Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pilot”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

The pilot way to Grid resources using glideinWMS

Grid computing has become very popular in big and widespread scientific communities with high computing demands, like high energy physics. Computing resources are being distributed over many independent sites with only a thin layer of Grid middleware shared between them. This deployment model has proven to be very convenient for computing resource providers, but has introduced several problems for the users of the system, the three major being the complexity of job scheduling, the nonuniformity of computer resources, and the lack of good job monitoring. Pilot jobs address all the above problems by creating a virtual private computing pool on top of Grid resources. This paper presents both the general pilot concept, as well as a concrete implementation, called glideinWMS, deployed in the Open Science Grid.

99 GENERAL AND MISCELLANEOUS↗

Performance Results for Massachusetts and Rhode Island Deep Energy Retrofit Pilot Community

Between December, 2009 and December, 2012, 42 deep energy retrofit (DER) projects were completed through a pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. Thirty-seven of these projects were comprehensive retrofits while five were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. Building Science Corporation developed a consistent "package" of measures in terms of the performance targeted for major building components. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Existing Whole-House Solutions Case Study: National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island

Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. Thirty-seven of these projects were comprehensive retrofits while five were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. Building Science Corporation developed a consistent "package" of measures in terms of the performance targeted for major building components. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects, and was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

airtightness↗

National Grid Deep Energy Retrofit Pilot

Through discussion of five case studies (test homes), this project evaluates strategies to elevate the performance of existing homes to a level commensurate with best-in-class implementation of high-performance new construction homes. The test homes featured in this research activity participated in Deep Energy Retrofit (DER) Pilot Program sponsored by the electric and gas utility National Grid in Massachusetts and Rhode Island. Building enclosure retrofit strategies are evaluated for impact on durability and indoor air quality in addition to energy performance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Overview of Spacecraft Design for Piloting, Manual Control, and Handling Qualities

This report addresses techniques to make spacecraft more compatible with human operation. Starting at the highest context, the first section addresses general spacecraft piloting and workload, presenting a conceptual framework, the OODA loop, as a tool for improvement. As a subset of general operability, manual control is addressed in the second section. The concept of a spectrum of control, from fully manual to fully automatic, is introduced here, as is rationale for implementing manual control capabilities in modern spacecraft. Summaries of manual control capabilities for Apollo and Space Shuttle are also provided as examples of successful implementations. Successful manual control requires satisfactory handling qualities, and a high level summary of that topic is provided in the third section.

Handling↗

Quantification of gypsum crystal nucleation, growth, and breakage rates in a wet flue gas desulfurization pilot plant

The aim of this work is to study the influence of nucleation, growth and breakage on the particle size distribution (PSD) of gypsum crystals produced by the wet flue gas desulfurization (FGD) process. The steady state PSD, obtained in a falling film wet FGD pilot plant during desulfurization of a 1000 ppm(V) SO{sub 2} gas stream, displayed a strong nonlinear behaviour (in a ln(n(l)) vs. I plot) at the lower end of the particle size range, compared to the well-known linear mixed suspension mixed product removal model. A transient population balance breakage model, fitted to experimental data, was able to model an increase in the fraction of small particles, but not to the extent observed experimentally. A three-parameter, size-dependent growth model, previously used for sodium sulphate decahydrate and potash alum, was able to describe the experimental data, indicating either size-dependent integration kinetics or growth rate dispersion.

01 COAL, LIGNITE, AND PEAT↗

Progress in the development and understanding of a high poloidal-beta tokamak operating scenario for an attractive fusion pilot plant

Abstract The high poloidal-beta ( $$\beta _{\textrm{P}}$$ β P ) regime was first proposed as a high bootstrap current scenario for a steady-state fusion pilot plant (FPP) in the 1990s (Kikuchi in Nucl Fusion 30:265, 1990). Since then, there have been many theoretical, modeling, and experimental research activities on this topic. A joint DIII-D/EAST research team began exploring the high- $$\beta _{\textrm{P}}$$ β P regime in 2013, focusing on addressing the needs of attractive FPP design by taking advantage of the extensive diagnostic set and sophisticated plasma control system on DIII-D and the well-developed integrated modeling capability at General Atomics. The ultimate goal is to demonstrate such a scenario on EAST with truly long pulse and metal wall compatibility. This paper summarizes the highlights of the research results on DIII-D by the joint team in the past decade. Experimental evidence and modeling analysis show the high- $$\beta _{\textrm{P}}$$ β P scenario has great advantages in addressing key needs for an attractive FPP design, such as high-energy confinement quality at low rotation, excellent core-edge integration, high line-averaged density above the Greenwald limit, low disruption risk, and high bootstrap current fraction for steady-state operation. This provides a relatively safe and economical option to base an FPP design on that will lead to commercial fusion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long term performance of pilot methanogenic digester filled with seashell wastes treating slaughterhouse wastes: Biogas production and environmental impact

High ammonia and organic acids contents of decomposed slaughterhouse waste (SHW) often result in the severe inhibition or even failure of the anaerobic digestion (AD). The two-stage AD system can alleviate the ammonia inhibition; however, addition of alkali is often needed to maintain the neutral condition. In this study, seashell wastes containing high percentage of calcium carbonate (CaCO 3 ) were for the first time added in a pilot scale methanogenic digester treating chicken blood waste to retain the microorganisms and provide pH buffers for the substrate. A long-duration performance of this digester was conducted for 400 days under different organic loading rates (OLRs). The results show that methane yields of the digester were 244.8 and 224.9 mL g –1 COD added at OLR of 0.4 and 0.6 g COD L –1 d –1 , respectively, higher than the results of previous studies treating the similar feedstock. An AD system treating blood wastes of a typical poultry slaughterhouse was also proposed for which energy balance and carbon footprint analyses were conducted. The energy production of 0.35 MJ kg –1 blood and carbon emissions reduction of 0.05 kg CO 2 -eq kg –1 blood can be achieved from treating blood waste of the broiler chicken. Finally, this study reveals that using seashell wastes in an AD treating SHW can facilitate the reuse of aquaculture wastes and improve the sustainability of meat industry.

09 BIOMASS FUELS↗

Sugar production from bioenergy sorghum by using pilot scale continuous hydrothermal pretreatment combined with disk refining

Chemical-free pretreatments are attracting increased interest because they generate less inhibitor in hydrolysates. In this study, pilot-scaled continuous hydrothermal (PCH) pretreatment followed by disk refining was evaluated and compared to laboratory-scale batch hot water (LHW) pretreatment. Bioenergy sorghum bagasse (BSB) was pretreated at 160–190 °C for 10 min with and without subsequent disk milling. Hydrothermal pretreatment and disk milling synergistically improved glucose and xylose release by 10–20% compared to hydrothermal pretreatment alone. Maximum yields of glucose and xylose of 82.55% and 70.78%, respectively were achieved, when BSB was pretreated at 190 °C and 180 °C followed by disk milling. LHW pretreated BSB had 5–15% higher sugar yields compared to PCH for all pretreatment conditions. The surface area improvement was also performed. PCH pretreatment combined with disk milling increased BSB surface area by 31.80–106.93%, which was greater than observed using LHW pretreatment.

09 BIOMASS FUELS↗

Wallula Basalt Pilot Demonstration Project: Post-injection Results and Conclusions

Deep underground geologic formations are emerging as a reasonable option for long-term storage of CO 2 , including large continental flood basalt formations. At the GHGT-11 and GHGT-12 conferences, progress was reported on the initial phases for Wallula Basalt Pilot demonstration test (located in Eastern Washington state), where nearly 1,000 metric tons of CO 2 were injected over a 3-week period during July/August 2013. The target CO 2 injection intervals were two permeable basalt interflow reservoir zones with a combined thickness of ~20 m that occur within a layered basalt sequence between a depth of 830-890 m below ground surface. During the two-year post-injection period, downhole fluid samples were periodically collected during this post-injection monitoring phase, coupled with limited wireline borehole logging surveys that provided indirect evidence of on-going chemical geochemical reactions/alterations and CO 2 disposition. A final detailed post-closure field characterization program that included downhole fluid sampling, and performance of hydrologic tests and wireline geophysical surveys. Included as part of the final wireline characterization activities was the retrieval of side-wall cores from within the targeted injection zones. These cores were examined for evidence of in-situ mineral carbonization. Visual observations of the core material identified small globular nodules, translucent to yellow in color, residing within vugs and small cavities of the recovered basalt side-wall cores, which were not evident in pre-injection side-wall cores obtained from the native basalt formation. Characterization by x-ray diffraction identified these nodular precipitates as ankerite, a commonly occurring iron and calcium rich carbonate. Isotopic characterization (δ 13 C, δ 18 O) conducted on the ankerite nodules indicate a distinct isotopic signature that is closely aligned with that of the injected CO 2 . Both the secondary mineral nodules and injected CO 2 are measurably different from the isotopic content of basalt, injection zone groundwater and for naturally occurring calcite. Final post-injection wireline geophysical logging results also indicate the presence of free-phase CO 2 at the top of the two injection interflow zones, with no vertical migration of CO 2 above the injection horizons. Furthermore, these findings are significant and demonstrate the feasibility of sequestering CO 2 in a basalt formation.

54 ENVIRONMENTAL SCIENCES↗

Pilot testing of a heat integrated 0.7 MWe CO 2 capture system with two-stage air-stripping: Amine degradation and metal accumulation

An advanced 0.7 MWe small pilot coal-fired post-combustion CO 2 capture system with heat integration combined with two-stage stripping was tested here on a slipstream of flue gas by the University of Kentucky Center for Applied Energy Research (UKy-CAER). Evaluation of solvent degradation products was performed to determine the impact of oxygen exposure due to incorporation of the secondary air stripper into the conventional amine absorber/stripper system. The overall degradation rates and products observed during the testing campaign were comparable to previously published reports using 30% monoethanolamine (MEA) as the baseline/commissioning solvent. The rates of heat stable salt accumulation and amine degradation were similar to those from conventional CO 2 capture systems using MEA. Metal accumulation as the result of material corrosion inside the system from an improperly constructed material was observed. Finally, the impact of the secondary air stripper appears negligible relative to other published MEA campaigns tested at similar flue gas conditions and system operating hours.

03 NATURAL GAS↗

Effects of carbon treating on piperazine oxidation in pilot plant testing of PZAS™

From February to June 2019, a pilot plant campaign was run for 2100 h at the National Carbon Capture Center (NCCC) using moderately degraded 5 m PZ with simulated flue gas equivalent to a 0.64 MW natural gas combined cycle. Piperazine with the Advanced Stripper™ (PZAS™) and a baghouse were used, and N 2 sparging was applied at the bottom of the absorber. A carbon bed was activated and showed beneficial effects in removing degradation products and reducing the oxidation rate. The cumulative NH 3 production was 180 mmol/k, indicating a PZ oxidation rate of 0.07 mmol/kg/h (0.3 kg PZ/tonne of CO 2 ). The total formate before turning on the carbon bed was 41 mmol/kg, and the total Fe was 0.1 mmol/kg. Carbon treating reduced NH3 production from 0.1 mmol/kg/h to 0.056 mmol/kg/h after 400 h of operation, reduced the UV-Vis absorbance of the samples at 320 nm, and caused a decrease of dissolved Cr. Bench-scale experiments were performed using the NCCC solvent and the same type of carbon. In bench-scale experiments, the UV-Vis absorbance and the concentration of Fe, Mn, and Cr all decreased. Finally, a linear equilibrium relationship was observed between the UV-Vis absorbance and the carbon loading.

03 NATURAL GAS↗

Energy use of piperazine with the advanced stripper from pilot plant testing

Here, piperazine with the Advanced Stripper (PZAS™) was tested at the National Carbon Capture Center (NCCC) at coal and NGCC conditions. Energy performance was measured with accounting for heat loss. The net heat duty was found to be identical at 2.45 GJ/tonne for both 4 and 12% CO 2 at 90% CO 2 removal. The average measured heat loss was 0.38 GJ/tonne and represented 30% of the gross heat rate. For PZAS, the warm rich piping before the control valve is the largest in surface area. Heat loss at this location increased heat duty by 80% of the heat loss value. Therefore, the total heat duty was decreased by 80% of the heat loss. The Independence™ model was validated using 112 steady-state pilot plant runs and predicted average net heat duty with an error of 9% and lean loading with an error of 10%. The model was used to simulate process impacts of heat loss for the PZAS and simple stripper configurations. For both strippers, heat loss was found to impact heat duty at locations other than just the steam heater. While heat loss in the steam heater was the most important for PZAS, heat loss in the column was the most important for the simple stripper due to a large top-side pinch and CO 2 reabsorption at the same location. CO 2 reabsorption in PZAS occurred only at high heat loss values (~0.14 GJ/hr), compared to low heat loss values (~ 0.03 GJ/hr) in the PZ-simple stripper. Excessive packing in the PZ-simple stripper caused a large top-side pinch at 0.23 mol/mol lean loading, making the column very sensitive to heat loss. Heat loss in the PZ-simple stripper increased heat duty by 120–150% at typical heat loss values and lean loading of 0.23 mol/mol. Heat loss in the MEA-simple stripper only increased heat duty by 1–13% in a typical lean loading range of 0.1–0.2 mol/mol. A large bottom side pinch at low lean loading for 7 m MEA made the effect of heat loss less pronounced.

42 ENGINEERING↗

Decontamination of industrial cyanide-containing water in a solar CPC pilot plant

The aim of this work was to improve the quality of wastewater effluent coming from an Integrated Gasification Combined-Cycle (IGCC) power station to meet with future environmental legislation. This study examined a homogeneous photocatalytic oxidation process using concentrated solar UV energy (UV/Fe(II)/H{sub 2}O{sub 2}) in a Solar Compound Parabolic Collector (CPC) pilot plant. The efficiency of the process was evaluated by analysis of the oxidation of cyanides and Total Organic Carbon (TOC). A factorial experimental design allowed the determination of the influences of operating variables (initial concentration of H{sub 2}O{sub 2}, oxalic acid and Fe(II) and pH) on the degradation kinetics. Temperature and UV-A solar power were also included in the Neural Network fittings. The pH was maintained at a value >9.5 during cyanide oxidation to avoid the formation of gaseous HCN and later lowered to enhance mineralization. Under the optimum conditions ([H{sub 2}O{sub 2}] = 2000 ppm, [Fe(II)] = 8 ppm, pH = 3.3 after cyanide oxidation, and [(COOH){sub 2}] = 60 ppm), it was possible to degrade 100% of the cyanides and up to 92% of Total Organic Carbon. (author)

14 SOLAR ENERGY↗

Pilot microbial electrolysis cell closes the hydrogen loop for hydrothermal wet waste conversion to jet fuel

The global shift toward net-zero emissions necessitates resource recovery from wet waste. In this study, we demonstrate the first feasibility of combining pilot-scale microbial electrolytic cells (MECs) with hydrothermal liquefaction (HTL) for simultaneous post-hydrothermal liquefaction wastewater (PHW) treatment and efficient hydrogen (H₂) production to meet biocrude upgrading requirements. Long-term single reactor operation revealed that fixed anode potential enabled rapid startup, and low catholyte pH and high salinity were effective in suppression of cathodic methanogenesis and acetogenesis – resulting in high current density of 16.6 A m –2 and 9.3 A m –2 when feeding synthetic wastewater and PHW respectively. Additionally, the anode biofilm exhibited spatial variations in response to local environmental conditions. In conclusion, onsite parallel or serial operations of multiple MECs showed good performance using actual PHW with a record-high H 2 production rate of 0.5 L L R day –1 for MEC over 10 liters scale, and the optimal chemical oxygen demand (COD)-to-H 2 yield reached 0.127 kg-H 2 per kg-COD, supporting a self-sufficient, closed-loop upgrade to jet fuel.

08 HYDROGEN↗

Use of Carbon Steel for Construction of Post-combustion CO 2 Capture Facilities: A Pilot-Scale Corrosion Study

Corrosion studies were carried out on metal coated and noncoated carbon steel as well as stainless steel in a pilot-scale post-combustion CO 2 capture process. Aqueous 30 wt % monoethanolamine (MEA) solvent was used without any chemical additive for antioxidation to examine a worst-case scenario where corrosion is not mitigated. The corrosion rate of all carbon steels was almost zero in the absorber column and CO 2 lean amine piping except for Ni-coated carbon steel (<1.8 mm/yr). Ni 2 Al 3 /Al 2 O 3 precoated carbon steels showed initial protection but lost their integrity in the stripping column and CO 2 rich amine piping, and severe corrosion was eventually observed for all carbon steels at these two locations. Stainless steel was found to be stable and corrosion resistant in all of the sampling locations throughout the experiment. This study provides an initial framework for the use of carbon steel as a potential construction material for process units with relatively mild operating conditions (temperature less than 80 °C), such as the absorber and CO 2 lean amine piping of a post-combustion CO 2 capture process. As a result, it also warrants further investigation of using carbon steel with more effective corrosion mitigation strategies for process units where harsh environments are expected (such as temperatures greater than 100 °C).

36 MATERIALS SCIENCE↗

High-Efficiency Conversion of Ionic Liquid-Pretreated Woody Biomass to Ethanol at the Pilot Scale

We report that with a diverse and widely distributed global resource base, woody biomass is a compelling organic feedstock for conversion to renewable liquid fuels. In California, woody biomass comprises the largest fraction of underutilized biomass available for biofuel production, but conversion to fuels is challenged both by recalcitrance to deconstruction and by toxicity toward downstream saccharification and fermentation due to organic acids and phenolic compounds generated during pretreatment. In this study, we optimize pretreatment and scale-up of an integrated one-pot process for deconstruction of California woody biomass using the ionic liquid (IL) cholinium lysinate [Ch][Lys] as a pretreatment solvent. By evaluating the impact of solid loading, solid removal, yeast acclimatization, fermentation temperature, fermentation pH, and nutrient supplementation on final ethanol yields and titers, we achieve nearly full conversion of both glucose and xylose to ethanol with commercial C5-utilizing Saccharomyces cerevisiae. We then demonstrate process scalability in 680 L pilot-scale fermentation, achieving >80% deconstruction efficiency, >90% fermentation efficiency, 27.7 g/L ethanol titer, and >80% ethanol distillation efficiency from the IL-containing hydrolysate post fermentation. This fully integrated process requires no intermediate separations and no intermediate detoxification of the hydrolysate. Using an integrated biorefinery model, current performance results in a minimum ethanol selling price of $\$$8.8/gge. Reducing enzyme loading along with other minor process improvements can reduce the ethanol selling price to $\$$3/gge. This study is the largest scale demonstration of IL pretreatment and biofuel conversion known to date, and the overall biomass-to-ethanol efficiencies are the highest reported to date for any IL-based biomass-to-biofuel conversion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗