Structural-Thermal-Optical Program (STOP)

A structural thermal optical computer program is developed which uses a finite element approach and applies the Ritz method for solving heat transfer problems. Temperatures are represented at the vertices of each element and the displacements which yield deformations at any point of the heated surface are interpolated through grid points.

Lee, H. P.↗

Feasibility study in the application of optical signal analysis to non-destructive testing of complex structures

Advantages of the large time bandwidth product of optical processing are presented. Experiments were performed to study the feasibility of the use of optical spectral analysis for detection of flaws in structural elements excited by random noise. Photographic and electronic methods of comparison of complex spectra were developed. Limitations were explored, and suggestions for further work are offered.

Baker, B.↗

Pulse profile and refined orbital elements for SMC X-1

Results of a reanalysis of SAS-3 data for SMC X-1, including greatly improved orbital elements, are presented. These elements, when combined with newly available data for the optical companion, Sk 160, yield improved estimates for the masses of SMC X-1 and Sk 160. A significant rate of change of intrinsic pulse period is detected during the course of the four-day observation which is consistent with the average value that was previously deduced from observations separated by 5 years. The X-ray pulse profile, averaged over one orbital cycle and with approximately 15-ms time resolution, is also presented. The pulse profile is found to be constant to within statistics, as a function of orbital phase. The implications of the small observed eccentricities of SMC X-1 and other binary X-ray pulsar systems are discussed.

Primini, F.↗

The distribution of S IV and Ne II in NGC 7027

Results are reported for measurements of the S IV 10.5-micron and Ne II 12.8-micron IR emission lines at four positions in NGC 7027 and of the Ar III 9.0-micron line at one position in the same planetary nebula. Ionic abundances are calculated using the data obtained at one position and are combined with published optical data for other ionization states to obtain total elemental abundances. The S IV and Ne II line-intensity distributions are compared with an 8.1-GHz radio map of the nebula. The S IV distribution indicates a density of about 500,000 per cu cm, and the Ne II is found to be contained in low-ionization regions distributed inhomogeneously throughout the nebula. The total abundances relative to hydrogen are determined to be 0.000015 for S, 0.000053 for Ne, and 0.000007 for Ar; these abundances are shown to be within the range of published average values for planetary nebulae.

Bregman, J. D.↗

Survey of probable micrometer-sized Earth-orbital debris fragments in the NASA-JSC cosmic dust sample collection

A program to collect extraterrestrial dust samples from the stratosphere using impactors mounted on NASA U-2 and WB-57F aircraft is discussed. Sample collection, preparation, and analysis techniques are described and the particle types found are reviewed. Preliminary examination of the particles indicates that they represent not only extraterrestrial material, but some fraction of terrestrial contamination from both natural and manmade sources. This examination involves a combination of optical microscopy, scanning electron microscopy (SEM) and qualitative bulk elemental analysis using an energy-dispersive X-ray spectrometer (EDS) to characterize each particle. The cosmic dust collection contains samples of at least three classes of material that may present some hazard to extended spacecraft operations in near-Earth orbit: (1) micrometeorites/cosmic dust, (2) aluminum oxide spheres, and (3) alloy spherules and fragments.

Clanton, U. S.↗

In situ composite cure monitoring using infrared transmitting optical fibers

The development of infrared-transmitting optical fibers as sensors for monitoring the cure of advanced composite materials is reported. Fourier transform infrared spectra are presented which were remotely sensed during the cure of a high performance polyimide resin and a graphite/polyimide matrix prepreg using an 0.1 mm O.D. x 3 m chalcogenide optical fiber. A discussion of the fiber and sensor element, absorption mechanism and potential applications is presented.

Young, Philip R.↗

Investigation of buried homojunctions in p-InP formed during sputter deposition of both indium tin oxide and indium oxide

While dc magnetron sputter deposition of indium tin oxide leads to the formation of a buried homojunction in single crystal p-type InP, the mechanism of type conversion of the InP surface is not apparent. In view of the recent achievement of nearly 17-percent global efficiencies for cells fabricated solely by sputter deposition of In2O3, it is presently surmised that tin may not be an essential element in type conversion. A variety of electrical and optical techniques are presently used to evaluate the changes at both indium tin oxide/InP and indium oxide/InP interfaces. Such mechanisms as the passivation of acceptors by hydrogen, and sputter damage, are found to occur simultaneously.

Gessert, T. A.↗

Demonstration AOTF Imaging Spectrometer

Spectral images of high quality obtained. Acousto-optical-tunable-filter (AOTF) imaging spectrometer is optical system in which AOTF serves as spectrally dispersive element causing image on final focal plane to be shifted on plane by distance depending on wavelength of light emanating from scene. Useful in several applications involving identification, via characteristic spectras, of substances in observed scenes: examples include prospecting for minerals and detecting chemical pollutants.

Chao, Tien-Hsin↗

Rover imaging system for the Mars rover/sample return mission

In the past year, the conceptual design of a panoramic imager for the Mars Environmental Survey (MESUR) Pathfinder was finished. A prototype camera was built and its performace in the laboratory was tested. The performance of this camera was excellent. Based on this work, we have recently proposed a small, lightweight, rugged, and highly capable Mars Surface Imager (MSI) instrument for the MESUR Pathfinder mission. A key aspect of our approach to optimization of the MSI design is that we treat image gathering, coding, and restoration as a whole, rather than as separate and independent tasks. Our approach leads to higher image quality, especially in the representation of fine detail with good contrast and clarity, without increasing either the complexity of the camera or the amount of data transmission. We have made significant progress over the past year in both the overall MSI system design and in the detailed design of the MSI optics. We have taken a simple panoramic camera and have upgraded it substantially to become a prototype of the MSI flight instrument. The most recent version of the camera utilizes miniature wide-angle optics that image directly onto a 3-color, 2096-element CCD line array. There are several data-taking modes, providing resolution as high as 0.3 mrad/pixel. Analysis tasks that were performed or that are underway with the test data from the prototype camera include the following: construction of 3-D models of imaged scenes from stereo data, first for controlled scenes and later for field scenes; and checks on geometric fidelity, including alignment errors, mast vibration, and oscillation in the drive system. We have outlined a number of tasks planned for Fiscal Year '93 in order to prepare us for submission of a flight instrument proposal for MESUR Pathfinder.

Source record↗

AXAF-I ghost ray study: On orbit case

The problem of baffles for control of singly reflected (and nonreflected) ghost rays is considered. The theory of baffle design for Wolter Type I grazing incidence optics is reviewed, and a set of sample baffle parameters is obtained subject to the assumptions of nominal mirror figures and perfect manufacture and alignment of baffles. It is found that baffles forward of the optics (in the thermal precollimator) and between the mirror elements (at the CAP) are sufficient to allow the simultaneous ghost image and vignetting requirements to be satisfied for HRMA shells P1H1, P3H3, and P4H4. However, these baffles are not sufficient for the innermost shell P6H6; at best the requirements are slightly violated and there is no margin for tolerances. The addition of a baffle interior to the P6 space at an axial station about one third of the way forward from the aft end of the paraboloid will allow the ghost ray and vignetting requirements to be met. The minimum ghost ray angles and the vignetting angles are sensitive functions of the baffle positions and radii; tolerances of considerably better than 1 mm will be required. The sensitivities are coupled and correlated; further investigations should be undertaken in order to obtain baffle parameters which, combined with likely achievable tolerances, will minimize the risk of the vignetting/ghost ray requirements not being met. The lightweight carbon-epoxy composite used for thermal baffles has insufficient X-ray opacity to be a suitable material for construction of the controlling X-ray baffles; further study is needed to determine an appropriate material and to investigate its thermal and mechanical implications.

Gaetz, T. J.↗

Thermal Vacuum Test Performance of the Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) Variable Conductance Heat Pipe Assembly

The Variable Conductance Heat Pipe (VCHP) Assembly of the HST Wide Field Camera 3 was subjected to thermal vacuum (TN) environmental testing. The test program included both maximum and minimum environments as well as simulated on-orbit cycling. Elements of the VCHP assembly included a VCHP, an optical bench cold plate with an imbedded constant conductance heat pipe, and a VCHP reservoir radiator with a proportionally controlled heater. The purpose of the test was to characterize and demonstrate the assembly s ability to control the temperature of the cold plate, which provides a stable thermal environment for the instrument s optical bench. This paper discusses the VCHP Assembly control performance and control authority during the dynamic hot and cold 90-minute orbit cycling test phases.

Cleveland, Paul E.↗

The Laser Astrometric Test of Relativity (LATOR) Mission

This paper discusses new fundamental physics experiment that will test relativistic gravity at the accuracy better than the effects of the second order in the gravitational field strength, proportional to G(sup 2). The Laser Astrometric Test Of Relativity (LATOR) mission uses laser interferometry between two micro-spacecraft whose lines of sight pass close by the Sun to accurately measure deflection of light in the solar gravity. The key element of the experimental design is a redundant geometry optical truss provided by a long-baseline (100 m) multi-channel stellar optical interferometer placed on the International Space Station (ISS). The spatial interferometer is used for measuring the angles between the two spacecraft and for orbit determination purposes. In Euclidean geometry, determination of a triangle s three sides determines any angle therein; with gravity changing the optical lengths of sides passing close by the Sun and deflecting the light, the Euclidean relationships are overthrown. The geometric redundancy enables LATOR to measure the departure from Euclidean geometry caused by the solar gravity field to a very high accuracy. LATOR will not only improve the value of the parameterized post-Newtonian (PPN) gamma to unprecedented levels of accuracy of 1 part in 10(exp 8), it will also reach ability to measure effects of the next post-Newtonian order (c(sup -4)) of light deflection resulting from gravity s intrinsic non-linearity. The solar quadrupole moment parameter, J(sub 2), will be measured with high precision, as well as a variety of other relativistic effects including Lense-Thirring precession. LATOR will lead to very robust advances in the tests of Fundamental physics: this mission could discover a violation or extension of general relativity, or reveal the presence of an additional long range interaction in the physical law. There are no analogs to the LATOR experiment; it is unique and is a natural culmination of solar system gravity experiments.

Turyshev, Slava G.↗

A Slow Retrieval Algorithm for Satellite and Surface Based Instruments

We present results of a retrieval algorithm for satellite and ground based instruments using the Arizona radiative transfer code. A state vector describing the atmospheric and surface condition is iteratively modified until the calculated radiances match the observed values. Elements of the state vector include: aerosol concentrations, radius, optical properties, mass-weighted altitudes, chlorophyll concentration and wind speed. While computationally expensive, many assumptions used in other retrieval algorithms are not invoked. We present co-located retrievals for MODIS, SEAWIFS and nearby AERONET sites. MODIS AQUA and SEA WIFS: Ten MODIS (.412 - 2.110 microns) and eight SEA WIFS (.412-.865 microns) radiances (.412-.865 microns) include channels where aerosols absorb and reflect radiation. We focus on retrieving bio-mass burning aerosols that are advected over open ocean. Since chlorophyll absorbs at frequencies where black carbon absorbs, our retrieval algorithm accounts for chlorophyll absorption by simultaneously retrieving both aerosol and chlorophyll amount. Our retrieved chlorophyll concentrations are similar to those from the Ocean Color Group. AERONET: Both Almucantar and Principle plane radiances are used to retrieve the state of the atmosphere and ocean conditions. Our retrieved aerosol size distributions and optical properties are consistent with the aerosol inversions from the AERONET group.

Weaver, C.↗

Spinoff 2010

Topics covered include: Burnishing Techniques Strengthen Hip Implants; Signal Processing Methods Monitor Cranial Pressure; Ultraviolet-Blocking Lenses Protect, Enhance Vision; Hyperspectral Systems Increase Imaging Capabilities; Programs Model the Future of Air Traffic Management; Tail Rotor Airfoils Stabilize Helicopters, Reduce Noise; Personal Aircraft Point to the Future of Transportation; Ducted Fan Designs Lead to Potential New Vehicles; Winglets Save Billions of Dollars in Fuel Costs; Sensor Systems Collect Critical Aerodynamics Data; Coatings Extend Life of Engines and Infrastructure; Radiometers Optimize Local Weather Prediction; Energy-Efficient Systems Eliminate Icing Danger for UAVs; Rocket-Powered Parachutes Rescue Entire Planes; Technologies Advance UAVs for Science, Military; Inflatable Antennas Support Emergency Communication; Smart Sensors Assess Structural Health; Hand-Held Devices Detect Explosives and Chemical Agents; Terahertz Tools Advance Imaging for Security, Industry; LED Systems Target Plant Growth; Aerogels Insulate Against Extreme Temperatures; Image Sensors Enhance Camera Technologies; Lightweight Material Patches Allow for Quick Repairs; Nanomaterials Transform Hairstyling Tools; Do-It-Yourself Additives Recharge Auto Air Conditioning; Systems Analyze Water Quality in Real Time; Compact Radiometers Expand Climate Knowledge; Energy Servers Deliver Clean, Affordable Power; Solutions Remediate Contaminated Groundwater; Bacteria Provide Cleanup of Oil Spills, Wastewater; Reflective Coatings Protect People and Animals; Innovative Techniques Simplify Vibration Analysis; Modeling Tools Predict Flow in Fluid Dynamics; Verification Tools Secure Online Shopping, Banking; Toolsets Maintain Health of Complex Systems; Framework Resources Multiply Computing Power; Tools Automate Spacecraft Testing, Operation; GPS Software Packages Deliver Positioning Solutions; Solid-State Recorders Enhance Scientific Data Collection; Computer Models Simulate Fine Particle Dispersion; Composite Sandwich Technologies Lighten Components; Cameras Reveal Elements in the Short Wave Infrared; Deformable Mirrors Correct Optical Distortions; Stitching Techniques Advance Optics Manufacturing; Compact, Robust Chips Integrate Optical Functions; Fuel Cell Stations Automate Processes, Catalyst Testing; Onboard Systems Record Unique Videos of Space Missions; Space Research Results Purify Semiconductor Materials; and Toolkits Control Motion of Complex Robotics.

Source record↗

A Broad-Band Phase-Contrast Wave-Front Sensor

A broadband phase-contrast wave-front sensor has been proposed as a real-time wave-front sensor in an adaptive-optics system. The proposed sensor would offer an alternative to the Shack-Hartmann wave-front sensors now used in high-order adaptive-optics systems of some astronomical telescopes. Broadband sensing gives higher sensitivity than does narrow-band sensing, and it appears that for a given bandwidth, the sensitivity of the proposed phase-contrast sensor could exceed that of a Shack-Hartmann sensor. Relative to a Shack-Hartmann sensor, the proposed sensor may be optically and mechanically simpler. As described below, an important element of the principle of operation of a phase-contrast wave-front sensor is the imposition of a 90deg phase shift between diffracted and undiffracted parts of the same light beam. In the proposed sensor, this phase shift would be obtained by utilizing the intrinsic 90 phase shift between the transmitted and reflected beams in an ideal (thin, symmetric) beam splitter. This phase shift can be characterized as achromatic or broadband because it is 90deg at every wavelength over a broad wavelength range.

Bloemhof, Eric↗

Local Leak Detection and Health Monitoring of Pressurized Tanks

An optical gas-detection sensor safely monitors pressurized systems (such as cryogenic tanks) and distribution systems for leaks. This sensor system is a fiber-coupled, solid optical body interferometer that allows for the miniaturized sensing element of the device to be placed in the smallest of recesses, and measures a wide range of gas species and densities (leaks). The deflection of the fringe pattern is detected and recorded to yield the time-varying gas density in the gap. This technology can be used by manufacturers or storage facilities with toxic, hazardous, or explosive gases. The approach is to monitor the change in the index of refraction associated with low-level gas leaks into a vacuum environment. The completion of this work will provide NASA with an enabling capability to detect gas system leaks in space, and to verify that pressurized systems are in a safe (i.e. non-leaking) condition during manned docking and transit operations. By recording the output of the sensor, a time-history of the leak can be constructed to indicate its severity. Project risk is mitigated by having several interferometric geometries and detection techniques available, each potentially leveraging hardware and lessons learned to enhance detectability.

Polzin, Kurt↗

Up Periscope! Designing a New Perceptual Metric for Imaging System Performance

Modern electronic imaging systems include optics, sensors, sampling, noise, processing, compression, transmission and display elements, and are viewed by the human eye. Many of these elements cannot be assessed by traditional imaging system metrics such as the MTF. More complex metrics such as NVTherm do address these elements, but do so largely through parametric adjustment of an MTF-like metric. The parameters are adjusted through subjective testing of human observers identifying specific targets in a set of standard images. We have designed a new metric that is based on a model of human visual pattern classification. In contrast to previous metrics, ours simulates the human observer identifying the standard targets. One application of this metric is to quantify performance of modern electronic periscope systems on submarines.

imaging↗