Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Gamma Spectrometry Examination of the AGR-3/4 Irradiation

The results from gamma spectrometry examination of the different components from the combined third and fourth U.S. Advanced Gas Reactor (AGR) TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail (DTF) particles surrounded by inner and outer graphite and/or graphitic matrix rings and a graphite sink ring were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (i.e., Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. The inner and outer rings were also examined by gamma spectrometry to evaluate the total fission product inventory of the rings, and gamma emission computed tomography (GECT) was used to investigate the spatial distribution of gamma-emitting fission products within the rings. This report focuses on results obtained via the Precision Gamma Scanner (PGS) for the compacts and inner and outer rings. These non-destructive gamma measurements are currently being compared to recent destructive measurements of spatial fission product distributions in the rings and to predictions made via mathematical modeling. A separate report discusses the entire AGR-3/4 fission product mass balance for all irradiation capsule components including the inner and outer rings, graphite sink rings, capsule spacers, capsule foils, through tubes, and felts. This report is similar to the conference proceedings: Harp, J.M., Demkowicz, P.A., and Stempien, J.D., “Initial gamma spectrometry examination of the AGR-3/4 irradiation,” International Topical Meeting High Temperature Reactor Technology (HTR 2016), Las Vegas, NV, USA, November 2016, Paper HTR2016-18593, but it has been updated to reflect all the data that has been collected on AGR-3/4 using PGS. The Appendices contain extensive data from the collected gamma spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Further Development of an ISOCS - based Advanced In Situ Gamma Spectrometry Services Tool for Waste Measurements - 17452

Canberra's In Situ Object Counting System is an established tool used for gamma spectrometry allowing a physical representation of complex geometries and mathematical calculation of the calibration function while avoiding the need for radioisotope standards. The ISOCS Uncertainty Estimator tool can be used to calculate defensible systematic calibration uncertainties. However the uncertainties depend on knowledge of the properties of the item being measured and for poorly characterized materials these can be large, often leading to large costs for waste sentencing. An ISOCS-based advanced in-situ gamma spectrometry services tool has been developed to reduce those uncertainties. This system is based on generating and comparing a range of candidate geometry models that yield figures of merit indicative of improved consistency between modelled data and available diverse measurement data. The approach and results of initial performance testing have previously been published, demonstrating an analysis procedure and enhanced accuracy for measurement of a low density 200 litre waste drum, based on measurements with known sources placed at different positions. It was shown how the accuracy of assay of Am-241 in a light matrix can be significantly improved. Further analysis has now been performed, with reference to measurements of a second drum, containing a standard matrix of higher density, and with a multiple radionuclide line source (Ba-133, Cs-137, Eu-152 and Am-241). These measurements represent a more challenging waste assay scenario, corresponding to potentially much larger assay uncertainties. Our results show how the assay uncertainty can be reduced, by careful application of AIGS, from relative values of the order of 100% to a few 10's of %. Furthermore, we demonstrate, through extended analysis of the test drum data, how an AIGS measurement program can be optimized to reduce the number of required measurement positions substantially. This paper describes these new results with comment on their importance and potential application for real waste assay projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Indexing Permafrost Soil Organic Matter Degradation Using High-Resolution Mass Spectrometry

Microbial degradation of soil organic matter (SOM) is a key process for terrestrial carbon cycling, although the molecular details of these transformations remain unclear. This study reports the application of ultrahigh resolution mass spectrometry to profile the molecular composition of SOM and its degradation during a simulated warming experiment. A soil sample, collected near Barrow, Alaska, USA, was subjected to a 40-day incubation under anoxic conditions and analyzed before and after the incubation to determine changes of SOM composition. A CHO index based on molecular C, H, and O data was utilized to codify SOM components according to their observed degradation potentials. Compounds with a CHO index score between –1 and 0 in a water-soluble fraction (WSF) demonstrated high degradation potential, with a highest shift of CHO index occurred in the N-containing group of compounds, while similar stoichiometries in a base-soluble fraction (BSF) did not. Additionally, compared with the classical H:C vs O:C van Krevelen diagram, CHO index allowed for direct visualization of the distribution of heteroatoms such as N in the identified SOM compounds. We demonstrate that CHO index is useful not only in characterizing arctic SOM at the molecular level but also enabling quantitative description of SOM degradation, thereby facilitating incorporation of the high resolution MS datasets to future mechanistic models of SOM degradation and prediction of greenhouse gas emissions.

Environmental Molecular Sciences Laboratory↗

Quantification of 85 Rb, 136 Ce, 142 Nd and 150 Nd Enriched Isotope Standards

Enriched isotope standards are required for routine nuclear fuel burnup and other radiochemical analyses. In 2017 Idaho National Laboratory (INL) generated isotope standard solutions containing enriched 85 Rb, 136 Ce, 142 Nd, and 150 Nd. Oxide and chloride forms of each enriched isotope were obtained from the Oak Ridge Isotope Production program, dissolved, and quantified by isotope dilution-multi collector mass spectrometry. Quantification of the isotope solutions was performed independently by two separate laboratories at INL: the Analytical Laboratory (AL) at the Material and Fuels Complex (MFC) and the Ultra-trace Analytical Laboratory (UAL) in Idaho Falls. Concentration measurement results for all solutions and 142 Nd isotope ratio values reported by both laboratories are in quantitative agreement with each other, while isotope ratio values reported for 150 Nd are observed to have an apparent ~0.8% bias between the results of each laboratory. Data for 85 Rb/ 87 Rb isotope ratio values for UAL TIMS measurements and AL MC-ICP-MS measurements are in quantitative agreement with each other, while those of UAL MC-ICP-MS are observed to be much higher due to the existence of unidentified polyatomic interferences in the 84-88 m/z range for this instrument. Concentration and isotope ratio values for these isotope tracer solutions, along with detailed description of the analytical and data analysis methods utilized, are reported herein.

07 ISOTOPE AND RADIATION SOURCES↗

Deducing the N- and O-glycosylation profile of the spike protein of novel coronavirus SARS-CoV-2

The current emergence of the novel coronavirus pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) demands the development of new therapeutic strategies to prevent rapid progress of mortalities. The coronavirus spike (S) protein, which facilitates viral attachment, entry and membrane fusion is heavily glycosylated and plays a critical role in the elicitation of the host immune response. The spike protein is comprised of two protein subunits (S1 and S2), which together possess 22 potential N-glycosylation sites. Herein, we report the glycosylation mapping on spike protein subunits S1 and S2 expressed on human cells through high-resolution mass spectrometry. We have characterized the quantitative N-glycosylation profile on spike protein and interestingly, observed unexpected O-glycosylation modifications on the receptor-binding domain of spike protein subunit S1. Even though O-glycosylation has been predicted on the spike protein of SARS-CoV-2, this is the first report of experimental data for both the site of O-glycosylation and identity of the O-glycans attached on the subunit S1. Our data on the N- and O-glycosylation are strengthened by extensive manual interpretation of each glycopeptide spectra in addition to using bioinformatics tools to confirm the complexity of glycosylation in the spike protein. Here, the elucidation of the glycan repertoire on the spike protein provides insights into the viral binding studies and more importantly, propels research toward the development of a suitable vaccine candidate.

59 BASIC BIOLOGICAL SCIENCES↗

Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) peak intensity normalization for complex mixture analyses

Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) is a preferred technique for analyzing complex organic mixtures. Currently, there is no consensus normalization approach, nor an objective method for selecting one, for quantitative analyses of FT-ICR-MS data. We investigate a method to evaluate and score the amount of bias various normalization approaches introduce into the data. We evaluate the ability of the Statistical Procedure for the Analysis of Normalization Strategies (SPANS) to guide selection of appropriate normalization approaches for two different FT-ICR-MS datasets. Further, we test the robustness of SPANS results to changes in SPANS parameter values and assess the impact of using various normalization approaches on downstream statistical analyses. The normalization approach identified by SPANS differed for the two datasets. Normalization methods impacted the statistical significance of peaks differently, underscoring the importance of carefully evaluating potential methods. More consistent SPANS scores resulted when at least 120 significant peaks are used, where larger sets of peaks were obtained by increasing the p-value threshold. Interestingly, we show that Total Sum Scaling and highest peak normalization, used in previous studies, underperformed relative to SPANS-recommended normalization approaches. While there is no single, best normalization method for all datasets, SPANS provides a mechanism to identify an appropriate normalization method for analyzing FT-ICR-MS data quantitatively. As a result, the number of peaks used in the background distributions of SPANS contributes more significantly to the reproducibility of results than the p-value thresholds used to obtain those peaks.

47 OTHER INSTRUMENTATION↗

Heavy Metal Atmospheric Deposition Study in Moscow Region, Russia

The air quality in north-eastern part of Moscow region was evaluated by trace metals atmospheric deposition using moss Pleurozium schreberi as bioindicator. Thirty six elements were determined in analyzed samples by Neutron activation analysis and Atomic absorption spectrometry. Principal component analysis was used to identify and characterize different pollution sources. Maps showing the geographical distribution of the factor scores were built using ArcGis software. Median values of the elements studied were compared with data obtained for other regions in Russia. The present survey showed that industrial activity, thermal power plants and transport still have the largest anthropogenic impact on air pollution in studied region.

54 ENVIRONMENTAL SCIENCES↗

Updated evaluation of potential ultralow Q -value β -decay candidates

“Ultralow” Q-value β decays are referred to as such due to their low decay energies of less than ≈1 keV. Such a low energy decay is possible when the parent nucleus decays to an excited state in the daughter, with an energy close to that of the Q value. These decays are of interest as potential new candidates for neutrino mass determination experiments and as a testing ground for studies of atomic interference effects in the nuclear decay process. In this paper, we provide an updated evaluation of atomic mass data and nuclear energy-level data to identify potential ultralow Q-value β decay candidates. For many of these candidates, more precise and accurate atomic mass data is needed to determine if the Q value of the potential ultralow decay branch is energetically allowed and in fact ultralow. Furthermore, the relevant precise atomic mass measurements can be achieved via Penning trap mass spectrometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nanofiltration Results: Membrane Removal of Calcium, Magnesium, Sodium, Silica, Lithium, Chlorine, and Sulfate from Simulated Geothermal Brines

Results from a nanofiltration study utilizing simulated geothermal brines. The data includes a PDF documenting the process used to remove Calcium, Magnesium, Sodium, Silica, Lithium, Chlorine, and Sulfate from simulated geothermal brines. Three different membranes were evaluated. The results were analyzed using inductively coupled plasma mass spectrometry (ICP-MS).

15 GEOTHERMAL ENERGY↗

Release of volatiles from possible Martian analogs

Viking data suggest the presence of volatile-rich materials in the Martian regolith. The thermal stabilities of mineral phases and their volatile release profiles were studied in detail in our laboratory. Thermal analysis, combined with mass spectrometry, was applied to the study of the behavior of carbonates, sulfates, hydrates, and clays. The results indicate that these techniques are useful in the preliminary mineralogical characterizations of volatile-rich minerals. However, our results also indicate that great care must be taken in the incorporation into planetary probes of such methods as hearing rates, pressure, composition of atmospheres, grain size, etc., because these factors effect volatile release.

Kotra, R. K.↗

Clean quartz matters for cosmogenic nuclide analyses: An exploration of the importance of sample purity using the CRONUS-N reference material

We report reference materials are key for assessing inter-laboratory variability and measurement quality, and for placing analytical uncertainty bounds on sample analyses. Here, we investigate four years of data resulting from repeated processing of the CRONUS-N reference material for cosmogenic 10 Be and 26 Al analyses. At University of Vermont, we prepared a CRONUS-N aliquot with most of our sample batches from 2013 to 2017; these reference material samples were then distributed to four different accelerator mass spectrometry facilities, yielding 73 10 Be analyses and 58 26 Al analyses. We determine CRONUS-N 10 Be concentrations of (2.26 ± 0.14) x 10 5 atoms g -1 (n = 73, mean, 1 SD) and 26 Al concentrations of (1.00 ± 0.08) x 10 6 atoms g -1 (n = 58, mean, 1 SD). We find a reproducibility of 6.3% for 10 Be and 7.7% for 26 Al (relative standard deviations). We also document highly variable 27 Al and Mg concentrations and a 10 Be dispersion twice as large as the mean AMS analytic uncertainty. Analyses of the CRONUS-N material with and without density separation demonstrate that non-quartz minerals are present in the material and have a large impact on measured concentrations of 27 Al, 10 Be, and impurities; these non-quartz minerals represent only a very small portion of the total mass (0.6–0.8%) but have a disproportionally large effect on the resulting data. Our results highlight the importance of completely removing all non-quartz mineral phases from samples prior to Be/Al extraction for the determination of in situ cosmogenic 10 Be and 26 Al concentrations.

58 GEOSCIENCES↗

Structural Analysis of 23S rRNA Methylating Enzyme Cfr Reveals RNA-Binding Determinants for Methylation Regiospecificity and Antibiotic Resistance

The 23S rRNA methylating enzyme Cfr, found in pathogens including Staphylococcus aureus, Clostridium difficile, Escherichia coli, and Klebsiella pneumoniae, confers resistance to phenicols, lincosamides, oxazolidinones (including linezolid), pleuromutilins, and streptogramins A (the PhLOPS A phenotype). Cfr catalyzes methylation of the C8 position of the A2503 base in 23S rRNA, the recognition site of the above antibiotic classes. Along with the RlmN housekeeping enzyme, Cfr can also promote methylation of the C2 position of the same base. The molecular and structural basis of Cfr’s dual substrate specificity is not known, which hinders our ability to design Cfr-targeting inhibitors necessary to curb PhLOPS A resistance. Here, we present the first crystal structure of Cfr and a detailed analysis of its possible interactions with rRNA. Using structure-guided mutagenesis, mass spectrometry analysis of in cellulo 23S rRNA methylated species, and in cellulo resistance studies, we identify the key amino acids essential for Cfr methylation and multidrug resistance activity. In particular, we found that Cfr’s Q329 residue is important for C8- specific methylation. These data provide a framework for further studies of the biochemistry, structure, and inhibition of this important resistance determinant.

AlphaFold↗

Spectrometry of Pasture Condition and Biogeochemistry in the Central Amazon

Regional analyses of Amazon cattle pasture biogeochemistry are difficult due to the complexity of human, edaphic, biotic and climatic factors and persistent cloud cover in satellite observations. We developed a method to estimate key biophysical properties of Amazon pastures using hyperspectral reflectance data and photon transport inverse modeling. Remote estimates of live and senescent biomass were strongly correlated with plant-available forms of soil phosphorus and calcium. These results provide a basis for monitoring pasture condition and biogeochemistry in the Amazon Basin using spaceborne hyperspectral sensors.

Asner, Gregory P.↗

Chemical Characterization of Crude Petroleum Using Nanospray Desorption Electrospray Ionization Coupled with High-Resolution Mass Spectrometry

Nanospray desorption electrospray ionization (nano-DESI) combined with high-resolution mass spectrometry was used for the first time for the analysis of liquid petroleum crude oil samples. The analysis was performed in both positive and negative ionization modes using three solvents one of which (acetonitrile/toluene mixture) is commonly used in petroleomics studies while two other polar solvents (acetonitrile/water and methanol/water mixtures) are generally not compatible with petroleum characterization using mass spectrometry. The results demonstrate that nano-DESI analysis efficiently ionizes petroleum constituents soluble in a particular solvent. When acetonitrile/toluene is used as a solvent, nano-DESI generates electrospray-like spectra. In contrast, strikingly different spectra were obtained using acetonitrile/water and methanol/water. Comparison with the literature data indicates that these solvents selectively extract water-soluble constituents of the crude oil. Water-soluble compounds are predominantly observed as sodium adducts in nano-DESI spectra indicating that addition of sodium to the solvent may be a viable approach for efficient ionization of water-soluble crude oil constituents. Nano-DESI enables rapid screening of different classes of compounds in crude oil samples using solvents that are rarely used for petroleum characterization.

02 PETROLEUM↗

An effective QWBA/UHPLC-MS/tissue punch approach: solving a pharmacokinetic issue via quantitative Met-ID

Methods to provide absolute quantitation of the administered drug and corresponding metabolites in tissue in a spatially resolved manner is a challenging but much needed necessity in pharmaceutical research. Quantitative whole-body autoradiography (QWBA) after a single-dose intravenous (3 mg/kg) and extravascular (30 mg/kg) administrations of an in vitro metabolically stable test compound (structure not reported here) indicated quick tissue distribution and excretion. Good bioavailability and short in vivo half-lives were determined formerly for the same test compound. For closing gaps in the understanding of pharmacokinetic data and in vitro results, radioactive hot spots on whole-body tissue sections had been profiled. Punches from selected tissue regions containing high radioactivity in the tissue sections previously analyzed by QWBA were extracted by a highly organic solvent and analyzed without any consecutive sample preparation step, applying ultra high performance liquid chromatography-mass spectrometry (UHPLC-MS) and off-line radioanalysis to maximize signal levels for metabolite identification and profiling. The analysis revealed that the test compound was metabolized intensively by phase I reactions in vivo and the metabolites formed were excreted in bile and in urine. The predominant metabolites showed abundant signal intensities both by MS and by radioanalysis but the MS signal intensities generally underestimated the real abundances of metabolites relative to the unchanged drug. In this work we illustrate that maximizing the sensitivity of tissue punch radioanalysis and the combination with UHPLC-MS leads to a better insight of pharmacokinetic processes by providing quantitative data with high molecular selectivity.

60 APPLIED LIFE SCIENCES↗

Exploration of Electrochemical Reactions at Organic–Inorganic Halide Perovskite Interfaces via Machine Learning in In Situ Time-of-Flight Secondary Ion Mass Spectrometry

The instability of hybrid organic–inorganic perovskite (HOIP) devices is one of the significant challenges preventing commercialization. Exploring these phenomena is severely limited by the complexity of the intrinsic electrochemistry of HOIPs, the presence of multiple volatile and mobile ionic species, and the possible role of environmentally induced reactions at surfaces and triple-phase junctions. Here, in situ studies of the electrochemistry of methylammonium lead bromide perovskite with the Au electrode interface are reported via light- and voltage-dependent time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging of lateral perovskite heterostructures. While ToF-SIMS allows for the visualization of the chemical composition along the surface and its evolution with light and electrical bias, the interpretation of the multidimensional data obtained is often limited due to strong correlations between chemical signatures and the need to track multiple peaks at once. Here, a machine learning workflow combining the Hough transform and non-negative matrix factorization and no-negative tensor decomposition is developed to avoid this limitation and extract salient features of associated chemical changes and to separate the light- and voltage-dependent dynamics. Finally, combining these in situ characterizations and the machine learning workflow provides comprehensive information on the chemical nature of moving species, ion accumulation, and interfacial electrochemical reactions in HOIP devices.

36 MATERIALS SCIENCE↗

Chapter 14: Dynamic Flux Analysis: An Experimental Approach of Fluxomics

Metabolic flux analysis represents an essential perspective to understand cellular physiology and offers quantitative information to guide pathway engineering. A valuable approach for experimental elucidation of metabolic flux is dynamic flux analysis, which estimates the relative or absolute flow rates through a series of metabolic intermediates in a given pathway. It is based on kinetic isotope labeling experiments, liquid chromatography-mass spectrometry (LC-MS), and computational analysis that relate kinetic isotope trajectories of metabolites to pathway activity. Herein, we illustrate the mathematic principles underlying the dynamic flux analysis and mainly focus on describing the experimental procedures for data generation. This protocol is exemplified using cyanobacterial metabolism as an example, for which reliable labeling data for central carbon metabolites can be acquired quantitatively. This protocol is applicable to other microbial systems as well and can be readily adapted to address different metabolic processes.

BASIC BIOLOGICAL SCIENCES↗

Identification and Characterization of Herbicide Penoxsulam Transformation Products in Aqueous Media by UPLC-QTOF-MS

Photodegradation is an important non-biodegradation process of pesticide degradation in aquatic environments. In this study, the effect of different forms of nitrogen on the photodegradation kinetics of penoxsulam was investigated. The photodegradation of penoxsulam was accelerated by NO{sup 3−} and NO{sup 2−} but was not affected by NH{sup 4+}. Ultra-high-performance liquid chromatography coupled with time-of-flight mass spectrometry was used to separate and identify the transformation products (TPs)converted by photodegradation of penoxsulam in an aqueous solution under UV–Vis (290–800 nm) irradiation. Seven major transformation products were identified based on mass spectral data. The structure was determined by elemental composition calculations, comparison of structural analogs, and existing literature. The main pathways of photodegradation were found to be sulfonamide bond cleavage, rearrangement, triazole ring cleavage, and hydroxylation. These findings are critical to elucidate the environmental fate of penoxsulam in aquatic ecosystems and provide a basis for further environmental risk assessment.

54 ENVIRONMENTAL SCIENCES↗