At least 1,207 records · Page 67

Technology Solutions Case Study: Optimizing Hydronic System Performance in Residential Applications, Ithaca, New York

Condensing boiler technology has been around for many years and has proven to be a durable, reliable method of heating. Based on previous research efforts, however, it is apparent that these types of systems are not designed and installed to achieve maximum efficiency. For example, in order to protect their equipment in the field, manufacturers of low-mass condensing boilers typically recommend design strategies and components that ensure steady, high flow rates through the heat exchangers, such as primary-secondary piping, which ultimately result in decreased efficiency. There is also a significant lack of information for contractors on how to configure these systems to optimize overall efficiency. In response to these findings, researchers from Building America team Consortium for Advanced Residential Buildings worked with industry partners to develop hydronic system designs that would address these issues and result in higher overall system efficiencies and improved response times.

AFUE↗

The M. D. Anderson proton therapy system

Purpose: The purpose of this study is to describe University of Texas M. D. Anderson proton therapy system (PTC-H) including the accelerator, beam transport, and treatment delivery systems, the functionality and clinical parameters for passive scattering and pencil beam scanning treatment modes, and the results of acceptance tests. Methods: The PTC-H has a synchrotron (70-250 MeV) and four treatment rooms. An overall control system manages the treatment, physics, and service modes of operation. An independent safety system ensures the safety of patients, staff, and equipment. Three treatment rooms have isocentric gantries and one room has two fixed horizontal beamlines, which include a large-field treatment nozzle, used primarily for prostate treatments, and a small-field treatment nozzle for ocular treatments. Two gantry treatment rooms and the fixed-beam treatment room have passive scattering nozzles. The third gantry has a pencil beam scanning nozzle for the delivery of intensity modulated proton treatments (IMPT) and single field uniform dose (SFUD) treatments. The PTC-H also has an experimental room with a fixed horizontal beamline and a passive scattering nozzle. The equipment described above was provided by Hitachi, Ltd. Treatment planning is performed using the Eclipse system from Varian Medical Systems and data management is handled by the MOSAIQ system from IMPAC Medical Systems, Inc. The large-field passive scattering nozzles use double scattering systems in which the first scatterers are physically integrated with the range modulation wheels. The proton beam is gated on the rotating range modulation wheels at gating angles designed to produce spread-out-Bragg peaks ranging in size from 2 to 16 g/cm{sup 2}. Field sizes of up to 25x25 cm{sup 2} can be achieved with the double scattering system. The IMPT delivery technique is discrete spot scanning, which has a maximum field size of 30x30 cm{sup 2}. Depth scanning is achieved by changing the energy extracted from the synchrotron (energy can be changed pulse to pulse). The PTC-H is fully integrated with DICOM-RT ION interfaces for imaging, treatment planning, data management, and treatment control functions. Results: The proton therapy system passed all acceptance tests for both passive scattering and pencil beam scanning. Treatments with passive scattering began in May 2006 and treatments with the scanning system began in May 2008. The PTC-H was the first commercial system to demonstrate capabilities for IMPT treatments and the first in the United States to treat using SFUD techniques. The facility has been in clinical operation since May 2006 with up-time of approximately 98%. Conclusions: As with most projects for which a considerable amount of new technology is developed and which have duration spanning several years, at project completion it was determined that several upgrades would improve the overall system performance. Some possible upgrades are discussed. Overall, the system has been very robust, accurate, reproducible, and reliable. The authors found the pencil beam scanning system to be particularly satisfactory; prostate treatments can be delivered on the scanning nozzle in less time than is required on the passive scattering nozzle.

43 PARTICLE ACCELERATORS↗

Reliable SOFC Systems

The goal of this U.S. Department of Energy (DOE) sponsored project was to advance the reliability, robustness and endurance of low-cost SOFC technology suitable for ultimate deployment in ≥100 MWe Integrated Gasification Fuel Cell (IGFC) or Natural Gas Fuel Cell (NGFC) systems capable of ≥97% CO2 capture. The ultimate SOFC program goals are ≤ 0.2% per 1000 hours power degradation over a 5-plus year stack life, high-volume (≥ 250 MW/year) stack production cost of ≤$225/kWsystem net AC, and “power block” (exclusive of fuel supply, contaminant removal, and CO2 capture subsystems) capital cost of ≤ 900/kWsystem net AC (in year 2011). To progress towards the ultimate program goals, the specific objectives of this project were to achieve an SOFC stack power degradation rate of ≤1.5% per 1000 hours in a 100 kW (125 kW Peak) Modular Power Block (MPB) stand-alone power system under thermally self-sustained normal operating conditions and to verify the prospects for high volume SOFC stack production cost below the DOE target of ≤ 225/kW. This final technical report summarizes the progress made during the project period of 36 months. Significant progress was made in the areas of cell and stack technology development, Modular Power Block (MPB) development, sub-MW MPB system development, and MW-class SOFC System Development and Costing. The work focused on areas necessary for comprehensive development of an SOFC fuel cell system, including, active cell improvement, contaminant resistance, process engineering, and development of non-repeat module components. Additionally, several custom built balance-of-plant components were designed and fabricated to support the fuel cell system. SOFC cell and stack development focused on improving cell performance and durability. Enhancements were achieved in areas of electrode stability and impurity tolerance. Additionally, several quality control techniques and tools were developed to ensure predictable and repeatable fabrication of SOFC stacks. Module development continued previous development efforts to achieve footprint reduction and higher efficiency by incorporating balance-of-plant functional equipment into the fuel cell containment module. Several improvements were made to prior design. Control and instrumentation hardware was integrated within the module for serviceability and size reduction. The design efforts culminated in a complete SOFC power plant system. The designed plant was constructed and tested at FCE. Stack and system costs were updated, reflecting advances made in this program.

20 FOSSIL-FUELED POWER PLANTS↗

Durability Research Is Pivotal for Perovskite Photovoltaics

Metal halide perovskite solar cells have shown promising power conversion efficiencies, but commercialization requires that decent durability is also demonstrated. Under normal operation, solar cells are subject to a complex combination of stressors, such as visible light, ultraviolet light, heat, humidity, mechanical stress and electric potential, which complicates the understanding of failure mechanisms. Existing stress tests do not act as a time machine. In new materials systems such as perovskite photovoltaics, the tests have no known relationship to field service. In this Perspective we recommend following a durability learning cycle that interleaves photovoltaic module engineering with field testing; accelerated testing; and preconditioning and performance engineering. We advocate for field testing to demonstrate real-world performance and identify field-relevant failure modes, and urge the community to develop accelerated and qualification tests that account for device metastability, variations in material composition and different/various processing methods. In conclusion, these practices are more difficult, but more important, than the simple pursuit of higher initial efficiencies.

14 SOLAR ENERGY↗

Progress and Strategies for Testing of Materials for Solar Panels

Accelerated testing is key to confident launch of a new product. However, for new products like solar panels, the best approach is not always clear. The challenge for materials manufacturers is that test times can be long. Also, small-coupon testing may not predict the behavior in the full-size module, but testing of the full-size module is too expensive. As a result, solar panel test standards like IEC 61215 are useful, but are not sufficient. Material manufacturers have needed to define their own test protocols. This presentation will review some historical data (e.g., data show that manufacturers are making great progress toward reducing encapsulant discoloration) and describe advances in material testing (for example, new techniques are being demonstrated on how to more quantitatively assess adhesion, detect tendency for delamination, and understand how encapsulant properties affect other properties like cracking of cells). The International PV Quality Assurance Task Force has been researching climate-specific weathering tests toward the goal of defining international standards that would simplify qualification and quality assurance testing for materials. The status of these tests and the strategies for how to organize these standards to best meet the needs of the industry will be discussed.

14 SOLAR ENERGY↗

A Disruptive Approach to Electric Vehicle Power Electronics Final Report

This project developed and demonstrated a new power electronics technology for electric vehicle drivetrains, that achieved significant improvements in power density and efficiency over standard drive cycles, relative to the commercial state of the art. In particular, the prototype measured loss and efficiency curves demonstrated a reduction in total loss over the US EPA US06 drive cycle by a factor of four. Similar reductions are observed for urban (UDDS) and highway (HWFET) drive cycles. Further, the project demonstrated a significant reduction in the total film capacitor requirements, by over an order of magnitude; this was achieved through fundamental improvements in converter circuit topologies. These nonincremental technology advances can lead to significant improvements in temperature rise, reliability, cost, and cooling system size and weight. These results were achieved through a new proposed composite converter architecture, and were demonstrated in a boost-type system similar to that employed by Toyota, Ford, and Honda. A 30 kW silicon prototype achieved a US06 average efficiency of 97.5%, which represents a reduction in average loss by a factor of approximately four relative to the 92.5% average efficiency of the commercial state of the art. A silicon carbide prototype achieved similar efficiency, while also achieving power densities of 23 kW/L (volumetric) and 20 kW/kg (gravimetric) in a boost dc-dc system including magnetics and film capacitors. This was achieved with a SiC switching frequency of 240 kHz, which allowed employment of planar magnetics. These power densities are roughly four times better than the commercial state of the art, and significantly exceed the DOE APEEM 2020 goals. In addition to the composite boost system, a SiC inverter was demonstrated at the 800 V 30 kW level. This inverter was demonstrated driving a permanent magnet machine over the US 06 drive cycle. The replacement of 1200 V Si IGBTs with 1200 V SiC MOSFETs led to improvement of CAFE average efficiency from 98.7% to 99.5%, which corresponds to a reduction of average loss by a factor of approximately two. The modular nature of the composite converter architecture opens the possibility of reuse of one or more converter modules during charging operations, providing a path for onboard charging capability at significant power levels while significantly reducing the volume and weight of the added charger module. This project demonstrated an integrated Level II charger whose add-on specific weight was approximately four times better than the DOE PHEV charger 2022 targets.

33 ADVANCED PROPULSION SYSTEMS↗

Development of a novel quality assurance system based on rolled-up and rolled-out radiochromic films in volumetric modulated arc therapy

Purpose: To develop a cylindrical phantom with rolled-up radiochromic films and dose analysis software in the rolled-out plane for quality assurance (QA) in volumetric modulated arc therapy (VMAT). Methods: The phantom consists of an acrylic cylindrical body wrapped with radiochromic film inserted into an outer cylindrical shell of 5 cm thickness. The rolled-up films with high spatial resolution enable detection of specific dose errors along the arc trajectory of continuously irradiated and modulated beams in VMAT. The developed dose analysis software facilitates dosimetric evaluation in the rolled-up and rolled-out planes of the film; the calculated doses on the corresponding points where the rolled-up film was placed were reconstructed into a rectangular dose matrix equivalent to that of the rolled-out plane of the film. The VMAT QA system was implemented in 3 clinical cases of prostate, nasopharynx, and pelvic metastasis. Each calculated dose on the rolled-out plane was compared with measurement values by modified gamma evaluation. Detected positions of dose disagreement on the rolled-out plane were also distinguished in cylindrical coordinates. The frequency of error occurrence and error distribution were summarized in a histogram and in an axial view of rolled-up plane to intuitively identify the corresponding positions of detected errors according to the gantry angle. Results: The dose matrix reconstructed from the developed VMAT QA system was used to verify the measured dose distribution along the arc trajectory. Dose discrepancies were detected on the rolled-out plane and visualized on the calculated dose matrix in cylindrical coordinates. The error histogram obtained by gamma evaluation enabled identification of the specific error frequency at each gantry angular position. The total dose error occurring on the cylindrical surface was in the range of 5%-8% for the 3 cases. Conclusions: The developed system provides a practical and reliable QA method to detect dosimetric errors according to the gantry angle. Film dosimetry based on rolled-up and rolled-out techniques leads to dose verification in the subspaces of the 3D dose volume. The system can be employed as an alternative tool to detect the pitfalls of planar dose verification.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multileaf Collimator Tracking Improves Dose Delivery for Prostate Cancer Radiation Therapy: Results of the First Clinical Trial

Purpose: To test the hypothesis that multileaf collimator (MLC) tracking improves the consistency between the planned and delivered dose compared with the dose without MLC tracking, in the setting of a prostate cancer volumetric modulated arc therapy trial. Methods and Materials: Multileaf collimator tracking was implemented for 15 patients in a prostate cancer radiation therapy trial; in total, 513 treatment fractions were delivered. During each treatment fraction, the prostate trajectory and treatment MLC positions were collected. These data were used as input for dose reconstruction (multiple isocenter shift method) to calculate the treated dose (with MLC tracking) and the dose that would have been delivered had MLC tracking not been applied (without MLC tracking). The percentage difference from planned for target and normal tissue dose-volume points were calculated. The hypothesis was tested for each dose-volume value via analysis of variance using the F test. Results: Of the 513 fractions delivered, 475 (93%) were suitable for analysis. The mean difference and standard deviation between the planned and treated MLC tracking doses and the planned and without-MLC tracking doses for all 475 fractions were, respectively, PTV D{sub 99%} −0.8% ± 1.1% versus −2.1% ± 2.7%; CTV D{sub 99%} −0.6% ± 0.8% versus −0.6% ± 1.1%; rectum V{sub 65%} 1.6% ± 7.9% versus −1.2% ± 18%; and bladder V{sub 65%} 0.5% ± 4.4% versus −0.0% ± 9.2% (P<.001 for all dose-volume results). Conclusion: This study shows that MLC tracking improves the consistency between the planned and delivered doses compared with the modeled doses without MLC tracking. The implications of this finding are potentially improved patient outcomes, as well as more reliable dose-volume data for radiobiological parameter determination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

UV + Damp Heat Induced Power Losses in Fielded Utility N-Type Si PV Modules

A recent trend in commercial PV modules is a transition to n-type silicon cells, including passivated emitter rear totally diffused (n-PERT), tunnel oxide passivated contact (TOPCon), and silicon heterojunction (SHJ). There is evidence via lab studies that some of these cells are more susceptible to UV induced degradation (UVID), yet there is a lack of confirmation that such degradation occurs in the field. Current IEC standards designed to screen for early module failures require only minimal UV exposure (15 kWh/m2 280-400 nm, ~2-3 months equivalent outdoor exposure). Here, we investigate fielded n-PERT silicon (Si) modules from a commercial utility that show power losses of ~2%/year. We present a comprehensive picture of the physics and chemistry of degradation supported by both module and cell electronic characterization (EL, PL, IV, EQE, and DLIT) and materials-level morphological and chemical analysis (SEM, EDS, XPS, FTIR, and HPLC). All sampled site modules show short circuit current (Isc) and open circuit voltage (Voc) losses when compared to unfielded spares, with the most severely degraded also having losses in fill factor (FF). We identify two different degradation modes contributing to overall power loss: (1) external quantum efficiency (EQE) measurements show losses in the blue range of the spectra, indicative of cell surface recombination losses, and (2) variations in high series resistance (Rs) at the cell level that are correlated with compositional differences in cell metallization. Using unfielded spares, we were able to reproduce Voc, Isc, and EQE losses via a minimum UV stress of 67.5 kWh/m2 (280-400 nm), 4.5x the exposure currently required in IEC 61215-2 (MQT 10). Degradation continued with additional UV dosage equivalent to the fielded modules (405 kWh/m2 total), with power loss leveling out at an average of 6.1%. Subsequent 1000 h of 85% RH/85degrees C damp heat testing showed that cells exposed to UV underwent additional severe series resistance degradation, even those without the susceptible paste composition seen in the field, whereas non-UV exposed cells saw little change. We attribute this to higher concentrations of acetic acid generated on the UV exposed area of the module, leading to degradation of the gridline/cell interface and high Rs. This study is unique in that it reproduces field observed utility scale UVID with an accelerated test and supports the need for standards development for longer UV exposure combined with other stress factors to catch materials interplay within a module package.

14 SOLAR ENERGY↗

Durability of Polymeric Encapsulation Materials for Concentrating Photovoltaic Systems (Presentation)

Many concentrating photovoltaic (CPV) systems use a polymeric encapsulant to couple and optical component and/or coverglass to the cell. In that location, the encapsulation improves the transmission of concentrated optical flux through interface(s), while protecting the cell from the environment. The durability of encapsulation materials, however, is not well established relative to the desiredservice life of 30 years. Therefore, we have initiated a screen test to identify the field-induced failure modes for a variety of popular PV encapsulation materials. An existing CPV module (with no PV cells present) was modified to accommodate encapsulation specimens. The module (where nominal concentration of solar flux is 500x for the domed-Fresnel design) has been mounted on a tracker inGolden, CO (elevation 1.79 km). Initial results are reported here for 18 months cumulative exposure, including the hottest and coldest months of the past year. Characteristics observed at intervals during that time include: visual appearance, direct and hemispherical transmittance, and mass. Degradation may be assessed from subsequent analysis (including yellowness index and cut-on frequency)relative to the ambient conditions present during field exposure. The fluorescence signature observed of all the silicone specimens is examined here, including possible factors of causation -- the platinum catalyst used in the addition cured materials as well as the primer used to promote adhesion to the quartz substrate and superstrate.

14 SOLAR ENERGY↗

Towards Cooperative Control of Humanoid Robots for Handling High-Consequence Materials in Gloveboxes - 17291

In this paper, we describe our ongoing work with NASA's Valkyrie humanoid robot and present preliminary results on cooperative control of Valkyrie's hands for performing dexterous manipulation tasks inside gloveboxes commonly found in many nuclear facilities. First, we discuss our human-supervised robot control framework which is based on optimization-based whole-body motion and manipulation controllers. A key aspect of this approach is perception based grasping. We develop a grasping control module for realizing the grasps corresponding to sample tasks such as power, ball, key, pinch, and open palm grasps and their variations. Next, we introduce the notion of motion template library in order to develop generalizable robot grasping and manipulation. Motion template library stores the constraint setting information for the constrained motion planning methods and a framework which can implement the motion template library on different types of robots for accomplishing similar tasks. Motion templates are defined only based on the task requirements. As a result, they can be easily ported to different robot platforms. Lastly, we discuss our multi-modal interfaces designs which include a visual display for improved situational awareness as well as a tactile glove for robot hand control and feedback. Our goal is for the person tele-operating the Valkyrie robot to have better sensing and control than what he or she would have if actually standing at the glovebox doing the work. This improved sensing is comprised of the ability to 'see through' the robot's arms and hands in the gloves and to have an improved sense of touch. The paper concludes with a discussion of our validation strategy. Our success metrics are derived from the completion of a relatively complex experiment to be performed in the glovebox. We evaluate various realistic experiments and use them for task validation and demonstration with Valkyrie. We use speed, time of completion, accuracy, repeatability and reliability rates as success metrics by designing replicable experiments. (authors)

42 ENGINEERING↗

Durability of Polymeric Encapsulation Materials for Concentrating Photovoltaic Systems (Presentation)

Many concentrating photovoltaic (CPV) systems use a polymeric encapsulant to couple and optical component and/or coverglass to the cell. In that location, the encapsulation improves the transmission of concentrated optical flux through interface(s), while protecting the cell from the environment. The durability of encapsulation materials, however, is not well established relative to the desired service life of 30 years. Therefore, we have initiated a screen test to identify the field-induced failure modes for a variety of popular PV encapsulation materials. An existing CPV module (with no PV cells present) was modified to accommodate encapsulation specimens. The module (where nominal concentration of solar flux is 500x for the domed-Fresnel design) has been mounted on a tracker in Golden, CO (elevation 1.79 km). Initial results are reported here for 18 months cumulative exposure, including the hottest and coldest months of the past year. Characteristics observed at intervals during that time include: visual appearance, direct and hemispherical transmittance, and mass. Degradation may be assessed from subsequent analysis (including yellowness index and cut-on frequency) relative to the ambient conditions present during field exposure. The fluorescence signature observed of all the silicone specimens is examined here, including possible factors of causation -- the platinum catalyst used in the addition cured materials as well as the primer used to promote adhesion to the quartz substrate and superstrate.

14 SOLAR ENERGY↗

Confidentiality-preserving machine learning algorithms for soft-failure detection in optical communication networks

Automated fault management is at the forefront of next-generation optical communication networks. The increase in complexity of modern networks has triggered the need for programmable and software-driven architectures to support the operation of agile and self-managed systems. In these scenarios, the European Telecommunications Standards Institute zero-touch network and service management approach is imperative. The need for machine learning algorithms to process the large volume of telemetry data brings safety concerns as distributed cloud-computing solutions become the preferred approach for deploying reliable communication network automation. This paper’s contribution is twofold. First, we propose a simple yet effective method to guarantee the confidentiality of the telemetry data based on feature scrambling. The method allows the operation of third-party computational services without direct access to the full content of the collected data. Additionally, the effectiveness of four unsupervised machine learning algorithms for soft-failure detection is evaluated when applied to the scrambled telemetry data. The methods are based on factor analysis, principal component analysis, nonlinear principal component analysis, and singular value decomposition. Most dimensionality reduction algorithms have the common property that they can maintain similar levels of fault classification performance while hiding the data structure from unauthorized access. Evaluations of the proposed algorithms demonstrate this capability.

97 MATHEMATICS AND COMPUTING↗

Comparison of breakdown-voltage of contemporary and veteran photovoltaic backsheets

The ability of designated electrically insulating materials in a module, including the backsheet, to act as insulators is a key safety requirement for photovoltaic technology. The recently developed test standards IEC TS 62788-2 (including a method for direct-current breakdown-voltage) and IEC TS 62788-7-2 (for ultraviolet [UV] weathering) are examined for the first time together in this study. Thirty-six contemporary backsheets were compared using the breakdown-voltage test, before and after UV weathering, according to the recent A3 test condition. Twenty-eight backsheets, extracted from a variety of veteran photovoltaic modules, were also examined using the breakdown test. Additional characterizations were performed to interpret the breakdown-voltage results, including: surface and cross-sectional optical microscopy failure analysis; cross-sectional scanning electron (SEM) microscopy with EDS energy-dispersive X-ray spectroscopy (EDX) failure analysis; Fourier-transform infrared spectroscopy (FTIR) to identify the base resin and its chemical integrity; and differential scanning calorimetry (DSC) to identify phase transitions that might adversely affect degradation during weathering. The electrical insulation for the backsheets is discussed relative to: the industry safety requirement; features observed to facilitate the degradation of insulation; the validity of the artificial UV weathering test; the validity of the sheet geometry used for specimens in this study; and the validity of subsequent mechanical testing.

14 SOLAR ENERGY↗

SU-F-T-212: A Comparison of Treatment Strategies for Intracranial Stereotactic Radiosurgery

Purpose: Stereotactic radiosurgery is an effective and noninvasive treatment for intracranial lesions that uses highly focused radiation beams in a single treatment fraction. The purpose of this study is to investigate the dosimetric differences between the treatment brain metastasis with a proton beam vs. intensity modulated radiation therapy (IMRT). Methods: Ten separate brain metastasis targets where chosen and treatment plans were created for each, using three different strategies: custom proton beam shaping devices, standardized proton beam shaping devices, and IMRT. Each plan was required to satisfy set parameters for providing adequate coverage and minimizing risk to adjacent tissues. The effectiveness of each plan was calculated by comparing the homogeneity index, conformity index, and V12 for each target using a paired one tailed T-test (α=0.05). Specific comparison of the conformity indices was also made using a subcategory containing targets with volume>1cc. Results: There was no significant difference between the homogeneity indices of the three plans (p>0.05), showing that each plan has the capability of adequately covering the targets. There was a statistically significant difference (p<0.01) between the conformity indices of the custom and the standard proton plan, as with the custom proton and IMRT (p<0.01), with custom proton showing stronger conformity to the target in both cases. There was also a statistical difference between the V12 of all three plans (Custom v. Standardized: p=0.02, Custom v. IMRT: p<0.01, Standardized v. IMRT: p<0.01) with custom proton supplying the lowest dose to surrounding tissues. For large targets (volume>1cc) there was no statistical difference between the proton plans and the IMRT treatment for the conformity index. Conclusion: A custom proton plan is the recommended treatment explored in this study as it is the most reliable way of effectively treating the target while sparing the maximum amount of normal tissue.

60 APPLIED LIFE SCIENCES↗

The HUNTER Dynamic Human Reliability Analysis Tool: Coupling an External Plant Code

The Human Unimodel for Nuclear Technology to Enhance Reliability (HUNTER) is a framework to support dynamic human reliability analysis (HRA) with the aim to develop standalone software to perform the dynamic HRA calculations. Within the HRA, human actions in nuclear power plants (NPPs) are predicated by plant states, and human actions influence the plant. In other words, plant operations are necessarily recursive, and it becomes challenging to model complex human-plant interactions. Consequently, we have linked two software simulations that complement those shortcomings. RELAP5-3D—the Reactor Excursion and Leak Analysis Program (RELAP; Aumiller, Tomlinson, and Bauer 2001) is the foundational thermal-hydraulic software used to model nuclear systems. Using RELAP5-3D, we have simulated the plant operations proceeding according to procedures developed to address emergent situations in NPPs. Plant operations include various actions such as the operator checking plant parameters, as well as actions that are continuously performed over time until a specific parameter reaches certain criteria. That means that HUNTER and RELAP5-3D exchange information with each other and should be carried out simultaneously over time. To simulate plant operations, which represent the actual operator checks of plant parameters and corresponding manual control actions, changes in plant status are identified through simulation and performed according to the criteria and order of the procedure. Thus, the goal of coupling HUNTER with RELAP5-3D is to facilitate synchronous coupling, where human and plant models provide iterative feedback loops that drive the course of actions. The advantage of coupling with RELAP5-3D to serve as the external environment module in HUNTER is the ability to customize the plant model and streamline for particular model applications. In this paper, we will address the key features of the coupling and the coupling structure built to perform the feedback loops.

99 GENERAL AND MISCELLANEOUS↗

Degradation in PV Encapsulation Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.

14 SOLAR ENERGY↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗