Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid solutions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Elliptic Volume Grid Generation for Viscous CFD Parametric Design Studies

This paper presents a robust method for the generation of zonal volume grids of design parametrics for aerodynamic configurations. The process utilizes simple algebraic techniques with parametric splines coupled with elliptic volume grid generation to generate isolated zonal grids for changes in body configuration needed to perform parametric design studies. Speed of the algorithm is maximized through the algebraic methods and reduced number of grid points to be regenerated for each design parametric without sacrificing grid quality and continuity within the volume domain. The method is directly applicable to grid reusability, because it modifies existing ow adapted volume grids and enables the user to restart the CFD solution process with an established flow field. Use of this zonal approach reduces computer usage time to create new volume grids for design parametric studies by an order of magnitude, as compared to current methods which require the regeneration of an entire volume grid. A sample configuration of a proposed Single Stage-to-Orbit Vehicle is used to illustrate an application of this method.

Alter, Stephen J.↗

Numerical methods in laminar and turbulent flow; Proceedings of the 7th International Conference, Stanford Univ., CA, July 15-19, 1991. Vol. 7, pts. 1 & 2

Consideration is given to the impulse response of a laminar boundary layer and receptivity; numerical transition to turbulence in plane Poiseuille flow; large eddy simulation of turbulent wake flow; a viscous model and loss calculation of a multisplitter cascade; vortex initiation during dynamic stall of an airfoil; a numerical analysis of isothermal flow in a combustion chamber; and compressible flow calculations with a two-equation turbulence model and unstructured grids. Attention is also given to a 2D calculation of a buoyant flow around a burning sphere, a fast multigrid method for 3D turbulent incompressible flows, a streaming flow induced by an oscillating cascade of circular cylinders, an algebraic multigrid scheme for solving the Navier-Stokes equations on unstructured meshes; and nonlinear coupled multigrid solutions to thermal problems employing different nodal grid arrangements and convective transport approximations.

Taylor, C.↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

Investigation of advanced counterrotation blade configuration concepts for high speed turboprop systems. Task 4: Advanced fan section aerodynamic analysis computer program user's manual

The computer program user's manual for the ADPACAPES (Advanced Ducted Propfan Analysis Code-Average Passage Engine Simulation) program is included. The objective of the computer program is development of a three-dimensional Euler/Navier-Stokes flow analysis for fan section/engine geometries containing multiple blade rows and multiple spanwise flow splitters. An existing procedure developed by Dr. J. J. Adamczyk and associates at the NASA Lewis Research Center was modified to accept multiple spanwise splitter geometries and simulate engine core conditions. The numerical solution is based upon a finite volume technique with a four stage Runge-Kutta time marching procedure. Multiple blade row solutions are based upon the average-passage system of equations. The numerical solutions are performed on an H-type grid system, with meshes meeting the requirement of maintaining a common axisymmetric mesh for each blade row grid. The analysis was run on several geometry configurations ranging from one to five blade rows and from one to four radial flow splitters. The efficiency of the solution procedure was shown to be the same as the original analysis.

Crook, Andrew J.↗

Computational analysis of forebody tangential slot blowing on the high alpha research vehicle

A numerical analysis of forebody tangential slot blowing as a means of generating side force and yawing moment is conducted using an aircraft geometry. The Reynolds-averaged, thin-layer, Navier-Stokes equations are solved using a partially flux-split, approximately-factored algorithm. An algebraic turbulence model is used to determine the turbulent eddy viscosity values. Solutions are obtained using both patched and overset grid systems. In the patched grid model, and actuator plane is used to introduce jet variables into the flow field. The overset grid model is used to model the physical slot geometry and facilitate modeling of the full aircraft configuration. A slot optimization study indicates that a short slot located close to the nose of the aircraft provided the most side force and yawing moment per unit blowing coefficient. Comparison of computed surface pressure with that obtained in full-scale wind tunnel tests produce good agreement, indicating the numerical method and grid system used in the study are valid. Full aircraft computations resolve the changes in vortex burst point due to blowing. A time-accurate full-aircraft solution shows the effect of blowing on the changes in the frequency of the aerodynamic loads over the vertical tails. A study of the effects of freestream Mach number and various jet parameters indicates blowing remains effective through the transonic Mach range. An investigation of the force onset time lag associated with forebody blowing shows the lag to be minimal. The knowledge obtained in this study may be applied to the design of a forebody tangential slot blowing system for use on flight aircraft.

Gee, Ken↗

Displaying CFD Solution Parameters on Arbitrary Cut Planes

USMC6 is a Fortran 90 computer program for post-processing in support of visualization of flows simulated by computational fluid dynamics (CFD). The name "USMC6" is partly an abbreviation of "TetrUSS - USM3D Solution Cutter," reflecting its origin as a post-processor for use with USM3D - a CFD program that is a component of the Tetrahedral Unstructured Software System and that solves the Navier-Stokes equations on tetrahedral unstructured grids. "Cutter" here refers to a capability to acquire and process solution data on (1) arbitrary planes that cut through grid volumes, or (2) user-selected spheroidal, conical, cylindrical, and/or prismatic domains cut from within grids. Cutting saves time by enabling concentration of post-processing and visualization efforts on smaller solution domains of interest. The user can select from among more than 40 flow functions. The cut planes can be trimmed to circular or rectangular shape. The user specifies cuts and functions in a free-format input file using simple and easy-to-remember keywords. The USMC6 command line is simple enough that the slicing process can readily be embedded in a shell script for assembly-line post-processing. The output of USMC6 is a data file ready for plotting.

Pao, S. Paul↗

Multiple-gridding of the Euler equations with an implicit scheme

The multiple-grid scheme of Ni (1981) for the solution of the unsteady Euler equations for quasi-one-dimensional transonic flow problems is analyzed according to its ability to accelerate convergence to a steady state solution, its applicability to an implicit scheme, its accuracy, and its stability limits. This scheme is applied successfully to McCormack's (1981) implicit method of solving quasi-one-dimensional transonic flow problems for CFL numbers significantly greater than unity. It is determined that the second order accuracy of this implicit method is preserved by employing the multiple gridding. However, stability limitations that are flow dependent are introduced into the implicit method by the use of the multiple-grid scheme which will curtail its use under certain flow conditions. A scaling modification for the multiple grid scheme is developed which further improves its performance when used with explicit and artificially-damped implicit methods without any increase in computational work.

Stubbs, R. M.↗

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

Data-Driven Modeling of High-Resolution Residential Load Profiles Using Low-Resolution Smart Meter Measurements

Accurate and high-resolution residential load profiles are essential for power system modeling, demand response planning, and effective grid operation. As the energy sector moves towards a more actively managed distribution system, the ability to understand residential energy consumption at a minute-by-minute scale becomes increasingly critical. High-resolution load profiles provide key insights into demand patterns and user behavior, enabling grid operators to design more effective energy solutions; however, residential load measurements in the field are typically recorded at low resolutions, such as 15-60 minutes, which makes it hard to study the characteristics of different residential customers. This paper addresses these challenges by introducing a data-driven approach to generate realistic, high-resolution residential load profiles based on lowre-solution measurements and weather information. The proposed method retains the key features of the actual residential load measurements while offering appliance-level energy consumption details for each residential building. The results demonstrate the effectiveness of the proposed load profile generator, proving its capability to support utilities in optimizing residential energy management and ensuring a more reliable and resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability and convergence of nuclear detonations in white dwarf collisions

We investigate the numerical stability of thermonuclear detonations in 1D accelerated reactive shocks and 2D binary collisions of equal-mass magnetized and unmagnetized white dwarf stars. To achieve high resolution at initiation sites, we devised geometric gridding and mesh velocity strategies specially adapted to the unique requirements of head-on collisional geometries, scenarios in which one expects maximum production of iron-group products. We study the effects of grid resolution and the limiting of temperature, energy, and reactants for different stellar masses, separations, magnetic fields, inigenerationtial compositions, detonation mechanisms, and limiter parameters across a range of cell sizes from 1 to 100 km. Our results set bounds on the parameter space of limiter amplitudes for which both temperature- and energy-limiting procedures yield consistent and monotonically convergent solutions. Within these bounds, we find that grid resolutions of 5 km or better are necessary for uncertainties in total released energy and iron-group products to drop below 10%. Intermediate-mass products (e.g., calcium) exhibit similar convergence trends but with somewhat greater uncertainty. These conclusions apply equally to pure C/O white dwarfs, multispecies compositions (including helium shells), magnetized and unmagnetized cores, and either single or multiple detonation scenarios.

79 ASTRONOMY AND ASTROPHYSICS↗

Do We Really Need Storage to Operate the Renewable Grid of the Future?

While it may seem obvious that wind and solar 'need' energy storage to be successfully integrated into the world's electricity grids, both detailed integration studies and real-world experience have shown that storage is only one of many options that could enable substantially increased growth of these renewable resources. This talk will discuss the potential role of energy storage in the integrating wind and solar, demonstrating that in the near term perhaps less exciting -- but often more cost-effective -- alternatives will likely provide much of the grid flexibility needed to add renewable resources. The talk will also demonstrate that the decreasing value of PV and wind and at increased penetration creates greater opportunities for storage. It also demonstrates the fact that 'the sun doesn't always shine and the wind always doesn't blow' is only one reason why energy storage may be an increasingly attractive solution to the challenges of operating the grid of the future.

25 ENERGY STORAGE↗

Attack-resilient algorithms and testbed federation for wide-area protection and control in smart grid

Today’s energy infrastructure is undergoing a massive transformation across all generation, transmission, and distribution systems to provide reliability, efficiency, and sustainability to the power system network. During the past 10 years, there has been a remarkable enhancement in developing close-loop wide-area protection and control (WAPAC) applications, such as automatic generation control (AGC), wide-area protection scheme (WAPS), synchrophasor-based wide-area voltage control system (WAVCS), etc., in the energy management system (EMS) to provide an adequate situational awareness to control center operators during physical disturbances and natural events. The rapid digitalization, unencrypted communication, and numerous data-sharing devices have increased digital access points that have exposed the grid network to countless cyberattacks pertinent to the WAPAC cybersecurity. Given the amount of complex grid network coupled with legacy infrastructures, it is untrustworthy to completely rely on information technology (IT)-based conventional security measures to defend against evolving cyberattacks. Hence, there is a compelling need to go beyond the traditional paradigm of ‘security by obscurity’ and ‘bolt-on’ security measures, and develop a suite of innovative security solutions at multiple layers to transform the current “fault-resilient” grid into “fault and attack-resilient” grid of the future. This dissertation specifically focuses on developing application-specific attack-resilient solutions for critical WAPAC applications in the smart grid. The first part of the study, Attack-Resilient Wide-Area Protection Scheme, presents a cyber-physical attack-resilient system (CPARS) for WAPS, where two anomaly detection methods are proposed to detect multi-level cyberattacks followed by the rules-based intrusion mitigation system (RIMS) to initiate effective mitigation strategies, tailored to these attacks, to restore the normal grid operation after disturbances. The first anomaly detection component, Machine learning-based Anomaly Detection for Centralized WAPS, discusses a novel architecture and methodology for developing a machine-learning-based anomaly detection system (ADS) for the centralized wide-area protection system (CWAPS) by applying the variational mode decomposition (VMD) technique and decision tree (DT) algorithms using cyber logs and synchrophasor measurements. The second component, Multi-Agent-based Anomaly Detection for Decentralized WAPS, presents a two-level hierarchical multi-agent-based decentralized WAPS against the system-aware stealthy cyber-attacks. Finally, for the RIMS, the state transition diagram-based mitigation measures are defined based on the grid operation states and experimental testing and evaluation are presented in a cyber-physical testbed environment. The second part of the study, Attack-Resilient Wide-Area Voltage Control System, addresses the existing vulnerabilities in the wide-area voltage control system (WAVCS), presents the methodology for performing an impact analysis during data integrity attacks, and proposes a data-driven attackresilient system (DARS) by incorporating machine learning-based ADS and rules-based anomaly mitigation system (RAMS) to detect these attacks and provide necessary mitigation actions to maintain the transient voltage stability after disturbances. Finally, the third part, Networked Federation Testbed (NEFTSec) for Smart Grid Cybersecurity, focuses on developing an interconnected federated testbed through a common network like the internet, describes its conceptual architectures, and also presents its design components for experimental testing, validation, and evaluation. Further, it presents the co-simulation interface algorithm (CIA) to facilitate the geographically-dispersed real-time distributed simulation (GD-RTDS) during the cyber-physical federation. In general, this dissertation presents innovative attack-resilient solutions for WAPAC applications that are experimentally tested and evaluated using the PowerCyber testbed and NEFTSec platform to accelerate the transition of state-of-the-art research works to the real-field deployments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A combined integrating and differentiating matrix formulation for boundary value problems on rectangular domains

Integrating and differentiating matrices allow the numerical integration and differential of functions whose values are known at points of a discrete grid. Previous derivations of these matrices were restricted to one dimensional grids or to rectangular grids with uniform spacing in at least one direction. Integrating and differentiating matrices were developed for grids with nonuniform spacing in both directions. The use of these matrices as operators to reformulate boundary value problems on rectangular domains as matrix problems for a finite dimensional solution vector is considered. The method requires nonuniform grids which include near boundary points. An eigenvalue problem for the transverse vibrations of a simply supported rectangular plate is solved to illustrate the method.

Lakin, W. D.↗

A combined integrating- and differentiating-matrix formulation for boundary-value problems on rectangular domains

Integrating and differentiating matrices allow the numerical integration and differential of functions whose values are known at points of a discrete grid. Previous derivations of these matrices were restricted to one dimensional grids or to rectangular grids with uniform spacing in at least one direction. Integrating and differentiating matrices were developed for grids with nonuniform spacing in both directions. The use of these matrices as operators to reformulate boundary value problems on rectangular domains as matrix problems for a finite dimensional solution vector is considered. The method requires nonuniform grids which include near boundary points. An eigenvalue problem for the transverse vibrations of a simply supported rectangular plate is solved to illustrate the method.

Lakin, W. D.↗

Automatic Boundary-Layer Adaptation of Structured Grids in VULCAN-CFD

In supersonic and hypersonic flow computations, well-resolved boundary layers are essential for accurate quantification of surface heating and transition prediction, particularly via linear stability analysis. Grid design for hypersonic flows with shocks, boundary-layer separation, and/or complex mean flow features incorporating spanwise/azimuthal inhomogeneities is a difficult issue. In comparison to a manual grid adaptation procedure, an autonomous grid adaptation technique offers significant improvements in computing time and solution quality. The VULCAN-CFD solver already includes a validated procedure for automatic adaption of structured grids to the bow shock. The present focus is on implementing an automatic boundary-layer adaptation capability in VULCAN-CFD that adapts structured, multiblock grids to both the bow shock and the boundary layer at the same time. The boundary-layer adaptation algorithm allows the user to specify the number of cells within the boundary layer, along with the input parameters used for detecting the edge of the boundary layer, namely, the variable used in the edge detection criterion,the edge detection method, the detection direction, and the relaxation factor used during the morphing of the grid. The algorithm automatically distributes grid points along the wall-normal direction to achieve a smooth variation in grid spacing from the edge of the boundary layer to a"junction" location within the outer part of the grid. Illustrative results are presented for three different high-speed configurations: the two-dimensional flow over a cylinder at Mach 17.6 and unit Reynolds number of Re=0.38x10^6 m^-1, the axisymmetric flow over a cone-cylinder-flare model at Mach 6.0 and Re = 10.5×10^6 m^-1, and the three-dimensional flow over a blunt, 7-degree half-angle cone at 5-degree angle of attack in a Mach 9.79 flow with Re = 17.1×10^6 m^-1. The automated boundary-layer adaptation is shown to provide an adequate grid topology that is aligned with the bow shock in the outer part of the grid and also resolves the viscous boundary-layer region close to the surface.

boundary layer transition↗

KMT-2021-BLG-1150Lb: Microlensing Planet Detected Through a Densely Covered Planetary-Caustic Signal

Aims. Recently, there have been reports of various types of degeneracies in the interpretation of planetary signals induced by planetary caustics. In this work we check whether such degeneracies persist in the case of well-covered signals by analyzing the lensing event KMT-2021-BLG-1150, the light curve of which exhibits a densely and continuously covered short-term anomaly. Methods. In order to identify degenerate solutions, we thoroughly investigated the parameter space by conducting dense grid searches for the lensing parameters. We then checked the severity of the degeneracy among the identified solutions. Results. We identify a pair of planetary solutions resulting from the well-known inner-outer degeneracy, and find that interpreting the anomaly is not subject to any degeneracy other than the inner-outer degeneracy. The measured parameters of the planet separation (normalized to the Einstein radius) and mass ratio between the lens components are ( s , q ) in ∼ (1.297, 1.10 × 10 −3 ) for the inner solution and ( s , q ) out ∼ (1.242, 1.15 × 10 −3 ) for the outer solution. According to a Bayesian estimation, the lens is a planetary system consisting of a planet with a mass M p = 0.88 +0.38 −0.36 M J and its host with a mass M h = 0.73 +0.32 −0.30 M ⊙ lying toward the Galactic center at a distance D L = 3.8 +1.3 −1.2 kpc. By conducting analyses using mock data sets prepared to mimic those obtained with data gaps and under various observational cadences, we find that gaps in data can result in various degenerate solutions, while the observational cadence does not pose a serious degeneracy problem as long as the anomaly feature can be delineated.

Gravitational microlensing↗

Euler solutions using an implicit multigrid technique

A coarse-grid correction algorithm has been implemented into an implicit upwind Euler solver and tested for transonic airfoil problems. The Euler solver uses split-flux formulation and penta-diagonal scalar equations, respectively, for the explicit and implicit operators. The multigrid sequence starts at the fine grid level, then steps down to each coarse grid level to smooth error components using implicit operators. Estimate of residuals can be obtained by two approaches, which differ in the level where the residuals are collected. Both approaches will lead to a work reduction factor of 12 for a Mach 0.75 flow at 2 degrees incidence on a 65x26 grid. The work reduction factor is found to increase proportional to the number of grid levels.

Li, Chien-Peng↗

A multiblock, multigrid solution procedure for multielement airfoils

A block-structured grid formulation is presented and discussed. The compressible Euler equations are solved on the decomposed domain with a multigrid method based on Runge-Kutta time stepping and centered spatial differencing. The flexibility of the multiblock approach is demonstrated by computing low speed inviscid flow over two different multielement airfoil configurations.

Sanetrik, Mark D.↗