Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Deep Reinforcement Learning for Distribution System Restoration Using Distributed Energy Resources and Tie-Switches

Distributed energy resources (DERs), such as solar PVs and energy storage, can be used to restore distribution system critical loads after the extreme weather events to increase grid resilience. However, coordinating multiple DERs together with tie-switches for multi-step restoration process under renewable uncertainty is challenging. This paper proposes a deep reinforcement learning to control discrete actions of switching on/off tie switches and DERs for critical load restoration. The restoration problem is first cast into the Markov decision process suitable for DRL. Then, the original soft actor critic (SAC) method for continuous actions has been extended to handle discrete and continuous actions. Numerical comparison results with other stochastic optimization-based approaches on the modified IEEE 33-bus system show that the proposed method can achieve fast critical load restoration in the presence of substation power outage while maintaining system voltage limit throughout the restoration process.

active distribution systems↗

Optimal Control of SOEC-Based Hydrogen Production Systems for Demand Response Using Deep Reinforcement Learning in Smart Grids

Solid oxide electrolysis cell (SOEC) hydrogen production technology can range in size from small, appliance-size equipment to large-scale, central production facilities that can be tied directly to renewable or non-greenhouse-gas-emitting forms of electricity production, making it an ideal resource for demand response (DR). The SOEC hydrogen production system is a complex integrated system that encompasses fluid dynamics, electrical dynamics, and electrochemical and thermal dynamics, all of which involve non-linearity and non-convexity. Proper control of the SOEC hydrogen production system is crucial to enable its participation in the DR program. Here, to overcome the difficulty of designing an explicit control law for such nonlinear systems with nonconvex optimization features in DR applications, deep reinforcement learning (DRL) is explored to achieve the optimal control of the SOEC system for DR participation. Specifically, a twin delayed deterministic policy gradient (TD3) control framework is applied to achieve optimal response performance during DR events by considering power tracking error and hydrogen production efficiency with a suitable reward function. Two case studies with grid connections for tracking different DR commands were investigated. The first case study involved operating conditions reaching the boundaries, while the second involved operating conditions within the boundaries. The results showed that the proposed DRL-based control for SOEC can track the DR signal in a timely manner while maintaining high energy efficiency.

08 HYDROGEN↗

Investigation of the Cyanothece nitrogenase cluster in Synechocystis : a blueprint for engineering nitrogen-fixing photoautotrophs

ABSTRACT The nitrogenase gene cluster of unicellular diazotrophic cyanobacteria, such asCyanothece, is frequently selected by nature for nitrogen-fixing partnerships with eukaryotic phototrophs. The essential cluster components that confer an advantage in such partnerships remain underexplored. To use this cluster for the development of synthetic, phototrophic nitrogen-fixing systems, a thorough and systematic analysis of its constituent genes is necessary. An initial effort to assess the possibility of engineering this cluster into non-diazotrophic phototrophs led to the generation of aSynechocystis6803 strain with significant nitrogenase activity. In the current study, a refactoring approach was taken to determine the dispensability of the non-structural genes in the cluster and define a minimal gene set for constructing a functional nitrogenase for phototrophs. Using a bottom-up strategy, thenifgenes fromCyanothece51142 were re-organized to form new operons. The genes were then seamlessly removed to determine their essentiality in the nitrogen fixation process. We demonstrate that besides the structural genesnifHDK,nifBSUENPVZTXW, as well ashesAB, are important for optimal nitrogenase function in a phototroph. We also show that optimal expression of these genes is crucial for efficient nitrogenase activity. Our findings provide a solid foundation for generating synthetic systems that will facilitate solar-powered conversion of atmospheric nitrogen into nitrogen-rich compounds, a stride toward a greener world. IMPORTANCE Integrating nitrogen fixation genes into various photosynthetic organisms is an exciting strategy for converting atmospheric nitrogen into nitrogen-rich products in a green and energy-efficient way. In order to facilitate this process, it is essential that we understand the fundamentals of the functioning of a prokaryotic nitrogen-fixing machinery in a non-diazotrophic, photoautotrophic cell. This study examines a nitrogenase gene cluster that has been naturally selected on multiple occasions for a nitrogen-fixing partnership by eukaryotic photoautotrophs and provides a basic blueprint for designing a photosynthetic organism with nitrogen-fixing ability.

Microbiology↗

Networked Microgrids Optimization

This project is mainly about the operation optimization of three networked microgrids (MG), including centralized optimization and distributed optimization. The alternating direction method of multipliers (ADMM) algorithm is used for distributed optimization. In the distribution network considered here, there is a Distribution Management system (DMS) as the system coordinator and several networked microgrids. In grid-connected mode, power could be imported or exported at the distribution substation bus according to the utility rate, and the exchanged power at point of common coupling (PCC) of any microgrid has a limitation. In islanded mode, the power imports/exports at the distribution substation are zero. In both grid-connected and islanded mode, the distribution substation is taken as a slack bus with fixed voltage magnitude.

Chen, Yang [Oak Ridge National Laboratory (ORNL), ↗

Responsible Adoption of Artificial Intelligence (AI) in Electric Grid Operations

The future of the grid will be powered by AI—or undermined by it. Artificial intelligence is rapidly reshaping grid operations, improving fault detection, forecasting accuracy, and real-time optimization. As AI systems move closer to operational decision loops, however, they introduce new consequence pathways: expanded attack surfaces, model integrity risks, regulatory exposure, and human-automation challenges. This talk presents a consequence-driven framework for deploying AI responsibly in the electric grid. Attendees will gain practical strategies to strengthen resilience, boost reliability, and deploy AI securely — ensuring the grid of the future is not only smarter but safer.

25 - ENERGY STORAGE↗

An economic assessment of behind-the-meter photovoltaics paired with batteries on the Hawaiian Islands.

Due to natural variability and uncertainty, the ever-increasing penetration of solar generation in Hawaii presents challenges to power grid operators to maintain reliable system operation. Demand response (DR) has the potential to be a cost-effective tool for Hawaii to reach its aggressive renewable energy goals while maintaining the reliability of power grids. The Hawaii Public Utilities Commission has approved the Hawaiian Electric Company's revised portfolio of DR programs. The companies have released a grid services purchase agreement and subscribed an initial tranche of load into their DR programs. This paper presents innovative analytical methods and comprehensive economic assessment for distributed photovoltaics (PV) paired with battery energy storage systems (BESSs) for two new DR programs, including fast frequency response and capacity grid service. Optimal dispatch and sizing methods are proposed for the paired system considering different tariff schedules and PV compensation programs across five islands. It was found that while the best resource configuration and potential economic benefits vary with tariff structure, a BESS paired with PV can be optimally dispatched to generate multiple value streams simultaneously. Compensation from DR programs is an important value stream to help increase the cost-effectiveness of the integrated system.

Battery energy storage system↗

GIS Supported Optimal Site Selection for Coastal Structure Integrated Wave Energy Converters: Preprint

There is an urgent need for adaptative engineering towards more resilient coastal communities, and Coastal Structure Integrated Wave Energy Converters (CSI-WECs) are a promising solution. CSI-WECs are wave energy converters (WECs) that are built into coastal protection structures, such as breakwaters. These devices provide the dual benefits of coastal protection and local energy production, and unlike other WECs, maximizing energy production is not always the main objective. CSI-WECs are located near the shore, where the wave resource is lower, thus site selection for these devices differs from the typical offshore WECs. Other attributes of a site that may be more important than wave power include existing coastal structures, port proximity, electric transmission line proximity, and location of disadvantaged communities. Geospatial information systems (GIS) interfaces can be used to easily visualize geospatial data that represents these difference kinds of criteria important for the determination of optimal marine energy sites. Multi-Criteria Decision Analysis (MCDA) is a geospatial analysis method that allows for the evaluation of multiple, usually overlapping, criteria. This project applies GIS-based MCDA methods to two distinct case studies in Puerto Rico and California for CSI-WEC site selection. The two study sites contrast in terms of wave resource, coastal hazards, and local energy needs. This research demonstrates the utility of applying an MCDA framework within GIS to facilitate efficient site selection for devices with unique characteristics in different use cases.

coastal protection↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient Operation of Networked Community Microgrids with High Solar Penetration

This project, funded by the US Department of Energy’s Solar Energy Technologies Office (SETO), focused on the operation of microgrids as a coordinated network. The primary objective, which was successfully achieved, was to develop both control strategies and hardware solutions to support the resilient and efficient operation of networked microgrids with high solar penetration. The work was structured around the following four main tasks: • Development of distributed and scalable optimization algorithms for AC-coupled networked microgrids. • Design and implementation of a novel DC interconnection hardware to enable precise power exchange between microgrids. • Laboratory operational validation of the developed technologies using 480 V testbeds and commercially available hardware. • Field operational validation of the complete solution in Adjuntas, Puerto Rico, interconnecting two kW-scale, split-phase microgrids of Casa Pueblo’s microgrids. This project addressed multiple technical challenges across the domains of optimization, control, hardware interconnection, and protection. One of its key contributions was delivering tangible, real-world solutions for networking microgrids. In contrast to purely theoretical or simulation-based work, this project included full-scale hardware operational validation both in the lab and in the field. The work conducted as part of this project—in collaboration with the University of Puerto Rico; the University of Tennessee, Knoxville; the University of Central Florida; and Casa Pueblo—has advanced the state of the art in networked microgrids. Key contributions include the development of distributed control strategies, practical solutions for real-world implementation challenges, and the introduction of a novel DC interlink approach for microgrid interconnection. The project featured both laboratory and field validation using commercial off-the-shelf components. The field deployment successfully validated that a group of microgrids can operate in a coordinated manner, enabling precise power flow between systems and mutual support during extreme events. This project resulted in 15 journal publications and 15 conference papers; 5 graduate students and 15 undergraduate students were supported. The codes of distributed optimization and forecasting were made open-source through OSTI.gov for distributed optimization and forecasting. All the publications are available in the ORNL-hosted project landing page. The DC interlink with state-of-charge balancing control was operationally validated in Adjuntas by interconnecting two real-world, 240 V split-phase microgrids. To the best knowledge of the team, this represents the first operational validation of AC microgrids interconnected via DC-interlinks. As a culmination of this project, a follow-on grant was awarded to support the technology transfer of the distributed optimization framework to a commercial microgrid controller, Stellar Edge, developed by the California-based company New Sun Road.

14 SOLAR ENERGY↗

Flexible dynamic boundary microgrid operation considering network and load unbalances

Flexible microgrids with dynamic boundaries have recently been introduced in the literature. With the ability to reconfigure the topology of the microgrids dynamically through remotely controlled switches, flexible microgrids with dynamic boundaries can further improve the resiliency and energy efficiency of microgrids with distributed energy resources (DERs). This paper focuses on the optimal operation considering one of the predominant characteristics of microgrids and distribution systems – unbalanced networks and loads. In existing literature, balanced modeling of microgrids is more common due to its attractive simplicity. The three-phase power unbalance has not been considered as a constraint on the generation units in a microgrid. Further, negative sequence constraints have also been neglected. In this article, we propose a set of constraints that is specifically related to the capabilities of inverter interfaced resources to supply unbalanced current/power when the microgrid is islanded from the main distribution grid. We incorporate the new set of constraints into two optimization formulations leveraging two convex relaxations of the three-phase power flow equations: mixed-integer linear programming (MILP) and mixed-integer semidefinite programming (MISDP) that optimize the dispatch of controllable switches and DERs in the microgrid. The algorithms are then extended to networked microgrids with grid-forming sources. We test the algorithms on a realistic community microgrid model in Puerto Rico as well as standardized IEEE distribution test feeders. The testing results demonstrate the performance of the proposed algorithms. The MILP is fast and scalable, and the MISDP enforces the negative sequence voltage constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

First principles optimization of plutonium electrorefining

Herein this work presents a means of controlling plutonium electrorefining at a maximum rate regardless of equipment setup through the derivation of power supply current and potential governing equations for normal and off-normal operations. The governing equations are demonstrated by electrorefining surrogate materials. A simple linear current sweeping method was used to determine the maximum electrorefining current for the surrogate system. This method can be used to develop autonomous process optimization, real-time online processing monitoring, and real-time process endpoint detection. Ultimately, this research provides the foundation to optimize the liquid metal electrorefining rate to decrease the time needed to the physical limit for the process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Introduction to the Special Section on Control and Management of Electric Power Systems With High Shares of Inverter-Based Resources

The growing interest in the integration of variable renewable energy (VRE) and distributed energy resources (DER) on both policy and economic grounds is driving the transformation of electric power systems. The significant deployment of VRE and DER can effectively displace the conventional synchronous generator-based power plants that for decades have been the foundation for power system generation and stability in electric power systems. Inverter-based resources (IBRs) introduce a high-level of uncertainty, variability, and complexity into the operation of electric power networks, and the transformation to IBRs raises a wide range of technical questions and operational challenges. The optimal coordination and control of these resources requires greater interoperability and necessitates significant upgrades of grid automation, including real-time monitoring.

distributed power generation↗

A Comparative Study of Model Predictive Control and Optimal Causal Control for Heaving Point Absorbers

Efforts by various researchers in recent years to design simple causal control laws that can be applied to WEC devices suggest that these controllers can yield similar levels of energy output as those of more complex non-causal controllers. However, most studies were established without adequately considering device and power conversion system constraints which are relevant design drivers from a cost and economic point of view. It is therefore imperative to understand the benefits of MPC compared to causal control from a performance and constraint handling perspective. In this paper, we compare linear MPC to a casual controller that incorporates constraint handling to benchmark its performance on a one DoF heaving point absorber in a range of wave conditions. Our analysis demonstrates that MPC provides significant performance advantages compared to an optimized causal controller, particularly if significant constraints on device motion and/or forces are imposed. We further demonstrate that distinct control performance regions can be established that correlate well with classical point absorber and volumetric limits of the wave energy conversion device.

42 ENGINEERING↗

Building the Case for Hybrid Energy Developments: Webinar Recording Day 1

INL, PNNL, and NREL, with support from our academic and industry partners, hosted a 2-day webinar to learn more about the benefits of hybrid energy systems, considerations for designing the right system for communities, and practical tools that can help with the design and development process. In Day 1 of this webinar, the focus was on why users might want to consider hybrid energy systems, and frameworks that could help inform design decisions for hybrid systems, including a valuation framework, resilience framework, and hybrid system design optimization framework.

14 SOLAR ENERGY↗

How Can Probabilistic Solar Power Forecasts Be Used to Lower Costs and Improve Reliability in Power Spot Markets? A Review and Application to Flexiramp Requirements

Net load uncertainty in electricity spot markets is rapidly growing. There are five general approaches by which system operators and market participants can use probabilistic forecasts of wind, solar, and load to help manage this uncertainty. These include operator situation awareness, resource risk hedging, reserves procurement, definition of contingencies, and explicit stochastic optimization. We review these approaches, and then provide a case study in which a method for using probabilistic solar forecasts to define needs for reserves is developed and evaluated. The case study has three parts. First, we describe building blocks for enhancing the Watt-Sun solar forecasting system to produce probabilistic irradiance and power forecasts. Second, relationships between Watt-Sun forecasts for multiple sites in California and the system's need for flexible ramp capability (flexiramp) are defined by machine learning and statistical methods. Third, the performance of present methods to defining flexiramp requirements, which are not conditioned on weather and renewables forecasts, is compared with that of probabilistic solar forecast-based requirements, using a multi-timescale production costing model with an 1820-bus representation of the WECC power system. Significant potential savings in fuel and flexiramp procurement costs from using solar-informed reserve requirements are found.

14 SOLAR ENERGY↗

Optimal Managed Fast-Charging Model for Electric Vehicle Fleets with High Utilization and Multiple Charge-Acceptance Curves

A predictive control/scheduling optimization model is proposed for managed charging of an electric vehicle (EV) fleet - under time-of-use energy and demand prices, high vehicle utilization frequency (short dwell times), multiple charge- acceptance curves (configurable charging rates), and flexible vehicle demand. This context is particularly relevant for flight schools (small electric aircraft) or other commercial facilities where an EV fleet performs multiple operating and fast-charging sessions on the same day. The proposed model performs both the operational and charging scheduling of the vehicles, which is not typically done for residential managed charging and significantly increases problem complexity. The problem is formulated as a MILP model and a case study of a small fast-charging station is presented. Results demonstrate a significant reduction in operating cost, mainly from peak shaving during high demand price periods, achieved by coordinating the operation of different vehicles, chargers and charging rates.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Theoretical foundations of waste factor and waste figure with applications to fixed wireless access and relay systems

The growing energy demands of next-generation wireless systems call for unified, system-level metrics to evaluate and optimize energy efficiency. This paper advances the concept of the Waste Factor (W), or Waste Figure (WF) in decibel scale, as a general framework for modeling power loss across cascaded communication components. By integrating W into the Consumption Factor (CF)–the ratio of data rate to consumed power–we reveal how component inefficiencies influence the minimum achievable energy per bit. Closed-form expressions are derived for energy-per-bit consumption in both direct and relay-assisted links, along with a decision rule for selecting the more energy-efficient path. While not explicitly modeled, Reflective Intelligent Surfaces (RIS) are shown to fit naturally within this framework. The analysis is further applied to a Fixed Wireless Access (FWA) scenario, where asymmetries in traffic direction and hardware inefficiencies are jointly considered, demonstrating the utility of the Waste Factor in guiding energy-aware system design.

Sevim, Nurullah [Texas A&M University, College Sta↗

Digital Twin Technology (“Morpheus”) for Optimized Building Operations [SWR-22-74]

The electrification of buildings is an important step to reducing greenhouse gas emissions across all industries. The management of increasingly electrified buildings is a complex pursuit, and there remains a need for cost-effective software capable of handling the computational burden required of such complexity. Through a partnership with Dallas Fort Worth (DFW) Airport, researchers at NREL have developed a digital twin modeling framework to optimize building operations, called Morpheus. Pairing predictive control with automatic fault detection and diagnostics, Morpheus decreases energy expenditures, costs, and faults for large facilities. Additionally, Morpheus employs artificial intelligence to continuously improve its performance using information provided by sensor systems, human experts with deep industry domain knowledge, and even from other similar machines or fleets of machines. Coupling this novel energy-management software with other digital twins, such as NREL’s Athena software for mobility operations, enables robust decision-making for asset and space management. The implementation of Morpheus at DFW has resulted in significantly improved HVAC system operations and reduced both peak power and overall energy consumption. This enhanced functionality comes at a more affordable price than previously developed digital twins and can be customized for other facilities’ geometries to provide optimal, individualized control of a facility’s energy consumption.

Chinde, Venkatesh↗