Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance portable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Using SpF to Achieve Petascale for Legacy Pseudospectral Applications

Pseudospectral (PS) methods possess a number of characteristics (e.g., efficiency, accuracy, natural boundary conditions) that are extremely desirable for dynamo models. Unfortunately, dynamo models based upon PS methods face a number of daunting challenges, which include exposing additional parallelism, leveraging hardware accelerators, exploiting hybrid parallelism, and improving the scalability of global memory transposes. Although these issues are a concern for most models, solutions for PS methods tend to require far more pervasive changes to underlying data and control structures. Further, improvements in performance in one model are difficult to transfer to other models, resulting in significant duplication of effort across the research community. We have developed an extensible software framework for pseudospectral methods called SpF that is intended to enable extreme scalability and optimal performance. Highlevel abstractions provided by SpF unburden applications of the responsibility of managing domain decomposition and load balance while reducing the changes in code required to adapt to new computing architectures. The key design concept in SpF is that each phase of the numerical calculation is partitioned into disjoint numerical kernels that can be performed entirely inprocessor. The granularity of domain decomposition provided by SpF is only constrained by the datalocality requirements of these kernels. SpF builds on top of optimized vendor libraries for common numerical operations such as transforms, matrix solvers, etc., but can also be configured to use open source alternatives for portability. SpF includes several alternative schemes for global data redistribution and is expected to serve as an ideal testbed for further research into optimal approaches for different network architectures. In this presentation, we will describe our experience in porting legacy pseudospectral models, MoSST and DYNAMO, to use SpF as well as present preliminary performance results provided by the improved scalability.

DYNAMO↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-FG-209-04: Testing of Digital Image Receptors Using AAPM TG-150’s Draft Recommendations - Investigating the Impact of Different Processing Parameters

Purpose: To evaluate implementation of AAPM TG-150’s draft recommendations via a parameter study for testing the performance of digital image receptors. Methods: Flat field images were acquired from 9 calibrated digital image receptors associated with 9 new portable digital radiography systems (Carestream Health, Inc.) based on the draft recommendations and manufacturer-specified calibration conditions (set of 4 images at input detector air kerma ranging from 1 to 25 µGy). Effects of exposure response function (linearized and logarithmic), ‘Presentation Intent Type’ (‘For Processing’ and ‘For Presentation’), detector orientation with respect to the anode-cathode axis (4 orientations; 900 rotations per iteration), different ROI sizes (5×5–40×40 mm{sup 2}) and elimination of varying dimensions of image border (0 mm i.e., without boundary elimination to 150 mm) on signal, noise, signal-to-noise ratio (SNR) and the associated nonuniformities were evaluated. Images were analyzed in Matlab and quantities were compared using ANOVA. Results: Signal, noise and SNR values averaged over 9 systems with default parameter values in draft recommendations were 4837.2±139.4, 19.7±0.9 and 246.4±10.1 (mean ± standard deviation), respectively (at input detector air kerma: 12.5 µGy). Signal, noise and SNR showed characteristic dependency on exposure response function and on ‘Presentation Intent Type’. These values were not affected by ROI size and detector orientation, but analysis showed that eliminating the edge pixels along the boundary was required for the noise parameter (coefficient of variation range for noise: 72%–106% and 3%–4% without and with boundary elimination; respectively). Local and global nonuniformities showed a similar dependence on the need for boundary elimination. Interestingly, computed non-uniformities showed agreement with manufacturer-reported values except for noise non-uniformities in two units; artifacts were seen in images from these two units highlighting the importance of independent evaluations. Conclusion: The effect of different parameters on performance characterization of digital image receptors was evaluated based on TG-150’s draft recommendations.

60 APPLIED LIFE SCIENCES↗

Development of a Portable Training Tool for Simulating Visceral Angiographic Procedures for Beginners

The purpose of this study was to evaluate the usefulness of a tool that we developed to simulate performance of visceral angiography to train beginners in the field of splanchnic angiography. Seven residents and two fellows who were rotating within the Division of Interventional Radiology at our institution between June and August 2008 participated in the evaluation of this tool. They had no experience in performing visceral angiography as an operator. Time for selection of arterial branches arising from the celiac axis on the model was measured before and after training. After such training, the participants performed actual visceral angiography as an operator with instructors beside them. Success of the trainees in selecting visceral arterial branches was evaluated in these real-life cases. In the first test using the model, seven of nine trainees (77.8%) succeeded in selecting all required arteries, while the remaining two failed to select all required arteries. After training using the model, all trainees succeeded in selecting all required arteries just before the actual angiographic study. In the actual angiography, the catheter was successfully inserted from the femoral artery and advanced to the superior mesenteric, celiac, splenic, common hepatic, gastroduodenal, and right and left hepatic arteries by all trainees with only two exceptions. In conclusion, this tool is helpful for training beginners in visceral angiographic procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A high-speed linear algebra library with automatic parallelism

Parallel or distributed processing is key to getting highest performance workstations. However, designing and implementing efficient parallel algorithms is difficult and error-prone. It is even more difficult to write code that is both portable to and efficient on many different computers. Finally, it is harder still to satisfy the above requirements and include the reliability and ease of use required of commercial software intended for use in a production environment. As a result, the application of parallel processing technology to commercial software has been extremely small even though there are numerous computationally demanding programs that would significantly benefit from application of parallel processing. This paper describes DSSLIB, which is a library of subroutines that perform many of the time-consuming computations in engineering and scientific software. DSSLIB combines the high efficiency and speed of parallel computation with a serial programming model that eliminates many undesirable side-effects of typical parallel code. The result is a simple way to incorporate the power of parallel processing into commercial software without compromising maintainability, reliability, or ease of use. This gives significant advantages over less powerful non-parallel entries in the market.

Boucher, Michael L.↗

Performance Testing and Validation Plan for HMS4 Quantitative Gamma Measurements, K-25/K-27 D&D Project, East Tennessee Technology Park, Oak Ridge, Tennessee

The Holdup Measurement System 4 (HMS4) is a portable thallium activated sodium iodide (NaI[Tl]) gamma ray energy spectrometer that, when properly calibrated, is able to make quantifiable assessment of U-235 holdup in the presence of other uranium isotopes and prevailing background radiation. The use and calibration of the HMS4 is based upon the methodologies defined by Russo in La-14206, (Russo 2005), where detection efficiency determination protocols are defined (called Generalized Geometry Holdup [GGH]). The GGH methodology together with attenuation correction algorithms and other modeling parameters are combined in the HMS4 software package to provide a comprehensive tool for conducting in situ gamma-ray measurements. The fundamental principles of these capabilities are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-Cost, Class D Testing of Spacecraft Photovoltaic Systems Can Reduce Risk

The end-to-end verification of a spacecraft photovoltaic power generation system requires light! A lowcost, portable, and end-to-end photovoltaic-system test appropriate for NASA's new generation of Class D missions is presented. High risk, low-cost, and quick-turn satellites rarely have the resources to execute the traditional approaches from higher-class (A-C) missions. The Class D approach, as demonstrated on the Lunar Atmospheric and Dust Environment Explorer (LADEE), utilizes a portable, metalhalide, theatre lamp for an end-to-end photovoltaic system test. While not as precise and comprehensive as the traditional Large Area Pulsed Solar Simulator (LAPSS) test, the LADEE method leverages minimal resources into an ongoing assessment program that can be applied through numerous stages of the mission. The project takes a true Class D approach in assessing the technical value of a costly, highfidelity performance test versus a simpler approach with less programmatic risk. The resources required are a fraction of that for a LAPSS test, and is easy to repeat due to its portability. Further, the test equipment can be handed down to future projects without building an on-site facility. At the vanguard of Class D missions, the LADEE team frequently wrestled with and challenged the status quo. The philosophy of risk avoidance at all cost, typical to Class A-C missions, simply could not be executed. This innovative and simple testing solution is contextualized to NASA Class D programs and a specific risk encountered during development of the LADEE Electrical Power System (EPS). Selection of the appropriate lamp and safety concerns are discussed, with examples of test results. Combined with the vendor's panellevel data and periodic inspection, the method ensures system integrity from Integration and Test (I&T) through launch. Following launch, mission operations tools are utilized to assess system performance based on a scant amount of available data.

power systems↗

Mechanical stress measurement by an achromatic optical digital speckle pattern interferometry strain sensor with radial in-plane sensitivity: experimental comparison with electrical strain gauges

This paper shows the optical setup of a radial in-plane digital speckle pattern interferometer which uses an axis-symmetrical diffractive optical element (DOE) to obtain double illumination. The application of the DOE gives in-plane sensitivity which only depends on the grating period of the DOE instead of the wavelength of the laser used as illumination source. A compact optical layout was built in order to have a portable optical strain sensor with a circular measurement area of about 5 mm in diameter. In order to compare its performance with electrical strain sensors (strain gauges), mechanical loading was generated by a four-point bending device and simultaneously monitored by the optical strain sensor and by two-element strain gauge rosettes. Several mechanical stress levels were measured showing a good agreement between both sensors. Results showed that the optical sensor could measure applied mechanical strains with a mean uncertainty of about 5% and 4% for the maximum and minimum principal strains, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NMIS with Imaging and Gamma Ray Spectrometry for Pu, HEU, HE and Other Materials

The Nuclear Material Identification System (NMIS) has been under development at ORNL and the National Nuclear Security Administration (NNSA) Y-12 National Security Complex since 1984. In the mid-1990s, what is now the US Department of Energy (DOE) Office of Nuclear Verification (ONV) realized that it was a useful technology for future arms control treaty applications and supported further development of the system. In 2004, fast-neutron imaging was incorporated into the system. In 2007, the ONV decided to develop a fieldable version of the system, designated as FNMIS, for potential use in future treaties. The FNMIS is being developed to be compatible with the eventual incorporation of gamma-ray spectrometry and an information barrier. This report addresses how and what attributes could be determined by the FNMIS system with gamma-ray spectrometry. The NMIS is a time-dependent coincidence system that incorporates tomographic imaging (including mapping of the fission sites) and gamma-ray spectrometry. It utilizes a small, lightweight (30 lb), portable deuterium-tritium (DT) neutron (14.1 MeV) generator (4 x 10 7 neutrons/second) for active interrogation and can also perform passive interrogation. A high-purity germanium (HPGe) gamma-ray detector with multichannel analysis can be utilized in conjunction with the source for active interrogation or passively. The system uses proton recoil scintillators: 32 small 2.5 x 2.5 x 10.2-cm-thick plastic scintillators for imaging and at least two 2 x 2 arrays of 27 x 27 x 10-cm-thick plastic scintillators that detect induced fission radiation. The DT generator contains an alpha detector that time and directionally tags a fan beam of some of the neutrons emitted and subdivides it into pixels. A fast (1 GHz) time correlation processor measures the time-dependent coincidence among all detectors in the system. A computer-controlled scanner moves the small detectors and the source appropriately for scanning a target object for imaging. The system is based on detection of transmitted 14.1 MeV neutrons, fission neutrons, and gamma rays from spontaneous, inherent source fission of the target, fission neutrons and gamma rays induced by the external DT source, gamma rays from natural emissions of uranium and plutonium, and induced gamma-ray emission by the interaction of the 14.1 MeV neutrons from the DT source. The NMIS can and has been used with a time-tagged californium spontaneous fission source. It has also been used with pulsed interrogation sources such as LINACs, DT, and deuterium-deuterium (DD) sources. This system is uniquely suited for detection of shielded highly enriched uranium (HEU), plutonium, and other special nuclear materials and detection of high explosives (HE) and chemical agents. The NMIS will be adapted to utilize a trusted processor that incorporates information barrier and authentication techniques using open software and then be useful in some international applications for materials whose characteristics may be classified. The proposed information barrier version of the NMIS system would consist of detectors and cables, the red (classified side) computer system, which processes the data, and the black (unclassified side) computer, which handles the computer interface. The system could use the 'IB wrapper' concept proposed by Los Alamos National Laboratory and the software integrity (digital signatures) system proposed by Sandia. Since it is based entirely on commercially available components, the entire system, including NMIS data acquisition boards, can be built with commercial off-the-shelf components. This system is being developed into a fieldable system (FNMIS) for potential arms control treaties by the ONV. The system will be modularly constructed with the RF shielded modules connected to the processor by appropriate control and signal cable in metal conduit. The FNMIS is presently being designed for eventual incorporation of gamma-ray spectrometry and an information barrier to protect classified information. The system hardware and software can be configured to obtain the following: plutonium presence, plutonium mass, Pu-240/239 ratio, plutonium geometry, plutonium metal vs non-metallic (absence of metal), time (age) since processing for plutonium (or last purification), uranium presence, uranium mass, uranium enrichment, uranium geometry, uranium metal vs non-metallic compound (absence of metal), beryllium presence and mass, tritium and deuterium gas bottle presence, HE, and chemical weapons. A matrix of the quantities determined, the method of determination, whether active (external neutron source) or passive, and the measurement equipment involved is given in the Tables 1-4. Some of these attributes can be obtained by multiple data analysis methods. The gamma-ray spectrometry methods for HEU, plutonium, and HE have been developed by other laboratories, are well known, and will be incorporated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EPC-ES WIPP WAC Appendix A Equivalence Support Measurements 2019-2020

Characterization of low-level waste (LLW) at Los Alamos National Laboratory (LANL) is primarily performed by the Environmental Protection and Compliance - Environmental Stewardship (EPC-ES) Characterization Services team and/or the Nuclear Process Infrastructure (NPI--9) Nuclear Material Support Services team (hereafter referred to as the gamma spectroscopy teams). The gamma spectroscopy teams use portable high-purity germanium (HPGe) detector systems for the nondestructive assay (NDA) characterization of LLW. Controlled-approved procedures and processes for the use of such systems to assay LLW items are currently in place. Additionally, a number of performance studies have been conducted by the gamma spectroscopy teams to support the efficacy and quality of assay results generated by the established NDA process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING↗

Tube dimpling tool assures accurate dip-brazed joints

Portable, hand-held dimpling tool assures accurate brazed joints between tubes of different diameters. Prior to brazing, the tool performs precise dimpling and nipple forming and also provides control and accurate measuring of the height of nipples and depth of dimples so formed.

Beuyukian, C. S.↗

Display management subsystem, version 1: A user's eye view

The structure and application functions of the Display Management Subsystem (DMS) are described. The DMS, a subsystem of the Transportable Applications Executive (TAE), was designed to provide a device-independent interface for an image processing and display environment. The system is callable by C and FORTRAN applications, portable to accommodate different image analysis terminals, and easily expandable to meet local needs. Generic applications are also available for performing many image processing tasks.

Parker, Dolores↗

Development Requirements for the Exploration PLSS (xPLSS) Carbon Dioxide and Humidity Control Unit (CDHCU)

Functional Requirements for the Carbon Dioxide and Humidity Control Unit (CDHCU): The CDHCU is a component of the Exploration Portable Life Support System (xPLSS) to provide carbon dioxide (CO2) and humidity control within the spacesuit for a crewmember to perform extravehicular activities (EVA) in vacuum (micro-g), lunar, and Mars environments for up to 8 hours continuous, and during EVA preparation in airlocks or support vehicles for an additional 2 hours (TBR) continuous.

Chullen, Cinda↗

SERFE Water Quality Results

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. Water quality, and how that impacts the performance of the life support system hardware, are areas where improvements could greatly help to achieve these goals. The Suit Water Membrane Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal loop technologies was developed and has been under test in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack since November of 2020. In addition to the SWME, The SWME EXPRESS Rack Flight Experiment (SERFE) contains several technology demonstrations from the xEMU project and has been demonstrating their performance in micro-gravity and over an extended duration. This paper will summarize the results of the water quality analysis performed to date throughout the SERFE testing program. Special care was taken to select materials, process hardware, and control the quality of the feedwater used in SERFE testing so that it would be representative of a thermal control system that could be used on a spacesuit for a lunar mission. In addition, the testing schedule, including periods of quiescence in between tests, was also selected to simulate a real mission profile in ways that would be critical to water quality. Results include data and analysis on microbial activity, biocidal iodine, metals, organic carbon, and several other customary indicators of water quality in an operational system. Testing spans over a year and a half of wetted life of the SERFE Flight Unit and the SERFE Ground Unit.

Colin Campbell↗

Plutonium Detection with Straw Neutron Detectors

A kilogram of weapons grade plutonium gives off about 56,000 neutrons per second of which 55,000 neutrons come from spontaneous fission of 240Pu (~6% by weight of the total plutonium). Actually, all even numbered isotopes (238Pu, 240Pu, and 242Pu) produce copious spontaneous fission neutrons. These neutrons induce fission in the surrounding fissile 239Pu with an approximate multiplication of a factor of ~1.9. This multiplication depends on the shape of the fissile materials and the surrounding material. These neutrons (typically of energy 2 MeV and air scattering mean free path >100 meters) can be detected 100 meters away from the source by vehicle-portable neutron detectors. [1] In our current studies on neutron detection techniques, without using 3He gas proportional counters, we designed and developed a portable high-efficiency neutron multiplicity counter using 10B-coated thin tubes called straws. The detector was designed to perform like commercially available fission meters (manufactured by Ortec Corp.) except instead of using 3He gas as a neutron conversion material, we used a thin coating of 10B.

plutonium, neutron, straw↗

SPEChpc 2021 Benchmark Suites for Modern HPC Systems

The SPEChpc 2021 suites are application-based benchmarks de- signed to measure performance of modern HPC systems. The bench- marks support MPI, MPI+OpenMP, MPI+OpenMP target offload, MPI+OpenACC and are portable across all major HPC platforms.

Boehm, Swen↗

Application of the PHDS Germanium Gamma-ray Imager (GeGI) in Facility Decontamination Assessment - 19471

As part of a site wide investigation, U.S. EPA Region 5 had to assess the nature and extent of contamination in a former radioactive source manufacturing facility. This work involved verification of the radioisotope expected, ensuring no other radioisotopes were present, and quantification of the activity and areal extent of contamination throughout the facility. The device used to support this assessment work was the Germanium Gamma-ray Imager (GeGI) manufactured by PHDS Co. of Knoxville, Tennessee. GeGI is a germanium-semiconductor imaging detector system that provides identification, location, and quantification of radioactive materials within its field of view. GeGI provides the highest fidelity radiological assay information including the best gamma-ray energy resolution and spatial localization of any existing technology, including gamma-ray energy resolution of ∼0.3% full-width half-max (FWHM) at 662 keV and angular location resolution ∼ +/-1 degree. The GeGI is a mechanically cooled, portable system well-suited to field operations. PHDS Co. also provided on-site support during assessment operations and performed subsequent data analysis. Gamma-ray spectral data and associated images were collected with GeGI in six primary areas of the facility having significant residual contamination. A total of 61 gamma-ray spectrum/image sets were collected over the course of three working days (22 Compton images and 39 Pinhole/Compton images). During data collection, Compton imaging was used as the means by which to identify and prioritize hotspots. After contaminated regions were identified via Compton imaging, short-distance Pinhole spectrum/image sets were collected for additional analysis. All of the spectrum/image sets were analyzed to determine the radioisotope distribution within the GeGI field of view, as well as to provide an estimate of the activity associated with each hotspot. It was determined that the nature of residual contamination present was distributed across specific areas of elevated activity, where in some areas there was significant accumulation of contaminated material. It was also determined that no discrete sources of high-activity were present, as would be expected in the case of radioactive material product intended for sealed source manufacture. Results included the activity of residual contamination for each of the areas assessed, and an estimate of the physical area over which that contamination was distributed. It was anticipated by EPA that if decontamination were to be performed that it would involve some type of concrete scabbling or other means of physical removal of contaminated material. The GeGI data could be used to estimate the areal extent (square footage) of concrete removal that would be required for decontamination. Using the activity estimate data from the GeGI along with an estimated depth of concrete removal, planning could be performed for decontamination work (equipment and personnel), waste collection, packaging, transportation, and disposal, along with an associated cost estimate. With regard to health and safety, use of the GeGI reduced the radiation dose to the EPA R5 staff performing the assessment work. The GeGI is a non-destructive device that supports assessment of radioactively contaminated areas and sources from a distance, reducing the need for close contact to radiation, and the time necessary for personnel to operate near such hazards. Use of the GeGI in this facility assessment was our first attempt to apply this technology in what proved to be a quick and efficient decontamination assessment method. The GeGI can assess the nature and extent of residual contamination in a facility, first by quickly identifying the areas of elevated activity, followed by refined measurement and assessment of those elevated areas. The GeGI data can then be used to develop planning and a cost estimate of required decontamination and waste management activities. Since it's a non-destructive gamma identification and imaging device, it can reduce the distance of workers from radioactive sources and the dose incurred from assessment work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗