Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Algorithm Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

SU-E-J-169: The Dosimetric and Temporal Effects of Respiratory-Gated Radiation Therapy in Lung Cancer Patients

Purpose: To evaluate the dosimetric and temporal effects of high dose rate treatment mode for respiratory-gated radiation therapy in lung cancer patients. Methods: Treatment plans from five lung cancer patients (3 nongated (Group 1), 2 gated at 80EX-80IN (Group 2)) were retrospectively evaluated. The maximum tumor motions range from 6–12 mm. Using the same planning criteria, four new treatment plans, corresponding to four gating windows (20EX–20IN, 40EX–40IN, 60EX–60IN, and 80EX–80IN), were generated for each patient. Mean tumor dose (MTD), mean lung dose (MLD), and lung V20 were used to assess the dosimetric effects. A MATLAB algorithm was developed to compute treatment time by considering gantry rotation time, time to position collimator leaves, dose delivery time (scaled relative to the gating window), and communication overhead. Treatment delivery time for each plan was estimated using a 500 MU/min dose rate for the original plans and a 1500 MU/min dose rate for the gated plans. Results: Differences in MTD were less than 1Gy across plans for all five patients. MLD and lung V20 were on average reduced between −16.1% to −6.0% and −20.0% to −7.2%, respectively for non-gated plans when compared with the corresponding gated plans, and between − 5.8% to −4.2% and −7.0% to −5.4%, respectively for plans originally gated at 80EX–80IN when compared with the corresponding 20EX-20IN to 60EX– 60IN gated plans. Treatment delivery times of gated plans using high dose rate were reduced on average between −19.7% (−1.9min) to −27.2% (−2.7min) for originally non-gated plans and −15.6% (−0.9min) to −20.3% (−1.2min) for originally 80EX-80IN gated plans. Conclusion: Respiratory-gated radiation therapy in lung cancer patients can reduce lung toxicity, while maintaining tumor dose. Using a gated high-dose-rate treatment, delivery time comparable to non-gated normal-dose-rate treatment can be achieved. This research is supported by Siemens Medical Solutions USA, Inc.

60 APPLIED LIFE SCIENCES↗

Modeling of Dendritic Evolution of Continuously Cast Steel Billet with Cellular Automaton

In order to predict the dendritic evolution during the continuous steel casting process, a simple mechanism to connect the heat transfer at the macroscopic scale and the dendritic growth at the microscopic scale was proposed in the present work. As the core of the across-scale simulation, a two-dimensional cell automaton (CA) model with a decentered square algorithm was developed and parallelized. Apart from nucleation undercooling and probability, a temperature gradient was introduced to deal with the columnar-to-equiaxed transition (CET) by considering its variation during continuous casting. Based on the thermal history, the dendritic evolution in a 4 mm × 40 mm region near the centerline of a SWRH82B steel billet was predicted. The influences of the secondary cooling intensity, superheat, and casting speed on the dendritic structure of the billet were investigated in detail. The results show that the predicted equiaxed dendritic solidification of Fe-5.3Si alloy and columnar dendritic solidification of Fe-0.45C alloy are consistent with in situ experimental results [Yasuda et al. Int J Cast Metals Res 22:15–21 (2009); Yasuda et al. ISIJ Int 51:402–408 (2011)]. Moreover, the predicted dendritic arm spacing and CET location agree well with the actual results in the billet. The primary dendrite arm spacing of columnar dendrites decreases with increasing secondary cooling intensity, or decreasing superheat and casting speed. Meanwhile, the CET is promoted as the secondary cooling intensity and superheat decrease. However, the CET is not influenced by the casting speed, owing to the adjusting of the flow rate of secondary spray water. Compared with the superheat and casting speed, the secondary cooling intensity can influence the cooling rate and temperature gradient in deeper locations, and accordingly exerts a more significant influence on the equiaxed dendritic structure.

36 MATERIALS SCIENCE↗

Process Simulation of Cold Pressing and Sintering of Armstrong CP-Ti Powders

A computational methodology is presented for the process simulation of cold pressing and sintering of Armstrong CP-Ti powders. Since the powder consolidation is governed by specific pressure-dependent constitutive equations, solution algorithms were developed for the ABAQUS user material subroutine, UMAT, for computing the plastic strain increments based on an implicit integration of the nonlinear yield function, flow rule, and hardening equations. Sintering was simulated using a model based on diffusional creep using the user subroutine CREEP. The initial mesh, stress, and density for the simulation of sintering were obtained from the results of the cold pressing simulation, minimizing the errors from decoupling the cold pressing and sintering simulations. Numerical simulation results are presented for the cold compaction followed by a sintering step of the Ti powders. The numerical simulation results for the relative density were compared to those measured from experiments before and after sintering, showing that the relative density can be accurately predicted. Notice: This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. ACKNOWLEDGEMENTS This research was sponsored by the U.S. DOE, and carried out at ORNL, under Contract DE-AC05-00OR22725 with UT-Battelle, LLC. This research was sponsored by the U.S. DOE, EERE Industrial Technology Program Office under CPS Agreement # 17881.

36 MATERIALS SCIENCE↗

Assessing chromophoric dissolved organic matter (CDOM) distribution, stocks, and fluxes in Apalachicola Bay using combined field, VIIRS ocean color, and model observations

Understanding the role of estuarine-carbon fluxes is essential to improve estimates of the global carbon budget. Dissolved organic matter (DOM) plays an important role in aquatic carbon cycling. Here, the chromophoric fraction of DOM (CDOM) can be readily detected via in situ and remotely-sensed optical measurements. DOM properties, including CDOM absorption coefficient at 412 nm (a g 412) and dissolved organic carbon (DOC) concentrations were examined in Apalachicola Bay, a national estuarine research reserve located in the northeast Gulf of Mexico, using in situ and satellite observations during the spring and fall of 2015. Synoptic and accurate representation of estuarine-scale processes using satellite ocean color imagery necessitates the removal of atmospheric contribu- tion (~90%) to signals received by satellite sensors to successfully link to in situ observations. Three atmospheric correction schemes (e.g., Standard NIR correction, Iterative NIR correction, and SWIR correction) were tested first to find a suitable correction scheme for the VIIRS imagery in low to moderately turbid Apalachicola Bay. The iterative NIR correction performed well, and validation showed high correlation (R 2 = 0.95, N = 25) against in situ light measurements. A VIIRS-based CDOM algorithm was developed (R 2 = 0.87, N = 9) and validated (R 2 = 0.76, N = 20, RMSE = 0.29 m -1 ) against in situ observations. Subsequently, ag412 was used as a proxy of DOC in March (DOC = 1.08 + 0.94 × a g 412,R 2 =0.88, N = 13)and in November (DOC= 1.61 + 1.33 × a g 412, R 2 = 0.83, N = 24) to derive DOC maps that provided synoptic views of DOC distribution, sources, and their transport to the coastal waters during the wet and dry seasons. The estimated DOC stocks were ~3.71 × 10 6 kg C in March and ~4.07 × 10 6 kg C in November over an area of ~560 km2. Volume flux (out of the bay) almost doubled for March 24 (735 m 3 s -1 ) relative to November 4 (378 m 3 s -1 ). However, estimates of DOC fluxes exported out of the bay from model-derived currents and satellite-derived DOC were only marginally greater in March (0.163 × 10 6 kg C d -1 ) than in November (0.124 × 10 6 kg C d -1 ) and reflected greater DOC stocks in the fall. Finally, the combination of satellite-, field-, and model-based observations revealed the strong linkage between the Apalachicola River plume, a major source of DOM, and the overall hydrodynamic forcing that controlled distributions of CDOM abundance, DOC concentration, stocks, and fluxes in the bay.

54 ENVIRONMENTAL SCIENCES↗

SU-E-P-31: Quantifying the Amount of Missing Tissue in a Digital Breast Tomosynthesis

Purpose: To automatically quantify the amount of missing tissue in a digital breast tomosynthesis system using four stair-stepped chest wall missing tissue gauges in the Tomophan™ from the Phantom Laboratory and image processing from Image Owl. Methods: The Tomophan™ phantom incorporates four stair-stepped missing tissue gauges by the chest wall, allowing measurement of missing chest wall in two different locations along the chest wall at two different heights. Each of the four gauges has 12 steps in 0.5 mm increments rising from the chest wall. An image processing algorithm was developed by Image Owl that first finds the two slices containing the steps then finds the signal through the highest step in all four gauges. Using the signal drop at the beginning of each gauge the distance to the end of the image gives the length of the missing tissue gauge in millimeters. Results: The Tomophan™ was imaged in digital breast tomosynthesis (DBT) systems from various vendors resulting in 46 cases used for testing. The results showed that on average 1.9 mm of 6 mm of the gauges are visible. A small focus group was asked to count the number of visible steps for each case which resulted in a good agreement between observer counts and computed data. Conclusion: First, the results indicate that the amount of missing chest wall can differ between vendors. Secondly it was shown that an automated method to estimate the amount of missing chest wall gauges agreed well with observer assessments. This finding indicates that consistency testing may be simplified using the Tomophan™ phantom and analysis by an automated image processing named Tomo QA. In general the reason for missing chest wall may be due to a function of the beam profile at the chest wall as DBT projects through the angular sampling. Research supported by Image Owl, Inc., The Phantom Laboratory, Inc. and Raforninn ehf; Mallozzi and Healy employed by The Phantom Laboratory, Inc.; Goodenough is a consultant to The Phantom Laboratory, Inc.; Fredriksson, Kristbjornsson, Olafsson, Oskarsdottir and Olafsdottir are employed by Raforninn, Ehf.

60 APPLIED LIFE SCIENCES↗

WE-G-18A-07: Clinical Evaluation of Normalized Metal Artifact Reduction in KVCT Using MVCT Prior Images (MVCT-NMAR) Technique in Radiotherapy

Purpose: To evaluate the metal artifacts in diagnostic kVCT images of patients that are corrected using a normalized metal artifact reduction method with MVCT prior images, MVCT-NMAR. Methods: An MVCTNMAR algorithm was developed and applied to five patients: three with bilateral hip prostheses, one with unilateral hip prosthesis and one with dental fillings. The corrected images were evaluated for visualization of tissue structures and their interfaces, and for radiotherapy dose calculations. They were also compared against the corresponding images corrected by a commercial metal artifact reduction technique, O-MAR, on a Phillips™ CT scanner. Results: The use of MVCT images for correcting kVCT images in the MVCT-NMAR technique greatly reduces metal artifacts, avoids secondary artifacts, and makes patient images more useful for correct dose calculation in radiotherapy. These improvements are significant over the commercial correction method, provided the MVCT and kVCT images are correctly registered. The remaining and the secondary artifacts (soft tissue blurring, eroded bones, false bones or air pockets, CT number cupping within the metal) present in O-MAR corrected images are removed in the MVCT-NMAR corrected images. Large dose reduction is possible outside the planning target volume (e.g., 59.2 Gy in comparison to 52.5 Gy in pubic bone) when these MVCT-NMAR corrected images are used in TomoTherapy™ treatment plans, as the corrected images no longer require directional blocks for prostate plans in order to avoid the image artifact regions. Conclusion: The use of MVCT-NMAR corrected images in radiotherapy treatment planning could improve the treatment plan quality for cancer patients with metallic implants. Moti Raj Paudel is supported by the Vanier Canada Graduate Scholarship, the Endowed Graduate Scholarship in Oncology and the Dissertation Fellowship at the University of Alberta. The authors acknowledge the CIHR operating grant number MOP 53254.

60 APPLIED LIFE SCIENCES↗

Predicting and Detecting Emerging Cyberattack Patterns Using StreamWorks

The number and sophistication of cyberattacks on industries and governments have dramatically grown in recent years. To counter this movement, new advanced tools and techniques are needed to detect cyberattacks in their early stages such that defensive actions may be taken to avert or mitigate potential damage. From a cybersecurity analysis perspective, detecting cyberattacks may be cast as a problem of identifying patterns in computer network traffic. Logically and intuitively, these patterns may take on the form of a directed graph that conveys how an attack or intrusion propagates through the computers of a network. Such cyberattack graphs could provide cybersecurity analysts with powerful conceptual representations that are natural to express and analyze. We have been researching and developing graph-centric approaches and algorithms for dynamic cyberattack detection. The advanced dynamic graph algorithms we are developing will be packaged into a streaming network analysis framework known as StreamWorks. With StreamWorks, a scientist or analyst may detect and identify precursor events and patterns as they emerge in complex networks. This analysis framework is intended to be used in a dynamic environment where network data is streamed in and is appended to a large-scale dynamic graph. Specific graphical query patterns are decomposed and collected into a graph query library. The individual decomposed subpatterns in the library are continuously and efficiently matched against the dynamic graph as it evolves to identify and detect early, partial subgraph patterns. The scalable emerging subgraph pattern algorithms will match on both structural and semantic network properties.

Chin, George↗

Convective plasma stability consistent with MHD equilibrium in magnetic confinement systems with a decreasing field

A study is made of the convective (interchange, or flute) plasma stability consistent with equilibrium in magnetic confinement systems with a magnetic field decreasing outward and large curvature of magnetic field lines. Algorithms are developed which calculate convective plasma stability from the Kruskal-Oberman kinetic criterion and in which the convective stability is iteratively consistent with MHD equilibrium for a given pressure and a given type of anisotropy in actual magnetic geometry. Vacuum and equilibrium convectively stable configurations in systems with a decreasing, highly curved magnetic field are calculated. It is shown that, in convectively stable equilibrium, the possibility of achieving high plasma pressures in the central region is restricted either by the expansion of the separatrix (when there are large regions of a weak magnetic field) or by the filamentation of the gradient plasma current (when there are small regions of a weak magnetic field, in which case the pressure drops mainly near the separatrix). It is found that, from the standpoint of equilibrium and of the onset of nonpotential ballooning modes, a kinetic description of convective stability yields better plasma confinement parameters in systems with a decreasing, highly curved magnetic field than a simpler MHD model and makes it possible to substantially improve the confinement parameters for a given type of anisotropy. For the Magnetor experimental compact device, the maximum central pressure consistent with equilibrium and stability is calculated to be as high as {beta} {approx} 30%. It is shown that, for the anisotropy of the distribution function that is typical of a background ECR plasma, the limiting pressure gradient is about two times steeper than that for an isotropic plasma. From a practical point of view, the possibility is demonstrated of achieving better confinement parameters of a hot collisionless plasma in systems with a decreasing, highly curved magnetic field than those obtained with the simplest MHD description.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-15: Evaluation of 192Ir, 60Co and 169Yb Sources for High Dose Rate Prostate Brachytherapy Inverse Planning Using An Interior Point Constraint Generation Algorithm

Purpose: The effectiveness of using a combination of three sources, {sup 60}Co, {sup 192}Ir and {sup 169}Yb, is analyzed. Different combinations are compared against a single {sup 192}Ir source on prostate cancer cases. A novel inverse planning interior point algorithm is developed in-house to generate the treatment plans. Methods: Thirteen prostate cancer patients are separated into two groups: Group A includes eight patients with the prostate as target volume, while group B consists of four patients with a boost nodule inside the prostate that is assigned 150% of the prescription dose. The mean target volume is 35.7±9.3cc and 30.6±8.5cc for groups A and B, respectively. All patients are treated with each source individually, then with paired sources, and finally with all three sources. To compare the results, boost volume V150 and D90, urethra Dmax and D10, and rectum Dmax and V80 are evaluated. For fair comparison, all plans are normalized to a uniform V100=100. Results: Overall, double- and triple-source plans were better than single-source plans. The triple-source plans resulted in an average decrease of 21.7% and 1.5% in urethra Dmax and D10, respectively, and 8.0% and 0.8% in rectum Dmax and V80, respectively, for group A. For group B, boost volume V150 and D90 increased by 4.7% and 3.0%, respectively, while keeping similar dose delivered to the urethra and rectum. {sup 60}Co and {sup 192}Ir produced better plans than their counterparts in the double-source category, whereas {sup 60}Co produced more favorable results than the remaining individual sources. Conclusion: This study demonstrates the potential advantage of using a combination of two or three sources, reflected in dose reduction to organs-at-risk and more conformal dose to the target. three sources, reflected in dose reduction to organs-at-risk and more conformal dose to the target. Our results show that {sup 60}Co, {sup 192}Ir and {sup 169}Yb produce the best plans when used simultaneously and can thus be an alternative to {sup 192}Ir-only in high-dose-rate prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

Determination of the effective diffusivity of water in a poly (methyl methacrylate) membrane containing carbon nanotubes using kinetic Monte Carlo simulations

A kinetic Monte Carlo (kMC) simulation algorithm is developed for computing the effective diffusivity of water molecules in a poly(methyl methacrylate) (PMMA) matrix containing carbon nanotubes (CNTs) at several loadings. The simulations are conducted on a cubic lattice to the bonds of which rate constants are assigned governing the elementary jump events of water molecules from one lattice site to another. Lattice sites belonging to PMMA domains of the membrane are assigned different rates than lattice sites belonging to CNT domains. Values of these two rate constants are extracted from available numerical data for water diffusivity within a PMMA matrix and a CNT pre-computed on the basis of independent atomistic molecular dynamics simulations, which show that water diffusivity in CNTs is 3 orders of magnitude faster than in PMMA. Our discrete-space, continuum-time kMC simulation results for several PMMA-CNT nanocomposite membranes (characterized by different values of CNT length L and diameter D and by different loadings of the matrix in CNTs) demonstrate that the overall or effective diffusivity, D{sub eff}, of water in the entire polymeric membrane is of the same order of magnitude as its diffusivity in PMMA domains and increases only linearly with the concentration C (vol. %) in nanotubes. For a constant value of the concentration C, D{sub eff} is found to vary practically linearly also with the CNT aspect ratio L/D. The kMC data allow us to propose a simple bilinear expression for D{sub eff} as a function of C and L/D that can describe the numerical data for water mobility in the membrane extremely accurately. Additional simulations with two different CNT configurations (completely random versus aligned) show that CNT orientation in the polymeric matrix has only a minor effect on D{sub eff} (as long as CNTs do not fully penetrate the membrane). We have also extensively analyzed and quantified sublinear (anomalous) diffusive phenomena over small to moderate times and correlated them with the time needed for penetrant water molecules to explore the available large, fast-diffusing CNT pores before Fickian diffusion is reached.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pipelining RDP Data to the "Taxomatic" (Final Report)

This project builds on the results of previously funded research by integrating data and software that had been previously used in building resources used in the preparation of Bergey's Manual of Systematic Bacteriology, 2 nd Edition (Volumes 1 & 2A-C) and the Ribosomal Database Project-II (RDP-II) so as to both enhance the value of the data and create a pipeline approach to keeping the data current. Earlier, we demonstrated the value of using exploratory data analysis (EDA) to visualize large sets of sequence data (notably SSU rRNA gene sequences used in constructing a comprehensive phylogeny of prokaryotes. While the Self- Organizing Self-Correcting Classification (SOSCC) algorithms we developed were computationally efficient and useful for unraveling problems within the underlying data (e.g., identification of annotation errors, detection of unresolved synonymies, taxonomic and nomenclatural errors), bottlenecks at the preprocessing stage limited deployment of our applications as tools for end-users. To overcome the bottlenecks (which included hand alignment and computation of large matrices of pair-wise evolutionary distances), we proposed building a data pipeline between the "Taxomatic" application and RDP-II. The objectives were to accelerate the production and distribution of the updated versions of the prokaryotic taxonomy in lock-step with publication of new taxa and rearrangement of existing taxa, and to distribute these data more readily with the RDP-II and and other stakeholders in the community. A related goal of the current project is to deploy our visualization techniques as an interactive web application by which end-users can view manipulate, and select datasets of particular interest based upon phylogenetic and genomic information, access sequence data, and ultimately the scientific literature where the original observations were made and those that build on the original observations. The Taxomatic is a web-based tool to visualize distance matrices. The tool accepts raw distance matrices or aligned sequence information as data sources. When sequence information is provided the distance matrix is computed using the uncorrected distance model. Users can upload files to the Taxomatic website or sequences can be submitted by a SOAP service. This SOAP service is used by RDP to streamline Taxomatic use with RDP data. In addition to supplying source information, users can either supply their own taxonomic information by uploading it in XML, retrieve data taxonomic information from the RDP using either RDP or Genbank identifiers as source data, with or without classification by the RDP Classifier web service, or completely omit taxonomic data. In the latter case, the input distance matrix can be viewed in the order in which it was loaded.

59 BASIC BIOLOGICAL SCIENCES↗

Real-Time Dynamic Brake Assessment Proof of Concept Final Report

This proof-of-concept research was performed to explore the feasibility of using real-world braking data from commercial motor vehicles to make a diagnosis of brake condition similar to that of the performance-based brake tester (PBBT). This was done by determining the relationship between pressure and brake force (P-BF), compensating for the gross vehicle weight (GVW). The nature of this P-BF relationship (e.g., low braking force for a given brake application pressure) may indicate brake system problems. In order to determine the relationship between brake force and brake application pressure, a few key parameters of duty cycle information were collected. Because braking events are often brief, spanning only a few seconds, a sample rate of 10 Hz was needed. The algorithm under development required brake application pressure and speed (from which deceleration was calculated). Accurate weight estimation was also needed to properly derive the braking force from the deceleration. In order to ensure that braking force was the predominant factor in deceleration for the segments of data used in analysis, the data was screened for grade as well. Also, the analysis needed to be based on pressures above the crack pressure. The crack pressure is the pressure below which the individual brakes are not applied due the nature of the mechanical system. This value, which may vary somewhat from one wheel end to another, is approximately 10 psi. Therefore, only pressures 15 psi and above were used in the analysis. The Department of Energy s Medium Truck Duty Cycle research has indicated that under the real-world circumstances of the test vehicle brake pressures of up to approximately 30 psi can be expected. Several different types of data were collected during the testing task of this project. Constant-pressure stopping tests were conducted at several combinations of brake application pressure (15, 20, 25, and 30 psi), load conditions (moderately and fully laden), and speeds (20 and 30 mph). Data was collected at 10 Hz. Standard and stepped-pressure performance-based brake tests with brake pressure transducers were performed for each loading condition. The stepped-pressure test included the constant-pressure intervals of brake application at 15, 20, 25, and 30 psi. The PBBT data files included 10 Hz streaming data collected during the testing of each axle. Two weeks of real-world duty cycle (driving and braking) data was also collected at 10 Hz. Initial analysis of the data revealed that the data collected in the field (i.e., day-to-day operations) provided the same information as that obtained from the controlled tests. Analysis of the data collected revealed a strong linear relationship between brake application pressure and deceleration for given GVWs. As anticipated, initial speed was not found to be a significant factor in the deceleration-pressure relationship, unlike GVW. The positive results obtained from this proof of concept test point to the need for further research to expand this concept. A second phase should include testing over a wider range of speeds and include medium brake application pressures in addition to the low pressures tested in this research. Testing on multiple vehicles would also be of value. This future phase should involve testing to determine how degradation of braking performance affects the pressure-deceleration relationship.

99 GENERAL AND MISCELLANEOUS↗

Intermediate frequency atmospheric disturbances: A dynamical bridge connecting western U.S. extreme precipitation with East Asian cold surges: Atmospheric Rivers and IF disturbances

In this study, an atmospheric river (AR) detection algorithm is developed to investigate the downstream modulation of the eastern North Pacific ARs by another weather extreme, known as the East Asian cold surge (EACS), in both reanalysis data and high-resolution global model simulations. It is shown that following the peak of an EACS, atmospheric disturbances of intermediate frequency (IF; 10–30 day period) are excited downstream. This leads to the formation of a persistent cyclonic circulation anomaly over the eastern North Pacific that dramatically enhances the AR occurrence probability and the surface precipitation over the western U.S. between 30°N and 50°N. A diagnosis of the local geopotential height tendency further confirms the essential role of IF disturbances in establishing the observed persistent anomaly. This downstream modulation effect is then examined in the two simulations of the National Center for Atmospheric Research Community Climate System Model version 4 with different horizontal resolutions (T85 and T341) for the same period (1979–2005). The connection between EACS and AR is much better captured by the T341 version of the model, mainly due to a better representation of the scale interaction and the characteristics of IF atmospheric disturbances in the higher-resolution model. The findings here suggest that faithful representations of scale interaction in a global model are critical for modeling and predicting the occurrences of hydrological extremes in the western U.S. and for understanding their potential future changes.

54 ENVIRONMENTAL SCIENCES↗

Local time variations of high-energy plasmaspheric ion pitch angle distributions

Recent observations from the Van Allen Probes Helium Oxygen Proton Electron (HOPE) instrument revealed a persistent depletion in the 1–10 eV ion population in the postmidnight sector during quiet times in the 2 < L < 3 region. This study explores the source of this ion depletion by developing an algorithm to classify 26 months of pitch angle distributions measured by the HOPE instrument. We correct the HOPE low energy fluxes for spacecraft potential using measurements from the Electric Field and Waves (EFW) instrument. A high percentage of low count pitch angle distributions is found in the postmidnight sector coupled with a low percentage of ion distributions peaked perpendicular to the field line. A peak in loss cone distributions in the dusk sector is also observed. Here, these results characterize the nature of the dearth of the near 90° pitch angle 1–10 eV ion population in the near-Earth postmidnight sector. This study also shows, for the first time, low-energy HOPE differential number fluxes corrected for spacecraft potential and 1–10 eV H + fluxes at different levels of geomagnetic activity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep Learning for Spectroscopic X-ray Nano-Imaging Denoising

Synchrotron transmission X-ray microscopy with absorption near edge structure (TXM-XANES) is a powerful tool for investigating the structure and composition of materials at nano- to meso-scales. It is, however, often challenged by high levels of noise that obscure critical details at the single-pixel level. To address this issue, a deep learning-based algorithm is developed for suppressing the image noise, grounded in self-supervised learning principles. In contrast to traditional image denoising methods, this approach successfully enhances the visibility of fine details while significantly reducing the noise in the X-ray images. Through this advancement, the potential of the approach for improving the accuracy and interpretability of the TXM-XANES data is demonstrated, thereby enabling more precise detection of nanoscale phenomena such as inhomogeneous cation redox and metal segregation in battery cathode materials. This technique offers an effective new avenue for harnessing the full potential of synchrotron TXM-XANES imaging, paving the way for a range of exciting new studies in materials science and beyond.

36 MATERIALS SCIENCE↗

HolT Hunter: Software for Identifying and Characterizing Low-Strain DNA Holliday Triangles

Synthetic DNA nanostructures are most commonly held together via Holliday junctions. These junctions allow for a wide variety of different angles between the double helices they connect. Nevertheless, only constructs with a very limited selection of angles have been built, to date, because of the computational complexity of identifying structures that fit together with low strain at odd angles. I have developed an algorithm that finds over 95% of the possible solutions by breaking the problem down into two portions. First, there is a problem of how smooth rods can form triangles by lying across one another. This problem is easily handled by numerical computation. Second, there is the question of how distorted DNA double helices would need to be to fit onto the rod structure. This strain is calculated directly. The algorithm has been implemented in a Mathematica 8 notebook called Holliday Triangle Hunter. A large database of solutions has been identified. Additional interface software is available to facilitate drawing and viewing models.

59 BASIC BIOLOGICAL SCIENCES↗

Transitory sensitivity in automatic chemical kinetic mechanism analysis

Abstract Detailed chemical kinetic mechanisms are necessary for resolving many important chemical processes. As the chemistry of smaller molecules has become better grounded and quantum chemistry calculations have become cheaper, kineticists have become interested in constructing progressively larger kinetic mechanisms to model increasingly complex chemical processes. These large kinetic mechanisms prove incredibly difficult to refine and time‐consuming to interpret. Traditional sensitivity analysis on a large mechanism can range from inconvenient to practically impossible without special techniques to reduce the computational cost. We first present a new time‐local sensitivity analysis we term transitory sensitivity analysis. Transitory sensitivity analysis is demonstrated in an example to accurately identify traditionally sensitive reactions at an 18,000x speed up over traditional sensitivities. By fusing transitory sensitivity analysis with more traditional time‐local branching, pathway, and cluster analyses, we develop an algorithm for efficient automatic mechanism analysis. This automatic mechanism analysis at a time point is able to identify the reactions a target is most sensitive to using transitory sensitivity analysis and then propose hypotheses why the reaction might be sensitive using branching, pathway, and cluster analyses. We implement these algorithms within the reaction mechanism simulator (RMS) package, which enables us to report the automatic mechanism analysis results in highly readable text formats and in molecular flux diagrams.

Johnson, Matthew S.↗