Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Experimental study of transient liquid motion in orbiting spacecraft

A test program was conducted involving forty-five drops of liquid propellant in instrumented tanks. Biaxial, low-g accelerations were applied to the model propellant tanks during free-fall testing, and forces exerted during liquid reorientation were measured and recorded. High speed photographic records of the liquid reorientation were also made. The test data was used to verify a mechanical analog which portrays the liquid as a point mass moving on an ellipsoidal constraint surface. The mechanical analog was coded into two FORTRAN 4 digital computer programs. Results showed excellent correlation between test data and analytical predictions of reorientation forces and liquid center of mass motion, verifying the basic analytical approach.

Berry, R. L.↗

Satellite borne gravity gradiometer study

Gravity gradiometry is recognized to be a very difficult instrumentation problem because extremely small differential acceleration levels have to be measured, 0.1 EU corresponds to an acceleration of 10 to the minus 11th power g at two points 1 meter apart. A feasibility model of a gravity gradiometer is being developed for airborne applications using four modified versions of the proven Model VII accelerometers mounted on a slowly rotating fixture. Gravity gradients are being measured to 1.07 EU in a vertical rotation axis orientation. Equally significant are the outstanding operational characteristics such as fast reaction time, low temperature coefficients and high degree of bias stability over long periods of time. The rotating accelerometer gravity gradiometer approach and its present status is discussed and it is the foundation for the orbital gravity gradiometer analyzed. The performance levels achieved in a 1 g environment of the earth and under relatively high seismic disturbances, lend the orbital gravity gradiometer a high confidence level of success.

Metzger, E.↗

Development of structural dynamic test environments for subsystems and components

Structural dynamic environmental test levels were developed for the thematic mapper instrument, components of the Tandberg-Hanssen instrument, and components of the International Ultraviolet Explorer spacecraft using NASTRAN structural models and test data. Both static and dynamic NASTRAN analyses were used. The model size required could be as small as 300 degrees of freedom for the static analysis and as large as 4000 degrees of freedom or more for the high frequency dynamic analysis. An important step in the development of the levels is model verification by test. The launch environments that generally dictate many important features of the design of an instrument or component are steady state acceleration, sinusoidal vibration, and random vibration.

Coladonato, R. J.↗

A solar wind experiment for the solar probe mission

Electron and ion plasma measurements on Solar Probe are important, especially to elucidate the role of coronal holes as sources of the solar wind and to resolve the long debated question of the importance of wave heating within 20 solar radii to the acceleration of the solar wind. Adaptable instruments are required to cover the large dynamic range of parameters between 1 AU and 4 solar radii. The baseline mission would be improved, in some respects, by the addition of a second spacecraft, following the first by a distance of several solar radii. A spinning spacecraft would be satisfactory, but not essential, for the present objectives. Attention should be paid to having the heat shield electrically conducting. An instrument for ion and electron (but no composition) measurements would have a mass of approximately 10 kg, require 8 w of power, and generate data at a maximum rate of approximately 2 kbits/sec.

Ogilvie, K. W.↗

A new measurement of the cosmic ray electron spectrum from 10 GeV to 300 GeV

The spectrum of cosmic-ray electrons has been measured with an instrument that combines a transition-radiation detector with a shower detector. The transition-radiation detector provides unique identification of individual electrons and good discrimination against protons. At the same time, it allows the construction of a large-area instrument (0.48 sq m ? ster) and consequently makes possible a measurement of improved statistical accuracy. The instrument has been calibrated with electron beams of 5-300 GeV at Fermilab, thus eliminating energy-dependent biases. A first balloon flight yielded 30 hours of data at an altitude of 5 g/sq cm. The design of the instrument is described, along with the accelerator calibrations and the analysis of the balloon flight data. The spectrum of electrons is found to be significantly steeper than that of protons over the whole energy range.

Hartmann, G.↗

Acceleration of electrons by interplanetary shocks

Ion acceleration is a well known phenomenon at both interplanetary shocks, while there have been only a few reports concerning an acceleration of electrons at interplanetary shocks. The considered investigation reports that electron acceleration occurs at many shocks. The instrumentation used is discussed, taking into account the ISEE 3 (International Sun Earth Explorer) spacecraft and the electrostatic analyzer employed for the measurement of electrons. Changes in the electron distribution function caused by shocks are found to be quite varied. Some events show a simple step to a higher flux level, some show fluctuations as the flux rises, and some have one or more pulses at the time of the shock. Attention is given to data obtained on July 26, 1979, December 25, 1978, and November 12, 1978. A calculation of shock geometries is also reported.

Potter, D. W.↗

Mass spectrometer for measurements of relative ion concentrations in plasmas

A mass spectrometer which can be used to measure relative ion concentrations in a multiion component plasma has been designed for use in a strong (1-4-kG) uniform magnetic field. The spectrometer features an acceleration region which accelerates thermal ions through a series of three tantalum electrodes at a 30 deg angle to the B field, and a collection region in which ions are selectively collected, depending on the size of their gyroradii, by a cylindrical collector. Relative ion concentrations are determined from measurements of the collector current as a function of accelerating voltage. Results obtained using this instrument in a Q-machine device operated with a two-ion (Cs+/K+) component plasma are presented.

Suszcynsky, David M.↗

Scientific tradeoffs in pinhole/occulter facility accommodation

The Pinhole/Occulter Facility (P/OF) consists of state-of-the-art instruments for the study of particle acceleration in the solar corona, and uses a large structure to obtain very high angular resolution. P/OF has been studied in the past as an attached payload for the Space Shuttle, and has been the subject of study by a NASA Science Working Group (P/OFSWG). Appendix A lists various technical studies and reports carried out under the auspices of P/OFSWG and the Program Development Office of NASA Marshall Space Flight Center. Under the rationalization of NASA flight opportunities following the Challenger disaster, and the beginning of the Space Station Freedom program, the sortie-mode deployment of P/OF seemed less efficient and desirable. Thus, NASA decided to reconsider P/OF for deployment on the Space Station Freedom. The technical studies for this deployment continue at the present and will evolve as our knowledge of Space Station architecture and capabilities increase. MSFC contracted with Teledyne Brown Engineering for these technical studies.

Hudson, Hugh S.↗

Microgravity science requirements and the need for data compression

The Microgravity Science and Applications Div. (MSAD) of the NASA Office of Space Science and Applications (OSSA) is responsible for encouraging and directing the research of a wide range of physical phenomena in reduced gravity. Under MSAD's direction, NASA-Lewis is presently developing the concept of a multiuser facility which will perform combustion science experiments in space. This facility, the Combustion Experiment Module (CEM), will be located in either the Shuttle Spacelab or the Space Station Freedom lab and will be operational by mid-1997. In addition to standard instrumentation to measure temperature, pressure, and acceleration, CEM shall use a variety of imaging and optical diagnostic techniques. Images shall be the primary source of experimental data. These images create an enormous amount of data which must be archived on orbit for later analysis. Also, ground based investigators will require enough data from the orbiting facility to determine if the experimental parameters need to be changed before proceeding with the next run. The storage and transmission of this data present a major challenge to the CEM design. Data compression will play a major role in the design of the CEM diagnostics system.

Hartz, William G.↗

LANSCE wire scanner AFE: analysis, design, and fabrication

The goal of the design LANSCE-R Wire-Scanner Analog Front-end Electronics is to develop a high-performance, dual-axis wire-scanner analog front-end system implemented in a single cRIO module. This new design accommodates macropulse widths as wide as 700 {mu}s at a maximum pulse rate of 120Hz. A lossey integrator is utilized as the integration element to eliminate the requirement for providing gating signals to each wire scanner. The long macropulse and the high repetition rate present conflicting requirements for the design of the integrator. The long macropulse requires a long integration time constant to assure minimum integrator droop for accurate charge integration, and the high repetition rate requires a short time constant to assure adequate integrator reset between macropulses. Also, grounding is a serious concern due to the small signal levels. This paper reviews the basic Wire Scanner AFE system design implemented in the cRIO-module form factor to capture the charge information from the wire sensors and the grounding topology to assure minimum noise contamination of the wire signals.

43 PARTICLE ACCELERATORS↗

Combined XRD and XAS

X-ray diffraction (XRD) and X-ray absorption fine structure (XAFS) are complementary techniques for investigating the structure of materials. XRD probes long range order and XAFS probes short range order. We have combined the two techniques at one synchrotron beamline, X18A at the NSLS, allowing samples to be studied in a single experiment. This beamline will allow for coordinated measurements of local and long range structural changes in chemical transformations and phase transitions using both techniques.

43 PARTICLE ACCELERATORS↗

Application of partially coherent wavefront propagation calculations for design of coherence-preserving synchrotron radiation beamlines

Ultra-low emittance third-generation synchrotron radiation (SR) sources, such as NSLS-II and MAX-IV, will offer excellent opportunities for further development of experimental techniques exploiting X-ray coherence. However, even in these new SR sources, the radiation produced by relativistic electrons (in undulators, wigglers and bending magnets) will remain only partiallycoherent in the X-ray spectral range. 'Extraction' of 'coherent portion' of the radiation flux and its transport to sample without loss of coherence must be performed by dedicated SR beamlines, optimized for particular types of experiments. Detailed quantitative prediction of partially coherent X-ray beam properties at propagation through optical elements, which is required for the optimization of such beamlines, can only be obtained from accurate and efficient physical-optics based numerical simulations. Examples of such simulations, made for NSLS-II beamlines, using 'Synchrotron Radiation Workshop' (SRW) computer code, are presented. Special attention is paid to the numerical analysis of the basic properties of partially coherent undulator radiation beam and its distinctions from the Gaussian beam. Performance characteristics of importance for particular beamlines, such as radiation spot size and flux at sample vs size of secondary source aperture for high-resolution microscopy beamlines, are predicted by the simulations.

43 PARTICLE ACCELERATORS↗

High efficiency multilayer blazed gratings for EUV and soft X-rays: Recent developments

Multilayer coated blazed gratings with high groove density are the best candidates for use in high resolution EUV and soft x-ray spectroscopy. Theoretical analysis shows that such a grating can be potentially optimized for high dispersion and spectral resolution in a desired high diffraction order without significant loss of diffraction efficiency. In order to realize this potential, the grating fabrication process should provide a perfect triangular groove profile and an extremely smooth surface of the blazed facets. Here we report on recent progress achieved at the Advanced Light Source (ALS) in fabrication of high quality multilayer coated blazed gratings. The blazed gratings were fabricated using scanning beam interference lithography followed by wet anisotropic etching of silicon. A 200 nm period grating coated with a Mo/Si multilayer composed with 30 bi-layers demonstrated an absolute efficiency of 37.6percent in the 3rd diffraction order at 13.6 nm wavelength. The groove profile of the grating was thoroughly characterized with atomic force microscopy before and after the multilayer deposition. The obtained metrology data were used for simulation of the grating efficiency with the vector electromagnetic PCGrate-6.1 code. The simulations showed that smoothing of the grating profile during the multilayer deposition is the main reason for efficiency losses compared to the theoretical maximum. Investigation of the grating with cross-sectional transmission electron microscopy revealed a complex evolution of the groove profile in the course of the multilayer deposition. Impact of the shadowing and smoothing processes on growth of the multilayer on the surface of the sawtooth substrate is discussed.

43 PARTICLE ACCELERATORS↗