Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

New results in fault latency modelling

The test design and results from assessment of the performance of the self-test program and the extent of fault latency in a redundant flight control system (FCS) are reported. Assembly language programming generated gate-level faults directed to every avionics component. Details of the fault-simulation software are described, noting the input needed to match the five control-surface parameters managed by the FCS. Most faults were immediately detected, and component-level faults, occurring at pins, were more easily noted than gate-level faults. The results indicated that a 200-word self-test program is sufficient to obtain a fault coverage of 85 percent. Minor hardware changes are required to reach levels over 90 percent.

Mcgough, J. G.↗

Emerging technologies for V&V of ISHM software for space exploration

Systems1,2 required to exhibit high operational reliability often rely on some form of fault protection to recognize and respond to faults, preventing faults' escalation to catastrophic failures. Integrated System Health Management (ISHM) extends the functionality of fault protection to both scale to more complex systems (and systems of systems), and to maintain capability rather than just avert catastrophe. Forms of ISHM have been utilized to good effect in the maintenance phase of systems' total lifecycles (often referred to as 'condition-based mainte-nance'), but less so in a 'fault protection' role during actual operations. One of the impediments to such use lies in the challenges of verification, validation and certification of ISHM systems themselves. This paper makes the case that state-of-the-practice V&V and certification techniques will not suffice for emerging forms of ISHM systems; however, a number of maturing software engineering assurance technologies show particular promise for addressing these ISHM V&V challenges.

fault detection, isolation, and recovery↗

Anomaly detection in PV systems using constrained low-rank and sparse decomposition

PV (photovoltaic) systems, also known as solar panel systems, play an essential role in the mitigation of greenhouse gas emissions and the promotion of renewable energy. Through the conversion of sunlight into usable energy, electricity is generated without emitting greenhouse gases and producing pollutants. Notwithstanding the evolutionary significance of PV systems, the occurrence of defects and anomalies in PV systems may result in diminished power output, consequently impeding the efficiency of the systems and potentially resulting in hazards in certain circumstances. Therefore, early detection of faults and anomalies in PV systems is imperative to guarantee the reliability, efficiency, and safety of the systems. In this article, we develop a signal decomposition for the purpose of anomaly detection in PV systems. The proposed methodology is grounded on the concept of low-rank and sparse decomposition, with consideration given to the signs of the decomposed low-rank and sparse components, as well as the smooth variations within and between periods in the mean signals. Through the implementation of Monte Carlo simulations, we showcase the efficacy of our proposed methodology in identifying anomalies of varying durations and magnitudes in PV systems. A case study is employed to validate the proposed methodology in detecting anomalies in real PV systems.

14 SOLAR ENERGY↗

A Current Limiting Control Strategy for Single-Loop Droop-Controlled Grid-Forming Inverters Under Balanced and Unbalanced Faults

Existing studies reporting current limiting control strategies for grid-forming inverters primarily focus on grid-forming inverters that use a multi-loop control structure. This study reports a current limiting control for grid-forming inverters that uses a single-loop control structure. The proposed current limiting control was implemented at the pulse width modulation (PWM) control layer to guarantee a rapid response. Once an overcurrent caused by severe faults is detected, the proposed control strategy immediately blocks relevant insulated-gate bipolar transistors (IGBTs) using a hysteresis loop, ensuring that the overcurrent is limited within a few PWM cycles. After the fault is cleared, the inverter seamlessly transfers back to droop control mode to maintain stability. The current limiting control has been tested in a microgrid environment operating in the OPAL-RT platform. Study results show that the control strategy can effectively limit the overcurrent under both balanced and unbalanced faults and can maintain system transient stability after the fault is cleared.

Du, Wei↗

Underground technology benefits surface operations

Sensitive ground fault relays (GFRs) on high voltage underground electrical equipment have been in used for a number of years to improve mine safety. Advanced GFRs do more than just interrupt fault current flow. They can also reveal linkages as they develop so ground faults are detected before they become critical. 3 figs.

01 COAL, LIGNITE, AND PEAT↗

Practical Issues in Implementing Software Reliability Measurement

Many ways of estimating software systems' reliability, or reliability-related quantities, have been developed over the past several years. Of particular interest are methods that can be used to estimate a software system's fault content prior to test, or to discriminate between components that are fault-prone and those that are not. The results of these methods can be used to: 1) More accurately focus scarce fault identification resources on those portions of a software system most in need of it. 2) Estimate and forecast the risk of exposure to residual faults in a software system during operation, and develop risk and safety criteria to guide the release of a software system to fielded use. 3) Estimate the efficiency of test suites in detecting residual faults. 4) Estimate the stability of the software maintenance process.

Nikora, Allen P.↗

Design and evaluation of a fault-tolerant multiprocessor using hardware recovery blocks

A fault-tolerant multiprocessor with a rollback recovery mechanism is discussed. The rollback mechanism is based on the hardware recovery block which is a hardware equivalent to the software recovery block. The hardware recovery block is constructed by consecutive state-save operations and several state-save units in every processor and memory module. When a fault is detected, the multiprocessor reconfigures itself to replace the faulty component and then the process originally assigned to the faulty component retreats to one of the previously saved states in order to resume fault-free execution. A mathematical model is proposed to calculate both the coverage of multi-step rollback recovery and the risk of restart. A performance evaluation in terms of task execution time is also presented.

Lee, Y. H.↗

Fault Management Metrics

This paper describes the theory and considerations in the application of metrics to measure the effectiveness of fault management. Fault management refers here to the operational aspect of system health management, and as such is considered as a meta-control loop that operates to preserve or maximize the system's ability to achieve its goals in the face of current or prospective failure. As a suite of control loops, the metrics to estimate and measure the effectiveness of fault management are similar to those of classical control loops in being divided into two major classes: state estimation, and state control. State estimation metrics can be classified into lower-level subdivisions for detection coverage, detection effectiveness, fault isolation and fault identification (diagnostics), and failure prognosis. State control metrics can be classified into response determination effectiveness and response effectiveness. These metrics are applied to each and every fault management control loop in the system, for each failure to which they apply, and probabilistically summed to determine the effectiveness of these fault management control loops to preserve the relevant system goals that they are intended to protect.

Johnson, Stephen B.↗

Power System Event Classification and Localization Using a Convolutional Neural Network

Detection and timely identification of power system disturbances are essential for situation awareness and reliable electricity grid operation. Because records of actual events in the system are limited, ensemble simulation-based events are needed to provide adequate data for building event-detection models through deep learning; e.g., a convolutional neural network (CNN). An ensemble numerical simulation-based training data set have been generated through dynamic simulations performed on the Polish system with various types of faults in different locations. Such data augmentation is proven to be able to provide adequate data for deep learning. The synchronous generators’ frequency signals are used and encoded into images for developing and evaluating CNN models for classification of fault types and locations. With a time-domain stacked image set as the benchmark, two different time-series encoding approaches, i.e., wavelet decomposition-based frequency-domain stacking and polar coordinate system-based Gramian Angular Field (GAF) stacking, are also adopted to evaluate and compare the CNN model performance and applicability. The various encoding approaches are suitable for different fault types and spatial zonation. With optimized settings of the developed CNN models, the classification and localization accuracies can go beyond 84 and 91%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geodetic Measurements of Slow-Slip Events Southeast of Parkfield, CA

Tremor and low-frequency earthquakes are presumed to be indicative of surrounding slow, aseismic slip that is often below geodetic detection thresholds. This study uses data from borehole seismometers and long-baseline laser strainmeters to observe both the seismic and geodetic signatures of episodic tremor and slip on the Parkfield region of the San Andreas Fault near Cholame, CA. We note the observed occurrence rates of both the tremors and co-located families of low-frequency earthquakes are not steady but instead exhibit quasiperiodic bursts of increased activity.We show that these periods of elevated seismic activity correlate with statistically significant stacked strain signals consisting of 44 slow-slip events. Modeled individual slow-slip events and their total summed moment, which are constrained by seismic signals and stacked strain, respectively, indicate that the individual moment magnitudes of these events range from $M_w$ 4.6–5.2.We find that the measured geodetic signal likely precedes the seismic signal by several hours, consistent with the aseismic slip preceding and driving the observed seismic tremor activity.We confirm that strike-slip faults, in addition to subduction zones, are capable of producing episodic tremor and slip.

58 GEOSCIENCES↗

Spacecraft fault tolerance: The Magellan experience

Interplanetary and earth orbiting missions are now imposing unique fault tolerant requirements upon spacecraft design. Mission success is the prime motivator for building spacecraft with fault tolerant systems. The Magellan spacecraft had many such requirements imposed upon its design. Magellan met these requirements by building redundancy into all the major subsystem components and designing the onboard hardware and software with the capability to detect a fault, isolate it to a component, and issue commands to achieve a back-up configuration. This discussion is limited to fault protection, which is the autonomous capability to respond to a fault. The Magellan fault protection design is discussed, as well as the developmental and flight experiences and a summary of the lessons learned.

Kasuda, Rick↗

Detecting and Characterizing Fracture Zones Using a Convolutional Neural Network

This project directly supports the Geothermal Technologies Office (GTO) objectives outlined in the Multi-Year Program Plan (MYPP) by advancing two key research areas: “Exploration and Characterization” and “Data, Modeling, and Analysis.” This project has successfully demonstrated a pre-drilling ability to image and characterize the distribution and connectivity of subsurface faults and fractures, key parameters for identifying permeable pathways that enable geothermal fluids to circulate and produce energy. Specifically, we developed and implemented innovative machine learning methodologies to enhance geothermal exploration. Large-scale faults were detected using a Convolutional Neural Network (CNN), while small-scale fractures were characterized using a novel Double-Beam Neural Network (DBNN). These tools have proven both technically effective and cost-efficient by reducing reliance on expensive exploratory drilling. Through collaboration with our geothermal industry partner, this research has significantly advanced techniques for identifying hidden geothermal systems and extending the productive lifespan of existing geothermal fields. We applied our methods to two geothermal fields—Soda Lake (Nevada) and Lightning Dock (New Mexico)—to identify shallow steam-charged fracture zones and characterize deep faults at depths of 1.5-2 km. The steam zone identified at the Soda Lake geothermal field showed excellent agreement with prior drilling data, validating the effectiveness of our approaches. In addition, the analysis revealed three new prospective drilling targets for further development and verification. The outcomes of this project improve our scientific understanding of geothermal reservoir behavior, enhance exploration efficiency, extend the economic life of existing geothermal plants. Ultimately, these advancements contribute to GTO’s goal of achieving more sustainable, affordable, and data-driven geothermal energy development across the United States.

15 GEOTHERMAL ENERGY↗

Identifying an arc-fault type in photovoltaic arrays

An apparatus, method, and system for detecting arc-faults in a photovoltaic array are disclosed. Further, the detection not only identifies that an arc-fault is present in the array, but also classifies whether the arc-fault is a series type arc-fault or a parallel type arc-fault. Upon determination of the specific type of arc-fault that is at issue, de-energizing the arc-fault specific to the type is selected and carried out.

42 ENGINEERING↗

Compiler-Assisted Detection of Transient Memory Errors

The probability of bit flips in hardware memory systems is projected to increase significantly as memory systems continue to scale in size and complexity. Effective hardware-based error detection and correction requires that the complete data path, involving all parts of the memory system, be protected with sufficient redundancy. First, this may be costly to employ on commodity computing platforms and second, even on high-end systems, protection against multi-bit errors may be lacking. Therefore, augmenting hardware error detection schemes with software techniques is of consider- able interest. In this paper, we consider software-level mechanisms to comprehensively detect transient memory faults. We develop novel compile-time algorithms to instrument application programs with checksum computation codes so as to detect memory errors. Unlike prior approaches that employ checksums on computational and architectural state, our scheme verifies every data access and works by tracking variables as they are produced and consumed. Experimental evaluation demonstrates that the proposed comprehensive error detection solution is viable as a completely software-only scheme. We also demonstrate that with limited hardware support, overheads of error detection can be further reduced.

def-use analysis↗

Modeling Data Flows with Network Calculus in Cyber-Physical Systems: Enabling Feature Analysis for Anomaly Detection Applications

The electric grid is becoming increasingly cyber-physical with the addition of smart technologies, new communication interfaces, and automated grid-support functions. Because of this, it is no longer sufficient to only study the physical system dynamics, but the cyber system must also be monitored as well to examine cyber-physical interactions and effects on the overall system. To address this gap for both operational and security needs, cyber-physical situational awareness is needed to monitor the system to detect any faults or malicious activity. Techniques and models to understand the physical system (the power system operation) exist, but methods to study the cyber system are needed, which can assist in understanding how the network traffic and changes to network conditions affect applications such as data analysis, intrusion detection systems (IDS), and anomaly detection. In this paper, we examine and develop models of data flows in communication networks of cyber-physical systems (CPSs) and explore how network calculus can be utilized to develop those models for CPSs, with a focus on anomaly and intrusion detection. This provides a foundation for methods to examine how changes to behavior in the CPS can be modeled and for investigating cyber effects in CPSs in anomaly detection applications.

97 MATHEMATICS AND COMPUTING↗

Towards Real-Time, On-Board, Hardware-Supported Sensor and Software Health Management for Unmanned Aerial Systems

For unmanned aerial systems (UAS) to be successfully deployed and integrated within the national airspace, it is imperative that they possess the capability to effectively complete their missions without compromising the safety of other aircraft, as well as persons and property on the ground. This necessity creates a natural requirement for UAS that can respond to uncertain environmental conditions and emergent failures in real-time, with robustness and resilience close enough to those of manned systems. We introduce a system that meets this requirement with the design of a real-time onboard system health management (SHM) capability to continuously monitor sensors, software, and hardware components. This system can detect and diagnose failures and violations of safety or performance rules during the flight of a UAS. Our approach to SHM is three-pronged, providing: (1) real-time monitoring of sensor and software signals; (2) signal analysis, preprocessing, and advanced on-the-fly temporal and Bayesian probabilistic fault diagnosis; and (3) an unobtrusive, lightweight, read-only, low-power realization using Field Programmable Gate Arrays (FPGAs) that avoids overburdening limited computing resources or costly re-certification of flight software. We call this approach rt-R2U2, a name derived from its requirements. Our implementation provides a novel approach of combining modular building blocks, integrating responsive runtime monitoring of temporal logic system safety requirements with model-based diagnosis and Bayesian network-based probabilistic analysis. We demonstrate this approach using actual flight data from the NASA Swift UAS.

Unmanned Aerial System↗

New data-driven approach to bridging power system protection gaps with deep learning

Protection is a critical function in power systems to avoid equipment damage, maintain personnel safety, and support system reliability. However, current protective relay technology cannot adequately protect equipment and personnel from effects of some events; these deficiencies are termed protection gaps. In this paper, a data-driven approach is proposed to complement traditional protection technology and distinguish fault conditions from transients caused by normal operations. A combined convolutional neural network and long short-term memory (CNN-LSTM) network is implemented to achieve data translation invariance and capture the temporal correlation of the time-series input data. As a result, the data-driven method can accurately detect system faults despite variation and noise in the input data. In addition, using the CNN-LSTM--based method avoids the complicated, manual feature extraction procedure required by many traditional data-driven methods. The effectiveness of the proposed approach is tested on two kinds of protection gaps: high-impedance faults and transformer inter-turn faults. Lastly, a transfer learning method is also proposed to address the common issue of data-driven methods for which real-world training data are scarce. Extensive study results demonstrate that the proposed approach can accurately bridge power system protection gaps.

42 ENGINEERING↗