Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow enhancer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Supercritical CO2 Cleaning System for Planetary Protection and Contamination Control Applications

Current spacecraft-compatible cleaning protocols involve a vapor degreaser, liquid sonication, and alcohol wiping. These methods are not very effective in removing live and dead microbes from spacecraft piece parts of slightly complicated geometry, such as tubing and loosely fitted nuts and bolts. Contamination control practices are traditionally focused on cleaning and monitoring of particulate and oily residual. Vapor degreaser and outgassing bakeout have not been proven to be effective in removing some less volatile, hydrophilic biomolecules of significant relevance to life detection. A precision cleaning technology was developed using supercritical CO2 (SCC). SCC is used as both solvent and carrier for removing organic and particulate contaminants. Supercritical fluid, like SCC, is characterized by physical and thermal properties that are between those of the pure liquid and gas phases. The fluid density is a function of the temperature and pressure. Its solvating power can be adjusted by changing the pressure or temperature, or adding a secondary solvent such as alcohol or water. Unlike a regular organic solvent, SCC has higher diffusivities, lower viscosity, and lower surface tension. It readily penetrates porous and fibrous solids and can reach hard-to-reach surfaces of the parts with complex geometry. Importantly, the CO2 solvent does not leave any residue. The results using this new cleaning device demonstrated that both supercritical CO2 with 5% water as a co-solvent can achieve cleanliness levels of 0.01 mg/cm2 or less for contaminants of a wide range of hydrophobicities. Experiments under the same conditions using compressed Martian air mix, which consists of 95% CO2, produced similar cleaning effectiveness on the hydrophobic compounds. The main components of the SCC cleaning system are a high-pressure cleaning vessel, a boil-off vessel located downstream from the cleaning vessel, a syringe-type high-pressure pump, a heat exchanger, and a back pressure regulator (BPR). After soaking the parts to be cleaned in the clean vessel for a period, the CO2 with contaminants is flushed out of the cleaning vessel using fresh CO2 in a first-in-first-out (FIFO) method. The contaminants are either precipitating out in the boil-off container or being trapped in a filter subsystem. The parts to be cleaned are secured in a basket inside and can be rotated up to 1,400 rpm by a magnetic drive. The fluid flows within the vessel generate tangential forces on the parts surfaces, enhancing the cleaning effectiveness and shortening the soaking time. During the FIFO flushing, the pump subsystem pushes fresh CO2 into the cleaning vessel at a constant flow rate between 0.01 and 200 mL/min, while the BPR regulates the pressure in the cleaning vessel to within 0.1 bar by controlling the needle position in an outlet valve. The fresh CO2 gas flows through the heat exchanger at a given temperature before entering the cleaning vessel. A platinum resistance thermometer (PRT) reads the cleaning vessel interior temperature that can be controlled to within 0.1 K. As a result, cleaning vessel temperature remains constant during the FIFO flushing. There is no change in solvent power during FIFO flushing since both temperature and pressure inside the cleaning vessel remain unchanged, thus minimizing contaminants left behind. During decompression, both temperature and pressure are strictly controlled to prevent bubbles from generating in the cleaning vessel that could stir up the contaminants that sank to the bottom by gravity.

Lin, Ying↗

TOUGHREACT User's Guide: A Simulation Program for Non-isothermal Multiphase Reactive Geochemical Transport in Variably Saturated Geologic Media, V1.2.1

Coupled modeling of subsurface multiphase fluid and heat flow, solute transport, and chemical reactions can be applied to many geologic systems and environmental problems, including geothermal systems, diagenetic and weathering processes, subsurface waste disposal, acid mine drainage remediation, contaminant transport, and groundwater quality. TOUGHREACT has been developed as a comprehensive non-isothermal multi-component reactive fluid flow and geochemical transport simulator to investigate these and other problems. A number of subsurface thermo-physical-chemical processes are considered under various thermohydrological and geochemical conditions of pressure, temperature, water saturation, and ionic strength. TOUGHREACT can be applied to one-, two- or three-dimensional porous and fractured media with physical and chemical heterogeneity. The code can accommodate any number of chemical species present in liquid, gas and solid phases. A variety of equilibrium chemical reactions are considered, such as aqueous complexation, gas dissolution/exsolution, and cation exchange. Mineral dissolution/precipitation can take place subject to either local equilibrium or kinetic controls, with coupling to changes in porosity and permeability and capillary pressure in unsaturated systems. Chemical components can also be treated by linear adsorption and radioactive decay. The first version of the non-isothermal reactive geochemical transport code TOUGHREACT was developed (Xu and Pruess, 1998) by introducing reactive geochemistry into the framework of the existing multi-phase fluid and heat flow code TOUGH2 (Pruess, 1991). TOUGHREACT was further enhanced with the addition of (1) treatment of mineral-water-gas reactive-transport under boiling conditions, (2) an improved HKF activity model for aqueous species, (3) gas species diffusion coefficients calculated as a function of pressure, temperature, and molecular properties, (4) mineral reactive surface area formulations for fractured and porous media, and (5) porosity, permeability, and capillary pressure changes owing to mineral precipitation/dissolution (Sonnenthal et al., 1998, 2000, 2001; Spycher et al., 2003a). Subsequently, TOUGH2 V2 was released with additional EOS modules and features (Pruess et al., 1999). The present version of TOUGHREACT includes all of the previous extensions to the original version, along with the replacement of the original TOUGH2 (Pruess, 1991) by TOUGH2 V2 (Pruess et al., 1999). TOUGHREACT has been applied to a wide variety of problems, some of which are included as examples, such as: (1) Supergene copper enrichment (Xu et al., 2001); (2) Mineral alteration in hydrothermal systems (Xu and Pruess, 2001a; Xu et al., 2004b; Dobson et al., 2004); (3) Mineral trapping for CO{sub 2} disposal in deep saline aquifers (Xu et al., 2003b and 2004a); (4) Coupled thermal, hydrological, and chemical processes in boiling unsaturated tuff for the proposed nuclear waste emplacement site at Yucca Mountain, Nevada (Sonnenthal et al., 1998, 2001; Sonnenthal and Spycher, 2000; Spycher et al., 2003a, b; Xu et al., 2001); (5) Modeling of mineral precipitation/dissolution in plug-flow and fracture-flow experiments under boiling conditions (Dobson et al., 2003); (6) Calcite precipitation in the vadose zone as a function of net infiltration (Xu et al., 2003); and (7) Stable isotope fractionation in unsaturated zone pore water and vapor (Singleton et al., 2004). The TOUGHREACT program makes use of 'self-documenting' features. It is distributed with a number of input data files for sample problems. Besides providing benchmarks for proper code installation, these can serve as a self-teaching tutorial in the use of TOUGHREACT, and they provide templates to help jump-start new applications. The fluid and heat flow part of TOUGHREACT is derived from TOUGH2 V2, so in addition to the current manual, users must have the manual of the TOUGH2 V2 (Pruess et al., 1999). The present version of TOUGHREACT provides the following TOUGH2 fluid property or 'EOS' (equation-of-state) modules: (1) EOS1 for water, or two waters with typical applications to hydrothermal problems, (2) EOS2 for multiphase mixtures of water and CO{sub 2} also with typical applications to hydrothermal problems, (3) EOS3 for multiphase mixtures of water and air with typical applications to vadose zone and nuclear waste disposal problems, (4) EOS4 that has the same capabilities as EOS3 but with vapor pressure lowering effects due to capillary pressure, (5) EOS9 for single phase water (Richards equation) with typical applications to ambient temperature and pressure reactive geochemical transport problems, and (6) ECO2N for multiphase mixtures of water, CO{sub 2} and NaCl with typical applications to CO{sub 2} disposal in deep brine aquifers.

54 ENVIRONMENTAL SCIENCES↗

Medical Image Analysis Facility

To improve the quality of photos sent to Earth by unmanned spacecraft. NASA's Jet Propulsion Laboratory (JPL) developed a computerized image enhancement process that brings out detail not visible in the basic photo. JPL is now applying this technology to biomedical research in its Medical lrnage Analysis Facility, which employs computer enhancement techniques to analyze x-ray films of internal organs, such as the heart and lung. A major objective is study of the effects of I stress on persons with heart disease. In animal tests, computerized image processing is being used to study coronary artery lesions and the degree to which they reduce arterial blood flow when stress is applied. The photos illustrate the enhancement process. The upper picture is an x-ray photo in which the artery (dotted line) is barely discernible; in the post-enhancement photo at right, the whole artery and the lesions along its wall are clearly visible. The Medical lrnage Analysis Facility offers a faster means of studying the effects of complex coronary lesions in humans, and the research now being conducted on animals is expected to have important application to diagnosis and treatment of human coronary disease. Other uses of the facility's image processing capability include analysis of muscle biopsy and pap smear specimens, and study of the microscopic structure of fibroprotein in the human lung. Working with JPL on experiments are NASA's Ames Research Center, the University of Southern California School of Medicine, and Rancho Los Amigos Hospital, Downey, California.

Source record↗

Advances in imaging instrumentation for nuclear cardiology

Advances in imaging instrumentation and technology have greatly contributed to nuclear cardiology. Dedicated cardiac SPECT cameras incorporating novel, highly efficient detector, collimator, and system designs have emerged with the expansion of nuclear cardiology. Solid-state radiation detectors incorporating cadmium zinc telluride, which directly convert radiation to electrical signals and yield improved energy resolution and spatial resolution and enhanced count sensitivity geometries, are increasingly gaining favor as the detector of choice for application in dedicated cardiac SPECT systems. Additionally, hybrid imaging systems in which SPECT and PET are combined with X-ray CT are currently widely used, with PET/MRI hybrid systems having also been recently introduced. The improved quantitative SPECT/CT has the potential to measure the absolute quantification of myocardial blood flow and flow reserve. Rapid development of silicon photomultipliers leads to enhancement in PET image quality and count rates. In addition, the reduction of emission–transmission mismatch artifacts via application of accurate time-of-flight information, and cardiac motion de-blurring aided by anatomical images, are emerging techniques for further improvement of cardiac PET. This article reviews recent advances such as these in nuclear cardiology imaging instrumentation and technology, and the corresponding diagnostic benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Gas Flow Rate for Formation of Aligned Nanorods in ZnO Thin Films for Solar-Driven Hydrogen Production

ZnO thin films have been deposited in mixed Ar/N{sub 2} gas ambient at substrate temperature of 500 C by radiofrequency sputtering of ZnO targets. We find that an optimum N{sub 2}-to-Ar ratio in the deposition ambient promotes the formation of well-aligned nanorods. ZnO thin films grown in ambient with 25% N{sub 2} gas flow rate promoted nanorods aligned along c-axis and exhibit significantly enhanced photoelectrochemical (PEC) response, compared with ZnO thin films grown in an ambient with different N{sub 2}-to-Ar gas flow ratios. Our results suggest that chamber ambient is critical for the formation of aligned nanostructures, which offer potential advantages for improving the efficiency of PEC water splitting for H{sub 2} production.

14 SOLAR ENERGY↗

Higher Ion Selectivity with Lower Energy Usage Promoted by Electro-osmotic Flow in the Transport through Conical Nanopores

The tradeoff between selectivity and throughput presents fundamental challenges to improve desalination and charge storage, salinity gradient-based energy harvesting, memory device/circuit development, and so forth. The well-known ion-current rectification and the recently resolved time-dependent transport hysteresis in conical nanopores or asymmetric nanointerfaces offer new opportunities for the selective transport of matter. This report shows that electro-osmotic flow (EOF) is an overlooked factor that increases ion selectivity while maintaining enhanced transport throughput in rectified nanoscale electrokinetic transport. The increased selectivity originates primarily from the suppression of anion flux by the fluid flow in the opposite direction under the applied electrical field. By solving the Poisson and Nernst–Planck (PNP) equations without and with coupled Navier–Stokes (PNP–NS) equations, the EOF effects on cation and anion transport are unequivocally revealed in asymmetric nanopipettes. The flux of cations and anions as well as the transference number and flow velocity are elucidated using the models and boundary conditions validated by previous experiments. A dimensionless parameter, radius over the Debye length, reveals optimal ion selectivity and energy cost at intermediate ion concentrations and nanopore sizes, up to hundreds of millimolars and tens of nanometers under time-dependent potential stimulus. Furthermore, the fundamental insights into EOF at nanointerfaces suggest new routes/strategies for better separation, analysis, and energy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of Interfacial Area Production and Permeability within Porous Media

An understanding of the pore-level interactions that affect multi-phase flow in porous media is important in many subsurface engineering applications, including enhanced oil recovery, remediation of dense non-aqueous liquid contaminated sites, and geologic CO2 sequestration. Standard models of two-phase flow in porous media have been shown to have several shortcomings, which might partially be overcome using a recently developed model based on thermodynamic principles that includes interfacial area as an additional parameter. A few static experimental studies have been previously performed, which allowed the determination of static parameters of the model, but no information exists concerning the interfacial area dynamic parameters. A new experimental porous flow cell that was constructed using stereolithography for two-phase gas-liquid flow studies was used in conjunction with an in-house analysis code to provide information on dynamic evolution of both fluid phases and gas-liquid interfaces. In this paper, we give a brief introduction to the new generalized model of two-phase flow model and describe how the stereolithography flow cell experimental setup was used to obtain the dynamic parameters for the interfacial area numerical model. In particular, the methods used to determine the interfacial area permeability and production terms are shown.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Issues and approach to develop validated analysis tools for hypersonic flows: One perspective

Critical issues concerning the modeling of low-density hypervelocity flows where thermochemical nonequilibrium effects are pronounced are discussed. Emphasis is on the development of validated analysis tools. A description of the activity in the Ames Research Center's Aerothermodynamics Branch is also given. Inherent in the process is a strong synergism between ground test and real-gas computational fluid dynamics (CFD). Approaches to develop and/or enhance phenomenological models and incorporate them into computational flow-field simulation codes are discussed. These models have been partially validated with experimental data for flows where the gas temperature is raised (compressive flows). Expanding flows, where temperatures drop, however, exhibit somewhat different behavior. Experimental data for these expanding flow conditions are sparse; reliance must be made on intuition and guidance from computational chemistry to model transport processes under these conditions. Ground-based experimental studies used to provide necessary data for model development and validation are described. Included are the performance characteristics of high-enthalpy flow facilities, such as shock tubes and ballistic ranges.

Deiwert, George S.↗

Density fluctuations in solar wind flow types at 1 AU: Comparison to Doppler scintillation measurements

Density fluctuations with periods 10 minutes to 1 hour have been investigated in ISEE 3 plasma measurements of solar wind flows at l AU. Coronal hole, interstream, plasma sheet, coronal mass ejection, and interaction region flow types are considered. The ISEE 3 results support the interpretation of the large-scale variations in density fluctuations observed by Doppler scintillation measurement techniques inside 0.2 AU. The highest absolute and relative density fluctuations occur ahead of and within the plasma from coronal mass ejections, with the maximum values occurring between the associated interplanetary shocks and the driver gas. For the quasi-stationary solar wind, density and relative density fluctuations are highest around the heliospheric current sheet and lowest in the high-speed coronal flow. Superposed epoch analysis shows that the region of enhanced density fluctuations and its abrupt boundaries observed in the vicinity of the heliospheric current sheet near the Sun persists to l AU, providing further support for the filamentary nature of the extensions of coronal streamers. The results of this study confirm the advantages of using density fluctuations rather than density as a tracer of solar wind flows with differing origins at the Sun and as a detector of propagating interplanetary disturbances.

Huddleston, D. E.↗

Corrosion in Supercritical Carbon Dioxide: Materials, Environmental Purity, Surface Treatments, and Flow Issues (Project No. 10-872)

The supercritical CO 2 Brayton cycle is gaining importance for power conversion in the Generation IV fast reactor system because of its high conversion efficiencies. When used in conjunction with a sodium fast reactor, the supercritical CO 2 cycle offers additional safety advantages by eliminating potential sodium-water interactions that may occur in a steam cycle. In power conversion systems for Generation IV fast reactors, supercritical CO 2 temperatures could be in the range of 30°C to 650°C, depending on the specific component in the system. Materials corrosion primarily at high temperatures will be an important issue. Therefore, the corrosion performance limits for materials at various temperatures must be established. The proposed research will have four objectives centered on addressing corrosion issues in a high-temperature supercritical CO 2 environment: Task 1: Evaluation of corrosion performance of candidate alloys in high-purity supercritical CO 2 : The following alloys will be tested: Ferritic-martensitic Steels NF616 and HCM12A, austenitic alloys Incoloy 800H and 347 stainless steel, and two advanced concept alloys, AFA (alumina forming austenitic) steel and MA754. Supercritical CO 2 testing will be performed at 450°C, 550°C, and 650°C at a pressure of 20 MPa, in a test facility that is already in place at the proposing university. High purity CO 2 (99.9998%) will be used for these tests. Task 2: Investigation of the effects of CO, H 2 O, and O 2 impurities in supercritical CO 2 on corrosion: Impurities that will inevitably present in the CO 2 will play a critical role in dictating the extent of corrosion and corrosion mechanisms. These effects must be understood to identify the level of CO 2 chemistry control needed to maintain sufficient levels of purity to manage corrosion. The individual effects of important impurities CO, H 2 O, and O 2 will be investigated by adding them separately to high purity CO 2 . Task 3: Evaluation of surface treatments on the corrosion performance of alloys in supercritical CO 2 : Surface treatments can be very beneficial in improving corrosion resistance. Shot peening and yttrium and aluminum surface treatments will be investigated. Shot peening refines the surface grain sizes and promotes protective Cr-oxide layer formation. Both yttrium and aluminum form highly stable oxide layers (Y 2 O 3 and Al 2 O 3 ), which can get incorporated in the growing Fe-oxide layer to form an impervious complex oxide to enhance corrosion resistance. Task 4: Study of flow-assisted corrosion of select alloys in supercritical CO 2 under a selected set of test conditions: To study the effects of flow-assisted corrosion, tests will be conducted in a supercritical CO 2 flow loop. An existing facility used for supercritical water flow studies at the proposing university will be modified for use in this task. The system is capable of flow velocities up to 10 m/s and can operate at temperatures and pressures of up to 650°C and 20 MPa, respectively. All above tasks will be performed in conjunction with detailed materials characterization and analysis using scanning electron microscopy/energy dispersive spectroscopy (SEM-EDS), x-ray diffraction (XRD), Auger electron spectroscopy (AES) techniques, and weight change measurements. Inlet and outlet gas compositions will be monitored using gas chromatography-mass spectrometry (GCMS).

36 MATERIALS SCIENCE↗

Ion Exclusion by Sub 2-nm Carbon Nanotube Pores

Carbon nanotubes offer an outstanding platform for studying molecular transport at nanoscale, and have become promising materials for nanofluidics and membrane technology due to their unique combination of physical, chemical, mechanical, and electronic properties. In particular, both simulations and experiments have proved that fluid flow through carbon nanotubes of nanometer size diameter is exceptionally fast compared to what continuum hydrodynamic theories would predict when applied on this length scale, and also, compared to conventional membranes with pores of similar size, such as zeolites. For a variety of applications such as separation technology, molecular sensing, drug delivery, and biomimetics, selectivity is required together with fast flow. In particular, for water desalination, coupling the enhancement of the water flux with selective ion transport could drastically reduce the cost of brackish and seawater desalting. In this work, we study the ion selectivity of membranes made of aligned double-walled carbon nanotubes with sub-2 nm diameter. Negatively charged groups are introduced at the opening of the carbon nanotubes by oxygen plasma treatment. Reverse osmosis experiments coupled with capillary electrophoresis analysis of permeate and feed show significant anion and cation rejection. Ion exclusion declines by increasing ionic strength (concentration) of the feed and by lowering solution pH; also, the highest rejection is observed for the A{sub m}{sup Z{sub A}} C{sub n}{sup Z{sub C}} salts (A=anion, C=cation, z= valence) with the greatest Z{sub A}/Z{sub C} ratio. Our results strongly support a Donnan-type rejection mechanism, dominated by electrostatic interactions between fixed membrane charges and mobile ions, while steric and hydrodynamic effects appear to be less important. Comparison with commercial nanofiltration membranes for water softening reveals that our carbon nanotube membranes provides far superior water fluxes for similar ion rejection capabilities.

36 MATERIALS SCIENCE↗

Numerical Simulation and Optimization of the Thermodynamic Process of the Molten Salt Furnace

In this paper, a numerical model of the molten salt furnace process was developed, by using computational fluid dynamics (CFD) technique and considering the gas flow, the combustion and the radiation heat transfer. The results demonstrate that the performances of the salt furnace could be improved by optimization using the numerical model. The temperatures along the circumference of the furnace coil and outside shell are quite even, and the deviant combustion phenomenon is not observed. A back-flow formed in the upper part of the furnace chamber enhances the circulation and the mixing of the gas and effectively stabilizes the combustion in the furnace. The behaviors of CO, CO 2 , NO x , and H 2 O are presented in terms of the gas flow, temperature distribution and volumetric concentration distribution. It is concluded that the furnace with the constant air flow rate of 15,500 Nm 3 /h and the guiding vane angle at 48–50 deg is optimized for the combustion effectiveness.

42 ENGINEERING↗

The Physics of Cooling Flow Clusters with Central Radio Sources

Central galaxies in rich clusters are the sites of cluster cooling flows, with large masses of gas cooling through part of the X-ray band. Many of these galaxies host powerful radio sources. These sources can displace and compress the X-ray gas leading to enhanced cooling and star formation. We observed the bright cooling flow Abell 2626 with a strangely distorted central radio source. We wished to understand the interaction of radio and X-ray thermal plasma, and to determine the dynamical nature of this cluster. One aim was to constrain the source of additional pressure in radio "holes" in the X-ray emission needed to support overlying shells of X-ray gas. We also aimed to study the problem of the lack of kT < 1-2 keV gas in cooling flows by searching for abundance inhomogeneities, heating from the radio source, and excess absorption. We also have a Chandra observation of this cluster. There were problems with the pipeline processing of this data due to a telemetry dropout. We are publishing the Chandra and XMM data together. Delays with the Chandra data have slowed up the publication. At the center of the cluster, there is a complex interaction of the odd, Z-shaped radio source, and the X-ray plasma. However, there are no clear radio bubbles. Also, the cluster SO galaxy IC 5337, which is projected 1.5 arcmin west of the cluster center, has unusual tail-like structures in both the radio and X-ray. It appears to be falling into the cluster center. There is a hot, probably shocked region of gas to the southwest, which is apparently due to the merger of a subcluster in this part of the system. There is also a merging subcluster to the northeast. The axes of these two mergers agrees with a supercluster filament structure.

Sarazin, Craig L.↗

Plutonium partitioning in uranium and plutonium co-recovery system for fast reactor fuel recycling with enhanced nuclear proliferation resistance

For enhancement of nuclear proliferation resistance, a 'co-processing' method for U and Pu co-recovery was studied. Two concepts, no U scrubbing and no Pu reduction partitioning, were employed to formulate two types of flow sheets by using a calculation code. Their process performance was demonstrated using radioactive solutions derived from an irradiated fast reactor fuel. These experimental results indicated that U and Pu were co-recovered in the U/Pu product, and the Pu content in the U/Pu product increased approximately 2.3 times regardless of using reductant. The proposed no U scrubbing and no Pu reductant flow sheet is applicable to fast reactor fuel reprocessing and enhances its resistance to nuclear proliferation. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Biomass drying in a pulsed fluidized bed without inert bed particles

Batch drying was performed in the pulsed fluidized bed with various species of biomass particles as an indicator of gas–solid contact efficiency and mass transfer rate under different operating conditions including pulsation duty cycle and particle size distribution. The fluidization of cohesive biomass particles benefited from the shorter opening time of pulsed gas flow and increased peak pressure drop. The presence of fines enhanced gas–solid contact of large and irregular biomass particles, as well as the mass transfer efficiency. A drying model based on two-phase theory was proposed, from which effective diffusivity was calculated for various gas flow rates, temperature and pulsation frequency. Intricate relationship was discovered between pulsation frequency and effective diffusivity, as mass transfer was deeply connected with the hydrodynamics. Effective diffusivity was also found to be proportional to gas flow rate and drying temperature. In conclusion, operating near the natural frequency of the system also favored drying and mass transfer.

09 BIOMASS FUELS↗

Exploiting 20 Ne Isotopes for Precision Characterizations of Collectivity in Small Systems

Whether or not femto-scale droplets of quark-gluon plasma (QGP) are formed in so-called small systems at high-energy colliders is a pressing question in the phenomenology of the strong interaction. For proton-proton or proton-nucleus collisions the answer is inconclusive due to the large theoretical uncertainties plaguing the description of these processes. While upcoming data on collisions of 16 O nuclei may mitigate these uncertainties in the near future, here we demonstrate the unique possibilities offered by complementing 16 O + 16 O data with collisions of 20 Ne ions. We couple both nuclear lattice effective field theory (NLEFT) and projected generator coordinate method (PGCM) ab initio descriptions of the structure of 20 Ne and 16 O to hydrodynamic simulations of 16 O + 16 O and 20 Ne + 20 Ne collisions at high energy. We isolate the imprints of the bowling-pin shape of 20 Ne on the collective flow of hadrons, which can be used to perform quantitative tests of the hydrodynamic QGP paradigm. In particular, we predict that the elliptic flow of 20 Ne + 20 Ne collisions is enhanced by as much as 1.174⁢(8) stat ⁢(31) syst for NLEFT and 1.139⁢(6) stat ⁢(39) syst for PGCM relative to 16 O + 16 O collisions for the 1% most central events. At the same time, theoretical uncertainties largely cancel when studying relative variations of observables between two systems. This demonstrates a method based on experiments with two light-ion species for precision characterizations of the collective dynamics and its emergence in a small system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A comparative investigation of the effect of gas type on foam strength and flow behavior in tight carbonates

Foam generation technique has been practically applied to overcome gas mobility issue during enhanced oil recovery (EOR) processes. Incorporated with the utilized gas, the capability of foaming agent to generate persistent foam determines the flow performance under reservoir conditions. Here, in this study, we first identified the surfactants with excellent phase behavior and foaming properties and, second, evaluated their bulk foam performance with different gases, including N 2 , CO 2 , and hydrocarbon gas (CH 4 ) under high-pressure and high-temperature conditions. In bulk, the foam generated with the high-density gas, i.e., CO 2 , exhibited the greatest foamability but the lowest foam stability. With amidoamine oxide-based surfactant, CH 4 -foam was found to be more stable than N 2 -foam, while the opposite was observed for sulfobetaine-based surfactant. The most effective surfactant was later used to perform flow experiments on two tight carbonate rocks, including Minnesota Norther Cream Buff and Edwards limestone, with permeabilities of ~0.8 and 16 mD, respectively. The core-flooding experiments showed that the optimum quality of CO 2 -foam was lower than that of N 2 - and CH 4 -foams. For a given flow rate and fixed foam quality, the steady-state strength followed the descending order of CH 4 -, N 2 -, and CO 2 -foam. However, in general, the difference in foam strength between N 2 - and CH 4 -foams was insignificant when the total flow rate was varied. We also found that the variation in rock permeability had a greater effect on the strength of the CO 2 -foam compared to those generated with N 2 and CH 4 . In the presence of oil, the shear-thinning behavior of all foams was found more prominent. The increase in oil saturation had a more adverse effect on the strength of N 2 - and CH 4 -foams, particularly in the higher permeability rock. The results indicated that the foam strength, which is key in the effectiveness of foam EOR applications, is greatly influenced by several factors such as gas density, gas solubility in water, the presence of oil, and rock permeability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonequilibrium Physics of Multiphase Flow in Porous Media: Wettability and Disorder

Carbon capture and geologic storage, dissociation of methane hydrates in permafrost, enhanced oil recovery, and water dropout in low-temperature fuel cells, all have something in common: two or more fluids flow simultaneously through a porous medium; and the displacement of one fluid by another is often unstable (either due to gravity or viscous forces). Yet, our ability to model multiphase flow in porous media has remained a challenge. The traditional equations are unable to predict, explain, or even reproduce, the formation of the complex patterns observed in experiments. The overarching goal of the project is to develop new physical understanding of the role of wettability and disorder in multiphase flow through permeable media, and to develop new mathematical and computational models at the pore scale and at the continuum scale.

58 GEOSCIENCES↗