Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Techniques and tactics used in determining the structure of the trimeric ebolavirus glycoprotein

Here, the techniques, tactics and strategies used to overcome a series of technical roadblocks in crystallization and phasing of the trimeric ebolavirus glycoprotein are described. The trimeric membrane-anchored ebolavirus envelope glycoprotein (GP) is responsible for viral attachment, fusion and entry. Knowledge of its structure is important both for understanding ebolavirus entry and for the development of medical interventions. Crystal structures of viral glycoproteins, especially those in their metastable prefusion oligomeric states, can be difficult to achieve given the challenges in production, purification, crystallization and diffraction that are inherent in the heavily glycosylated flexible nature of these types of proteins. The crystal structure of ebolavirus GP in its trimeric prefusion conformation in complex with a human antibody derived from a survivor of the 1995 Kikwit outbreak has now been determined [Lee et al. (2008 ▶), Nature (London), 454, 177–182]. Here, the techniques, tactics and strategies used to overcome a series of technical roadblocks in crystallization and phasing are described. Glycoproteins were produced in human embryonic kidney 293T cells, which allowed rapid screening of constructs and expression of protein in milligram quantities. Complexes of GP with an antibody fragment (Fab) promoted crystallization and a series of deglycosylation strategies, including sugar mutants, enzymatic deglycosylation, insect-cell expression and glycan anabolic pathway inhibitors, were attempted to improve the weakly diffracting glycoprotein crystals. The signal-to-noise ratio of the search model for molecular replacement was improved by determining the structure of the uncomplexed Fab. Phase combination with Fab model phases and a selenium anomalous signal, followed by NCS-averaged density modification, resulted in a clear interpretable electron-density map. Model building was assisted by the use of B-value-sharpened electron-density maps and the proper sequence register was confirmed by building alternate sequences using N-linked glycan sites as anchors and secondary-structural predictions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Technical note: Optimization for improved tube-loading efficiency in the dual-energy computed tomography coupled with balanced filter method

Purpose: This article describes the spectral optimization of dual-energy computed tomography using balanced filters (bf-DECT) to reduce the tube loadings and dose by dedicating to the acquisition of electron density information, which is essential for treatment planning in radiotherapy. Methods: For the spectral optimization of bf-DECT, the author calculated the beam-hardening error and air kerma required to achieve a desired noise level in an electron density image of a 50-cm-diameter cylindrical water phantom. The calculation enables the selection of beam parameters such as tube voltage, balanced filter material, and its thickness. Results: The optimal combination of tube voltages was 80 kV/140 kV in conjunction with Tb/Hf and Bi/Mo filter pairs; this combination agrees with that obtained in a previous study [M. Saito, ''Spectral optimization for measuring electron density by the dual-energy computed tomography coupled with balanced filter method,'' Med. Phys. 36, 3631-3642 (2009)], although the thicknesses of the filters that yielded a minimum tube output were slightly different from those obtained in the previous study. The resultant tube loading of a low-energy scan of the present bf-DECT significantly decreased from 57.5 to 4.5 times that of a high-energy scan for conventional DECT. Furthermore, the air kerma of bf-DECT could be reduced to less than that of conventional DECT, while obtaining the same figure of merit for the measurement of electron density and effective atomic number. Conclusions: The tube-loading and dose efficiencies of bf-DECT were considerably improved by sacrificing the quality of the noise level in the images of effective atomic number.

60 APPLIED LIFE SCIENCES↗

Direct ion flux measurements at high-pressure-depletion conditions for microcrystalline silicon deposition

The contribution of ions to the growth of microcrystalline silicon thin films has been investigated in the well-known high-pressure-depletion (HPD) regime by coupling thin-film analysis with plasma studies. The ion flux, measured by means of a capacitive probe, has been studied in two regimes, i.e., the amorphous-to-microcrystalline transition regime and a low-to-high power regime; the latter regime had been investigated to evaluate the impact of the plasma power on the ion flux in collisional plasmas. The ion flux was found not to change considerably under the conditions where the deposited material undergoes a transition from the amorphous to the microcrystalline silicon phase; for solar-grade material, an ion-to-Si deposition flux of ∼0.30 has been determined. As an upper-estimation of the ion energy, a mean ion energy of ∼19 eV has been measured under low-pressure conditions (<1 mbar) by means of a retarding field energy analyzer. Combining this upper-estimate with an ion per deposited Si atom ratio of ∼0.30, it is concluded that less than 6 eV is available per deposited Si atom. The addition of a small amount of SiH{sub 4} to an H{sub 2} plasma resulted in an increase of the ion flux by about 30% for higher power values, whereas the electron density, deduced from optical emission spectroscopy analysis, decreased. The electron temperature, also deduced from optical emission spectroscopy analysis, reveals a slight decrease with power. Although the dominant ion in the HPD regime is SiH{sub 3}{sup +}, i.e., a change from H{sub 3}{sup +} in pure hydrogen HPD conditions, the measured larger ion loss can be explained by assuming steeper electron density profiles. These results, therefore, confirm the results reported so far: the ion-to-Si deposition flux is relatively large but has neither influence on the microcrystalline silicon film properties nor on the phase transition. Possible explanations are the reported high atomic hydrogen to deposition flux ratio, mitigating the detrimental effects of an excessive ion flux.

36 MATERIALS SCIENCE↗

Time-resolved and multiple-angle Thomson scattering on gas-puff Z-Pinch plasmas at pinch time

A 526.5 nm Thomson scattering diagnostic laser enables probing of the plasma conditions of neon gas-puff z-pinch implosions with temporal resolution. Splitting the laser into two 2.5 J pulses, both 2.3 ns in duration and separated by 4 ns, allows observation of sub-nanosecond time-resolved spectra for a total time of 7 ns. Collection optics were set at 90° and 30° to the laser, observing the same on-axis scattering volume with a radial extent of 0.4 mm. The spectra from both angles were collected by using the same streak camera, using a coupling system that allowed us to obtain temporal, spectral, and angular resolution in the same image. By comparing the ion-acoustic spectra from the two angles, we determined electron temperature and a range of possible electron densities. Measurements made in the 1-3 ns period before pinch time show best fit (determined by a least-squares method) electron densities of around 2 × 10 19 cm -3 , increasing to 1.5 × 10 20 cm -3 in the 3 ns following the start of the x-ray burst (t = 0 ns) from the pinch. The electron temperature increases from 300 eV to 500 eV at t = 0 ns before decreasing to below 300 eV after pinch time. With the present parameters (probe beam, collection angles, and electron temperature and density), this diagnostic method is too insensitive to electron density to provide more than a constraint on that parameter. Plasma regimes in which this technique could determine electron density with some precision are calculated.

47 OTHER INSTRUMENTATION↗

A global model of the self-pulsing regime of micro-hollow cathode discharges

A global (volume-averaged) model of the self-pulsing regime of micro-hollow cathode discharges working in argon gas is proposed. The power balance is done using an equivalent circuit model of the discharge that allows the current and voltage dynamics to be calculated. The fraction of the total power dissipated in the discharge that contributes to electron heating is deduced from a sheath model previously described. The particle balance is first done in a very simplified reaction scheme involving only electrons, argon atomic ions, and argon molecular ions. In a second step, the excited states (the metastable state Ar*({sup 3}P{sub 2}) and the resonant state Ar*({sup 3}P{sub 1})) are included in the particle balance equations. The models are compared to experiments and several conclusions are drawn. The model without excited states underestimates the electron density and does not capture well the trends in pressure. The model with the excited states is in better agreement which shows that multi-step ionization plays a significant role. The time-evolution of the electron density follows closely that of the discharge current but the excited states density presents two peaks: (i) the first at the early stage of the current peak due to direct excitation with high electron temperature, (ii) the second at the end of the current (and electron density) peak due to large production of excited states by electron-ion recombination at very low electron temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tracing Actin Filament Bundles in Three-Dimensional Electron Tomography Density Maps of Hair Cell Stereocilia

Cryo-electron tomography (cryo-ET) is a powerful method of visualizing the three-dimensional organization of supramolecular complexes, such as the cytoskeleton, in their native cell and tissue contexts. Due to its minimal electron dose and reconstruction artifacts arising from the missing wedge during data collection, cryo-ET typically results in noisy density maps that display anisotropic XY versus Z resolution. Molecular crowding further exacerbates the challenge of automatically detecting supramolecular complexes, such as the actin bundle in hair cell stereocilia. Stereocilia are pivotal to the mechanoelectrical transduction process in inner ear sensory epithelial hair cells. Given the complexity and dense arrangement of actin bundles, traditional approaches to filament detection and tracing have failed in these cases. In this study, we introduce BundleTrac, an effective method to trace hundreds of filaments in a bundle. A comparison between BundleTrac and manually tracing the actin filaments in a stereocilium showed that BundleTrac accurately built 326 of 330 filaments (98.8%), with an overall cross-distance of 1.3 voxels for the 330 filaments. BundleTrac is an effective semi-automatic modeling approach in which a seed point is provided for each filament and the rest of the filament is computationally identified. We also demonstrate the potential of a denoising method that uses a polynomial regression to address the resolution and high-noise anisotropic environment of the density map.

stereocilia↗

Mode transition in CF{sub 4} + Ar inductively coupled plasma

The E to H mode transitions are studied by a hairpin probe and optical emission spectroscopy in inductively coupled CF{sub 4} + Ar plasmas. Electron density, optical emission intensity of Ar, and the voltage and current are measured during the E to H mode transitions. It is found that the electron density and plasma emission intensity increase continuously at low pressure during the E to H mode transition, while they jump up discontinuously at high pressure. Meanwhile, the transition threshold power and △P (the power interval between E and H mode) increase by increasing the pressure. When the ratio of CF{sub 4} increases, the E to H mode transition happens at higher applied power, and meanwhile, the △P also significantly increases. Besides, the effects of CF{sub 4} gas ratio on the plasma properties and the circuit electrical properties in both pure E and H modes were also investigated. The electron density and plasma emission intensity both decrease upon increasing the ratio of CF{sub 4} at the two modes, due to the stronger electrons loss scheme. The applied voltages at E and H modes both increase as increasing the CF{sub 4} gas ratio, however the applied current at two modes behave just oppositely with the gas ratio.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Primordial helium and the cosmic background radiation

The products of primordial nucleosynthesis, along with the cosmic microwave background (CMB) photons, are relics from the early evolution of the Universe whose observations probe the standard model of cosmology and provide windows on new physics beyond the standard models of cosmology and of particle physics. According to the standard, hot big bang cosmology, long before any stars have formed a significant fraction ( ∼ 25%) of the baryonic mass in the Universe should be in the form of helium-4 nuclei. Since current observations of {sup 4}He are restricted to low redshift regions where stellar nucleosynthesis has occurred, an observation of high redshift, prestellar, truly primordial {sup 4}He would constitute a fundamental test of the hot, big bang cosmology. At recombination, long after big bang nucleosynthesis (BBN) has ended, the temperature anisotropy spectrum imprinted on the CMB depends on the {sup 4}He abundance through its connection to the electron density and the effect of the electron density on Silk damping. Since the relic abundance of {sup 4}He is relatively insensitive to the universal density of baryons, but is sensitive to a non-standard, early Universe expansion rate, the primordial mass fraction of {sup 4}He, Yp, offers a test of the consistency of the standard models of BBN and the CMB and, provides constraints on non-standard physics. Here, the WMAP seven year data (supplemented by other CMB experiments), which lead to an indirect determination of Yp at high redshift, are compared to the BBN predictions and to the independent, direct observations of {sup 4}He in low redshift, extragalactic HII regions. At present, given the very large uncertainties in the CMB-determined primordial {sup 4}He abundance (as well as for the helium abundances inferred from HII region observations), any differences between the BBN predictions and the CMB observations are small, at a level ∼<1.5σ.

79 ASTRONOMY AND ASTROPHYSICS↗

Partial-reflection studies of D-region winter variability

D-region electron densities were measured from December, 1972, to July, 1973, at Urbana, Illinois (latitude 40.2N) using the partial-reflection technique. During the winter, electron densities at altitudes of 72, 76.5, and 81 km show cyclical changes with a period of about 5 days that are highly correlated between these altitudes, suggesting that the mechanism responsible for the winter anomaly in D-region ionization applies throughout this height region. From January 13 to February 3, a pronounced wave-like variation occurred in the partial-reflection measurements, apparently associated with a major stratospheric warming that developed in that period. During the same time period, a traveling periodic variation is observed in the 10-mb height; it is highly correlated with the partial-reflection measurements. Electron density enhancements occur approximately at the same time as increases in the 10-mb height. Comparison of AL and A3 absorption measurements with electron density measurements below 82 km indicates that the winter anomaly in D-region ionization is divided into two types. Type 1, above about 82 km, extends horizontally for about 200 km while type 2, below about 82 km, extends for a horizontal scale of at least 1000 km.

Denny, B. W.↗

Operational domain of Proto-MPEX

The Prototype-Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device to test the plasma source concepts for the future Material Plasma Exposure eXperiment (MPEX). MPEX is planned to address plasma material interactions under fusion reactor divertor conditions as will occur in devices like DEMO, including the plasma exposure of a-priori neutron irradiated materials. This requires a novel linear plasma device with a plasma source that can produce high electron densities along with heating systems to obtain high electron and ion temperatures. In Proto-MPEX a high-power helicon source was tested together with electron heating (28 GHz microwaves) and ion cyclotron heating (8.5-12 MHz). Electron densities in excess of 1 × 1020 m-3 were produced with the helicon antenna. Electron temperatures can reach 20 eV and are typically below 6 eV at high densities (>5 × 1019 m-3). Ion heating has been demonstrated at low electron densities (<2 × 1019 m-3) with ion temperatures of up to 13 eV. Maximum heat fluxes of 14 MW/m2 have been obtained in low density discharges (~5 × 1018 m-3), while heat fluxes are typically only 2–3 MW/m2 in high density discharges (>2 × 1019 m-3).

Rapp, Juergen↗

Deconvolution of Stark broadened spectra for multi-point density measurements in a flow Z-pinch

Stark broadened emission spectra, once separated from other broadening effects, provide a convenient non-perturbing means of making plasma density measurements. A deconvolution technique has been developed to measure plasma densities in the ZaP flow Z-pinch experiment. The ZaP experiment uses sheared flow to mitigate MHD instabilities. The pinches exhibit Stark broadened emission spectra, which are captured at 20 locations using a multi-chord spectroscopic system. Spectra that are time- and chord-integrated are well approximated by a Voigt function. The proposed method simultaneously resolves plasma electron density and ion temperature by deconvolving the spectral Voigt profile into constituent functions: a Gaussian function associated with instrument effects and Doppler broadening by temperature; and a Lorentzian function associated with Stark broadening by electron density. The method uses analytic Fourier transforms of the constituent functions to fit the Voigt profile in the Fourier domain. The method is discussed and compared to a basic least-squares fit. The Fourier transform fitting routine requires fewer fitting parameters and shows promise in being less susceptible to instrumental noise and to contamination from neighboring spectral lines. The method is evaluated and tested using simulated lines and is applied to experimental data for the 229.69 nm C III line from multiple chords to determine plasma density and temperature across the diameter of the pinch. These measurements are used to gain a better understanding of Z-pinch equilibria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A comparative topological study of different metal-metal and metal-ligand interactions in polynuclear organometallic clusters

The existence and characterization of a bond between the Zn atoms in the recently synthesized complex [Zn{sub 2}(η{sup 5}−C{sub 5}Me{sub 5}){sub 2}] (I), as well as between two of the three Ru atoms in [Ru{sub 3}(μ−H){sub 2}(μ{sub 3}−MeImCH)(CO{sub 9}] (Me{sub 2}Im = 1,3-dimethylimidazolin-2-ylidene) (II), are firmly based on low temperature X-ray synchrotron diffraction experiments. The multipolar refinement of the experimental electron densities and their topological analyses by means of the Atoms in Molecules (AIM) theory reveal the details of the Zn-Zn and Ru-Ru bonds, such as their open-shell intermediate character. The results are consistent with a typical metal-metal single σ bond for the former, whereas a delocalized kind of bond involving 5c-6e is present in the latter. In addition, experimental results are compared with theoretical ab initio calculations of the DFT (density functional theory) and MP2 (Mo/ller-Plesset perturbation theory) electron densities, giving a coherent view of the bonding in both complexes. Many other topological properties of both compounds are also studied, in particular the different metal-ligand interactions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bent paths of a positive streamer and a cathode-directed spark leader in diffuse discharges preionized by runaway electrons

Diffuse discharges preionized by runaway electrons can produce large-area homogeneous discharges at elevated pressures, which is an intriguing phenomenon in the physics of pulsed discharges. In this paper, runaway-electron-preionized diffuse discharge (REP DD) was obtained in a wide pressure range (0.05–0.25 MPa), and under certain conditions a positive streamer and a cathode-directed spark leader could be observed to propagate at some angles to the applied (background) electric field lines. For a 16-mm gap at an air pressure of 0.08–0.1 MPa, the percentage of pulses in which such propagation is observed is about 5%–50% of their total number, and in the other pulses such bent paths could not be observed because there is even no streamer or cathode-directed spark leader in diffuse discharges. In our opinion, such propagation of the positive streamer and the cathode-directed spark leader at some angle to the background electric field lines owes to different increase rates of the electron density in different regions of the discharge volume under REP DD conditions. Therefore, during the formation of a REP DD, the increase of the electron density is inhomogeneous and nonsimultaneous, resulting in an electron density gradient at the ionization wave front.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Range, resolution and power of THz systems for remote detection of concealed radioactive materials

This paper analyzes parameters required for realizing remote detection of a concealed source of ionizing radiation by observing the occurrence of breakdown in air by a focused wave beam. Production of free electrons and the free electron density in the absence/presence of additional sources of ionization are analyzed. The maximum electron density in the discharge and the time required for this density to return after the discharge back to its stationary level, are estimated. The optimal excess of the power density and the corresponding power level as the function of frequency are determined. It is shown that the optimal frequency of such systems ranges from 0.3 up to 0.8 THz. The paper also determines the range of such systems as the function of the source frequency and power and contains a brief analysis of available sources of microwave, millimeter-wave and THz radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test particle simulation of the role of ballistic electrons in hybrid dc/rf capacitively coupled plasmas in argon

Hybrid dc/rf plasma sources are an emerging equipment technology in plasma etching for semiconductor manufacturing. In this work, test particle simulations are used to describe the nature and role of the ballistic electrons, which originate as secondary electrons on a dc/rf (i.e., VHF, 60 MHz) biased upper electrode and are then accelerated in the sheath toward the opposite non-dc biased lower electrode. This opposite electrode, on which a wafer is placed, may have rf bias power applied to it at low frequencies. 2 MHz is typical. While a hybrid dc/rf plasma source is sustained by the VHF power source, simulations reveal ballistic electrons assist in the production of a plasma characterized by a relatively high ionization rate constant, especially in the dc sheath. The dc source helps to provide a source of high energy electrons that may reach the wafer. However, when the rf bias is applied on the lower electrode, ballistic electrons are confined in the potential well formed between electrodes and easily thermalized in the bulk. The simulated electron density dependencies on the dc bias and lower electrode rf power describe a dual mode source and are consistent with measured data. When no rf power is applied on the electrode opposite to the dc power source, the bulk electron density drops with increasing dc power at constant VHF power; when rf power is applied to the electrode opposite to the dc power source, the bulk electron density increases with dc power at constant VHF power. The fraction of electrons significantly above thermal reaching the wafer is much higher when no rf power is applied at the lower electrode but the total flux lower. Depending on its level, rf power applied to the wafer may effectively suppress the number of ballistic electrons that reach the wafer. Finally, the ionization rate constant due to ballistic electrons can be fitted as a simple function of the electric field in the dc sheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Orientation dependence of relativistic-positron annihilation in single crystals

An effect of the orientation dependence of the cross section for the single-photon annihilation of relativistic positrons with atomic electrons in a crystal is predicted. It is shown that the probability for the single-photon annihilation of a channeled positron in a crystal may be either suppressed in a crystal in relation to a homogeneous medium or, on the contrary, enhanced. The reason is that, depending on their incidence angle, the positrons may be either in the vicinity of ion planes of the crystal, where the electron density is higher, or far away from them, where the electron density is lower.

74 ATOMIC AND MOLECULAR PHYSICS↗

Application of Anomalous Diffraction Methods to the Study of DNA and DNA-Complexes

Anomalous scattering is commonly used to solve X-ray structures. As discussed here, anomalous scattering is also useful for characterizing complex systems with mixed and partial occupancies, where true electron density is represented by unresolvable ensemble averages. The solvent environment surrounding nucleic acids is an example of such a system, as are some DNA-ligand systems. The atomic number and wavelength dependencies of anomalous scattering allow one to filter out the electron densities of C, N, and O, and to cleanly visualize the electron densities of heavier atoms. Therefore, anomalous scattering can make beacons of selected atoms. In addition, anomalous scattering provides a model-independent method for determining atomic identities. Here, we describe applications of anomalous scattering to the structure determination of DNA-platinum complexes and in cation associations of free DNA, of DNA-anthracycline complexes, of chemically modified DNA, and of DNA-protein complexes. The utility of Rb{sup +} and Tl{sup +} as K{sup +} substitutes is supported by similarities in Rb{sup +} and Tl{sup +} association with DNA.

59 BASIC BIOLOGICAL SCIENCES↗

Langmuir probe analysis of highly electronegative plasmas

A Langmuir probe analysis of highly electronegative plasmas is proposed. Analytical models are used to fit the IV-characteristics and their second derivatives above and below the plasma potential. Ion and electron densities are obtained for {alpha} (negative ion to electron density ratio) up to 3000, and the temperature of negative and positive ions is obtained for {alpha} ranging from 100 to 3000. The transport across a localized magnetic barrier is studied using this technique. It is shown that an ion-ion (electron free) plasma is formed downstream from the barrier at the highest magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗