Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

The Effects of Hygrothermal Aging on the Impact Penetration Resistance of Triaxially Braided Composites

An experimental study was conducted to measure the effects of long term hygrothermal aging on the impact penetration resistance of triaxially braided polymer composites. Flat panels of three different materials were subjected to repeated cycles of high and low temperature and high and low humidity for two years. Samples of the panels were periodically tested under impact loading during the two year time period. The purpose of the study was to identify and quantify any degradation in impact penetration resistance of these composites under cyclic temperature and humidity conditions experienced by materials in the fan section of commercial gas turbine engines for a representative aircraft flight cycle. The materials tested consisted of Toray ® T700S carbon fibers in a 2D triaxial braid with three different resins, Cycom® PR520, a toughened resin, Hercules® 3502, an untoughened resin and EPON 862, intermediate between the two. The fiber preforms consisted of a quasi-isotropic 0/+60/-60 braid with 24K tows in the axial direction and 12K tows in the bias directions. The composite panels were manufactured using a resin transfer molding process producing panels with a thickness of 0.125 inches. The materials were tested in their as-processed condition and again after one year and two years of aging (1.6 years in the case of E862). The aging process involved subjecting the test panels to two cycles per day of high and low temperature and high and low humidity. A temperature range of -60degF to 250degF and a humidity range of 0 to 85% rh was used to simulate extreme conditions for composite components in the fan section of a commercial gas turbine engine. Additional testing was conducted on the as-processed PR520 composite under cryogenic conditions. After aging there was some change in the failure pattern, but there was no reduction in impact penetration threshold for any of the three systems, and in the case of the 3502 system, a significant increase in penetration threshold. There was also an increase in the penetration resistance of the PR520 system impacted under cryogenic conditions.

composite↗

Comparisons of Mixed-Phase Icing Cloud Simulations with Experiments Conducted at the NASA Propulsion Systems Laboratory

This paper builds on previous work that compares numerical simulations of mixed-phase icing clouds with experimental data. The model couples the thermal interaction between ice particles and water droplets of the icing cloud with the flowing air of an icing wind tunnel for simulation of NASA Glenn Research Centers (GRC) Propulsion Systems Laboratory (PSL). Measurements were taken during the Fundamentals of Ice Crystal Icing Physics Tests at the PSL tunnel in March 2016. The tests simulated ice-crystal and mixed-phase icing that relate to ice accretions within turbofan engines. Experimentally measured air temperature, humidity, total water content, liquid and ice water content, as well as cloud particle size, are compared with model predictions. The model showed good trend agreement with experimentally measured values, but often over-predicted aero-thermodynamic changes. This discrepancy is likely attributed to radial variations that this one-dimensional model does not address. One of the key findings of this work is that greater aero-thermodynamic changes occur when humidity conditions are low. In addition a range of mixed-phase clouds can be achieved by varying only the tunnel humidity conditions, but the range of humidities to generate a mixed-phase cloud becomes smaller when clouds are composed of smaller particles. In general, the model predicted melt fraction well, in particular with clouds composed of larger particle sizes.

Thermal model↗

Influence of Deep Convection on Cirrus and Water Vapor Concentration in the Upper Troposphere and Lower Stratosphere

It is well known that stratospheric humidity is primarily controlled by freeze drying (ice crystal growth and sedimentation) of air ascending across the cold tropical tropopause. However, the suggestion of an important source of water vapor from deep convection that extends above the tropical tropopause has persisted. There exists much anecdotal evidence of direct convective hydration of the lower stratosphere based on measurements from high altitude aircraft campaigns, but quantifying the impact of deep convection on the overall budget of stratospheric water vapor has proven challenging. The role of convection on the humidity of the upper troposphere and lower stratosphere (UTLS) is investigated in simulations of cirrus clouds along trajectories launched from given potential temperature level surfaces. The one-dimensional (vertical) cloud model tracks individual ice crystals through their life cycles, beginning with nucleation or detrainment from convection, followed by deposition growth, sedimentation and sublimation. Convective influence of the parcels is diagnosed by tracing the trajectories through time-dependent fields of convective cloud-top height adjusted to match the CloudSAT and CALIPSO statistics. Model simulations of UTLS water vapor and cloud fields are evaluated and constrained by comparison with MLS and CALIPSO measurements. The simulation results indicate that the overall impact of convection on water vapor near the tropical tropopause is 10-15%, while the impact on lower stratospheric humidity is no more than a few percent. Ice crystals detrained from deep convection have relatively small effect. The general implications for the importance of deep convection on UTLS humidity and cirrus cloud fraction will be discussed.

Ueyama, Rei↗

Use of three-cornered hat error estimates in MERRA-2 to guide an improved reanalysis-Part 1

The three-cornered hat (3CH) method estimates the uncertainties of three different co-located model or observational data sets (Anthes and Rieckh, 2018; Sjoberg et al., 2021). Rieckh et al. (2021) used the 3CH method to compare the random error statistics of different global forecast and reanalysis models, as well as radio occultation (RO) and radiosonde observations. That study showed that the MERRA-2 reanalysis, while having smaller errors in the stratosphere than its predecessor MERRA, had larger errors in the troposphere than many of the other data sets analyzed. The MERRA-2 errors were particularly large in the tropics. In a collaborative effort between UCAR’s COSMIC (Constellation Observing System for Meteorology, Ionosphere and Meteorology) program and NASA’s Global Modeling and Assimilation Office (GMAO), we carried out further 3CH error diagnostics to help isolate the causes of these larger errors and help guide the development of an improved reanalysis. This presentation summarizes random error statistics associated with MERRA-2, ECMWF’s ERA5 reanalysis, and COSMIC-2 (C2) RO observations. We compute 3CH error variance estimates of refractivity, as well as temperature and specific humidity using UCAR’s COSMIC Data Analysis and Archive Center (CDAAC) improved 1D-variational (1D-Var) retrieval (wetPf2) over 15 latitude bands from 45S to 45N. The 1D-Var retrievals of specific humidity and temperature for C2 use NCEP’s Global Forecast System (GFS) as the background. Anthes et al. (2021) showed that it gives accurate estimates of temperature and specific humidity in the tropics and subtropics, even in the challenging environment of intense Hurricane Dorian (2019). This presentation confirms the previous results that MERRA-2 has significantly larger errors in the tropics and subtropics than either C2 or ERA5. Its errors are larger between 30S and 30N compared to 30-45 N-S latitudes, and are also larger over land compared to oceans. Most of the MERRA-2 refractivity errors come from specific humidity, except over land below 3 km where temperature errors are large. These results suggest that moist convection and atmospheric boundary layer physics in MERRA-2 may be responsible for a significant part of the higher uncertainties. These results are being used to guide GMAO in developing an improved next-generation reanalysis, as shown in a companion presentation submitted to this conference (El Akkraoui et al., 2021), which extends this study and describes improvements to MERRA-2 leading to the next GMAO reanalysis.

Jeremiah Sjoberg↗

Tribological performance of Al2O3-B2O3 composites: Role of CuOand CaO constituents

Al2O3-B2O3 based composites for wear resistant applications (e.g., seal rings and bearings) were manufactured using powder metallurgy route. Four different compositions were considered to control amount of in situ phases, mainly aluminum borate, formed during sintering. The fabricated composites were characterized using X-ray diffraction to identify the phases. Hardness was measured in terms of micro-hardness. The tribological performance of the composites were evaluated by conducting dry sliding tests against alumina balls at different humidity levels (10 – 95% relative humidity). The X-ray spectrum revealed that increase in B2O3 content in the composites increased the amount of aluminum borate phase that enhanced the micro-hardness. Results revealed that aluminum borate enhanced the wear resistance of the composites, whereas the humidity-sensitive alumina phase reduced friction at higher humidity levels. Furthermore, CuO and CaO (2-5 wt.%) were added separately to the composite, resulting in increased density by 22-48 %. Athough the addition of CuO and CaO led to increase in hardness and wear resistance of the composites, the coefficient of friction was negatively affected. The friction and wear performance along with wear mechanism are discussed with respect to observed phases in the composites.

Ashish K. Kasar↗

Leveraging Pre-storm Soil Moisture Estimates for Enhanced Land Surface Model Calibration in Ungauged Hydrologic Basins

Despite long-standing efforts, hydrologists still lack robust tools for calibrating land surface model (LSM) streamflow estimates within ungauged basins. Using surface soil moisture estimates from the Soil Moisture Active Passive Level 4 Soil Moisture (L4_SM) product, precipitation observations, and streamflow gauge measurements for 617 medium-scale (200-10,000 km2) basins in the contiguous United States, we measure the temporal (Spearman) rank correlation between antecedent (i.e., pre-storm) surface soil moisture (ASM) and the storm-scale runoff coefficient (RC; the fraction of storm-scale precipitation accumulation converted into streamflow). In humid and semi-humid basins, this rank correlation is shown to be sufficiently strong to allow for the substitution of storm-scale RC observations (available only in basins that are both lightly regulated and gauged) with high-quality ASM values (available quasi-globally from L4_SM) in streamflow calibration procedures. Using this principle, we define a new, basin-wise LSM streamflow calibration approach based on L4_SM alone and successfully apply it to identify LSM configurations that produce a high rank correlation with observed RC. However, since the approach cannot detect RC bias, it is less successful in identifying LSM configurations with low mean-absolute error. Plain Text Summary Accurately forecasting the fraction of rainfall that runs off into streams, as opposed to infiltrates into the soil, is critical for flash-flood prediction, water-resource monitoring, and tracking the transport of nutrients from agricultural fields into local waterways. Such forecasting is typically performed by hydrologic models that attempt to represent the physical processes responsible for surface runoff generation. However, to provide accurate streamflow forecasts, these models typically need to be calibrated against actual streamflow observations. This is problematic given the relatively poor, and declining, global availability of stream gauges. This paper presents a novel model calibration strategy that uses soil moisture from remote sensing and numerical modeling in place of streamflow observations during calibration. This transition has significant practical advantages because, unlike streamflow observations, the soil moisture data are continuously available across space. Our results demonstrate that this new approach can significantly improve hydrologic models within humid and semi-humid basins lacking sufficient ground-based instrumentation for traditional streamflow calibration.

hydrologic models↗

Rapid Cycle Amine 4.0 System Development

Carbon dioxide (CO2) and humidity control is a key function of the spacesuit Portable Life Support Subsystem (PLSS). The latest spacesuit design utilizes a pressure swing bed containing a solid amine sorbent to scrub CO2 and humidity produced by the crewmember from the ventilation loop. The solid amine sorbent removes CO2 and humidity from the ventilation loop through a chemisorption mechanism. Simultaneously, CO2 and humidity are desorbed to vacuum via the two-bed pressure swing system during operation. This continuous regeneration allows for longer Extravehicular Activity (EVA) times while minimizing maintenance, consumables, and power usage. This concept has been in development for over 20 years, during which many prototypes and design iterations have been fabricated and evaluated. This paper discusses the recent Rapid Cycle Amine (RCA) design, development, and testing that has been done to advance the technology. The most recent fabrication is the RCA 3.0. It was delivered to NASA Johnson Space Center in 2015 and has since been tested at the component level and at the integrated PLSS level. The purpose of the component level testing was to understand CO2 removal capacity, end-of-life performance, and establish a baseline performance prior to integrated testing. The RCA 3.0 was integrated into the Exploration Extravehicular Mobility Unit (xEMU) PLSS for a comprehensive Design Verification Test (DVT) series. The integrated testing provided the benefit of characterizing the impact performance degradation has on the system. Many of the RCA requirements were developed through analysis, based on the limitations of the PLSS and, in some cases, assumptions about the system and flow behavior. Integrated testing was an opportunity to validate those requirements and assumptions. While the RCA 3.0 was being tested, the next design iteration, RCA 4.0, was under development. The RCA 4.0 preliminary design phase began in late-2019 and shortly after the Preliminary Design Review, the critical design phase began in 2021. The design work has concluded with the completion of a Pre-Manufacturing Review in 2022. This paper provides an overview of the RCA 4.0 system design, summarizes the results of integrated RCA 3.0 testing, and discusses the pertinence of driving requirements such as mass, volume, and power consumption.

Kelsey Bloom↗

A Path to Improving Simulated Properties of Low Clouds over the Beaufort Sea using Airborne In Situ Observations of Subgrid-Scale Variability

Arctic low clouds influence the evolution of the Arctic system through their effects on radiative fluxes, boundary layer mixing, stability, turbulence, humidity, and precipitation. Unfortunately, atmospheric models and retrospective analysis (reanalysis) products struggle to accurately simulate the occurrence and properties of low clouds in the Arctic. One of the main reasons for this problem are the possible unrealistic assumptions that models/reanalyses make about the subgrid-scale (SGS) variability of meteorological properties, as well as the relationship between SGS variability and grid-scale (GS) cloud properties. We utilize cloud and thermodynamic data of low level (primarily) liquid clouds collected from two aircraft campaigns conducted over the Beaufort Sea to better understand and characterize this problem. Examining data from the September 2014 Arctic Radiation-IceBridge Sea and Ice Experiment (ARISE) airborne campaign and the 1998 First International Satellite Cloud Climatology Project (ISCCP) Regional Experiment (FIRE)–Arctic Cloud Experiment (ACE) reveals that GS cloud water variability is closely related with SGS distribution of total water (i.e. water vapor + cloud water). We investigate two related approaches to prediction of GS cloud properties from SGS variability: the critical saturation ratio method, and the critical relative humidity method. We find significant correlation between GS cloud water and SGS supersaturation when the critical saturation ratio is set at 100%, as well as a notable relationship between GS cloud water and the width of the SGS total water distribution. Critical relative humidity also compares well with GS cloud water. However, we also find that the assumptions of a static critical saturation ratio of 100% to be unrealistic, as well as a fixed SGS distribution width. Empirical calculations from the ARISE data show a large sensitivity of these SGS variables to GS relative humidity, and so a SGS parameterization allowing them to vary according to GS thermodynamic properties may result in more realistic GS cloud water values.

J. Brant Dodson↗

Vermont Wildland Fires: Investigating the Role of Antecedent Conditions and Recent Environmental Trends in Exacerbating Fire Risk and Potential in Vermont

Under a changing climate, increases in dry conditions and extreme heat events are projected to exacerbate wildfire risk in the northeastern U.S. In recent years, Vermont has observed higher annual temperatures, more frequent heatwaves, increased annual precipitation, extreme flood events, and decreased snowfall. The mechanisms through which environmental factors contribute to increased fire risk in humid environments, such as Vermont, are poorly understood. The team partnered with the National Weather Service, the Vermont Division of Forests, and the University of Vermont to investigate phenological trends and antecedent conditions influencing wildland fire risk. For the phenological analysis, from 2001 to 2023, vegetation data, phenological dates, and snow water equivalent (SWE) values were accessed from Landsat 5Thematic Mapper (TM), Landsat 7Enhanced Thematic Mapper Plus (ETM+), Landsat 8Operational Land Imager (OLI), Landsat 9OLI-2, the Moderate Resolution Imaging Spectroradiometer (MODIS), and the Snow Data Assimilation System (SNODAS), respectively. For the antecedent condition analysis, from 2008 to 2023, soil moisture, Environmental Stress Index, wind speed, minimum relative humidity, and daily precipitation data were obtained from the Global Land Data Assimilation System (GLDAS), SERVIR, gridMET Wind, gridMET Humidity, and NClimGrid, respectively. The study found that green-up dates over the study period remain relatively stable, while snowmelt dates appear increasingly variable. Minimum relative humidity was the most significant environmental variable correlated with wildfire risk in Vermont. Results from this study will inform the National Weather Service's preparation of fire forecasts before prescribed burns and support community outreach by the Vermont Agency of Natural Resources.

Wildland Fire↗

Air Sample Conditioner Helps the Waste Treatment Plant Meet Emissions Standards

The air in three of the Hanford Site Waste Treatment and Immobilization Plant (WTP) melter off-gas discharge stacks will be hot and humid after passing through the train of emission abatement equipment. The off-gas temperature and humidity levels will be incompatible with the airborne emissions monitoring equipment required for this type of stack. To facilitate sampling from these facilities, an air sample conditioner system will be installed to introduce cool, dry air into the sample stream to reduce the temperature and dew point. This will avoid thermal damage to the instrumentation and problematic condensation. The complete sample transport system must also deliver at least 50% of the particles in the sample airstream to the sample collection and on-line analysis equipment. The primary components of the sample conditioning system were tested in a laboratory setting. The sample conditioner itself is based on a commercially-available porous tube filter design. It consists of a porous sintered metal tube inside a coaxial metal jacket. The hot gas sample stream passes axially through the porous tube, and the dry, cool air is injected into the jacket and through the porous wall of the inner tube, creating an effective sample diluter. The dilution and sample air mix along the entire length of the porous tube, thereby simultaneously reducing the dew point and temperature of the mixed sample stream. Furthermore, because the dilution air enters through the porous tube wall, the sample stream does not come in contact with the porous wall and particle deposition is reduced in this part of the sampling system. Tests were performed with an environmental chamber to supply air with the temperature and humidity needed to simulate the off-gas conditions. Air from the chamber was passed through the conditioning system to test its ability to reduce the temperature and dew point of the sample stream. To measure particle deposition, oil droplets in the range of 9 to 11 micrometer aerodynamic diameter were injected into the environmental chamber and drawn through the conditioning system, which included a filter to capture droplets that passed through the conditioner. The droplets were tagged with a fluorescent dye which allowed quantification of droplet deposition on each component of the system. The tests demonstrated the required reductions in temperature and moisture, with no condensation forming when heat tracing was added on the upstream end of the sample conditioner. Additionally, tests indicated that the system, operating at several flow rates and in both vertical and horizontal orientations, delivers nearly all of the sampled particles for analysis. Typical aerosol penetration values were between 98 and 99%. PNNL, Bechtel National Inc., and the instrument vendor are working to implement the sample conditioner into the air monitoring systems used for the melter off-gas exhaust streams. Similar technology may be useful for processes in other facilities with air exhaust streams with elevated temperature and/or humidity.

sample conditioning↗

Gas Engine-Driven Heat Pump with Desiccant Dehumidification

About 40% of total U.S. energy consumption was consumed in residential and commercial buildings. Improved air-conditioning technology has by far the greatest potential impact on the electric industry compared to any other technology that uses electricity. This paper describes the development of an innovative natural gas, propane, LNG or bio-gas IC engine-driven heat pump (GHP) with desiccant dehumidification (GHP/DD). This integrated system has higher overall efficiencies than conventional equipment for space cooling, addresses both new and existing commercial buildings, and more effectively controls humidity in humid areas. Waste heat is recovered from the GHP to provide energy for regenerating the desiccant wheel and to augment heating capacity and efficiency. By combining the two technologies, an overall source COP of greater that 1.5 (hot, humid case) can be achieved by utilizing waste heat from the engine to reduce the overall energy required to regenerate the desiccant. Moreover, system modeling results show that the sensible heat ratio (SHR- sensible heat ratio) can be lowered to less 60% in a dedicated outdoor air system application with hot, humid cases.

dessicant coupled air conditioning system↗

Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) Winter Intensive Operational Period: Aerodynamic Particle Sizer Field Campaign Report

An aerodynamic particle sizer spectrometer (APS, model 3321 by TSI Inc., Shoreview, Minnesota) was deployed at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Eastern North Atlantic (ENA) observatory during the second (winter) intensive operational period (IOP) of the Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) field campaign. Data were collected from January 9 through February 26, 2018, covering the second deployment of the ARM Aerial Facility (AAF) aircraft within ACE-ENA. The standard ENA instrument suite does not provide measurements of aerosol particle size distribution for diameters greater than one micron. Properties of coarse-mode (super-micron) aerosols are rarely measured, although super-micron particles can play an important role in the aerosol life cycle, affecting aerosol optical properties and cloud nuclei activity (e.g., Clarke et al. 2003). The APS was deployed to fill this gap in particle size measurements: it is capable of measuring size-resolved concentration of the aerosols in the 0.5-20 μm range (aerodynamic diameter). The APS was installed in the aerosol trailer to sample through the main stack. Special attention was given to selection of the instrument location (just below the main stack) to minimize particle losses in the connecting lines. Most atmospheric aerosols are hygroscopic, so the measurement of the aerosol size distributions should either be performed in a controlled humidity environment or accompanied by concurrent measurement of the temperature and humidity of the sample air. The latter strategy was used during this deployment: a high-precision humidity/temperature transmitter (model EE08 by E+E Elektonik GMBH, Engerwitzdorf, Germany) was mounted in the APS sampling line immediately upstream of the APS inlet. A dedicated laptop computer was used for data collection and communications. The APS was controlled with vendor-supplied software (Aerosol Instrument Manager, ver. 10.1, TSI); aerosol size distribution data were collected over a period of 55 seconds and converted to one-minute averages. Temperature and humidity analog signals were acquired via analog-to-digital converter (ADC) module (model WTAIN-M by Weeder Technologies, Fort Walton Beach, Florida) using vendor-supplied software (ModCom) with 1- sec resolution. In post-processing, the APS data were exported from TSI proprietary format into “comma-separated value” American Standard Code for Information Interchange (ASCII) files and matched with appropriately averaged temperature and humidity data. Two significant periods of missing data were caused by local power outages. Vendor-supplied software was not designed for unattended operation: it needs to be manually restarted including sensor configuration setup.

ACE-ENA, Azores, ultra-high-sensitivity aerosol sp↗

Evaporation-driven engines

Evaporation-driven engines are disclosed herein. An example engine can include a water source having a high humidity zone proximate the surface of the water source, a supporting structure, and a hygroscopic material disposed on the supporting structure and configured to generate mechanical force in response to a changing relative humidity. The hygroscopic material can be repeatedly exposed to the high humidity zone and removed from the high humidity zone thereby causing the hygroscopic material to generate mechanical force.

Chen, Xi↗

Adaptive Water-Resistive Barrier for Building Envelopes

Excessive moisture transport into building enclosures can lead to elevated moisture levels in wall cavities and associated damage. Such conditions can also produce increased energy consumption. Currently, architects and builders are limited to using static membranes as water-resistive barriers that exhibit a single vapor permeance irrespective of environmental conditions. Membranes with a high permeance may allow moisture ingression under hot and humid ambient conditions, while membranes with a low permeance may not allow wall cavities to dry out when moisture accumulates within them.An electrostatically actuated, dual permeance membrane previously demonstrated for protective apparel is under development for use as a water-resistive barrier for building envelopes. When outdoor temperature and relative humidity are high as detected by sensors, the membrane exhibits low permeance (~0.5 perms) to inhibit water vapor ingression into the building enclosure; but when humidity in the wall cavity is high, the membrane exhibits high permeance (~50 perms) to facilitate water vapor egression to the outside. The membrane changes state by electrostatic actuation using a very low current electrical power supply.In order to quantify the benefits of a dual permeance water-resistive barrier, WUFI® hygrothermal modeling simulations were completed comparing the adaptive membrane to conventional fixed permeance membranes relative to inhibiting mold growth for various US climates and several wall constructions. The WUFI® code was modified to accommodate switching the permeance of the adaptive membrane between low and high permeance states for several humidity setpoint control strategies. The effect of liquid water leakage into the wall cavity was also considered.This report summarizes the initial steps in development of dual permeance, electrostatically actuated water-resistive barriers focusing on the results of hygrothermal model simulations of these adaptive structures and testing of subscale adaptive structures to demonstrate the capability of the technology to achieve the preferred permeance levels suggested by the modeling.

Trentacosta, Joseph↗

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The effect of barrier films and exposure on the aging of vacuum insulation panels with fumed silica cores

Vacuum insulation panels have very low thermal conductivities compared to conventional insulation materials. The reduction of the core pressure significantly lowers gas phase conduction and overall thermal conductivity. As a consequence, increases in gas pressure can significantly increase thermal conductivity of the VIP. In addition, the thermal conductivity of the core is sensitive to moisture content. For vacuum insulation panels with fumed silica cores, work shows that the measured thermal conductivity increases by 0.5 x 10-3 W/mK per mass percent increase in water content [1]. This is significant since the thermal conductivity of vacuum insulation panels with fumed silica cores is in the range of 0.004 W/mK. This work investigates the long-term behavior of vacuum insulation panels comprised of fumed silica cores with polymer (ethylene vinyl alcohol) and metalized (aluminized) barrier films exposed to different exposure conditions: ambient conditions; exterior conditions in a mixed humid climate; and 24oC and 80 percent relative humidity. Results show that the increase in thermal conductivity is more pronounced for vacuum insulation panels made using polymer barrier films compared to the same panel protected by a metalized film. The increase is more pronounced when exposed to high relative humidity, 80 percent. After almost two years exposure, the decrease in thermal conductivity for vacuum insulation panels protected by a metalized barrier films are between 4 and 11 percent depending on exposure condition. The smallest decrease is for ambient conditions where the largest decrease is for exposure to 80 percent relative humidity. Similar behavior was observed for panels protected using polymer films, except the decrease in thermal conductivity was significantly higher, between approximately 20 and 60 percent, in the same order as for panels protected by metalized films. Measurements are ongoing with an attempt to develop a better relationship between these types of tests and vacuum insulation panel service life.

Aldykiewicz Jr, Antonio↗

Effect of Drying on Corrosion Mitigation of Hanford Transfer Lines

Radioactive waste is stored in underground, carbon-steel double-shell tanks at the Department of Energy Hanford site. The waste is transferred between the tanks and other assets using the transfer lines spanning throughout the various tank farms at Hanford. The transfer lines consist of a pipe-in-pipe design, small diameter pipes, and are not piggable. Recent inspection data of the transfer lines have shown areas with corrosion on both interior of the encasements and exterior of the primary pipes, with nearly 50 percent wall loss on the primary pipes and nearly 25% wall loss on the encasement pipes due to pitting corrosion. The visual inspections of the transfer lines have shown presence of corrosion products near the pipeline risers and beyond. It has been hypothesized that the corrosion is predominantly due to the high humidity conditions and in some cases is driven by the presence of residual hydrotest water in the encasement and the associated contact with the safety significant primary pipe. Therefore, drying of the transfer lines could lead to corrosion mitigation. Experimental studies are being conducted to understand the effect of environmental conditions, especially, relative humidity and temperature, on transfer line grade carbon steel corrosion and on mitigating corrosion. The experimental conditions are selected based on the seasonal temperature changes, and relative humidity conditions ranging from 30 to 100 percent. The experimental data will be used as guidance for maintaining a dry environment that will help mitigate the transfer-line corrosion caused by the high humidity conditions.

Shukla, Pavan K.↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗