Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Adaptive optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Soil Analysis Micro-Mission Concepts Derived from the MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatic environment, and arrays of material patches to study abrasion and adhesion. Heritage will be all-important for low cost micro-missions, and adaptations of instruments developed for the Pathfinder, '98 and '01 Landers should be strong contenders for '03 flights. This talk has three objectives: (1) Familiarize the audience with MECA instrument capabilities; (2) present concepts for stand-alone and/or mobile versions of MECA instruments; and (3) broaden the context of the MECA instruments from human exploration to a comprehensive scientific survey of Mars. Due to time limitations, emphasis will be on the chemistry and microscopy experiments. Ion-selective electrodes and related sensors in MECA's wet-chemistry laboratory will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential, and experiments will include cyclic voltammetry and anodic stripping. For experiments beyond 2001, enhancements could allow multiple use of the cells (for mobile experiments) and reagent addition (for quantitative mineralogical and exobiological analysis). MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. Future implementations might enhance the optical microscopy with spectroscopy, or incorporate advanced AFM techniques for thermogravimetric and chemical analysis.

Hecht, M. H.↗

Hyperspectral Microwave Atmospheric Sounder (HyMAS) Architecture and Design Accommodations

The Hyperspectral Microwave Atmospheric Sounder (HyMAS) is being developed at Lincoln Laboratories and accommodated by the Goddard Space Flight Center for a flight opportunity on a NASA research aircraft. The term "hyperspectral microwave" is used to indicate an all-weather sounding that performs equivalent to hyperspectral infrared sounders in clear air with vertical resolution of approximately 1 km. Deploying the HyMAS equipped scanhead with the existing Conical Scanning Microwave Imaging Radiometer (CoSMIR) shortens the path to a flight demonstration. Hyperspectral microwave is achieved through the use of independent RF antennas that sample the volume of the Earth s atmosphere through various levels of frequencies, thereby producing a set of dense, spaced vertical weighting functions. The simulations proposed for HyMAS 118/183-GHz system should yield surface precipitation rate and water path retrievals for small hail, soft hail, or snow pellets, snow, rainwater, etc. with accuracies comparable to those of the Advanced Technology Microwave Sounder. Further improvements in retrieval methodology (for example, polarization exploitation) are expected. The CoSMIR instrument is a packaging concept re-used on HyMAS to ease the integration features of the scanhead. The HyMAS scanhead will include an ultra-compact Intermediate Frequency Processor (IFP) module that is mounted inside the door to improve thermal management. The IFP is fabricated with materials made of Low-Temperature Co-fired Ceramic (LTCC) technology integrated with detectors, amplifiers, A/D conversion and data aggregation. The IFP will put out 52 channels of 16 bit data comprised of 4-9 channel data streams for temperature profiles and 2-8 channel streams for water vapor. With the limited volume of the existing CoSMIR scanhead and new HyMAS front end components, the HyMAS team at Goddard began preliminary layout work inside the new drum. Importing and re-using models of the shell, the scan head computer, and the slip rings developed for CoSMIR was the starting point. The next step was to modify the antenna faceplate to accommodate the dimensions of the three dual polarization Gaussian Optics Antenna (GOA) assemblies. Two mechanical concepts for the core technology, the hyperspectral IFP, were captured in a design tradeoff. Connector models considered minimum bend radii for the IFP analog connectors. Hyperspectral imaging is accomplished by strategically using a short wavelength intermediate frequency of 18-29 GHz, and thus reducing the size of components in the connection of the front end to the IFP. The SMK (2.92mm) Series connector will lay near the hinge line to minimize its flexing. The digital output of the IFP will use a Serial Peripheral Interface (SPI) that must be accommodated by the scan head computer. To make that computer more reliable, maintainable, and forward compatible with the 52 HyMAS channels, a testbed of the scan head, calibration, and archive computers and the PIC24 microprocessor that resides on the IFP is in development. The computers will be programmed using a new framework application called Interoperable Remote Component (IRC). This software allows flexibility to program computers that communicate with each other and can adapt easily to the emerging HyMAS requirements for data format, algorithms, and graphical user interface (GUI). It is expected that the CoSMIR instrument will cut over to the IRC after it is adapted on an updated CoSMIR testbed.

Hilliard, Lawrence↗

Thermal Vacuum Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and to verify its ability to cool large areas or components in the 3 degrees Kelvin temperature range. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully by simply applying power to both the capillary pump and the evaporator plate without pre-conditioning. It could adapt to a rapid heat load change and quickly reach a new steady state. Heat removal between 10 megawatts and 140 megawatts was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Thermal Control Systems↗

Portable Fourier Transform Spectroscopy for Analysis of Surface Contamination and Quality Control

Progress has been made into adapting and enhancing a commercially available infrared spectrometer for the development of a handheld device for in-field measurements of the chemical composition of various samples of materials. The intent is to duplicate the functionality of a benchtop Fourier transform infrared spectrometer (FTIR) within the compactness of a handheld instrument with significantly improved spectral responsivity. Existing commercial technology, like the deuterated L-alanine triglycine sulfide detectors (DLATGS), is capable of sensitive in-field chemical analysis. This proposed approach compares several subsystem elements of the FTIR inside of the commercial, non-benchtop system to the commercial benchtop systems. These subsystem elements are the detector, the preamplifier and associated electronics of the detector, the interferometer, associated readout parameters, and cooling. This effort will examine these different detector subsystem elements to look for limitations in each. These limitations will be explored collaboratively with the commercial provider, and will be prioritized to meet the deliverable objectives. The tool design will be that of a handheld gun containing the IR filament source and associated optics. It will operate in a point-and-shoot manner, pointing the source and optics at the sample under test and capturing the reflected response of the material in the same handheld gun. Data will be captured via the gun and ported to a laptop.

Pugel, Diane↗

Summer Aerosol and Trace Gas Observations in Houston, Texas Using an Adaptable Mobile Facility

An aerosol container featuring a shared inlet system was deployed to Houston, Texas in July 2022, enabling direct, high-time-resolution in situ measurements of aerosols and trace gases. The internal rack system and floorplan was designed for adaptable modularity to elucidate aerosol physicochemical processes at fine scales. The design allowed for the deployment of a core instrument suite and additional customized research grade instruments. A heterogeneous mixture of aerosols was observed during three regimes: (1) intermittent black carbon (BC) and diurnal variations in aerosol chemical composition, (2) observed particle growth associated with SO 2 , (3) transported supermicron dust. The high variability of observed particles and gases in high time resolution indicated a complex urban area with multiple local and regional sources and processes. Particle growth rates of 7–16 nm/hr were observed for submicron particles during periods when SO 2 was >0.5 ppbv. Two periods of multi-day long-range transport events of dust from the African Sahara were observed in the supermicron and submicron particle modes with total mass concentrations up to 30 μg m −3 . Aerosol scattering angstrom exponents and extinction coefficients (B ext ) increased with humidity as a function of particle composition. The measurements demonstrate collaborative capabilities that can be used to increase observations of aerosol processing, microphysical and optical properties, internal mixing state, and supermicron aerosol that are not parameterized or missing in global Earth energy system models.

54 ENVIRONMENTAL SCIENCES↗

Leaf gas exchange and fitted parameters, San Lorenzo, Panama, 2020

This data package contains photosynthetic CO2 response curves (ACi curves), light response curves (AQ curves), dark adapted dark respiration, conductance curves, and survey measurements for leaves measured at the San Lorenzo forest canopy crane site, Panama (PA-SLZ) from January to March 2020. Leaves were sampled from both the top of the canopy and multiple heights within the canopy from 10 vertical profiles and included around 50 species. In addition, six core species were also measured, from the top of the canopy. Fitted maximum carboxylation rate (Vcmax), maximum electron transport rate (Jmax), and triose phosphate utilization rate (TPU) were derived from measured data as well as the convexity, light use efficiency, apparent quantum yield, and Rdark. The measurements can also be used to derive the conductance parameters g0 and g1 of stomatal model. All the gas exchange data and metadata are presented in .csv files and complete instrument output are included in .zip folders. Data and metadata meet the ESS-DIVE leaf-level gas exchange reporting format requirements. The protocol details are provided as pdf documents. In addition to gas exchange data described here these samples were also used for measurement of leaf optical properties, carbon and nitrogen content, and leaf mass per unit leaf area (LMA) these data can be cross linked using the unique sample ID and are provided in separate related data packages. Sample information including canopy elevation and leaf area index (LAI) can be found in the related “Leaf and canopy traits” data package.

54 ENVIRONMENTAL SCIENCES↗

Leaf gas exchange and fitted parameters, two sites in Panama, 2022

Photosynthetic CO2 response curves (ACi curves), light response curves (AQ curves), dark adapted dark respiration, conductance curves, and survey measurements for leaves measured in the Parque Natural Metropolitano (PNM) and Gamboa, Panama, from January to April 2022 are presented. Measurements were made on leaves from 46 different tree, shrub and liana species, from sunlit canopy and understory locations. Leaf area index from 8 vertical profiles at PNM are also included. The aim of this measurement campaign was three-fold: (i) to improve our understanding of the vertical variation in leaf-level water use efficiency; (ii) to develop an understanding of the sensitivity of stomata to changes in environmental conditions, especially light, humidity, and temperature; (iii) to improve models which can predict leaf traits from leaf contact spectral measurements. All the gas exchange data and metadata are presented in .csv files and complete instrument output are included in .zip folders. Data and metadata meet the ESS-DIVE leaf-level gas exchange reporting format requirements. The protocol details are provided as pdf documents. In addition to gas exchange data reported here these samples were also used for measurement of leaf optical properties, carbon and nitrogen content, and leaf mass per unit leaf area (LMA). These data can be cross linked using the unique sample ID and are provided in separate data packages.

54 ENVIRONMENTAL SCIENCES↗

Cast Glance Near Infrared Imaging Observations of the Space Shuttle During Hypersonic Re-Entry

High resolution calibrated infrared imagery of the Space Shuttle was obtained during hypervelocity atmospheric entries of the STS-119, STS-125 and STS128 missions and has provided information on the distribution of surface temperature and the state of the airflow over the windward surface of the Orbiter during descent. This data collect was initiated by NASA s Hypersonic Thermodynamic Infrared Measurements (HYTHIRM) team and incorporated the use of air- and land-based optical assets to image the Shuttle during atmospheric re-entry. The HYTHIRM objective is to develop and implement a set of mission planning tools designed to establish confidence in the ability of an existing optical asset to reliably acquire, track and return global quantitative surface temperatures of the Shuttle during entry. On Space Shuttle Discovery s STS-119 mission, NASA flew a specially modified thermal protection system tile and instrumentation package to monitor heating effects from boundary layer transition during re-entry. On STS-119, the windward airflow on the port wing was deliberately disrupted by a four-inch wide and quarter-inch tall protuberance built into the modified tile. In coordination with this flight experiment, a US Navy NP-3D Orion aircraft was flown 28 nautical miles below Discovery and remotely monitored surface temperature of the Orbiter at Mach 8.4 using a long-range infrared optical package referred to as Cast Glance. Approximately two months later, the same Navy Cast Glance aircraft successfully monitored the surface temperatures of the Orbiter Atlantis traveling at approximately Mach 14.3 during its return from the successful Hubble repair mission. In contrast to Discovery, Atlantis was not part of the Boundary Layer Transition (BLT) flight experiment, thus the vehicle was not configured with a protuberance on the port wing. In September 2009, Cast Glance was again successful in capturing infrared imagery and monitoring the surface temperatures on Discovery s next flight, STS-128. Again, NASA flew a specially modified thermal protection system tile and instrumentation package to monitor heating effects from boundary layer transition during re-entry. During this mission, Cast Glance was able to image laminar and turbulent flow phenomenology optimizing data collection for Mach 14.7. The purpose of this paper is to describe key elements associated with STS-119/125/128 mission planning and execution from the perspective of the Cast Glance flight crew that obtained the imagery. The paper will emphasize a human element of experience, expertise and adaptability seamlessly coupled with Cast Glance system and sensor technology required to manually collect the required imagery. Specific topics will include a near infrared (NIR) camera upgrade that was implemented just prior to the missions, how pre-flight radiance modeling was utilized to optimize the IR sensor configuration, communications, the development of aircraft test support positions based upon Shuttle trajectory information, support to contingencies such as Shuttle one orbit wave-offs/west coast diversions and then the Cast Glance perspective during an actual Shuttle imaging mission.

Tack, Steve↗

A Heritage BioSensor for Lunar Biology Experiments

Introduction: Automated biological experiments on small spacecraft missions have gained prominence over the past decade due to their simplicity, accessibility, and small mass, volume, and power needs. Most recently, the BioSensor microfluidic CubeSat payload aboard BioSentinel used an automated microfluidic cell culture system to study the effects of environmental stressors like deep space radiation and microgravity on yeast growth and metabolism. BioSentinel’s successor, the Lunar Explorer Instrument for space biology Applications (LEIA), will study the effects of lunar gravity and radiation using an improved version of the BioSensor microfluidic platform. The BioSensor payload has great adaptability to host a diverse range of biological experiments with single- and multi-celled organisms in both crewed and uncrewed missions, making it a compelling candidate for future space biology studies in a lunar surface environment. BioSensor Instrumentation on BioSentinel: The first spaceflight mission with the BioSensor, BioSentinel’s biology experiments occurred at three locations -- deep space, ISS and ground. The payload contained 18 microfluidic cards, each featuring 16 growth wells (a total of 288 growth wells). Each well was loaded before launch with desiccated yeast. In space, liquid culture medium (nutrients) was automatically introduced to batches of wells at a time to initiate a series of biology experiments. Temperature was maintained by thin film heaters on both sides of each card. Each well was equipped with three LEDs emitting at 570 nm, 630 nm, and 850 nm, paired with photodetectors to measure cell concentration and the alamarBlue (metabolic indicator dye) color transition from blue to pink. Phenotypic parameters like cell viability, metabolic rate, and generation time can be derived from these measurements. The sequence and timing of fluid fills, optical measurements, and thermal control were stored onboard, but could be updated asynchronously via ground communication. LEIA: LEIA is slated for launch no earlier than 2026 on a CLPS lander. BioSentinel’s BioSensor has been modified for use in LEIA. These improvements include: (a) storage for multiple culture medium types, (b) additional LED color (465 nm) for a new biological assay for antioxidant (carotenoid) production, (c) housing modifications for later biology load before launch, (d) improved isolation between electronic and fluidic components, and (e) improved humidity control for prolonged organism viability in case of post-load launch delay. Future Prospects: The consistent and successful demonstration of complex fluidics platforms alongside reliable instrument operations in a space environment is poised to create strong momentum for BioSensor-based biological experiment payloads. Planned future developments with the BioSensor include extending compatibility to a broader range of organisms and assays. Preliminary work has already demonstrated successful growth of Arabidopsis seedlings in fluidic cards. With a few modifications to the optical assembly, the setup could easily measure photosynthetic traits in plants and cyanobacteria. The addition of fluorescence measurements and generation of novel luminescent assays will elevate BioSensor’s functionality further. Beyond the BioSensor’s potential uses on free-flyer missions, ISS and Gateway, and CLPS landers, deploying the BioSensor to the lunar surface or in an artificial habitat on crewed missions could enable pioneering research on both how life responds to lunar conditions and future bioproduction capabilities making the BioSensor an indispensable tool for future space biology research.

Chinmayee Govinda Raj↗

Sample-Efficient Adaptive Calibration of Quantum Networks Using Bayesian Optimization

All physical systems employed for quantum information tasks must act as unbiased carriers of encoded quantum states. Ensuring such indistinguishability of information carriers is a major challenge in many quantum information applications, including advanced quantum communication protocols. For photons, the workhorses of quantum communication networks, it is difficult to obtain and maintain their indistinguishability because of environment-induced transformations and loss imparted by communication channels, especially in noisy scenarios. Conventional strategies to mitigate these transformations often require hardware or software overhead that is restrictive (e.g., adding noise), infeasible (e.g., on a satellite), or time-consuming for deployed networks. In this work we propose and develop resource-efficient Bayesian optimization techniques to rapidly and adaptively calibrate the indistinguishability of individual photons for quantum networks using only information derived from their measurement. To experimentally validate our approach, we demonstrate the optimization of Hong-Ou-Mandel interference between two photons-a central task in quantum networking- finding rapid, efficient, and reliable convergence towards maximal photon indistinguishability in the presence of high loss and shot noise. We expect our resource-optimized and experimentally friendly methodology will allow fast and reliable calibration of indistinguishable quanta, a necessary task in distributed quantum computing, communications, and sensing, as well as for fundamental investigations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion applications. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery, and the acid dew point is a key parameter for this optimization. Commercially available acid dew point meters use electric conductivity sensors. These sensors are known to greatly underestimate the dew point due to their low sensitivity. In addition, no validation testing has been reported for these units and they are often expensive. In this work, we analyze the theory of the sulfuric acid condensation and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface as the surface temperature of the window is slowly decreased. In this way, an accurate measurement of the dew point is obtained under a wide range of concentrations. The basis of the instrument is that a collimated beam from a diode laser will generate forward scattered light when the beam encounters surface condensate, and a sophisticated array detector is used to sensitively monitor the onset of light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, to calibrate the dew point meter we developed a calibration system based on a liquid bubbler that can generate a stable gas flow with a known sulfuric acid dew point. Test results show that the dew point meter can accurately measure acid dew point over a wide range. For H2SO4 vapor concentrations as low as 6 ppm the acid dew point is measured with an error of only ~1°C. To demonstrate the versatility of this instrument, the dew point meter was adapted for use with a high-pressure flow cell to allow for measurements of the dew point of flue gas from pressurized oxy-fuel combustion in a 100 kWth pressurized reactor.

Cheng, Mao↗

On Hilbert-Huang Transform Based Synthesis of a Signal Contaminated by Radio Frequency Interference or Fringes

Norden E. Huang et al. had proposed and published the Hilbert-Huang Transform (HHT) concept correspondently in 1996, 1998. The HHT is a novel method for adaptive spectral analysis of non-linear and non-stationary signals. The HHT comprises two components: - the Huang Empirical Mode Decomposition (EMD), resulting in an adaptive data-derived basis of Intrinsic Mode functions (IMFs), and the Hilbert Spectral Analysis (HSA1) based on the Hilbert Transform for 1-dimension (1D) applied to the EMD IMF's outcome. Although paper describes the HHT concept in great depth, it does not contain all needed methodology to implement the HHT computer code. In 2004, Semion Kizhner and Karin Blank implemented the reference digital HHT real-time data processing system for 1D (HHT-DPS Version 1.4). The case for 2-Dimension (2D) (HHT2) proved to be difficult due to the computational complexity of EMD for 2D (EMD2) and absence of a suitable Hilbert Transform for 2D spectral analysis (HSA2). The real-time EMD2 and HSA2 comprise the real-time HHT2. Kizhner completed the real-time EMD2 and the HSA2 reference digital implementations respectively in 2013 & 2014. Still, the HHT2 outcome synthesis remains an active research area. This paper presents the initial concepts and preliminary results of HHT2-based synthesis and its application to processing of signals contaminated by Radio-Frequency Interference (RFI), as well as optical systems' fringe detection and mitigation at design stage. The Soil Moisture Active Passive (SMAP mission (SMAP) carries a radiometer instrument that measures Earth soil moisture at L1 frequency (1.4 GHz polarimetric - H, V, 3rd and 4th Stokes parameters). There is abundant RFI at L1 and because soil moisture is a strategic parameter, it is important to be able to recover the RFI-contaminated measurement samples (15% of telemetry). State-of-the-art only allows RFI detection and removes RFI-contaminated measurements. The HHT-based analysis and synthesis facilitates recovery of measurements contaminated by all kinds of RFI, including jamming [7-8]. The fringes are inherent in optical systems and multi-layer complex contour expensive coatings are employed to remove the unwanted fringes. HHT2-based analysis allows test image decomposition to analyze and detect fringes, and HHT2-based synthesis of useful image.

Spacecraft Electronics Equipment↗

Increased Intracranial Pressure and Visual Impairment Associated with Long-Duration Spaceflight

Although humans have been flying in space since the 1960s, more recent missions have revealed a new suite of physiological adaptations and consequences of space flight. Notably, 60% of long-duration crewmembers (ISS/MIR) and >25% of short-duration (Shuttle) crewmembers have reported subjective degradation in vision (based on debrief comments) (Gibson 2011). Decreased near-visual acuity was demonstrated in 46% of ISS/Mir and 21% of Shuttle crewmembers, resulting in a shift of up to 1-2 diopters in their refractive correction. It is likely that the recently revealed ophthalmic changes have been present since the first days of human space flight, but have been overlooked or attributed to other causations. The reported changes in vision have occurred at various time points throughout missions, with ranging degrees of visual degradation. Although some cases resolved upon return to Earth, several astronauts have not regained preflight visual acuity, indicating that the damage may be permanent. While observing these changes over the years, without other overt symptomology and with the given age range of the flying population, this has largely been attributed to an expected hyperopic shift due to aging. However, the availability of onboard analysis techniques, including visual acuity assessments, retinal imagery, and ultrasounds of the eye and optic nerve tracts, along with more detailed post-flight techniques, has led to the recent recognition of a wider syndrome. Along with vision changes, findings include flattening of the globe, swelling of the optic disc (papilledema), choroidal folds in the retina, swelling of the optic nerve sheath, and visual field defects. It is widely hypothesized that this constellation of findings may be explained by an elevation of intracranial pressure (ICP). Out of the 60% of long-duration astronauts that have reported a subjective degradation in vision, a subset (currently 10 astronauts) have developed this syndrome. The National Aeronautics and Space Administration (NASA) has made it a high priority to understand this syndrome and provide mitigation techniques to protect crewmembers from visual impairment. While there are many possible factors that could contribute to intracranial hypertension associated with spaceflight, the relative contribution of these, as well as the processes by which eye damage occurs as a result of intracranial hypertension, are not fully understood. The observed pathophysiological phenomena are extremely complex and it is likely that multiple factors contribute to their incidence, rather than one simple mechanism. This paper will define and examine the findings in detail, and expound upon the potential contributing factors and their relative contribution to this syndrome.

Marshall-Bowman, Karina↗

Three-Dimensional Measurement of the Crater Formation During Plume–Surface Interactions Using Stereo-Photogrammetry

The present investigation focused on adapting and validating stereo-photogrammetry for obtaining 3-D, time-resolved, non-intrusive, full-domain measurements of crater evolution during the plume-surface interaction (PSI) process. An atmospheric experimental facility was designed and constructed to facilitate the development of the stereo-photogrammetry technique for PSI applications. Stereo-photogrammetry was then used to measure the dynamic crater evolution process at nozzle heights of 25, 40, 55, and 70 nozzle diameters above the sand simulant bed. From the stereo-photogrammetry data, time-resolved 3-D reconstructions of the crater geometry were generated, and crater depth, radius, and volume time histories were extracted. Crater depth was observed to grow logarithmically for the two highest nozzle heights, and the depth growth rate for the lower two nozzle heights was more rapid. Crater volume growth was well characterized by a power law fit. The slope of the collapsed crater post nozzle flow was found to increase with nozzle height, along with the final crater volume. The results show that stereo-photogrammetry can be used to successfully measure the crater geometry in cases where optical access to the crater is not completely degraded by ejected particles.

DC Stubbs↗

LIRA: Probing the Lunar Surface for Resources.

The thermal, compositional and electrical properties of the lunar regolith, such as the triboelectric properties of lunar dust, the volatile content and the thermophysical properties of the polar regolith are essential to understand from a scientific perspective as well as for resource extraction and hazard mitigation. Understanding these properties specifically requires in situ measurement, as these properties are inherent in the ambient environment. With the Lunar In situ Regolith Analyzer (LIRA) we will combine mature surface sensor technologies from previous spacecraft missions (TECP) with new sensors (ClO4- ) and battery capability to achieve a compact in situ analysis package. The surface instrument suite is adapted for lunar conditions from a sensor developed as part of the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA) instrument on the 2007 Mars Phoenix mission, as well as supplemental sensors. • The Thermal and Electrical Conductivity Probe (TECP), flown on MECA/Phoenix, which measures heat capacity, thermal conductivity, electrical resistance, and electrical permittivity between needles inserted into the soil. The TECP also measured atmospheric humidity, a capability that will be retained to search for subsurface H2O ice. The Mars TECP weighed 100-gram and by definition was at TRL 9. The lunar version (LIRA) is TRL 4. • The Perchlorate (ClO4) sensor is based on the fluorescence property of perchlorate (Mg, Fe, Na). We added a light source to excite the perchlorate (ClO4) and a photo diode to collect the emission wavelength. A sun-shade over the photo diode blocks out the ambient light during day light hours. The unifying goal of LIRA is to deliver a complete, integrated experiment suite that investigates properties that must be measured in situ, and provides the capability to power the suite at night or in PSRs, as well as a means to simulate aspects of the diurnal transition by delivering an optical pulse to the surface with intensity comparable to sunlight. We describe the scientific context of LIRA, touching on the electrical state of the near-surface environment, the thermal properties of the undisturbed regolith, and the distribution, geochemistry, and mobility of water. We also address the exploration implications of the work, examining hazards and resources in the context of strategic knowledge gaps (SKGs).

Heather Smith↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Crycooling↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heaters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

cryocooling↗

Optical properties of CO2 ice and CO2 snow in the ultraviolet, visible, and infrared

The project was to measure the optical constants of CO2 ice in the spectral regions of weak absorption. Many previous measurements had been made by others in the strong absorption bands, but the weak regions had been poorly measured or not measured at all. In these regions the emissivity of CO2 frost and CO2 clouds is quite sensitive to particle sizes and to the value of the absorption coefficient, so the new measurements will have applications to energy budget and remote sensing of the Martian surface and atmosphere. During the time period covered by this grant, a method was developed for growing clear crystals of CO2, 4 cm in length. An apparatus was constructed for accurate measurement of spectral transmission through these crystals, for wavelengths 0.18-3.8 micrometers, covering the near-ultraviolet, visible, and near-infrared regions, bounded by the strong ultraviolet absorption and the 4.3-micrometer band. Our new best estimate of the spectral absorption coefficient (expressed as imaginary refractive index) is shown. It is a composite result of many measurements on dozens of crystals. Now that we have a good dataset for the shortwave absorption spectrum, the focus of the research has moved to the thermal infrared, for which a Fourier Transform interferometer has been adapted for use with C02-ice crystals.

Warren, Stephen↗