Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

A plasma–vacuum interface tracking algorithm for magnetohydrodynamic simulations of coaxial plasma accelerators

The resistive Magneto-hydrodynamic (MHD) model describes the behavior of a strongly ionized plasma in the presence of external electric and magnetic fields. For problems involving the plasma with an open boundary to very low pressure/vacuum regions, the continuum assumption is no longer valid in the entire domain of interest. For example, this is seen in a plasma accelerator where a dense plasma expands into a vacuum background. A common practice to deal with this issue is to assign small values of density and pressure to the vacuum regions and proceed to solve the continuum based MHD equations throughout the domain. We show that this approach fails to produce solutions consistent with the physics of the problem and can give rise to unacceptable artifacts such as spurious shocks. Here, we develop a plasma–vacuum interface tracking approach to mitigate this problem. The plasma–vacuum interface is tracked in a physically consistent manner and the MHD equations are solved only in the regions that contain the plasma. The interface tracking is achieved using a face-flux formulation derived from the theoretical solution to a 1D free expansion problem. Coupled with a threshold based approach, the interface tracking is implemented for both explicit and implicit time stepping frameworks on generalized unstructured grids. Simulations of magnetized thermal plasma jets expanding into a vacuum background indicate plume profiles devoid of the unphysical shock obtained using the small background density approach. In the context of resistive MHD simulations, the interface tracking approach overcomes the numerical stiffness induced by specifying a large background resistivity in the vacuum regions, resulting in significant wall-clock time gains.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An improved stochastic weighted particle method for boundary driven flows

Here, the stochastic weighted particle method (SWPM) is a generalization of the Direct Simulation Monte Carlo (DSMC) method where particle weights are variable and dynamic. SWPM is backed by a strong theoretical foundation but has not been critically evaluated for problems of practical interest. A thorough assessment of SWPM for boundary-driven flows reveals significant numerical artifacts near the boundary, notably a diverging heat flux. To correct the boundary heat flux, two modifications to SWPM are proposed: separated grouping and a spatially-dependent weight transfer function. To gauge the relative efficiency of SWPM in comparison to DSMC, a high-Mach-number wheel flow which forms a strong density gradient is also simulated.

97 MATHEMATICS AND COMPUTING↗

A coupled THMC model of a heating and hydration laboratory experiment in unsaturated compacted FEBEX bentonite

Unsaturated compacted bentonite is foreseen by several countries as a backfill and sealing material in high-level radioactive waste repositories. The strong interplays between thermal (T), hydrodynamic (H), mechanical (M) and chemical (C) processes during the hydration stage of a repository call for fully coupled THMC models. Validation of such THMC models is prevented by the lack of comprehensive THMC experiments and the difficulties of experimental methods to measure accurately the chemical composition of bentonite porewater. We present here a non-isothermal multiphase flow and multicomponent reactive solute transport model for a deformable medium of a heating and hydration experiment performed on a sample of compacted FEBEX bentonite. Besides standard solute transport and geochemical processes, the model accounts for solute cross diffusion and thermal and chemical osmosis. Bentonite swelling is solved with a state-surface approach. The THM model is calibrated with transient temperature, water content and porosity data measured at the end of the experiment. The reactive transport model is calibrated with porewater chemical data derived from aqueous extract data. Model results confirm that thermal osmosis is relevant for the hydration of FEBEX bentonite while chemical osmosis can be safely neglected. Dilution and evaporation are the main processes controlling the concentration of conservative species. Dissolved cations are mostly affected by calcite dissolution-precipitation and cation exchange reactions. Dissolved sulphate is controlled by gypsum/anhydrite dissolution-precipitation. pH is mostly buffered by protonation/deprotonation via surface complexation. Computed concentrations agree well with inferred aqueous extract data at all sections except near the hydration boundary where cation data are affected by a sampling artifact. The fit of Cl{sup -} data is excellent except for the data near the heater. The largest deviations of the model from inferred aqueous extract data occur for dissolved SO{sub 4}{sup 2-} which is underpredicted by the model. There are uncertainties on the amount of gypsum available for dissolution and its dissolution mechanism (kinetics or local equilibrium).

54 ENVIRONMENTAL SCIENCES↗

Structure and Binding Mechanism of Vascular Endothelial Cadherin: A Divergent Classical Cadherin

Vascular endothelial cadherin (VE-cadherin), a divergent member of the type II classical cadherin family of cell adhesion proteins, mediates homophilic adhesion in the vascular endothelium. Previous investigations with a bacterially produced protein suggested that VE-cadherin forms cell surface trimers that bind between apposed cells to form hexamers. Here we report studies of mammalian-produced VE-cadherin ectodomains suggesting that, like other classical cadherins, VE-cadherin forms adhesive trans dimers between monomers located on opposing cell surfaces. Trimerization of the bacterially produced protein appears to be an artifact that arises from a lack of glycosylation. We also present the 2.1-{angstrom}-resolution crystal structure of the VE-cadherin EC1-2 adhesive region, which reveals homodimerization via the strand-swap mechanism common to classical cadherins. In common with type II cadherins, strand-swap binding involves two tryptophan anchor residues, but the adhesive interface resembles type I cadherins in that VE-cadherin does not form a large nonswapped hydrophobic surface. Thus, VE-cadherin is an outlier among classical cadherins, with characteristics of both type I and type II subfamilies.

59 BASIC BIOLOGICAL SCIENCES↗

Stability of SiC and its Composites at High Neutron Fluence

High purity chemically vapor-deposited (CVD) silicon carbide (SiC) and near-stoichiometric SiC fiber, chemically vapor-infiltrated (CVI) SiC matrix composite were evaluated following neutron irradiation to {approx}28 dpa at 300 and 650 C and to {approx}41 dpa at 800 C, respectively. The irradiated swelling, thermal conductivity, and elastic modulus indicated no additional changes in these properties at high fluences after saturation at low fluences. With a statistically meaningful sample population, no change in flexural strength of CVD SiC was observed after 300 C irradiation. A slight decrease in strength was observed after 650 C irradiation but was attributed to an experimental artifact; specifically, a reaction between samples and the capsule components. The Hi-Nicalon{trademark} Type-S, CVI SiC composite retained the pre-irradiation strength and the non-linear fracture mode. The electrical resistivity measurement revealed a relatively minor effect of irradiation. Overall, irradiation-insensitivity of the high purity SiC ceramics and composite to neutron irradiation to doses 30-40 dpa at temperatures 300-800 C was demonstrated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Three-dimensional microstructural characterization of bulk plutonium and uranium metals using focused ion beam technique

Nuclear forensics requires accurate quantification of discriminating microstructural characteristics of the bulk nuclear material to identify its process history and provenance. Conventional metallographic preparation techniques for bulk plutonium (Pu) and uranium (U) metals are limited to providing information in two-dimension (2D) and do not allow for obtaining depth profile of the material. In this contribution, use of dual-beam focused ion-beam/scanning electron microscopy (FIB-SEM) to investigate the internal microstructure of bulk Pu and U metals is demonstrated. Our results demonstrate that the dual-beam methodology optimally elucidate microstructural features without preparation artifacts, and the three-dimensional (3D) characterization of inner microstructures can reveal salient microstructural features that cannot be observed from conventional metallographic techniques. As a result, examples are shown to demonstrate the benefit of FIB-SEM in improving microstructural characterization of microscopic inclusions, particularly with respect to nuclear forensics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improved instrumentation for intensity-, wavelength-, temperature-, and magnetic field-resolved photoconductivity spectroscopy

We report instrumentation for photovoltage and photocurrent spectroscopy over a larger continuous range of wavelengths, temperatures, and applied magnetic fields than other instruments described in the literature: 350 nm≤λ≤1700 nm, 1.8 K≤T≤300 K, and B≤9 T. This instrument uses a modulated monochromated incoherent light source with total power<30 μW in combination with an LED in order to probe selected regions of non-linear responses while maintaining low temperatures and avoiding thermal artifacts. The instrument may also be used to measure a related property, the photomagnetoresistance. We demonstrate the importance of normalizing measured responses for variations in light power and describe a rigorous process for performing these normalizations. We discuss several circuits suited to measuring different types of samples and provide analysis for converting measured values into physically relevant properties. Uniform approaches to measurement of these photoproperties are essential for reliable quantitative comparisons between emerging new materials with energy applications. - Highlights: • A novel instrument for measuring photoconductivity and photocurrents of materials and devices. • Continuous parameter space: 350 nm≤λ≤1700, 1.8 K≤T≤300 K, and B≤9 T. • Methodology for treating non-linear responses and variable lamp intensity. • Mathematical detail for extracting properties of materials from measured values is provided.

36 MATERIALS SCIENCE↗

TEM specimen preparation of semiconductor-PMMA-metal interfaces

Transmission electron microscopy (TEM) cross-section specimens of PMMA in contact with gold and Si were prepared by focused ion beam (FIB) and compared with plan-view PMMA specimens prepared by a dip-coating technique. The specimens were characterized by TEM and electron energy loss spectroscopy (EELS). In the cross-section specimens, the thin films of PMMA were located in a Si-PMMA-Au multilayer. Different thicknesses of PMMA films were spin-coated on the Si substrates. The thickness of the TEM specimens prepared by FIB was estimated using EELS to be 0.65 of the plasmon mean-free-path. Along the PMMA-Au interface, Au particle diffusion into the PMMA was observed, and the size of the Au particles was in the range of 2-4 nm. Dip-coating of PMMA directly on Cu TEM grids resulted in thin specimens with a granular morphology, with a thickness of 0.58 of the plasmon mean-free-path. The dip-coated specimens were free from ion milling induced artifacts, and thus serve as control specimens for comparison with the cross-sectioned specimens prepared by FIB.

36 MATERIALS SCIENCE↗

Evaluation of strain caused by coherent precipitates in an Al alloy using TEM techniques

Elastic strains, caused by GP zones in an aged Al alloy, were determined quantitatively using two techniques: Dark Field In-line Holography (DFH) and High Resolution Transmission Electron Microscopy-Geometric Phase Analysis (HRTEM-GPA). The results obtained by both techniques showed that the elastic strain was not uniform along the precipitate-matrix interface. In some areas, it was found that strain had negligible value and this was attributed to the loss of coherence between the lattices. It is suggested that a possible explanation for this fact could be a variation in the 'vacancies pump mechanism' kinetics. To obtain a better interpretation of the experimental deformation maps, a reference GP precipitate-matrix structure was built using QSTEM software. The main advantages of DFH over HRTEM-GPA were a bigger field of view and low electron dose requirements without spatial resolution loss. Another difference found was that crystalline defects such as dislocations were evidenced by HRTEM-GPA in contrast to the result obtained by DFH. However, strain measurements were affected by mask size effect in the former. - Highlights: Black-Right-Pointing-Pointer Strain around GP precipitates was not uniform and was in a more relaxed state. Black-Right-Pointing-Pointer Strain values determined by HRTEM had more artifacts compared with holography ones. Black-Right-Pointing-Pointer Strain distribution was attributed to differences in the release of vacancies. Black-Right-Pointing-Pointer Holography showed important advantages over HRTEM regarding field of view mainly.

36 MATERIALS SCIENCE↗

On the importance of FIB-SEM specific segmentation algorithms for porous media

A new algorithmic approach to segmentation of highly porous three dimensional image data gained by focused ion beam tomography is described which extends the key-principle of local threshold backpropagation described in Salzer et al. (2012). The technique of focused ion beam tomography has shown to be capable of imaging the microstructure of functional materials. In order to perform a quantitative analysis on the corresponding microstructure a segmentation task needs to be performed. However, algorithmic segmentation of images obtained with focused ion beam tomography is a challenging problem for highly porous materials if filling the pore phase, e.g. with epoxy resin, is difficult. The gray intensities of individual voxels are not sufficient to determine the phase represented by them and usual thresholding methods are not applicable. We thus propose a new approach to segmentation that pays respect to the specifics of the imaging process of focused ion beam tomography. As an application of our approach, the segmentation of three dimensional images for a cathode material used in polymer electrolyte membrane fuel cells is discussed. We show that our approach preserves significantly more of the original nanostructure than a thresholding approach. - Highlights: • We describe a new approach to the segmentation of FIB-SEM images of porous media. • The first and last occurrences of structures are detected by analysing the z-profiles. • The algorithm is validated by comparing it to a manual segmentation. • The new approach shows significantly less artifacts than a thresholding approach. • A structural analysis also shows improved results for the obtained microstructure.

36 MATERIALS SCIENCE↗

Transmission Kikuchi diffraction and transmission electron forescatter imaging of electropolished and FIB manufactured TEM specimens

We present a study of the efficiency of the utility of scanning electron microscope (SEM)-based transmission methods for characterizing grain structure in thinned bulk metals. Foils of type 316 stainless steel were prepared by two methods commonly used for transmission electron microscopy — double-jet electropolishing and focused ion beam milling. A customized holder allowed positioning of the foils in a configuration appropriate for both transmission electron forward scatter diffraction, and for transmission imaging by the use of a forescatter detector with two diodes. We found that both crystallographic orientation maps and dark-field transmitted images could be obtained for specimens prepared by either method. However, for both methods, preparation-induced artifacts may affect the quality or accuracy of transmission SEM data, especially those acquired by the use of transmission Kikuchi diffraction. Generally, the quality of orientation data was better for specimens prepared by electropolishing, due to the absence of ion-induced damage. - Highlights: • The transmission imaging and diffraction techniques are emerging in scanning electron microscopy (SEM) as promising new field of materials characterization. • The manuscript titled: “Transmission Kikuchi Diffraction and Transmission Electron Forescatter Imaging of Electropolished and FIB Manufactured TEM Specimens” documents how different specimen thinning procedures can effect efficiency of transmission Kikuchi diffraction and transmission electron forescatter imaging. • The abilities to make precision crystallographic orientation maps and dark-field images in transmission was studied on electropolished versus focus ion beam manufactured TEM specimens. • Depending on the need, electropolished and focused ion beam technique may produce suitable specimens for transmission imaging and diffraction in SEM.

36 MATERIALS SCIENCE↗

Background of SAM atom-fraction profiles

Atom-fraction profiles acquired by SAM (scanning Auger microprobe) have important applications, e.g. in the context of alloy surface engineering by infusion of carbon or nitrogen through the alloy surface. However, such profiles often exhibit an artifact in form of a background with a level that anti-correlates with the local atom fraction. This article presents a theory explaining this phenomenon as a consequence of the way in which random noise in the spectrum propagates into the discretized differentiated spectrum that is used for quantification. The resulting model of “energy channel statistics” leads to a useful semi-quantitative background reduction procedure, which is validated by applying it to simulated data. Subsequently, the procedure is applied to an example of experimental SAM data. The analysis leads to conclusions regarding optimum experimental acquisition conditions. The proposed method of background reduction is based on general principles and should be useful for a broad variety of applications. - Highlights: • Atom-fraction–depth profiles of carbon measured by scanning Auger microprobe • Strong background, varies with local carbon concentration. • Needs correction e.g. for quantitative comparison with simulations • Quantitative theory explains background. • Provides background removal strategy and practical advice for acquisition.

36 MATERIALS SCIENCE↗

A comparison of He and Ne FIB imaging of cracks in microindented silicon nitride

Highlights: • Silicon nitride was successfully imaged with helium and neon ion microscopy. • Indent-induced cracking was resolved on conductively-coated and uncoated samples. • Cracking was found to be primarily intergranular in nature. • The grain microstructure was most visible on the carbon-coated sample. • For the carbon-coated sample, localized charging was observed along crack pathways. - Abstract: Helium ion microscopy (HIM) offers potential as a high spatial resolution technique for imaging insulating samples that are susceptible to charging artifacts. In this study helium and neon ion microscopy are used to image cracking in microindented samples of the non-conductive ceramic silicon nitride. The crack morphology of radial cracks emanating from the microindentations has been characterized for two different compositions of silicon nitride, with and without conductive coatings. Gold coating enhances crack edge contrast, but masks grain contrast for both He and Ne ion-induced secondary electron (ISE) imaging. Carbon coating enables the crystalline and glassy phases to be distinguished, more clearly with Ne-ISE, and the cracking pathway is found to be primarily intergranular. Zones of <100 nm diameter depleted ion-induced secondary electron emission along the crack paths are identified, consistent with charging ‘hotspots’.

36 MATERIALS SCIENCE↗

Data clustering for the high-resolution alignment of microstructure and strain fields

The emergence of small-scale deformation mapping by a combination of scanning electron microscopy and digital image correlation (SEM-DIC) has enabled full-field investigations into the complex roles of microstructure on microscale deformation mechanisms. However, these investigations are hindered by errors in alignment between the microstructure data, generally acquired by electron backscatter diffraction (EBSD), and the microscale strain data obtained by SEM-DIC. Distortions, stitching artifacts, and spatial resolution differences between microstructure and strain fields can lead to misalignments on the order of μms. This alignment uncertainty introduces error into microstructure-strain localization analyses and precludes the examination of deformation mechanisms near grain boundaries. To improve alignment between EBSD-obtained grain boundaries and SEM-DIC strain data, an approach was created wherein a mantle was first established around the EBSD-acquired grain boundaries. Strain data was then clustered within this mantle using a k-means algorithm to identify grain boundary strain localization, and these boundary points were fit to obtain a continuous curve for each individual boundary. Clustered point outliers, such as those due to grain boundary-local dislocation slip, were statistically identified by using an absolute error threshold and removed from the grain boundary fit. The ending identification of grain boundaries in the microscale strain data is significantly improved from EBSD-identified boundaries.

36 MATERIALS SCIENCE↗

Neutron diffraction probing hydrogen in monoclinic H 2 VOPO 4

Light hydrogen atoms are resolvable with neutrons; however, the massive incoherent background inhibits the diffraction quality. To improve the signal, isotope treatment by deuteration becomes a prerequisite for a successful crystallographic understanding of hydrogen-containing materials by neutron diffraction. Thanks to the low-background and high-resolution time-of-flight neutron diffractometer, this work demonstrates a direct and successful measurement of high-quality neutron diffraction patterns of H 2 VOPO 4 powders, a precursor of a high-capacity alkali-ion battery cathode. The Rietveld refinement identifies the hydrogen coordinates, occupancy, and thermal parameters in the H 2 VOPO 4 lattice. Finally, the result highlights the unique capability of neutron diffraction for the structure characterization of hydrogen-containing materials, potentially without requiring costly and possibly artifact-inducing deuteration for neutron diffraction.

36 MATERIALS SCIENCE↗

Avoiding erroneous analysis of MIM diode current-voltage characteristics through exponential fitting

Accurate fitting of measured current-voltage [$I$ ($V$) ] data is crucial to the correct analysis and understanding of metal-insulator–metal (MIM) diodes, especially for optical rectennas. With the commonly used polynomial fitting of the $I$$(V)$ data, the order of the fit can drastically affect the diode performance metrics such as resistance, responsivity, and asymmetry. Additionally, the resulting fitting coefficients provide no useful parameters. An exponential-based equation can fit the $I$$(V)$ data well, can avoid artifacts from the choice of order of the polynomial, and allows for the accurate calculation of diode performance metrics directly from the fitting coefficients. Finally, connecting the performance metrics to fitting coefficients shows a correspondence between zero-bias responsivity and asymmetry at any given voltage.

42 ENGINEERING↗

A machine-learning approach to measure 3D sample properties from 2D Transmission Electron Microscopy images

Transmission Electron Microscopy (TEM) is a powerful tool for the characterization of materials at the nanoscale; however, its inherent two-dimensional (2D) nature poses significant challenges to accurately measure three-dimensional (3D) properties. We introduce a supervised machine-learning model that predicts 3D structural information, such as sample thickness and curvature, from a series of conventional 2D TEM images. The model, a U-Net convolutional neural network, is trained on a large synthetic dataset generated from dynamical diffraction simulations that model TEM’s complex, nonlinear image formation, accounting for sample thickness and curvature. This physically realistic framework enables exploration of a broad parameter space impractical to sample experimentally. We demonstrate that the trained model has accurate predictions for experimental single-crystal silicon samples, achieving performance comparable to established measurement techniques. This work highlights the critical role of robust, simulation-based training in overcoming the limitations of real-world imaging artifacts and inconsistent sample geometries. By integrating machine learning with numerical simulations, we offer an efficient and scalable framework for quantitative TEM analysis, paving the way for more sophisticated 3D characterization of complex materials.

Dynamical diffraction↗