Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

PULSAR TIMING ERRORS FROM ASYNCHRONOUS MULTI-FREQUENCY SAMPLING OF DISPERSION MEASURE VARIATIONS

Free electrons in the interstellar medium cause frequency-dependent delays in pulse arrival times due to both scattering and dispersion. Multi-frequency measurements are used to estimate and remove dispersion delays. In this paper, we focus on the effect of any non-simultaneity of multi-frequency observations on dispersive delay estimation and removal. Interstellar density variations combined with changes in the line of sight from pulsar and observer motions cause dispersion measure (DM) variations with an approximately power-law power spectrum, augmented in some cases by linear trends. We simulate time series, estimate the magnitude and statistical properties of timing errors that result from non-simultaneous observations, and derive prescriptions for data acquisition that are needed in order to achieve a specified timing precision. For nearby, highly stable pulsars, measurements need to be simultaneous to within about one day in order for the timing error from asynchronous DM correction to be less than about 10 ns. We discuss how timing precision improves when increasing the number of dual-frequency observations used in DM estimation for a given epoch. For a Kolmogorov wavenumber spectrum, we find about a factor of two improvement in precision timing when increasing from two to three observations but diminishing returns thereafter.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental studies of high-confinement mode plasma response to non-axisymmetric magnetic perturbations in ASDEX Upgrade

Here, the interaction of externally applied small non-axisymmetric magnetic perturbations (MP) with tokamak high-confinement mode (H-mode) plasmas is reviewed and illustrated by recent experiments in ASDEX Upgrade. The plasma response to the vacuum MP field is amplified by stable ideal kink modes with low toroidal mode number n driven by the H-mode edge pressure gradient (and associated bootstrap current) which is experimentally evidenced by an observable shift of the poloidal mode number m away from field alignment (m = qn, with q being the safety factor) at the response maximum. A torque scan experiment demonstrates the importance of the perpendicular electron flow for shielding of the resonant magnetic perturbation, as expected from a two-fluid MHD picture. Two significant effects of MP occur in H-mode plasmas at low pedestal collisionality, $\nu _{\text{ped}}^{\ast}\leqslant 0.4$ : (a) a reduction of the global plasma density by up to $61 \% $ and (b) a reduction of the energy loss associated with edge localised modes (ELMs) by a factor of up to 9. A comprehensive database of ELM mitigation pulses at low ${{\nu}^{\ast}}$ in ASDEX Upgrade shows that the degree of ELM mitigation correlates with the reduction of pedestal pressure which in turn is limited and defined by the onset of ELMs, i. e. a modification of the ELM stability limit by the magnetic perturbation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determining Metastable Ion Lifetime and History through Wave-Particle Interaction

Laser-induced fluorescence (LIF) performed on metastable ions is frequently used to probe the dynamics of ground-state ion motions in many laboratory plasmas. However, these measurements place restrictions on the metastable ion lifetime. Metastable states are produced from direct ionization of neutral atoms as well as ions in other electronic states, of which the former will only faithfully represent processes that act on the ion dynamics in a time shorter than the metastable lifetime. We present here the first experimental study of this type of systematic effect using wave-particle interaction in an argon multidipole plasma. Furthermore, the metastable lifetime and relative fraction of metastables produced from preexisting ions, necessary for correcting the LIF measurement errors, can be determined by fitting the experimental results with the theory we propose.

74 ATOMIC AND MOLECULAR PHYSICS↗

Registration of the rotation axis in X-ray tomography

There is high demand for efficient, robust and automated routines for tomographic data reduction, particularly for synchrotron data. Registration of the rotation axis in data processing is a critical step affecting the quality of the reconstruction and is not easily implemented with automation. Existing methods for calculating the center of rotation have been reviewed and an improved algorithm to register the rotation axis in tomographic data is presented. The performance of the proposed method is evaluated using synchrotron-based microtomography data on geological samples with and without artificial reduction of the signal-to-noise ratio. The proposed method improves the reconstruction quality by correcting both the tilting error and the translational offset of the rotation axis. The limitation of this promising method is also discussed.

rotation axis↗

Field Quality Measurement of a 4.2-m-Long Prototype Low- $\beta$ Nb $_3$ Sn Quadrupole Magnet During the Assembly Stage for the High-Luminosity LHC Accelerator Upgrade Project

The U.S. High-Luminosity LHC Accelerator Upgrade Project, in collaboration with CERN, is developing Nb 3 Sn quadrupole magnets (MQXFA) to be installed at the interaction region of the LHC. The project will deliver 20 MQXFA magnets in 10 cold masses. These magnets need to meet the stringent requirements on field quality at the nominal operating current. Compared to the mature NbTi accelerator magnet technology, achieving excellent field quality can be challenging for Nb 3 Sn magnets. To help track, understand, and allow effective correction of geometric field errors, field quality measurements at room temperature during the MQXFA assembly stage was planned for the project. The measurements also intend to evaluate the magnetic axis and twist angle along the magnet aperture. We report the first measurement on a prototype MQXFA magnet using a recently developed measurement system. The magnetic axis and twist angle met the acceptance criteria. Further development needs for the room-temperature measurements were discussed. Here, we expect that statistics obtained from such measurements throughout the project will provide insight into future applications of high-performance Nb 3 Sn accelerator magnets.

43 PARTICLE ACCELERATORS↗

Raytracing the long trace profiler

The optical design of the Long Trace Profiler optical system is explored with a commercial raytrace program, Zemax OpticStudio™ (ZOS)1, with the intent of finding and correcting sources of systematic error. ZOS provides both geometric raytracing tools and physical optics Gaussian beam propagation and diffraction image calculation tools, and two design modes, sequential component (SC) and non-sequential component (NSC) that are optimized for different aspects of the design process. The original LTP-II system employs a singlet lens with a 1250 mm focal length. It is optimized to provide minimum distortion over a surface slope angle range of ±5 mrad. Using the ZOS tools, we are able to simulate ghost rays that produce distortion in the beam spot image and can minimize the distortion by deliberate misalignment of the beamsplitter (BS) components. Unfortunately, the reference beam is compromised because of the component tilts. The most recent LTP500 system design simplifies the optical system and makes the reference beam usable again, even with misalignment of the polarizing beamsplitter (PBS). Two lenses are designed for the LTP500 - a cemented doublet that has been fabricated, and a singlet with one aspheric surface. Both have focal distances of 500 mm with an expanded angular measurement range of ±10 mrad. The aspheric singlet provides superior performance. ZOS allows the import of wavefront measurement data produced by commercial interferometer software. We apply the wavefront error measurement from the cemented doublet to the model to show that the 19nm RMS wavefront error needs to be improved by at least a factor of ten in order to reduce the systematic error to a level that will allow the LTP to approach its design limit of a few tens of nanoradians.

Takacs, Peter Z.↗

SU-E-T-68: A Quality Assurance System with a Web Camera for High Dose Rate Brachytherapy

Purpose: The purpose of this work was to develop a quality assurance (QA) system for high dose rate (HDR) brachytherapy to verify the absolute position of an 192Ir source in real time and to measure dwell time and position of the source simultaneously with a movie recorded by a web camera. Methods: A web camera was fixed 15 cm above a source position check ruler to monitor and record 30 samples of the source position per second over a range of 8.0 cm, from 1425 mm to 1505 mm. Each frame had a matrix size of 480×640 in the movie. The source position was automatically quantified from the movie using in-house software (built with LabVIEW) that applied a template-matching technique. The source edge detected by the software on each frame was corrected to reduce position errors induced by incident light from an oblique direction. The dwell time was calculated by differential processing to displacement of the source. The performance of this QA system was illustrated by recording simple plans and comparing the measured dwell positions and time with the planned parameters. Results: This QA system allowed verification of the absolute position of the source in real time. The mean difference between automatic and manual detection of the source edge was 0.04 ± 0.04 mm. Absolute position error can be determined within an accuracy of 1.0 mm at dwell points of 1430, 1440, 1450, 1460, 1470, 1480, 1490, and 1500 mm, in three step sizes and dwell time errors, with an accuracy of 0.1% in more than 10.0 sec of planned time. The mean step size error was 0.1 ± 0.1 mm for a step size of 10.0 mm. Conclusion: This QA system provides quick verifications of the dwell position and time, with high accuracy, for HDR brachytherapy. This work was supported by the Japan Society for the Promotion of Science Core-to-Core program (No. 23003)

60 APPLIED LIFE SCIENCES↗

SU-F-T-320: Assessing Placement Error of Optically Stimulated Luminescent in Vivo Dosimeters Using Cone-Beam Computed Tomography

Purpose: Optically-stimulated luminescent dosimeters (OSLDs) are increasingly utilized for in vivo dosimetry of complex radiation delivery techniques such as intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Evaluation of clinical uncertainties such as placement error has not been performed. This work retrospectively investigates the magnitude of placement error using conebeam computed tomography (CBCT) and its effect on measured/planned dose agreement. Methods: Each OSLD was placed at a physicist-designated location on the patient surface on a weekly basis. The location was given in terms of a gantry angle and two-dimensional offset from central axis. The OSLDs were placed before daily image guidance. We identified 77 CBCTs from 25 head-and-neck patients who received IMRT or VMAT, where OSLDs were visible on the CT image. Grossly misplaced OSLDs were excluded (e.g. wrong laterality). CBCTs were registered with the treatment plan and the distance between the planned and actual OSLD location was calculated in two dimensions in the beam’s eye view. Distances were correlated with measured/planned dose percent differences. Results: OSLDs were grossly misplaced for 5 CBCTs (6.4%). For the remaining 72 CBCTs, average placement error was 7.0±6.0 mm. These errors were not correlated with measured/planned dose percent differences (R{sup 2}=0.0153). Generalizing the dosimetric effect of placement errors may be unreliable. Conclusion: Correct placement of OSLDs for IMRT and VMAT treatments is critical to accurate and precise in vivo dosimetry. Small placement errors could produce large disagreement between measured and planned dose. Further work includes expansion to other treatment sites, examination of planned dose at the actual point of OSLD placement, and the influence of imageguided shifts on measured/planned dose agreement.

60 APPLIED LIFE SCIENCES↗

Global models predict clouds at the wrong time of day: Does it matter for radiation and climate?

Accurate prediction of future climate change hinges upon the ability of Earth system models (ESMs) to simulate clouds and their radiative effects. Even if an ESM can simulate the correct clouds, a systematic error in the amount of sunlight reflected by clouds (and, thus, cloud radiative effect) can exist if the clouds are simulated at the incorrect time of day. In this work, we develop an analytical model connecting diurnal cloud biases to emergent mean state radiative biases. With the use of satellite observations, we demonstrate that there are errors in the time of day that clouds are occurring in ESMs that would cause bias in shortwave cloud radiative effect (SWCRE) that is greater than 45% of the total SWCRE bias, but such errors in the cloud diurnal cycle are masked by other compensating errors, indicating that these ESMs are getting the right answer for the wrong reasons.

Geosciences↗

Fitting program for linear regressions according to Mahon (1996)

This program takes the users' Input data and fits a linear regression to it using the prescription presented by Mahon (1996). Compared to the commonly used York fit, this method has the correct prescription for measurement error propagation. This software should facilitate the proper fitting of measurements with a simple Interface.

Trappitsch, RetoG.↗

Random adaptive tool path for zonal optics fabrication

Deterministic optics fabrication using sub-aperture tools has been vital for manufacturing precision optical surfaces. The fabrication process requires the tool influence function and the tool path to calculate the dwell time that guides the tool to bring surface quality within tight design tolerances. Widely used spiral and raster paths may leave excess waviness from the tool path, and the unavoidable constant removal layer is added to obtain positive dwell time. This waviness can be removed by either using smaller tools sequentially or randomizing the tool path. However, the existing tool-path solutions can hardly adapt to different surface aperture shapes and localized surface errors. Process efficiency and accuracy are also not well considered in tool-path planning. We propose an innovative zonal Random Adaptive Path (RAP) to solve these problems in this study. Firstly, RAP can be flexibly adapted to different surface aperture shapes by introducing part boundary. Secondly, an average threshold strategy is used in the RAP planning to improve efficiency, enabling the surface errors to be selectively corrected. Finally, the threshold is performed in several passes within one processing cycle, each with its RAP, until the desired residual is achieved. The performance of the proposed RAP is studied by comparing it with the conventional tool paths. The results demonstrated that RAP takes the least processing time and achieves the best surface quality, which verifies the effectiveness of RAP in deterministic optics fabrication.

36 MATERIALS SCIENCE↗

Leaf gas exchange data, Nov 2018 and May 2019, Daintree Rainforest, Australia

This data package contains leaf gas exchange data for 11 canopy tree species in the control and drought treatments at the Daintree Rainforest Observatory in Queensland, Australia (AU-DRO) with the purpose of testing for differences in gas exchange between treatments. Data were collected at the end of the dry season (November 2018) and end of the wet season (May 2019). Using a canopy crane, large branches (>1 m) were collected from the top of the canopy and immediately placed in a bucket of water, upon which the LI-6800 leaf chamber was clamped onto a recently mature leaf with minimal herbivory. Measurements were recorded every 3 seconds for 3 minutes total. The species included in the dataset are: Castanospermum australe, Cleistanthus myrianthus, Cryptocarya mackinnoniana, Dysoxylum papuanum, Elaeocarpus angustifolius (Elaeocarpus grandis), Endiandra microneura, Mallotus paniculatus, Myristica globosa, Rockinghamia angustifolia, Synima cordierorum, Syzygium spp. The two data files included are: 1. LICOR_Data_AU_DRO_2019_GasEx.csv (a compilation of individual LICOR output files, with correction of user input errors such as incorrect species spelling) 2. ESS_DIVE_Data_AU_DRO_2019_GasEx.csv (selected variables and converted units from LICOR_Data_AU_DRO_2019_GasEx.csv to follow the standard gas exchange reporting format from Ely et al. 2021 Ecological Informatics). The metadata files included are: (3) ESS_DIVE_Metadata_AU_DRO_2019_GasEx.xlsx (4) File_Submission_Metadata_AU_DRP_2019_GasEx.xlsx (5) E-Field_Log_AU_DRO_2019_GasEx.xlsx (6) Data_Column_Description_AU_DRO_2019_GasEx.xlsx.

54 ENVIRONMENTAL SCIENCES↗

LOCO Application to NSLSII SR Dispersion and Beta Beating Correction

During the short run in early July, 2014, we made changes to the Matlab LOCO setup for NSLS-II and applied LOCO successfully to the machine. The MML setup was verified with I/O tests for all quadrupole families. The LOCO setup was further tested with an intentional quadrupole error. After the successful LOCO correction, the rms beta beat was reduced from the initial values of 5.5% x and 5.6% y, to 1.9% x and 1.0% y, respectively. The rms horizontal dispersion error was reduced from 21 mm to 6 mm. It is critical to keep the same closed orbit for LOCO correction to take effect. Because presently some correctors are nearly saturated, closed orbit cannot be controlled for additional iterations. We expect LOCO to achieve better optics correction after the orbit control is improved.

36 MATERIALS SCIENCE↗

Magnetic Tuning of a Quasi-Periodic Elliptically Polarized Undulator

A 2.8 m long quasi-periodic APPLE II type (Advanced Planar Polarized Light Emitter II) undulator, is being commissioned at National Synchrotron Light Source II (NSLS-II). It will service the Electron SpectroMicroscopy (ESM) beamline in the framework of the NEXT (NSLS-II Experimental Tools) project [1]. It has been designated to provide high brilliance photon beams with variable polarization from VUV to soft X-Rays. Although this EPU (Elliptically Polarizing Undulator) was procured as a turn-key device from Kyma [2], the vendor was only responsible for the mechanical frame and the control system. Sorting and assembly of the magnet modules and the magnetic field tuning - Shimming and Magic Finger- were performed at the NSLS-II Magnetic Measurement Lab. In this report the field optimization techniques implemented in-house to correct the undesirable phasedependent errors and the final results of the magnetic tuning will be described together with the spectral performance of the device.

36 MATERIALS SCIENCE↗

Capacitive/Inductive Corrections for Numerical Implementation of Thin-Slot Transmission Line Models and Other Useful Formulas

Capacitance/inductance corrections for grid induced errors for a thin slot models are given for both one and four point testing on a rectangular grid for surface currents surrounding the slot. In addition a formula for translating from one equivalent radius to another is given for the thin-slot transmission line model. Additional formulas useful for this slot modeling are also given.

42 ENGINEERING↗

A Proof for the Unbiased Nature of Range-Doppler Measurements in Coarse-Resolution Dechirp-on-Receive Feedback Synthetic Aperture Radar Navigation

In feedback synthetic aperture radar (SAR) navigation, observables extracted from SAR range-Doppler images correct position and velocity errors accumulated within an associated navigation system. Unlike most other sensors, which produce measurements without input from a navigation system, SARs require a prior estimate of the radar’s position and velocity to adjust the radar’s matched filter during range-Doppler image formation. Consequently, it is possible for position and velocity errors within a navigation system to manifest as additional errors (biases) in the range-Doppler measurement observables. Prior work has not tackled this possibility in the context of feedback SAR navigation with a dechirp-on-receive radar. This paper offers a proof demonstrating that range-Doppler observables extracted from coarse-resolution vertical SAR images formed with a dechirp-on-receive radar may be safely modeled as unbiased measurements of the radar’s true position and velocity despite the presence of moderate navigation errors.

dechirp-on-receive↗

Erratum: “Tripling the Census of Dwarf AGN Candidates Using DESI Early Data” (2025, ApJ, 982, 10)

We identified an error in the EmFit code, which was employed to estimate the emission-line fluxes and widths used in the published article. Specifically, the error spectrum was not corrected for Galactic reddening before being incorporated into the fitting process. Although this does not affect the measured fluxes or line widths, it led to underestimated uncertainties. Consequently, the signal-to-noise ratios (SNRs) for individual sources were systematically overestimated, resulting in a larger number of sources satisfying a given SNR threshold.

Pucha, Ragadeepika [University of Utah, Salt Lake ↗