Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Temporal Patterns in Soil Redox Potential Vary Across a Freshwater Coastal Delta

Widespread and persistent flooding is submerging coastal ecosystems, particularly along the Louisiana Gulf coast, where flooding results from the compounding effects of ground subsidence and rising sea level. Restoration projects aim to mitigate land loss by diverting sediment loads from rivers into degraded areas to increase ground elevation. To predict how coastal ecosystems will change over time in response to projected changes in relative sea level and restoration, it is necessary to understand how subsurface biogeochemical processes respond to dynamic hydrologic forcings. Here, this study evaluates how environmental parameters that integrate biogeochemical processes vary with water table fluctuations in the freshwater Wax Lake Delta (WLD) in Louisiana, USA, where water diversions have formed one of the only active deltas along the coast. High‐frequency observations of water level, soil redox potential, specific conductance and pH were made for 1 year along elevation transects located on the older, proximal and younger, distal ends of a deltaic island. Redox responded rapidly to changing water tables, with fluctuations occurring primarily in shallow soils (< 20 cm) and at higher elevations. Deeper soils and those at lower elevation remained inundated and reduced. Semi‐diurnal tidal fluctuations were pronounced in younger, distal soils, presumably due to rapid groundwater exchange with the river channel. Tidal signals were muted in older soils that instead exhibited seasonal variability associated with river discharge and evapotranspiration. Although much of the delta sediments are persistently reducing and anoxic, redox fluctuations in the natural levees that border the deltaic islands likely drive high rates of biogeochemical activity. Evaluating how hydrology drives the frequency and duration of redox fluctuations provides a basis for understanding how biogeochemical processes might vary with complex hydrological interactions in coastal systems.

Herndon, Elizabeth [Oak Ridge National Laboratory ↗

Mechanical properties, failure mechanisms, and scaling laws of bicontinuous nanoporous metallic glasses

Molecular dynamics simulations are employed to study the mechanical properties of nanoporous Cu x Zr 1-x metallic glasses (MGs) with five different compositions, x = 0.28, 0.36, 0.50, 0.64, and 0.72, and porosity in the range 0.1 < Φ < 0.7. Results from tensile loading simulations indicate a strong dependence of Young's modulus, E, and Ultimate Tensile Strength (UTS) on porosity and composition. By increasing the porosity from Φ = 0.1 to Φ = 0.7, the topology of the nanoporous MG shifts from closed cell to open-cell bicontinuous. The change in nanoporous topology enables a brittle-to-ductile transition in deformation and failure mechanisms from a single critical shear band to necking and rupture of ligaments. Genetic Programming (GP) is employed to find scaling laws for E and UTS as a function of porosity and composition. Here, a comparison of the GP-derived scaling laws against existing relationships shows that the GP method is able to uncover expressions that can predict accurately both the values of E and UTS in the whole range of porosity and compositions considered.

36 MATERIALS SCIENCE↗

A real-time multiphysics model of a pressurized solid oxide electrolysis cell (SOEC) for cyber-physical simulation

Solid oxide electrolysis cells (SOEC) can play important roles in integrated energy systems (IES) as the hydrogen production hub and the resilience energy hub. When tied to a microgrid with high renewable penetration, the SOEC is subjected to rapid load transitions in response to the intermittent renewable generations that occur not only in diurnal cycles but also in short timeframes (e.g., sub-minute). The cyber-physical simulation approach can derisk operability research but requires a real-time dynamic SOEC model. In the present work, a real-time multiphysics model for pressurized SOEC is developed and validated in the pressure range from 1.4 to 8bar. Further, the accuracy of the single repeating unit (SRU) assumption in SOEC stack simulation is quantified. A guidance of more than 45 cells in one SOEC stack is recommended to safely apply the SRU assumption. Modeling results suggest that at a given current density, more power is consumed by SOEC at elevated operating pressures. The anode air and cathode stream have major impacts on thermal management, highlighting the potential benefit of integrating SOEC with other thermal processes in IES. To achieve high hydrogen production efficiency, the SOEC could operate at the maximum endothermic point to maximize the use of thermal energy. The real-time execution of the developed SOEC model is also demonstrated, which only takes 0.1% of the fixed time step of 5ms. The developed model establishes the basis for cyber-physical simulation of SOEC hybrid systems.

25 ENERGY STORAGE↗

Disruption modelling for engineering and physics design of ST-E1 fusion power plant

Plasma disruptions represent a critical challenge for high-performance tokamak operations, as they can compromise machine integrity and reduce operational availability. Although future fusion devices essentially need to incorporate strategies to minimise disruption occurrence, complete avoidance remains unattainable. Consequently, assessing and characterising unmitigated disruption consequences is fundamental for the design and qualification of next-generation fusion power plants. This work supports the pre-conceptual design of ST-E1, a low aspect-ratio Tokamak Fusion Power Plant developed by Tokamak Energy Ltd., by presenting a comprehensive disruption modelling approach applied across different design stages. The methodology integrates both physics and engineering considerations to evaluate the impact of disruptions on machine performance and structural integrity. From an engineering perspective, several ST-E1 layout options were analysed to investigate the electromagnetic response of key components under disruption-induced loads, enabling comparison between alternative design solutions. On the physics side, a broad set of disruption scenarios was explored, scanning operational space parameters, plasma-material interactions, and associated thermal loads. Furthermore, the study examined variations in disruption behaviour arising from different reference equilibria, focusing on a range starting from Double Null to Single Null configurations, reflecting the increasing up-down asymmetry consequences. The results reveal significant contrasts in plasma dynamics and structures electromagnetic behaviour between configurations, highlighting the importance of disruption modelling in guiding design choices. These analyses have proven instrumental in shaping ST-E1 development, offering critical insights for mitigating risks and optimising future fusion power plant designs.

Borowiec, Katarzyna [ORNL] (ORCID:0000000335911739↗

Automotive fuel cell stack and system efficiency and fuel consumption based on vehicle testing on a chassis dynamometer at minus 18 °C to positive 35 °C temperatures

In this work we present an in-depth laboratory technology assessment of a 2016 Toyota Mirai Fuel Cell (FC) vehicle based on chassis dynamometer testing. The 114.6 kW FC stack has a high dynamic response, which makes this powertrain a FC-dominant hybrid electric vehicle. The measured peak efficiency is 66.0% FC stack and 63.7% FC system with an idle hydrogen flow rate of 4.39 g/hr. The high FC system efficiencies at low loads match typical vehicle power spectrums, resulting in a high average vehicle efficiency of 62% compared to 45% and 23% for a hybrid electric vehicle and a conventional vehicle, respectively. An energy breakdown accounts for the FC stack losses, FC system losses, air compressor loads, and heater loads for different drive cycles and different thermal conditions. The cold-start North American city drive cycle (UDDS) energy consumption values are, respectively, 758, 581, 226, and 321 Wh/km at ambient conditions of -18 degrees C, -7 degrees C, -25 degrees C and 35 degrees C with 850 W/m 2 of solar loading. The FC system shutdown and startup processes at temperatures below the freezing point contribute to the increased hydrogen consumption. Additionally, the raw test data files are available for download, thus providing the research community with a public reference data on a modern production automotive FC system.

08 HYDROGEN↗

A concurrent irradiation-mechanics multiscale coupling model

The vast majority of our current knowledge regarding the basic mechanisms controlling irradiation effect on mechanical properties is based almost entirely on the results of post-irradiation experiments or theoretical models. However, the concurrent effects of irradiation, mechanical stress, and thermal damage on the failure phenomena of materials and components remain largely unexplored due to its internal multiscale-multiphysics coupling nature. Here, we present here a concurrent irradiation-mechanics multiscale coupling model. The concurrent evolutions of nanoscale irradiation defect clusters, microscale dislocation configurations, and mechanical responses are well captured based on coupling cluster dynamics, discrete dislocation dynamics, and the finite element methods using an effective time marching scheme. Model predictions of defect densities and size are in general agreement with experimental observations. Irradiation hardening is shown to take place also in samples undergoing concurrent irradiation-mechanical loading, similar to samples tested post-irradiation. However, the occurrence of plastic flow localization and dislocation channel formation is not accompanied with apparent yield drop (softening) under concurrent irradiation-mechanical loading conditions, which is different from the post-irradiation case.

42 ENGINEERING↗

Dynamic characterization and performance evaluation of a 10-kW power take-off with mechanical motion rectifier for wave energy conversion

The power take-off (PTO) is a key component for wave energy converters. In this paper, a compact PTO with mechanical motion rectification rated at 10 kW is designed and prototyped, and characterized. A piecewise nonlinear dynamic model is established to describe its unique dynamic property. A linear hydraulic actuator is adopted in lab testing to drive the prototype and the unknown parameters of the dynamic model are identified. Further verification shows that the model can predict the dynamic performance of the PTO well. The test results show that the mechanical motion rectifier-based PTO can achieve overall energy transfer efficiency as high as 65% in regular waves even when the generator is working below the rated electric load and speed. In the irregular wave test, the PTO achieved the overall energy transfer efficiency of 54%, and the peak-to-average ratio acquired during the test is 12.5.

16 TIDAL AND WAVE POWER↗

Restructuring of the Lewis Acid Sites in Y-Modified Dealuminated Beta-Zeolite by Hydrothermal Treatment

Yttrium-modified dealuminated Betazeolite (Y-BEA) represents a type of Lewis acid zeolite that has gained attention for its potential to efficiently catalyze the conversion of biomass-derived oxygenates. The structure of the Y active sites and their dynamics during biomass conversion reactions, which normally involve substantial amounts of water, necessitate thorough investigation for the rational design of more active and stable catalysts. Here, we conducted a study where a series of Y-BEA catalysts with different yttrium loadings (1–7 wt.%) were subjected to hydrothermal treatment (450 °C, 20% water) and investigated for their structural and catalytic activity changes through a combination of multiple characterizations and kinetic measurements. The number of acid sites of Y-BEA decreased without a change in acid strength following the hydrothermal treatment, which was confirmed by the results of acid site titration, infrared spectroscopy of probe molecules, and kinetic measurements for probe reactions (acetone aldol condensation). Structural analysis using X-ray diffraction (XRD), specific surface area measurement, X-ray absorption spectroscopy (XAS), and X-ray photoelectron spectroscopy (XPS) demonstrated that both the zeolite structure and the isolation status of the Y site remain intact after hydrothermal treatment. Further, the Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) spectra, thermogravimetric analysis (TGA), and operando 1 H and 29 Si magic-angle spinning (MAS) nuclear magnetic resonance (NMR) revealed the dehydroxylation of Y-BEA induced by hydration-rearrangement-condensation restructuring during the high-temperature steam treatment. Dehydroxylation affects the structure of Y sites by reducing their vicinal silanol sites. In conclusion, this conversion of Lewis acidic Y sites into nonacidic sites is the primary factor behind the change in acid site quantity and catalytic activity on Y-BEA.

36 MATERIALS SCIENCE↗

Experimental shock Hugoniot and melt boundary temperatures of aluminum

Aluminum is a ubiquitous component in dynamic compression, pulsed power, and other high energy density physics studies. Its high-pressure behavior and phase diagram are extensively studied standards in shockwave physics. While theoretical calculations and multiphase equations of state have been benchmarked to velocity measurements of loading and unloading waves, pressure and density under shock, and other mechanical data, experimental temperature data under these conditions have not been reported. We conducted a series of experiments shocking and releasing aluminum 6061 and 1100 samples into lithium fluoride windows. We measured temperature at the sample–window interface under steady compression and subsequent isentropic release. These results allow us to constrain the temperature of the solid Hugoniot and the boundary between the liquid and face-centered cubic solid phases.

Hartsfield, Thomas Murray [Sandia National Laborat↗

Socially-aware evaluation framework for transportation

Technological advancements are rapidly changing traffic management in cities. Navigation applications, in particular, have impacted cities in many ways by rerouting traffic. As different routing strategies distribute traffic differently, understanding these disparities across multiple city-relevant dimensions is extremely important for decision-makers. We develop a multi-themed framework called Socially- Aware Evaluation Framework for Transportation (SAEF), which assists in understanding how traffic routing and the resultant dynamics affect cities. The framework is presented for four Bay Area cities, for which we compare three routing strategies - user equilibrium travel time, system optimal travel time, and system optimal fuel. The results demonstrate that many neighborhood impacts, such as traffic load on residential streets and around minority schools, degraded with the system-optimal travel time and fuel routing in comparison to the user-equilibrium travel time routing. The findings also show that all routing strategies subject the city's disadvantaged neighborhoods to disproportionate traffic exposure. Our intent with this work is to provide an evaluation framework that enables reflection on the consequences of traffic routing and management strategies, allowing city planners to recognize the trade-offs and potential unintended consequences.

99 GENERAL AND MISCELLANEOUS↗

Master State Distributed Estimator (masde)

The MSE technology provides a distributed state estimation scheme for power utilities by making it a real time dynamic system, versus the static snapshot method used today. This will allow utilities to verify power grid readings and identify false data on the communication network. The prevailing method of estimation takes all the data from the system into a single load flow equation at the utilities command center. This becomes a large algorithm that is very time consuming to solve, providing the engineers only snap shots of the system. The MFD distributes an algorithm to devises that are already installed at various locations on the power grid. This allows for much faster computer times because the algorithms contain magnitudes less data. When each distributed estimator completes its calculation, it sends the results back to the master device to check against all other distributed estimators.

Reen, DylanW.↗

STOCHASTIC OPTIMAL POWER FLOW FOR REAL-TIME MANAGEMENT OF DISTRIBUTED RENEWABLE GENERATION AND DEMAND RESPONSE (Final Report)

To meet the grand challenge of a sustainable energy future, there has been a surge of interest in renewable energy. Today, the uncertainty associated with renewable resources is handled by using operating reserves. The high penetration of renewable resources, however, introduces difficult-to-control dynamics and challenges for power system operation. Decision support tools are necessary at the bulk system operational level to recognize and efficiently utilize renewable resources and distributed demand response products in concert with traditional grid resources. It is envisaged that responsive load can potentially have very significant cost advantages over either spinning or non-spinning ramping reserve. Critical decisions are made during hour(s)-ahead and real-time power system operation regarding the commitment and dispatch of generators to ensure power delivery is both reliable and economic. These decisions are typically made by a security constrained optimal flow, which determines future generator commitments, dispatches, and ensures adequate reserves are available in the event of a contingency (unexpected outage) or if future system conditions deviate from forecasts. However, security has been always based on a pre-specified subset of contingency constraints whose enforcement does not guarantee security under all possible future possibilities while also giving little or no weight to the likelihood of each contingent event or the severity of its consequences. Existing tools, which are based exclusively on deterministic optimization models, do not yield optimal operational decisions to address these new challenges, in terms of both reliability and cost-effectiveness. This project has focused on developing a stochastic optimal power flow (SOPF) framework, which integrates renewable resource uncertainty, load uncertainty, distributed storage (DS), demand response (DR) products, in a holistic manner to address the uncertainty associated with ever-increasing renewable resources, along with the inclusion of distributed demand response products in future power systems. A proof-of-concept problem was created using the Pennsylvania-Jersey-Maryland (PJM) power system network. Synthetic wind generation was added to the system to simulate 50% wind penetration. A 1-hour test of SOPF operation indicated more than 6% operational cost savings. The project continued by adding the Midwestern Independent System Operator (MISO) as a partner, with focus shifting from SOPF to Stochastic Look-Ahead Unit Commitment (SLAC). Unlike PJM, MISO is faced with significant renewable energy resources within its footprint and is challenged with substantial uncertainty in its operations. The SLAC distinguishes itself from existing tools that operators use. At best, today’s tools solve two to three cases independently, where one or two system parameters, such as forecasted load level (e.g., a low, base, and high forecast), are varied and the resulting scenarios are analyzed independently. The stochastic-based optimization of SLAC leverages statistical information from an ensemble of potential operational scenarios and their respective likelihood. The SLAC output can be translated into valuable information to the operator such as suggested commitments, optimal scheduling and dispatch of resources, reserve requirements at both locational and zonal resolutions, ramping availability and requirements, availability of demand response including operational guidance concerning the near-term and real-time coordination between distributed energy resources, and utilization of distributed storage resources. The developed SOPF/SLAC tool, a stand-alone tool compatible with existing EMSs, will provide system operators with unprecedented visibility, flexibility and predictability to these resources and operational guidance concerning the real-time coordination between DERs and DR/DS products. The game changing and practical impact of this disruptive technology will be dramatic and will usher in a new era in the electric power industry, wherein green energy concepts are fully embraced, and electric power costs are lowered throughout the nation.

42 ENGINEERING↗

Packaging a 650V/400A GaN Half-bridge Power Module with Ultra-low Parasitics for Electric Vehicle Drive Applications

This paper proposes a compact and efficient half-bridge power module with three 650 V / 150 A GaN dies in parallel. The power module incorporates a main power printed circuit board (PCB), an interface PCB, and a flex PCB to achieve low parasitics in both power loop and gate-side connection, resolving the issue of high parasitics typically encountered with wire bonding in high-current applications. Additionally, the interface PCB decouples the design constraints between the power loop and the gate loops. The proposed design is optimized with a vertical loop configuration to reduce power loop inductance through magnetic flux cancellation. Finite element analysis indicates that the power loop inductance is 0.58 nH at 100 MHz, while the maximum die junction temperature reaches 131 °C under an ambient temperature of 65 °C and a load current of 385 A. The proposed multi-piece PCB structure reduces the inductance of the drive circuit to minimize EMI and to mitigate false triggering. At the same time, it reduces impedance mismatches across different driver circuits, thereby achieving dynamic current sharing in multi-chip parallel configurations. Under simulation conditions of 400 V / 385 A, the current imbalance among chips was limited to 5 A. A 400 V / 385 A double-pulse test was conducted to experimentally validate the performance of the proposed power module.

30 DIRECT ENERGY CONVERSION↗

A Smart and Flexible Microgrid with a Low-cost Scalable Open-source Controller (Final Report)

This report contains information regarding the activities carried out in the project "A Smart and Flexible Microgrid with a Low-cost Scalable Open-source Controller. The project aims at developing a community-based flexible microgrid (FMG) with smart grid features, including multiple utility feeders and dynamic boundaries that utilize intelligent switches and ultra-high-speed communication links already in a smart grid. The project also aims at developing a corresponding controller for such an FMG with low cost and high scalability. With distributed renewable energy resources (DERs) and the intelligent microgrid controller, the FMG will achieve aggressive emission reduction, increased energy use efficiency, and reliability improvement goals. The FMG and its controller design will be scalable for different geographic areas, load sizes, distributed generation source number and types, and even multiple MGs within a distribution electric power system. In order to achieve these project objectives, three main development tasks were carried out: FMG design, FMG controller development, and FMG controller testing. The fourth task was technology to market.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling the Moisture Content and Dry Matter Loss in Dynamic Woody Biomass Storage Piles with Variable Extraction

The urgent need to mitigate climate change has spurred significant interest in renewable energy sources. This paper explores the storage and processing of woody biomass for biofuel production, considering the dynamic nature of biomass piles in real-world scenarios. A model has been developed to analyze moisture content changes and dry matter loss in woody biomass stored in piles prior to processing, taking into account varying extraction methods and environmental conditions. Case studies that examine the effects of different unpiling methods (FIFO, LIFO, and homogeneous) on moisture content and dry matter loss under various feedstock arrival rates and weather conditions are presented. Results indicate that unpiling methods significantly impact moisture content, with LIFO typically resulting in higher moisture content due to the utilization of fresher feedstock. Dry matter loss increases with pile size and time, emphasizing the importance of accurate modeling for assessing carbon emissions and feedstock quality. Furthermore, the model highlights the importance of process loading order and extraction methods in biomass storage, suggesting potential cost benefits associated with decreased moisture content. The difference between different extraction methods could vary the moisture content in the feedstock reaching the biofuel process by as much as 37.6%, however dry matter loss varies minimally for realistic pile changes. Overall, this research contributes to a better understanding of biomass storage dynamics and informs sustainable biofuel production practices.

Niska, Janel↗

Streamlined Loads Analysis of Floating Wind Turbines With Fiber Rope Mooring Lines: Preprint

This paper presents an approach for more accurate yet relatively streamlined accounting for the nonlinear characteristics of synthetic fiber rope mooring lines for floating wind turbines. First, we select a minimal set of parameters that can efficiently approximate a mooring line material's quasi-static and dynamic stiffness characteristics. We also develop a set of baseline coefficients for different rope materials based on published product information and research papers. We then expand a quasi-static mooring model to include dynamic mooring line stiffness terms in a way that allows the nonlinear stiffness behavior of fiber ropes to be considered even in quasi-static analyses. For dynamic analysis, we have updated the model MoorDyn, coupled with OpenFAST, to work with the new dynamic mooring line stiffness terms. This includes the implementation of a new viscoelastic approach that allows the tension-strain relation of each mooring line segment to vary between two stiffness values depending on the strain rate. After presenting the formulation of the approaches for modeling synthetic ropes, they are demonstrated on a floating wind turbine mooring system with taut polyester rope mooring lines. The results are compared with those of other approaches of similar fidelity including the static-dynamic method and separate simulations with static and dynamic stiffness values. Comparing the results shows the ability of the new method to match the results of the previous methods in a more streamlined manner.

elasticity↗

Direct comparison between experiments and dislocation dynamics simulations of high rate deformation of single crystal copper

A long standing challenge in computational materials science is to establish a quantitative connection between the macroscopic properties of plastic deformation with the microscopic mechanisms of dislocations in crystalline materials. Although the discrete dislocation dynamics (DDD) simulation method has been developed for several decades with the goal of addressing this challenge, a one-to-one comparison between the DDD predictions on single crystal stress–strain curves and experimental measurements under identical conditions has not been possible to date. Such a comparison is an essential step towards establishing a dislocation-physics based theory of plasticity and a multiscale framework of the plastic behaviors of crystalline materials. Here we provide direct comparisons between the stress–strain curves of Cu single crystals under high strain rate loading in the [0 0 1] and [0 1 1] directions obtained from miniaturized desktop Kolsky bar experiments and those from DDD simulations under identical loading conditions. With an appropriate set of parameters, DDD simulations can produce stress–strain curves that are in reasonable agreement with the experimental results. However, the dislocation mobility values needed to achieve this agreement are an order of magnitude lower than expected based on previous measurements and atomistic simulations. We hypothesize that this discrepancy could be caused by drag forces from jogs and point defects produced during the plastic deformation. Cross-slip of screw dislocations is also found to be necessary to capture the experimental stress–strain behavior, especially for the [0 1 1] loading direction. Finally, this work provides an example of how direct comparisons between DDD simulations and experimental measurements can provide new insight into the fundamental mechanisms of plastic deformation.

36 MATERIALS SCIENCE↗

Modelica-based system modeling for studying control-related faults in chiller plants and boiler plants serving large office buildings

System modeling is critical when studying operation faults in chiller plants and boiler plants. However, current fault models have difficulties faithfully representing the operation of chiller plants and boiler plants under the effects of those faults, especially the control-related ones. In this study, we present a systematic method to develop high-fidelity models for approximating the behaviors of chiller plants and boiler plants under faulty conditions. Compared to existing ones, the resulting fault models have two advantages: first, they better characterize the dynamic patterns in the system operation. In those models, control architecture and control logic are faithfully implemented. Thus, they can be used to study control-related faults, such as incorrect staging control due to sensor bias and mistuned feedback control. Second, they are readily extensible and can support large-scale investigations to explore different faulty conditions/scenarios. Those models are established in a hierarchical structure while modules in each layer can be redeclared and parameterized at upper layers. In such a case, modifications to the models can be realized through model modifiers and the process can be easily streamlined with scripts. We applied the proposed models in a comprehensive fault impact evaluation of the 13 control-related faults of chiller and boiler plants. In this evaluation, the proposed plant model is coupled with the EnergyPlus thermal load model to study the impact of various faulty scenarios. Based on the evaluation results, we identified the faults that have the most significant impacts on the operation of the chiller and boiler plants, respectively. We also found that the relationship between the impacts of the studied faults and the severity level of the faults are highly non-linear

Huang, Sen↗