose phase changes due to a change in path length as the material grows. From the phase difference the growth rate can also be calculated. Our preliminary results indicate a growth rate of 1.5 A/sec. the seed and solution temperatures were 26.46 C and 27.92 C respectively, and the solution was saturated at 29.0 C. an ellipsometer to measure the growth rate and interface layer is on order from JOBIN YVON, France. All these systems are arranged in such a manner that measurements can be made either sequentially or simultaneously. These techniques will be adapted for flight experiment.

Kim, Yongkee↗

Two-Stage Passive Vibration Isolator

The design and testing of a structural system were implemented to hold the optics of the planned Space Interferometry Mission (SIM) at positions and orientations characterized by vibrational translation and rotation errors of no more than a few nanometers or a few milliarcseconds, respectively. Much of the effort was devoted to a test bed for verifying the predicted behavior of a vibration- isolation structural subsystem working together with an active control system for positioning and orienting the SIM optics. There was considerable emphasis on the vibration-isolation subsystem, which was passive and comprised two stages. The main sources of vibration were six reaction wheels in an assembly denoted the "backpack." The first vibration-isolation stage consisted of hexapod isolator mounts - one for each reaction wheel - characterized by a natural vibration frequency of 10 Hz. The second stage was a set of three beams, disposed between the backpack and the structure that held the SIM optics, that were flexured such that they transmitted only bending loads, with a natural vibrational frequency and damping of about 5 Hz and 4 percent, respectively. Preliminary test results were presented and characterized as demonstrating the effectiveness of the two-stage vibration-isolation design.

Goullioud, Renaud↗