Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Experimental measurement of energy release from an initiating layer in an insensitive explosive

When subjected to a shock of insufficient strength to trigger prompt reaction, heterogenous condensed phase explosives can form regions where significant amounts of the explosive remain unreacted for times much greater than the reaction time of the detonating explosive. This phenomena is observed for the explosive PBX 9502 (95 wt% TATB) both for planar and oblique input shocks. Here, we build on previous results by performing cylinder expansion (CYLEX) tests where the explosive charge is comprised of a faster core of PBX 9501 (95 wt% HMX) inside a slower annulus of PBX 9502. The detonation in the faster PBX 9501 drives an oblique shock into the adjacent PBX 9502, and an annular transverse initiating layer (IL) results. In the test geometry, the IL travels steadily down the length of the test after a short run distance. At radial positions beyond the IL, an annular region of detonating PBX 9502 is observed. Using standard CYLEX test diagnostics, we infer the total energy release of this experiment. By making the assumptions that (1) the combined energy release is comprised of contributions from detonating PBX 9501, detonating PBX 9502, and the IL in the PBX 9502 and (2) mass-specific energy release for the detonating explosives is approximately the same as typically observed for each explosive, the IL energy release and reaction efficiency can be computed. Results are compared to prior results for a similar geometry, and indicate that while shock deadened PBX 9502 does not detonate promptly, it does eventually release a significant portion of its chemical potential energy over longer timescales on the order of 10 µs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Intercomparison of Laboratory Radiance Calibration Standards

Several standards for radiometric calibration were measured repeatedly with a spectroradiometer in order to understand how they compared in accuracy and stability. The tested radiance standards included a NIST 1000 W bulb and halon panel, two calibrated and stabilized integrating spheres, and a cavity blackbody. Results indicate good agreement between the blackbody and 1000 W bulb/spectralon panel, If these two radiance sources are assumed correct, then the integrating spheres did not conform. to their manufacturer-reported radiances in several regions of the spectrum. More detailed measurements am underway to investigate the discrepancy.

Pavri, Betina↗

Bulk Electrical Cable Non-Destructive Examination Methods for Nuclear Power Plant Cable Aging Management Programs

This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of nondestructive test methods focusing particularly on bulk electrical test methods that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As nuclear power plants consider applying for second, or subsequent, license renewal to extend their operating period from 60 years to 80 years, it is important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program, however, is directed toward the more demanding challenge of assuring the cable function under accident or DBE. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB, however, is a destructive test so the test programs must apply an array of other nondestructive examination (NDE) tests to assure or infer the overall set of cable’s system integrity. Assessment of cable integrity is further complicated in many cases by vendor’s use of dissimilar material for jacket and insulation. Frequently the jacket will degrade more rapidly than the underlying insulation. Although this can serve as an early alert to cable damage, direct test of the cable insulation without violating the protective jacket becomes problematic. This report addresses the range of bulk electrical NDE cable tests that are or could be practically implemented in a field-test situation with a particular focus on frequency domain reflectometry (FDR). The FDR test method offers numerous advantages over many other bulk electrical tests. Two commercial FDR systems plus a laboratory vector network analyzer are used to test an array of aged and un-aged cables under identical conditions. Several conclusions are set forth, and a number of knowledge gaps are identified.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Towards validation of combined-accelerated stress testing through failure analysis of polyamide-based photovoltaic backsheets

Abstract Novel methods for advancing reliability testing of photovoltaic (PV) modules and materials have recently been developed. Combined-accelerated stress testing (C-AST) is one such method which has demonstrated reliable reproduction of some field-failures which were not reproducible by standard certification tests. To increase confidence and assist in the development of C-AST, and other new testing protocols, it is important to validate that the failure modes observed and mechanisms induced are representative of those observed in the field, and not the product of unrealistic stress conditions. Here we outline a method using appropriate materials characterization and modelling to validate the failure mechanisms induced in C-AST such that we can increase confidence in the test protocol. The method is demonstrated by applying it to a known cracking failure of a specific polyamide (PA)-based backsheet material. We found that the failure of the PA-based backsheet was a result of a combination of stress factors. Photo-oxidation from ultra-violet (UV) radiation exposure caused a reduction in fracture toughness, which ultimately lead to the cracking failure. We show that the chemical and structural changes observed in the backsheet following C-AST aging were also observed in field-aged samples. These results increase confidence that the conditions applied in C-AST are representative of the field and demonstrates our approach to validating the failure mechanisms induced.

14 SOLAR ENERGY↗

Flow Sensor Test Article (F-STAr) (Design and Fabrication Status Report)

The Flow Sensor Test Article (F-STAr) is a test article currently under construction for the Mechanisms Engineering Test Loop (METL). F-STAr was designed to provide high sodium flowrate capabilities for sensor calibration, component testing, and fluid studies. Figure 1 shows two solid model views of the new test article. F-STAr includes a high-capacity pump that can provide a nominal flowrate of 120 GPM; a test section support structure that can accommodate a wide array of sub-test articles and their instrumentation; and finally, a heating and cooling system to aid in controlling the testing environment. Initially, F-STAr will be configured to test liquid metal flow sensors, specifically field shift sensors like the Eddy Current Flow Sensors (ECFS) based on the RDT C4-7T standard. To test these sensors, two test sections were designed that attempt to model Sodium Fast Reactor (SFR) outlet conditions. Figure 2 shows models of the “Full-Scaled Test Section” (FSTS) that represents a generic SFR fuel handling socket and a “Pseudo-Scaled Test Section” (PSTS) that represents a generic array of scaled fuel handling sockets. While F-STAr will be configured to test ECFS’s, it can also be outfitted to meet other experimental needs. For example, F-STAr could be setup with a test section that includes a fluidic diode or a component test investigating the performance of hydrodynamic bearings. Other test sections include studies of sodium thermal hydraulics like thermal striping. Overall, F-STAr is a flexible test article designed to accommodate many needs. This report will provide a status update on the design and construction of F-STAr. Manufacturing of all components has commenced, and several components have already been completed. These components include the pump and test section assembly stand. Other components, such as the heater, have been completed but were rejected due to the vendor not meeting the requirements of the purchase order. Lastly, the submersible flowmeter and main flange components are under construction, and their status will be reviewed in this report. Overall, most of the F-STAr components and parts will be completed by the end of September 2022.

42 ENGINEERING↗

STANDARDS-BASED TECHNOLOGIES FOR EXCHANGING FATIGUE TEST DATA

Fatigue testing campaigns are a common feature in the design and operation of advanced engineering systems in the aerospace and power generation sectors. The resulting data are typically of a high inherent technical and financial value. Presently, these data are typically transferred between departments and companies by way of ad-hoc solutions reliant on obsolete or proprietary technologies, including CSV files, MS Excel® files, and PDFs. In these circumstances there is significant potential for data loss, inconsistency, and error. To address these shortcomings, there is a need for a systematic means of transferring data between different digital systems. With this in mind, a series of CEN Workshops on engineering materials data have taken place with a view to developing technologies for representing and exchanging engineering materials data. Most recently, a CEN Workshop on the topic of fatigue test data has delivered data formats derived from the ISO 12106 standard for axial strain-controlled fatigue testing. This paper describes the methodology for developing the data formats and demonstrates their use in the scope of the INCEFA PLUS project on increasing safety in nuclear power plants by covering gaps in environmental fatigue assessment.

Austin, Timothy↗

Procedure for Performing Security Camera Optical Performance Analysis Tests

Digital security camera technologies proliferate the security marketplace with manufacturers extoling the functions, features, specifications and virtues of their cameras. A process to comparatively analyze security camera technologies using international camera analysis standards and methods provides a defensible means to assess camera image quality on a technically comparable basis. The procedures in this document use ISO standard camera test charts and camera image analysis software to perform test chart image analysis for comparative camera assessment. Step-by-step procedures for acquiring test chart images in the laboratory and producing analysis data using analysis software GUI controls and interfaces for comparative analysis of security camera image quality are detailed in this document. The procedures have been validated through the test and analysis of fixed box and 180 degree field of view multi-imager cameras as well as, fixed and varifocal lenses and analog-to-digital video encoder image quality performance attributes.

42 ENGINEERING↗

Towards grounding nuclear physics in QCD

Exascale computing could soon enable a predictive theory of nuclear structure and reactions rooted in the Standard Model, with quantifiable and systematically improvable uncertainties. Such a predictive theory will help exploit experiments that use nucleons and nuclei as laboratories for testing the Standard Model and its limitations. Examples include direct dark matter detection, neutrinoless double beta decay, and searches for permanent electric dipole moments of the neutron and atoms. It will also help connect QCD to the properties of cold neutron stars and hot supernova cores. We discuss how a quantitative bridge between QCD and the properties of nuclei and nuclear matter will require a synthesis of lattice QCD (especially as applied to two- and three- nucleon interactions), effective field theory, and ab initio methods for solving the nuclear many-body problem. While there are significant challenges that must be addressed in developing this triad of theoretical tools, the rapid advance of computing is accelerating progress. In particular, we focus this review on the anticipated advances from lattice QCD and how these advances will impact few-body effective theories of nuclear physics by providing critical input, such as constraints on unknown low-energy constants of the effective (field) theories. We also review particular challenges that must be overcome for the successful application of lattice QCD for low-energy nuclear physics. We describe progress in developing few-body effective (field) theories of nuclear physics, with an emphasis on HOBET, a non-relativistic effective theory of nuclear physics, which is less common in the literature. We use the examples of neutrinoless double beta decay and the nuclear-matter equation of state to illustrate how the coupling of lattice QCD to effective theory might impact our understanding of symmetries and exotic astrophysical environments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transitioning from Cobalt-60 to X-Ray or E-Beam for Medical Sterilization: Filling Data and Education Gaps

The Office of Radiological Security (ORS) within the U.S. DOE’s National Nuclear Security Administration (NNSA) is charged to “work with government, law enforcement, and businesses across the globe to protect radioactive sources used for medical, research, and commercial purposes; remove and dispose of disused radioactive sources; and reduce the global reliance on high activity radioactive sources through the promotion of viable non-radioisotopic alternative technologies.” In this effort, the NNSA/ORS, along with the Office of Defense Nuclear Nonproliferation R&D, has been working with government and private entities that utilize gamma-ray irradiators in areas that include blood irradiation, radiotherapy, biology research, well logging, and radiation processing to consider alternative technologies that do not depend upon radioactive materials. In the medical device industry, nearly 50% of products are sterilized with ethylene oxide, 40.5% with cobalt-60 gamma-rays, 4.5% with electron-beam (e-beam), and <1% with X-ray.(1,2) The cobalt-60 irradiation facilities use an estimated 150 MCi of isotope to sterilize approximately 200 million cubic feet of product annually.(3) Due to growing safety regulations governing cobalt-60 use, continued advancements in e-beam and X-ray accelerator technology, and the greater irradiation durations and costs for cobalt-60 irradiation compared to e-beam and X-ray, switching to these non-radionuclide modalities is increasingly economically competitive. However, this breakdown of 40.5% cobalt-60 and 5.5% accelerator for product sterilization illustrates the difficulty that market forces and industry players have had in overcoming barriers in transitioning to non-nuclide alternatives. Besides those associated with construction of new e-beam and X-ray facilities, significant financial and regulatory obstacles are also associated with the irradiation and comprehensive testing of product constituent polymers and elastomers. The standards associated with product material performance testing are the Association for the Advancement of Medical Instrumentation (AAMI) Technical Information Report 17 (TIR 17), and its referenced American Society for Testing and Materials (ASTM) polymer testing standards. In the study now underway, and the subject of this article, the NNSA/ORS provided R&D funding to the Pacific Northwest National Laboratory (PNNL) in partnership with university researchers, leading medical product manufacturers, accelerator manufacturers, and contract sterilizers. The resulting Team Nablo (in memory of Sam Nablo) includes individuals representing PNNL, Becton Dickinson (BD), Johnson & Johnson, Stryker, Texas A&M University (TAMU), Steri-Tek, Mevex, Ion Beam Applications (IBA), and Sterigenics. The goals of this study are to 1) Identify specific polymer and/or elastomer-based medical products that are currently sterilized with gamma-rays, and for which there are data gaps and would be of greatest industry impact, 2) Work with relevant ASTM subcommittees for guidance and for potential standard revision, 3) Work with an appropriate Food & Drug Administration (FDA) office for potential collaboration on a guidance document for device manufacturers, 4) Measure the physical effects that product materials exhibit when they are given sterilization-level radiation doses from cobalt-60, e-beam or X-ray, and determine whether these effects would preclude the use of e-beam or X-ray for sterilization, 5) Communicate the resulting scientific datasets and findings via industry conferences, peer-reviewed journals, and relevant trade magazines, and 6) Post the resulting datasets on a publicly accessible website, which can be built on in future years. The end objective is to identify technical barriers preventing the adoption of X-ray and e-beam technologies, and share the results to encourage X-ray and e-beam adoption where feasible.

sterilization, alternate technologies, gamma, X-ra↗

Extending the range of constant strain rate nanoindentation testing

Constant strain rate nanoindentation hardness measurements at high sustained strain rates cannot be made in conventional nanoindentation testing systems using the commonly employed continuous stiffness measurement technique (CSM) because of the “plasticity error” recently reported by Merle et al. [Acta Mater.134, 167 (2017)]. To circumvent this problem, here we explore an alternative testing and analysis procedure based on quasi-static loading and an independent knowledge of the Young's modulus, which is easily obtained by standard nanoindentation testing. In theory, the method applies to any indentation strain rate, but in practice, an upper limit on the rate arises from hardware limitations in the testing system. The new methodology is developed and applied to measurements made with an iMicro nanoindenter (KLA, Inc.), in which strain rates up to 100 s -1 were successfully achieved. The origins of the hardware limitations are documented and discussed.

36 MATERIALS SCIENCE↗

Installation of TVC Actuators in a Two Axis Inertial Load Simulator Test Stand

This paper is about the installation of Space Shuttle Main Engines (SSME) actuators in the new Two Axis Inertial Load Simulator (ILS) at MSFC. The new test stand will support the core stage of the Space Launch System (SLS). Because of the unique geometry of the new test stand standard actuator installation procedures will not work. I have been asked to develop a design on how to install the actuators into the new test stand. After speaking with the engineers and technicians I have created a possible design solution. Using Pro Engineer design software and running my own stress calculations I have proven my design is feasible. I have learned how to calculate the stresses my design will see from this task. From the calculations I have learned I have over built the apparatus. I have also expanded my knowledge of Pro Engineer and was able to create a model of my idea.

Dziubanek, Adam↗

NASA Glenn's Acoustical Testing Laboratory Awarded Accreditation by the National Voluntary Laboratory Accreditation Program

NASA Glenn Research Center's Acoustical Testing Laboratory (ATL) provides a comprehensive array of acoustical testing services, including sound pressure level, sound intensity level, and sound-power-level testing per International Standards Organization (ISO)1 3744. Since its establishment in September 2000, the ATL has provided acoustic emission testing and noise control services for a variety of customers, particularly microgravity space flight hardware that must meet International Space Station acoustic emission requirements. The ATL consists of a 23- by 27- by 20-ft (height) convertible hemi/anechoic test chamber and a separate sound-attenuating test support enclosure. The ATL employs a personal-computer-based data acquisition system that provides up to 26 channels of simultaneous data acquisition with real-time analysis (ref. 4). Specialized diagnostic tools, including a scanning sound-intensity system, allow the ATL's technical staff to support its clients' aggressive low-noise design efforts to meet the space station's acoustic emission requirement. From its inception, the ATL has pursued the goal of developing a comprehensive ISO 17025-compliant quality program that would incorporate Glenn's existing ISO 9000 quality system policies as well as ATL-specific technical policies and procedures. In March 2003, the ATL quality program was awarded accreditation by the National Voluntary Laboratory Accreditation Program (NVLAP) for sound-power-level testing in accordance with ISO 3744. The NVLAP program is administered by the National Institutes of Standards and Technology (NIST) of the U.S. Department of Commerce and provides third-party accreditation for testing and calibration laboratories. There are currently 24 NVLAP-accredited acoustical testing laboratories in the United States. NVLAP accreditation covering one or more specific testing procedures conducted in accordance with established test standards is awarded upon successful completion of an intensive onsite assessment that includes proficiency testing and documentation review. The ATL NVLAP accreditation currently applies specifically to its ISO 3744 soundpower- level determination procedure (see the photograph) and supporting ISO 17025 quality system, although all ATL operations are conducted in accordance with its quality system. The ATL staff is currently developing additional procedures to adapt this quality system to the testing of space flight hardware in accordance with International Space Station acoustic emission requirements.<

Akers, James C.↗

Preparation of calibrated test packages for particle impact noise detection

A standard calibration method for any particle impact noise detection (PIND) test system used to detect loose particles responsible for failures in hybrid circuits was developed along with a procedure for preparing PIND standard test devices. Hybrid packages were seeded with a single gold ball, hermetically sealed, leak tested, and PIND tested. Conclusions are presented.

Source record↗

Experimental determination of pure rotary stability derivatives using curved and rolling flow wind tunnel

The technique of using a curved and rolling flow wind tunnel to extract pure rotary stability derivatives is presented. Descriptions of the curved flow and the rolling flow test sections of the Virginia Tech Stability Wind Tunnel are given including methods for obtaining the proper velocity profiles and correcting the data acquired. Results of testing current fighter configurations in this facility are presented with particular attention given to comparing pure rotary derivatives with combined rotary and unsteady derivatives obtained by standard oscillation tests. Also the effect of curved and rolling flow on lateral static stability derivatives is examined.

Lutze, F. H.↗

High temperature cyclic oxidation furnace testing at NASA Lewis Research Center

A standardized method of testing the cyclic oxidation resistance of various alloys in static air to 1200 C was developed and is routinely used at NASA Lewis Research Center. Test samples are automatically raised and lowered into a resistance wound furnace for a series of fixed interval heating and cooling cycles. Spall catchers collect the accumulated spall from each sample. The samples are weighed intermittently to generate specific weight change/time data. At various test times the samples and the accumulated spall are analyzed by X-ray diffraction. A computer program uses this gravimetric and X-ray data as input to print out the oxidation curves and specific weight change/time and X-ray results in a published format, organizes, and indexes the data. So far, several hundred Fe, Ni, and Co base alloys were tested using this same basic procedure and results form the basis of a series of cyclic oxidation handbooks to be published by NASA. Such specific weight change/time data were used to estimate the oxidative metal consumption by several computer modeling techniques to rank alloys and for use in life testing estimates.

Barrett, C. A.↗

High temperature cyclic oxidation furnace testing at NASA Lewis Research Center

A standardized method of testing the cyclic oxidation resistance of various alloys in static air up to 1200 C has been developed and routinely used at the NASA Lewis Research Center. Test samples are automatically raised and lowered into a resistance wound furnace for a series of fixed-interval heating and cooling cycles. Spall catchers collect the accumulated spall from each sample. The samples are weighed intermittently to generate specific weight change with time data. At various test times the samples and the accumulated spall are analyzed by X-ray diffraction. A computer program is used to print out the specific weight change versus time data and the X-ray data in tabular form and to plot the specific weight change versus time data in a publishable format. The data are also organized and indexed. So far several hundred Fe-, Ni-, and Co-base alloys have been tested using this basic procedure and will form the basis of a series of cyclic oxidation handbooks to be published by NASA. Such specific weight change/time data have been used to estimate the oxidative metal consumption by several computer modeling techniques both to rank alloys and to estimate life.

Barrett, C. A.↗

Electrostatic testing of thin plastic materials

Ten thin plastic materials (Velostat, RCAS 1200, Llumalloy, Herculite 80, RCAS 2400, Wrightlon 7000, PVC, Aclar 22A, Mylar, and Polyethylene) were tested for electrostatic properties by four different devices: (1) The static decay meter, (2) the manual triboelectric testing device, (3) the robotic triboelectric testing device, and (4) the resistivity measurement adapter device. The static decay meter measured the electrostatic decay rates in accordance with the Federal Test Method Standard 101B, Method 4046. The manual and the robotic triboelectric devices measured the triboelectric generated peak voltages and the five-second decay voltages in accordance with the criteria for acceptance standards at Kennedy Space Center. The resistivity measurement adapter measured the surface resistivity of each material. An analysis was made to correlate the data among the four testing devices. For the material tested the pass/fail results were compared for the 4046 method and the triboelectric testing devices. For the limited number of materials tested, the relationship between decay rate and surface resistivity was investigated as well as the relationship between triboelectric peak voltage and surface resistivity.

Skinner, S. Ballou↗

Performance Measurement of Advanced Stirling Convertors (ASC-E3)

NASA Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance testing data of the Advanced Stirling Convertor (ASC). The latest version of the ASC (ASC-E3, to represent the third cycle of engineering model test hardware) is of a design identical to the forthcoming flight convertors. For this generation of hardware, a joint Sunpower and GRC effort was initiated to improve and standardize the test support hardware. After this effort was completed, the first pair of ASC-E3 units was produced by Sunpower and then delivered to GRC in December 2012. GRC has begun operation of these units. This process included performance verification, which examined the data from various tests to validate the convertor performance to the product specification. Other tests included detailed performance mapping that encompassed the wide range of operating conditions that will exist during a mission. These convertors were then transferred to Lockheed Martin for controller checkout testing. The results of this latest convertor performance verification activity are summarized here.

Stirling Cycle↗