Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy systems integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Recharge Demand Mitigation for Latent Heat Thermal Energy Storage at Off-peak Hours

The utilization of integrated heat pump thermal energy storage (HP-TES) systems for space conditioning applications can reduce electrical power demand and achieve utility savings resulting from peak shaving and load shifting. However, issues arise when the energy required to recharge the TES exceeds the shifted energy demand, especially in extreme climates where high-temperature lifts between the outdoor air conditions and phase-change materials (PCMs) during recharging may occur. In this work, a single room-temperature (22°C) PCM-TES is integrated into a single-speed heat pump system using a secondary hydronic loop where the TES is recharged using the outdoor unit during off-peak hours. Three recharge strategies were investigated as potential pathways to reduce recharging power demand: (i) considering different heat source/sink temperatures, (ii) using a variable-speed compressor, and (iii) using a variable-speed pump. Simulations were conducted using Modelica for HP-TES recharging at different heat source/sink temperatures from -30 – 20℃ in heating mode and 0 – 30℃ in cooling mode. Results show that the most effective recharge demand reduction strategy is an HP-TES system using a single-speed compressor with a variable-speed pump for the hydronic loop run at preferable heat source/sink temperatures when the temperature lifts were reduced. Utilizing a variable-speed compressor for the HP-TES system reduced recharge time in extreme cases at the cost of additional compressor power input. The findings motivate potential control strategies that minimize recharge energy and maximize peak energy savings, hence reducing overall operating costs and annual energy consumption for HP-TES systems for space conditioning applications.

25 ENERGY STORAGE↗

Sandia's Integrated Methodology for Energy and Infrastructure Resilience Analysis

Sandia National Laboratories' (Sandia) Resilient Energy Systems (RES) Strategic Initiative is establishing a strategic vision for U.S. energy systems' resilience through threat-informed research and development, enabling energy and interdependent infrastructure systems to successfully adapt in an environment of accelerating change. A key challenge in promoting energy systems resilience lies in developing rigorous resilience analysis methodologies to quantify system performance. Resilience analysis methodologies should enable evaluation of the consequences of various disruptions and the relative effectiveness of potential mitigations. To address this challenge, RES synthesized the common components of Sandia's resilience frameworks into an integrated methodology for energy and infrastructure resilience analysis. This report documents, demonstrates, and extends this methodology.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dynamic Facade Dashboard v0.1.0

The dashboard is a useful tool for early-stage building design decision-making and communication, as it can help users quickly compare the energy and non-energy related performance of various automated, integrated facade systems using a library of pre-computed data. Users can explore the impacts of various design choices by selecting different facade glazing and shading systems, facade control strategies, and lighting control strategies across multiple climate zones. The dashboard instantly visualizes key metrics, including energy usage in HVAC and lighting, peak cooling and heating load, and daylight availability, allowing immediate trade-off analysis to optimize building efficiency and comfort.

Yu, Tammie [Lawrence Berkeley National Laboratory ↗

Enhancing heat pump water heater performance with embedded phase change materials thermal energy storage: First hour rating improvement and demand response operation

The increasing global emphasis on energy efficiency and sustainability has put heat pump water heaters (HPWHs) in the spotlight as an energy-efficient alternative to traditional water heating systems. However, their widespread adoption is limited by challenges such as insufficient First Hour Rating (FHR), suboptimal control mechanisms, and limited flexibility for demand response operations. Here, to address these limitations, this study proposes an innovative HPWH system integrated with embedded phase change material (PCM)-based thermal energy storage (TES). The research introduces a novel design and control strategy that leverages optimized PCM integration to enhance thermal storage capacity, improve hot water delivery during peak demand, and increase load-shifting potential. A combination of system modeling, performance simulation, and demand response control strategy evaluation was employed to quantify the benefits of PCM integration. Results demonstrate that the proposed PCM-TES HPWH system significantly enhances FHR, with an optimal 7.0 lb. of PCM increasing FHR by over 26 %—from 62 to 78 gal—for a standard 50-gal HPWH. Additionally, under advanced demand response operation using a preheat strategy, the system reduces the percentage of control temperature out-of-band time from 65 % (conventional HPWH) to just 11.6 %, enabling a more stable and efficient hot water supply. This research contributes a novel PCM-embedded HPWH design and control framework that addresses both performance and grid-interactivity challenges. The findings offer a viable pathway to enhancing the operational efficiency, flexibility, and grid responsiveness of residential water heating systems.

Demand response control↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

Island Power Systems With High Levels of Inverter-Based Resources: Stability and Reliability Challenges

As many island power systems seek to integrate high levels of renewable energy, they face new challenges on top of the existing difficulties of operating an isolated grid. With their drastically declining cost, variable renewables, such as wind and photovoltaics (PVs), are increasingly being integrated into island grids to reduce the use of imported fuels. These deployments of renewable energy are dominated by PV and wind generators, which bring unique challenges of their own. While the integration issues span numerous timescales (from microseconds to many months), this article focuses on reliability and stability challenges on short timescales (microseconds to seconds). In other words, we seek to answer (to the extent that it is currently known) how to ensure the frequency and voltage stability in an island power system with very high instantaneous levels of wind and PVs. And because island power systems are often among the first to reach these very high instantaneous levels of wind and PV generation, we note that they are forging a path for larger interconnected power systems to follow.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A 1kV, 480V Power Electronics Hub for DER Integration in Commercial Buildings

Power electronic (PE) systems are increasingly being integrated into distribution and sub-distribution networks in support of distributed energy resource integration (DERs), electric vehicle (EV) charging (particularly in the case of fast charging infrastructure), and improvement in power quality for high performance computing and/or servers farms. This provides an opportunity to research and develop integrated PE systems that can function as single systems thereby bringing additional functionality and benefits to the overall system. The goal of this paper is to demonstrate foundational technologies and capabilities for a multiport power electronics energy hub that can intelligently coordinate and control integrated sources and loads. The focus for this digest is on a commercial building use case which is demonstrated in hardware.

Starke, Michael↗

Probabilistic Look-ahead Contingency Analysis Integration with Commercial Tool and Practical Data

This paper presents an initial effort of integrating a smart sampling-based probabilistic look-ahead contingency analysis algorithm with General Electric (GE) Grid Solutions’ commercial energy management system (EMS) tool as a proof-of-concept for a seamless research tool integration using real world large-scale grid data. With the increasing impact of random forces such as variable generation and load, their stochastic behaviors cannot be ignored. However, the current practices are still dominated by deterministic tools. They are becoming increasingly inadequate for the future grid. The developed look-ahead contingency analysis algorithm incorporates forecast errors of variable energy and load to address the challenges brought by the increasing uncertainty of power system. The algorithm can reveal the potential violations caused by the variance of variable energy and load that are not normally detected by traditional deterministic approaches. To test its performance under practical environments ( real data with real commercial tool), significant efforts have been made to prepare test cases, modify GE EMS tool, and adapt an extreme value distribution algorithm to analyze the GE EMS’s violation-only outputs. The test results clearly demonstrate the effectiveness of the developed algorithm as new transformer violations that were not previously detected have been identified. This performance provides better situational awareness to engineers for their decision-making process under uncertainty. Moreover, with the discussion of computational performance and future work, this paper has shown a clear path for integrating the probabilistic algorithm with commercial tools to make us better equipped for the changing power system.

Modeling and simulation of power systems, constrai↗

Modeling and Impact of Hyperloop Technology on the Electricity Grid

This paper provides an overview of hyperloop technologies, including a brief discussion of key components of a hyperloop system that determine the electric power requirements as a function of time. At-scale hyperloop systems do not yet exist, so a model was used to generate a set of load profiles for conceptual hyperloop realizations at four locations in the United States: two systems in California and one each in Colorado and Ohio. In all four cases, the modeled hyperloop load profiles included pulses in both active and reactive power. Grid modeling was performed to estimate the grid impacts and for dis-cussing grid integration challenges. The paper discusses how energy storage systems might be used to eliminate the pulsating load characteristics or significantly reduce it to accommodate current grid planning guidelines

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Optimal Design of a Desalination System Integrated Between a Glass-Covered Solar Collection Water Chamber and a Heat Dissipating Chimney

Abstract Solar thermal energy is trapped in a glass-covered water chamber/basin to provide the heat for evaporation of brackish water in a novel desalination system. To harvest clean water, a chimney is integrated with the water basin, which draws air into the chamber to be humidified by the vapor and then being ventilated via buoyance force. Uniquely, thermal conductive metal sheet is recommended to make the chimney, which allows the vapor in the humid air condenses easily when flowing up. The condensate at the inner wall of the chimney flows down to be collected as clean water. Mathematical modeling and numerical computation have been carried out to delineate the coupling of the buoyance-force-driven flow with the heat and mass transfer of air and water in the solar collection chamber and the condensation of vapor in the heat-dissipating chimney. The objective of the simulation and optimization of the system is to find the best match of the dimensions of the water chamber with a chimney to maximize the production of clean water and energy efficiency. The model has been used to simulation several cases (of water from 40 °C to 50 °C) with available experimental data from the authors’ previous work, and the agreement was satisfactory. The optimization studies found that there is a maximum air flowrate corresponding to a critical chimney height due to the requirement that the chimney is designated to dissipate heat as much as possible to condense water vapor. With the chimney height greater than the critical height, the airflow rate will have a slight decrease. Nevertheless, higher than a critical height is still needed for a chimney to condense more moisture. Optimized chamber diameters at different chimney heights are provided for reference of optimal system designs.

Engineering↗

Scheduler Modeling of Distributed Energy Resources for Providing Ancillary Services

Distribution energy resources (DERs) have been integral components of modern power systems, and their capability to provide grid services has been widely studied. To promote the deployment of these resources in providing grid services in real-world utility operations, this paper proposes a day-ahead scheduler model for a distribution system connected DER plant. A certain amount of generation capacity of this DER plant is reserved for frequency services, and some ancillary services for the distribution system-including peak load reduction, voltage regulation, and power factor control-are integrated into the model. The model is tested on a real-world distribution system. From the simulation results, the energy and reserve schedule of the solar photovoltaic (PV) unit and battery energy storage system (BESS) can be determined, and voltage and power factor are well maintained. Additionally, in order to demonstrate the specific characteristics of the co-located and hybrid operation modes for the PV and BESS, these two modes are analyzed both theoretically and through real-time simulation. Simulation results show that most of PV's variability is transferred to the net power in the co-located mode, whereas it is transferred to the BESS in the hybrid mode. This proposed scheduler model and the comparison of co-located and hybrid modes can provide practical guidance for the applications of DER plant in the real-world utility.

14 SOLAR ENERGY↗

Exploring the Future of Mobility: Transportation Energy and Mobility Pathway Options (TEMPO) Model

The Transportation Energy and Mobility Pathway Options (TEMPO) modeling framework is intended to generate future pathways to achieve system-level goals, estimate implications of different scenarios and decisions, estimate affordability and infrastructure use impacts, assess energy use and emissions implications, inform decision makers, and assess integration opportunities between transportation and energy infrastructure and supply systems.

ADVANCED PROPULSION SYSTEMS↗

Secure Communications Concept and API Concept for Integrating XENDEE Positronix with TESLA PowerPack System at Site 300 (Final Deliverable)

The CleanStart DERMS project focuses on the management of Distributed Energy Resources (DER) for enhanced distribution grid resilience. The demonstration site has changed from Riverside Public Utility to the LLNS Site 300 DERS demonstration site. This project has so far focused only on device level controllers and local area controllers. These controllers potentially lack the ability to perform supervisory control and grid interactive control functions, essential for grid-level optimal DER management. This project seeks to close that gap in development of secure communication concept and appropriate Application Programming Interfaces (API) to enable integration with DERs, device level and local area controllers, such as Distributed Energy Resources Management System (DERMS).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

DEEP Solar: Data DrivEn Modeling and Analytics for Enhanced System Layer ImPlementation

Realizing the SETO 2030 mission of reducing solar energy costs to 3-5 c/kWh will require innovative enabling research on effective, cost-efficient integration of local PV within distribution systems. However, the intermittent and variable nature of PVs compels operators to impose conservative hosting capacity constraints. Given the extremely high variability of (intermittent and unpredictable) solar energy generation, relaxing the capacity constraints (which are currently around 15%) and achieving 100% or greater integration of renewables will require a fundamental transformation of the power grid via the utilization of exponentially larger amounts of AMI enabled fine-grained data. To address the challenges in increasing the penetration of renewable energy based DERs, this project envisions an Enhanced System Layer (ESL) at the distribution network level that is reliable, cost-effective and scalable to millions of Distributed Energy Resources (DERs)/devices. This includes developing: 1) Transformative and highly scalable machine learning based predictive analytics tools that plug into distribution system planning and provide real-time situational awareness at the distribution level for short and long-term operational planning. The tools will be built using novel data-driven energy models of millions of active nodes with AMI, 2) Adaptive stochastic analysis and optimization algorithms for real-time grid operations, 3) Dynamic Scenario Analysis using parallel Cloudenabled implementations with < 1 minute computational cycle times.

14 SOLAR ENERGY↗

A Review of Machine Learning Applications in Power System Resilience

The integration of power electronics enabled devices and the high penetration of renewable energy drastically increase the complexity of power system operation and control. Power systems are still vulnerable to large-scale blackouts caused by extreme natural events or man-made attacks. With the recent development in artificial intelligence technique, machine learning has shown a processing ability in computational, perceptual and cognitive intelligence. It is an urgent challenge to integrate the advanced machine learning technology and large amount of real-time data from wide area measurement systems and intelligent electronic devices, in order to effectively enhance power system resilience and ensure the reliable and secure operation of power systems. Therefore, this paper aims to systematically review the existing application of machine learning methods on power system resilience enhancement, to expand the interest of researchers and scholars in this topic, and to jointly promote the application of artificial intelligence in the field of power systems.

Deep Learning↗

Integrated rectifier-generator system for AC-to-DC conversion

This disclosure relates AC-to-DC rectification and power flow control of electrical power generators. An integrated rectifier-generator AC-DC conversion circuit and system are disclosed for providing a regulated DC output. The integrated rectifier-generator AC-DC conversion circuit and system may include serially stacked passive and active rectifiers connected to multiple AC ports of an electrical power generator driven by mechanical energy captured by an energy harvester. The integrated rectifier-generator AC-DC conversion circuit and system may be configured to perform active ripple control and a maximum power tracking from the energy harvester by controlling a fraction of an overall power that flow through the active rectifier.

Huynh, Phuc Thanh↗