Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “engine modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Development of a Hybrid Lagrangian–Eulerian Model to Describe Spark-Ignition Processes at Engine-Like Turbulent Flow Conditions

With the engine technology moving toward more challenging (highly dilute and boosted) operation, spark-ignition processes play a key role in determining flame propagation and completeness of the combustion process. On the computational side, there is plenty of spark-ignition models available in literature and validated under conventional, stoichiometric spark ignition (SI) operation. Nevertheless, these models need to be expanded and developed on more physical grounds since at challenging operation they are not truly predictive. This paper reports on the development of a dedicated model for the spark-ignition event at nonquiescent, engine-like conditions, performed in the commercial CFD code converge. The developed methodology leverages previous findings that have expanded the use and improved the accuracy of Eulerian-type energy deposition models. In this work, the Eulerian energy deposition is coupled at every computational time-step with a Lagrangian-type evolution of the spark channel. Typical features such as spark channel elongation, stretch, and attachment to the electrodes are properly described to deliver realistic energy deposition along the channel during the entire ignition process. The numerical results are validated against schlieren images from an optical constant volume chamber and show the improvement in the simulation of the spark channel during the entire ignition event, with respect to the most commonly used energy deposition approach. Further developmental pathways are discussed to provide more physics-based features from the developed ignition model in the future.

42 ENGINEERING↗

Feasibility of Thermoelectrics for Waste Heat Recovery in Conventional Vehicles

Thermoelectric (TE) generators convert heat directly into electricity when a temperature gradient is applied across junctions of two dissimilar metals. The devices could increase the fuel economy of conventional vehicles by recapturing part of the waste heat from engine exhaust and generating electricity to power accessory loads. A simple vehicle and engine waste heat model showed that a Class 8 truck presents the least challenging requirements for TE system efficiency, mass, and cost; these trucks have a fairly high amount of exhaust waste heat, have low mass sensitivity, and travel many miles per year. These factors help maximize fuel savings and economic benefits. A driving/duty cycle analysis shows strong sensitivity of waste heat, and thus TE system electrical output, to vehicle speed and driving cycle. With a typical alternator, a TE system could allow electrification of 8%-15% of a Class 8 truck's accessories for 2%-3% fuel savings. More research should reduce system cost and improve economics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An experimental and modeling study investigating the ignition delay in a military diesel engine running hexadecane (cetane) fuel

In an effort aimed at predicting the combustion behavior of a new fuel in a conventional diesel engine, cetane (n-hexadecane) fuel was used in a military engine across the entire speed–load operating range. The ignition delay was characterized for this fuel at each operating condition. A chemical ignition delay was also predicted across the speed–load range using a detailed chemical kinetic mechanism with a constant pressure reactor model. At each operating condition, the measured in-cylinder pressure and predicted temperature at the start of injection were applied to the detailed n-hexadecane kinetic mechanism, and the chemical ignition delay was predicted without any kinetic mechanism calibration. The modeling results show that fuel–air parcels developed from the diesel spray with an equivalence ratio of 4 are the first to ignite. The chemical ignition delay results also showed decreasing igntion delays with increasing engine load and speed, just as the experimental data revealed. At lower engine speeds and loads, the kinetic modeling results show the characteristic two-stage negative temperature coefficient behavior of hydrocarbon fuels. However, at high engine speeds and loads, the reactions do not display negative temperature coefficient behavior, as the reactions proceed directly into high-temperature pathways due to higher temperatures and pressure at injection. A moderate difference between the total and chemical ignition delays was then characterized as a phyical delay period that scales inversely with engine speed. This physical delay time is representative of the diesel spray development time and is seen to become a minority fraction of the total igntion delay at higher engine speeds. In addition, the approach used in this study suggests that the ignition delay and thus start of combustion may be predicted with reasonable accuracy using kinetic modeling to determine the chemical igntion delay. Then, in conjunction with the physical delay time (experimental or modeling based), a new fuel’s acceptability in a conventional engine could be assessed by determining that the total ignition delay is not too short or too long.

30 DIRECT ENERGY CONVERSION↗

Supercomputer assisted generation of machine learning agents for the calibration of building energy models. In: XSEDE '13 Proceedings of the Conference on Extreme Science and Engineering Discovery Environment: Gateway to Discovery, Article No. 22

Building Energy Modeling (BEM) is an approach to model the energy usage in buildings for design and retrofit purposes. EnergyPlus is the flagship Department of Energy software that performs BEM for different types of buildings. The input to EnergyPlus can often extend in the order of a few thousand parameters which have to be calibrated manually by an expert for realistic energy modeling. This makes it challenging and expensive thereby making building energy modeling unfeasible for smaller projects. In this paper, we describe the "Autotune" research which employs machine learning algorithms to generate agents for the different kinds of standard reference buildings in the U.S. building stock. The parametric space and the variety of building locations and types make this a challenging computational problem necessitating the use of supercomputers. Millions of EnergyPlus simulations are run on supercomputers which are subsequently used to train machine learning algorithms to generate agents. These agents, once created, can then run in a fraction of the time thereby allowing cost-effective calibration of building models.

Sanyal, Jibonananda↗

The human factors verification at plant startup for the AP1000 Plant - 173

The Human Factors (HF) verification at plant startup is the final HF assessment for the AP1000{sup R} HF program and is performed using the as-built plant design. This HF verification has been implemented for the China AP1000 Standard Plant. The scope and objectives of the HF verification at plant startup met the requirements for Verification and Validation (V and V) as described in NUREG-0711, 'Human Factors Engineering Program Review Model'. The majority of the verifications have been completed. Overall, the results confirmed the adequacy of the China AP1000 Standard Plant operating procedures and operator training. A number of design issues were identified and were categorized as safety issues, operability and maintainability issues or minor issues. These issues are being addressed and tracked as site test deficiencies. Based on the current results, it can be concluded that the China AP1000 Standard Plant is safe, operable and maintainable, pending completion of the outstanding verifications and resolution of the identified issues. This paper will describe the overall strategy and discuss the lessons learned in respect to providing HF support to the startup activities for the AP1000 plant. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Volume-translated cubic EoS and PC-SAFT density models and a free volume-based viscosity model for hydrocarbons at extreme temperature and pressure conditions

This research focuses on providing the petroleum reservoir engineering community with robust models of hydrocarbon density and viscosity at the extreme temperature and pressure conditions (up to 533 K and 276 MPa, respectively) characteristic of ultra-deep reservoirs, such as those associated with the deepwater wells in the Gulf of Mexico. Our strategy is to base the volume-translated (VT) Peng–Robinson (PR) and Soave–Redlich–Kwong (SRK) cubic equations of state (EoSs) and perturbed-chain, statistical associating fluid theory (PC-SAFT) on an extensive data base of high temperature (278–533 K), high pressure (6.9–276 MPa) density rather than fitting the models to low pressure saturated liquid density data. This high-temperature, high-pressure (HTHP) data base consists of literature data for hydrocarbons ranging from methane to C{sub 40}. The three new models developed in this work, HTHP VT-PR EoS, HTHP VT-SRK EoS, and hybrid PC-SAFT, yield mean absolute percent deviation values (MAPD) for HTHP hydrocarbon density of ~2.0%, ~1.5%, and <1.0%, respectively. An effort was also made to provide accurate hydrocarbon viscosity models based on literature data. Viscosity values are estimated with the frictional theory (f-theory) and free volume (FV) theory of viscosity. The best results were obtained when the PC-SAFT equation was used to obtain both the attractive and repulsive pressure inputs to f-theory, and the density input to FV theory. Both viscosity models provide accurate results at pressures to 100 MPa but experimental and model results can deviate by more than 25% at pressures above 200 MPa.

02 PETROLEUM↗

CHASM Challenge Problem: Lagrangian Hydrodynamics

Computer simulations of many science and engineering problems require modeling the equations of hydrodynamics which describe the motion of materials relative to each other induced by various forces. Many important DoD simulation problems involve complex multi-material systems that undergo large deformations. Examples include the analysis of armor defense, penetration mechanics, blast effects, structural integrity, and conventional munitions such as shaped charges and explosively formed projectiles. Indeed, the original motivation for developing codes that solve the equations of hydrodynamics, herein referred to as “hydrocodes”, was to solve problems with defense applications. The FY2010 Requirements Analysis Report issued by the DoD High Performance Computing Modernization Program (HPCMP) Office shows that a major portion of DoD HPC activities involves hydrocodes [HPCMP2010]. The report surveyed 496 projects across the Services and various Agencies, representing 4,050 HPCMP users at more than 125 locations, including government, contractors, and academia, and grouped each project into one of ten categories.

42 ENGINEERING↗

Soot Formation and Ignition Characteristics of Ethanol/Gasoline Blends in a Rapid Compression Machine

With the ever-increasing demand for sustainable energy, alcohol fuels have garnered interest for use in heavy duty engines. The significant infrastructure for ethanol production and blending of ethanol with gasoline make these fuels/fuel blends desirable candidates. However, development of heavy duty engine technology that is capable of burning alcohol fuels while retaining the advantages of traditional diesel combustion requires an improved understanding of the soot formation for these fuels under conditions relevant to mixing-controlled combustion. This work uses an extinction diagnostic to study the sooting tendency of ethanol and gasoline/ethanol blends ranging from E10 to E98 during ignition in a homogeneous environment. Experiments were conducted in a rapid compression machine (RCM) for compressed conditions of 20 ± 1 bar and an approximately constant temperature (± 10K) which was unique for each fuel. For a given soot volume fraction, a linear relationship was observed between ethanol content and the equivalence ratio in which that soot volume fraction was formed. Accounting for the oxygenated nature of ethanol, E85 and E98 fuels produced similar amounts of soot at a given Φ ox, , suggesting other factors outside of fuel oxygen content, such as fuel morphology, impact soot formation. Ignition delay data is reported for compressed pressures of 20 ± 1 bar and compressed temperatures ranging from 633 – 670 K for E10 and 771 – 789 K for E98. Varying pressures for E10 and E98 at conditions producing similar soot volume fractions demonstrated a linear dependence of soot formation on pressure, regardless of if the pressure considered was at top dead center or peak combustion pressure. Furthermore, the data gleaned from this work will be used to select soot models and chemical kinetic mechanisms for RCM simulations to ultimately model heavy duty engine technology with the studied fuels.

33 ADVANCED PROPULSION SYSTEMS↗

Continuous Particulate Filter State of Health Monitoring Using Radio Frequency Sensing

Reliable means for on-board detection of particulate filter failures or malfunctions are needed to meet diagnostics (OBD) requirements. Detecting these failures, which result in tailpipe particulate matter (PM) emissions exceeding the OBD limit, over all operating conditions is challenging. Current approaches employ differential pressure sensors and downstream PM sensors, in combination with particulate filter and engine-out soot models. These conventional monitors typically operate over narrowly-defined time windows and do not provide a direct measure of the filter’s state of health. In contrast, radio frequency (RF) sensors, which transmit a wireless signal through the filter substrate provide a direct means for interrogating the condition of the filter itself. Here, this study investigated the use of RF sensors for the continuous measurement of filter trapping efficiency, which was compared to downstream measurements with an AVL Microsoot Sensor, and a PM sampling probe simulating the geometry and installation configuration of a conventional PM sensor. The study included several particulate filter failure modes, both above and below the OBD threshold. Finally, the results confirmed the use of RF sensors to provide a direct and continuous measure of the particulate filter’s state of health over a range of typical in-use operating conditions, thereby significantly increasing the time window over which filter failures may be detected.

42 ENGINEERING↗

A high efficiency rooftop air conditioning system using multi-speed compressors

This study delineates a meticulous exploration of technologies to enhance the energy efficiency of rooftop air conditioning units, employing the DOE/ORNL heat pump design model for comprehensive engineering design and optimization. A baseline rooftop air conditioning unit, featuring a 13 ton (45.7 kW) cooling capacity and a 17.9 integrated energy efficiency ratio, served as the point of departure for substantive efficiency enhancements. Key modifications included the consolidation of two refrigerant circuits into one, integrating three parallel 2-stage (dual-speed) compressors, fan replacements with high-efficiency substitutes. Notably, a lower global warming potential refrigerant, R452B, was evaluated as a substitute for R-410A, demonstrating better performance in the lab prototype. Further, the achieved measured integrated energy efficiency ratio of 21.4 in the lab prototype surpassed the baseline integrated energy efficiency ratio. Comparative evaluations between R410A and R452B indicated heightened efficiency with the latter, showcasing a lab-demonstrated integrated energy efficiency ratio of 22.4 at the rated capacity of 13.8 ton (48.5 kW) and 23.9 integrated energy efficiency ratio at the rated capacity of 10 ton (35.2 kW). This research underscores the successful development of a rigorous, energy efficient rooftop air conditioning unit prototype with noteworthy environmental and economic implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline Evaluations to Support Control Room Modernization at Nuclear Power Plants

For any major control room modernization activity at a commercial nuclear power plant (NPP) in the U.S., a utility should carefully follow the four phases prescribed by the U.S. Nuclear Regulatory Commission in NUREG-0711, Human Factors Engineering Program Review Model. These four phases include Planning and Analysis, Design, Verification and Validation, and Implementation and Operation. While NUREG-0711 is a useful guideline, it is written primarily from the perspective of regulatory review, and it therefore does not provide a nuanced account of many of the steps the utility might undertake as part of control room modernization. The guideline is largely summative—intended to catalog final products—rather than formative—intended to guide the overall modernization process. In this paper, we highlight two crucial formative sub-elements of the Planning and Analysis phase specific to control room modernization that are not covered in NUREG-0711. These two sub-elements are the usability and ergonomics baseline evaluations. A baseline evaluation entails evaluating the system as-built and currently in use. The usability baseline evaluation provides key insights into operator performance using the control system currently in place. The ergonomics baseline evaluation identifies possible deficiencies in the physical configuration of the control system. Both baseline evaluations feed into the design of the replacement system and subsequent summative benchmarking activities that help ensure that control room modernization represents a successful evolution of the control system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Human-System Interface Design Review Guidelines

The U.S. Nuclear Regulatory Commission (NRC) staff reviews the human factors engineering (HFE) aspects of nuclear power plants in accordance with the Standard Review Plan (NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition). The Human Factors Engineering Program Review Model (NUREG-0711, Revision 3, issued November 2012) contains detailed design review procedures. As part of the review process, the interfaces between plant personnel and the plant's systems and components are evaluated for conformance with HFE guidelines. This document, Human-System Interface Design Review Guidelines (NUREG-0700, Revision 3), provides the guidelines necessary to perform this evaluation. The review guidelines address the physical and functional characteristics of human-system interfaces (HSIs). Because these guidelines only address the HFE aspects of design and not other related considerations, such as instrumentation and control and structural design, they are referred to as HFE guidelines. In addition to the review of actual HSIs, the NRC staff can use the NUREG-0700 guidelines to evaluate a design-specific HFE guidelines document or style guide. The HFE guidelines are organized into four basic parts, which are divided into sections. Part I contains guidelines for the basic HSI elements: information displays, user-interface interaction and management, and analog displays and controls. These elements are used as building blocks to develop HSI systems to serve specific functions. Part II contains the guidelines for reviewing the following HSI systems: alarm system, safety parameter display system, group-view display system, soft control system, computer-based procedure system, automation system, and communication system. Part III provides guidelines for the review of workstations and workplaces. Part IV provides guidelines for the review of HSI support (i.e., maintainability of digital systems and degraded HSI and instrumentation and control conditions).

42 ENGINEERING↗

Microbial Curing of Cement for Energy Applications

Rutgers University, Lawrence Livermore National Laboratory, and the University of Arizona executed this program over 36 months with a 4-Task Program: (M1)-Microbial Engineering (M2)-Microstructure Modelling, (M3) Cement and Concrete Formulation, (M4)-Techno-economic analysis (TEA) and lifecycle assessment (LCA). This program developed a new carbonate cement concrete manufacturing process called microbial curing (MBC). MBC utilizes in-situ microbial production of CO 2 that dissolves into pore-bound water to carbonate a cementitious material creating a bonding matrix of CaCO 3 and SiO 2 that hardens and densifies the material. This is the first work of this type where calcium silicate was used in microbial studies. All other work reported in the literature always used a soluble form of calcium. This final report describes the work done in the final quarter, the best procedures and results, and the final techno-economic and lifecycle analyses. This quarter, we cast and cured twenty-five (4”x8”) cylinder samples. The compressive strength, split tensile, Young’s modulus, chloride permeability, and creep measurements were performed. These measurements demonstrated that MBC of calcium silicate concrete exhibits scaling problems due to the escape of ammonia gas, a product of the microbial reaction to generate CO 2 . As curing proceeds, the ability for the gas to escape from within the cylinder is restricted by the outer cylindrical portions densifying, making the outer portion highly impermeable to gas flow. In contrast, the small samples cured are uniformly cured, forming materials whose mechanical properties are 7x better than the large samples. This problem needs to be solved before this technology can be commercialized. The techno-economic and lifecycle analyses indicate that the technology developed in this program exhibits a significant opportunity to reduce the cost of cement and CO 2 emissions associated with concrete, provided the curing issue associated with larger samples can be addressed.

36 MATERIALS SCIENCE↗

Relation of validation experiments to applications.

Computational and mathematical models are developed in engineering to represent the behavior of physical systems to various system inputs and conditions. These models are often used to predict at other conditions, rather than to just reproduce the behavior of data obtained at the experimental conditions. For example, the boundary or initial conditions, time of prediction, geometry, material properties, and other model parameters can be different at test conditions than those for an anticipated application of a model. Situations for which the conditions may differ include those for which (1) one is in the design phase and a prototype of the system has not been constructed and tested under the anticipated conditions, (2) only one version of a final system can be built and destructive testing is not feasible, or (3) the anticipated design conditions are variable and one cannot easily reproduce the range of conditions with a limited number of carefully controlled experiments. Because data from these supporting experiments have value in model validation, even if the model was tested at different conditions than an anticipated application, methodology is required to evaluate the ability of the validation experiments to resolve the critical behavior for the anticipated application. The methodology presented uses models for the validation experiments and a model for the application to address how well the validation experiments resolve the application. More specifically, the methodology investigates the tradeoff that exists between the uncertainty (variability) in the behavior of the resolved critical variables for the anticipated application and the ability of the validation experiments to resolve this behavior. The important features of this approach are demonstrated through simple linear and non-linear heat conduction examples.

42 ENGINEERING↗

The SURE House (Solar Decathlon 2015)

Coastal towns and cities across the Northeastern US, with their high population density, aged utility infrastructure, and unique geography, are increasingly vulnerable to climate change related storm events. In October 2012 superstorm Sandy highlighted the fragility of our current coastal building types and made clear the need for a new model of design and construction which works to understand and mitigate these weaknesses. Dramatic changes in public policy, championed by both The Federal Emergency Management Agency (FEMA) and the National Flood Insurance Program (NFIP) are driving the rebuilding of these shore communities, often resulting in costly renovations, un-sustainable neighborhood configurations and in direct conflict with concurrent government policies such as The American with Disabilities Act (ADA). The SURE HOUSE demonstrates a series of new design solutions to these conflicting public policies and environmental imperatives. At Stevens Institute of Technology, the 2015 Solar Decathlon started with the challenge: Can we design a home for coastal New Jersey that dramatically reduces its energy use while protecting itself from the realities of a changing, more extreme climate? The SURE HOUSE merges the iconic 20th century shore home with 21st century building science. Utilizing innovative renewable energy technologies, a ‘Passive House’ level building envelope, and rugged glass-fiber-composite materials to flood-proof the home, the SURE HOUSE is a high-performance, net-zero-energy home, armored against extreme weather, designed for the contemporary lifestyle of the Jersey Shore and other vulnerable coastal communities. SUSTAINABLE At Stevens, we recognize that energy use in the home and workplace is directly connected to the growing problem of climate change. Reducing our energy consumption by designing higher performing, compact homes that are both functional, comfortable and desirable is the first critical step towards a modern, sustainable architecture for New Jersey and beyond. This is what informed the architectural design of the house. Configured about a compact form, thickly insulated and air-sealed walls eliminate thermal bridging and minimize energy losses while advanced glazing brings in free solar heat during the winter months. As a result of these passive design strategies, the SURE HOUSE has a greatly reduced carbon footprint requiring 91% less energy than a typical New Jersey home. Photovoltaic (PV) arrays on both the rooftop and operable shutters easily provide energy in excess of the home’s modest demands. The Stevens team considers a truly sustainable home in the era of climate change, one that prioritizes low energy use, and integrates right-sized renewable generation to supply the home’s needs. Low consumption, low production. RESILIENT In October of 2012, Hurricane Sandy wreaked havoc along the east coast of the US. In New Jersey alone there was an estimated 29.4 billion dollars in damages, 346,000 homes affected, and almost two and a half million people left without power, in some cases for over 10 days. Recovery from this storm and associated flooding is ongoing to this day, as many New Jersey homeowners grapple with the large costs of rebuilding and struggle to adapt to complicated new home building regulations. Damage from this storm to Hoboken, the home of the Stevens Institute of Technology’s campus, and to the New Jersey shore was extensive and many students on the SURE HOUSE team were directly affected by this historic event. The Stevens design team recognizes that in a world of more frequent and stronger storms, the ability to absorb and adapt to change is more important than ever. Successfully weathering the next storm and its aftermath is one of the primary goals in the design of the SURE HOUSE prototype. The SURE HOUSE introduces unique ‘dry flood-proofing’ methods to residential construction. Innovative wall and floor flood-proofing, utilizing durable composite sheathing materials adapted from the boating industry, were developed by the student team to render the SURE House’s building envelope flood proof up to the FEMA AE 6/7 Zone (+ 6/7 feet of water above sea-level). Designed and fabricated utilizing glass-fiber composite materials, the custom storm shutter system serves to protect the large glazed openings of the home from both air-borne debris impact and water infiltration during a storm event while also providing deterrence from the vandalism that often occurs in the aftermath of a calamitous event. During extended power outages, a ‘resilient’ solar array is capable of supplying critical amounts of energy and hot water to the home, without the use of battery storage or grid infrastructure. PV Description AC GRID-TIED PV SYSTEM The SURE HOUSE solar system consists of two distinct arrays, the grid-tied rooftop array which produces AC Powerand the shutter-mounted array which converts DC power generated by the modules directly into usable heat for the domestic hot water (DHW). The roof-mounted AC grid-tied array is comprised of three strings, two 11 module strings connected to an SMA SB 5000TL-US-223 inverter and a single 10 module string equipped and an SMA SB 3000TL-US-22 central inverter. All modules for the rooftop AC array are LG MonoX 2804 watt solar panels, chosen for their durability and efficiency. Inverter sizing and string size are optimized to the electrical characteristics of the chosen PV modules and the desired energy production, see Appendix 5B. The SURE HOUSE is projected to produce 12,353 kWh per year to meet 6,157 kWh per year of estimated consumption. Solar modules for the two AC grid-tied sub arrays are mounted on the main roof surface of the SURE HOUSE with a 10 degree tilt angle using a partially-ballasted polyethylene roof mounting system made by Renusol, which is particularly suited to the corrosive salt air of a coastal environment. This method was chosen for its installation simplicity and to limit detrimental roof penetrations. The 10 degree tilt optimizes the energy generated per roof area at a lower price, see Appendix 5A, and ensures that there is minimal wind uplift. DC SOLAR ELECTRIC DOMESTIC HOT WATER The SURE HOUSE’s approach to sustainable and resilient domestic hot water (DHW) consists of a unique, custom engineered DC solar electric hot water system. Employing the use of Advanced Energy’s DC electric PV heater (DCPVH)5 to heat domestic water well beyond the draw temperature, the SURE HOUSE is able to obtain a remarkably high solar fraction of 75% or more. The custom modified 80 gallon Vaughn DHW tank acts as a large solar ‘battery’ that stores heat energy in the form of hot water at almost 150 degrees, harvesting energy when the sun is out for use later in the day or overnight. The system, which uses electricity rather than heated fluid, is distinct from traditional ‘solar thermal’ systems by eliminating the dangers and associated maintenance issues of fluid based systems. By forgoing the use of external fluid loops, overheated solar collectors and pipes are not an issue for the SURE HOUSE system which never needs any yearly or seasonal flushing. In weather conditions where the integrated DCPVH unit cannot produce enough hot water via solar energy alone, the Vaughn hot water tank comes factory made with an AC powered 2.6 COP heat pump and a AC heating coil that serve as back-up heating elements. The DCPVH is powered by a DC array consisting of 10 custom-made Solbian by PVilion 180 watt, monocrystalline, flexible solar modules6. The Solbian modules are directly mounted to the top half of the operable storm shutters on the south façade of the SURE HOUSE. The SURE HOUSE team worked closely with PVillion, a PV system designer specializing in flexible architectural photovoltaics, to design an adhesive system that works with the glass-fiber storm shutter surface in a reliable manner over an extended period. Because this system operates in DC-only mode and never connects to the municipal power grid, the system can continue to create hot water safely and effectively even during grid disruption events. This hot water, and the energy stored within it, could be used for a range of activities including washing and cooking to more elaborate hydronic heating systems as desired. See Appendix 6 for system engineering, sizing and modeling.

14 SOLAR ENERGY↗

Nonadiabatic Flamelet Formulation for Predicting Wall Heat Transfer in Rocket Engines

A flamelet-based combustion model is introduced for the prediction of wall heat transfer in rocket engines and confined combustion systems. To account for convective heat loss due to the interaction of the flame with the wall, a permeable thermal boundary condition is introduced in the counterflow diffusion flame configuration. The solution of the resulting nonadiabatic flame structure forms a three-dimensional manifold, which is parameterized in terms of mixture fraction, progress variable, and temperature. The performance of the model is first assessed through a direct numerical simulation analysis of an H 2 /O 2 diffusion flame that is stabilized at an inert isothermal wall. The developed nonadiabatic flamelet model is shown to accurately predict the temperature, chemical composition, and wall heat transfer. Combined with a presumed probability density function closure, the model is then applied to large-eddy simulation of a single-injector rocket combustor to examine effects of heat transfer on the turbulent flame structure in rocket engines.

42 ENGINEERING↗

Clean and Efficient Diesel Engine

Task 1 was to design study for fuel-efficient system configuration. The objective of task 1 was to perform a system design study of locomotive engine configurations leading to a 5% improvement in fuel efficiency. Modeling studies were conducted in GT-Power to perform this task. GT-Power is an engine simulation tool that facilitates modeling of engine components and their system level interactions. It provides the capability to evaluate a variety of engine technologies such as exhaust gas circulation (EGR), variable valve timing, and advanced turbo charging. The setup of GT-Power includes a flexible format that allows the effects of variations in available technologies (i.e., varying EGR fractions or fuel injection timing) to be systematically evaluated. Therefore, development can be driven by the simultaneous evaluation of several technology configurations.

33 ADVANCED PROPULSION SYSTEMS↗

Breaking Parallel Orientation of Rods via a Dendritic Architecture toward Diverse Supramolecular Structures

Abstract Self‐assembled nanostructures of rod‐like molecules are commonly limited to nematic or layered smectic structures dominated by the parallel arrangement of the rod‐like components. Distinct self‐assembly behavior of four categories of dendritic rods constructed by placing a tri(hydroxy) group at the apex of dendritic oligo‐fluorenes is observed. Designed hydrogen bonding and dendritic architecture break the parallel arrangement of the rods, resulting in molecules with specific (fan‐like or cone‐like) shapes. While the fan‐shaped molecules tend to form hexagonal packing cylindrical phases, the cone‐shaped molecules could form spherical motifs to pack into various ordered structures, including the Frank–Kasper A15 phase and dodecagonal quasicrystal. This study provides a model system to engineer diverse supramolecular structures by rod‐like molecules and sheds new light into the mechanisms of the formation of unconventional spherical packing structures in soft matter.

Zhang, Ruimeng↗