Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed services”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Fundamental Drivers of the Cost and Price of Operating Reserves

Operating reserves impose a cost on the electric power system by forcing system operators to keep partially loaded spinning generators available for responding to system contingencies variable demand. In many regions of the United States, thermal power plants provide a large fraction of the operating reserve requirement. Alternative sources of operating reserves, such as demand response and energy storage, may provide more efficient sources of these reserves. However, to estimate the potential value of these services, the cost of reserve services under various grid conditions must first be established. This analysis used a commercial grid simulation tool to evaluate the cost and price of several operating reserve services, including spinning contingency reserves and upward regulation reserves. These reserve products were evaluated in a utility system in the western United States, considering different system flexibilities, renewable energy penetration, and other sensitivities. The analysis demonstrates that the price of operating reserves depend highly on many assumptions regarding the operational flexibility of the generation fleet, including ramp rates and the fraction of fleet available to provide reserves.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Opportunities for Battery Storage Technologies in Mexico

This report provides a high-level summary of the current market trends for batteries and discusses the role battery storage technologies can play in Mexico's transition towards higher penetrations of variable renewable energy generation. This includes: frequency regulation, transmission upgrade deferral, distributed generation, and serving peak demand.

25 ENERGY STORAGE↗

Enhancement of the Acoma Utility Authority

The goal of this project was to establish an energy utility department within the existing Pueblo of Acoma Utility Authority (PAUA). The ultimate goal is for PAUA to establish a self-sustaining energy utility department within its existing organization, to help fulfill its mission of providing safe and reliable utilities services to the community at an affordable cost, while promoting conservation and efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience Service Framework Using Transactive Systems Valuation Methodology

Recent outage events have spurred national and international interest in improving grid resilience. Actions to make the grid more resilient must be valued against their costs and benefits. This is the goal of this report. We explore a resilience valuation framework, where the services procured by the utility are arranged such that the values associated with them are pinpointed. This is demonstrated by utilizing various diagrams developed in Pacific Northwest National Laboratory’s Transactive System Program, called the Transactive Systems Valuation Methodology (TSVM). We show that TSVM can be utilized to guide traditional valuation methodologies such as integrated resource planning so that resilience considerations can be embedded. This report demonstrates this using a three-step procedure: (1) a use case is developed to define functional requirements, (2) value identification of the utility and the actors with which it interacts (both inside and outside its internal functions), and (3) value tracking of activity performed by actors interacting with the utility while services are procured to enable a resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quality Assurance Framework for Mini-Grids

Providing clean and affordable energy services to the more than 1 billion people globally who lack access to electricity is a critical driver for poverty reduction, economic development, improved health, and social outcomes. More than 84% of populations without electricity are located in rural areas where traditional grid extension may not be cost-effective; therefore, distributed energy solutions such as mini-grids are critical. To address some of the root challenges of providing safe, quality, and financially viable mini-grid power systems to remote customers, the U.S. Department of Energy (DOE) teamed with the National Renewable Energy Laboratory (NREL) to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The QAF for mini-grids aims to address some root challenges of providing safe, quality, and affordable power to remote customers via financially viable mini-grids through two key components: (1) Levels of service: Defines a standard set of tiers of end-user service and links them to technical parameters of power quality, power availability, and power reliability. These levels of service span the entire energy ladder, from basic energy service to high-quality, high-reliability, and high-availability service (often considered 'grid parity'); (2) Accountability and performance reporting framework: Provides a clear process of validating power delivery by providing trusted information to customers, funders, and/or regulators. The performance reporting protocol can also serve as a robust monitoring and evaluation tool for mini-grid operators and funding organizations. The QAF will provide a flexible alternative to rigid top-down standards for mini-grids in energy access contexts, outlining tiers of end-user service and linking them to relevant technical parameters. In addition, data generated through implementation of the QAF will provide the foundation for comparisons across projects, assessment of impacts, and greater confidence that will drive investment and scale-up in this sector. The QAF implementation process also defines a set of implementation guidelines that help the deployment of mini-grids on a regional or national scale, helping to insure successful rapid deployment of these relatively new remote energy options. Note that the QAF is technology agnostic, addressing both alternating current (AC) and direct current (DC) mini-grids, and is also applicable to renewable, fossil-fuel, and hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The globus compute dataset: An open function-as-a-service dataset from the edge to the cloud

Here we present a unique function-as-a-service (FaaS) dataset capturing the use of the Globus Compute (previously funcX) platform. Globus Compute implements a federated model via which users may deploy endpoints on arbitrary remote computers, from the edge to high performance computing (HPC) cluster, and they may then invoke Python functions on those endpoints via a reliable cloud -hosted service. The dataset covers 31 weeks and includes 2121472 task submissions from 252 users executed on 580 remote computing endpoints. It includes 277386 registered functions. We describe the dataset and various observations, some that are similar to other FaaS datasets, for example, that 74% of tasks run for less than 1 s, and some that are unique to Globus Compute, for example, that endpoints are used in different ways and that the majority of functions are related to scientific computing and machine learning. To the best of our knowledge, this dataset represents the first federated FaaS dataset that includes user workloads, distributed computing endpoints, and analysis of registered function bodies. We expect the dataset to be useful for researching FaaS architectures, workload modeling, container warming, and other distributed computing architectures.

97 MATHEMATICS AND COMPUTING↗

Pufferscale: Rescaling HPC Data Services for High Energy Physics Applications

User-space HPC data services are emerging as an appealing alternative to traditional parallel file systems, because of their ability to be tailored to application needs while eliminating unnecessary overheads incurred by POSIX compliance. The High Energy Physics (HEP) community is progressively turning towards such services to enable high-throughput accesses under heavy concurrency to billions of event data produced by instruments and consumed by subsequent analysis workflows. Such services would benefit from the possibility to be rescaled up and down to adapt to changing workloads, as experimental campaigns progress, in order to optimize resource usage. This paper formalizes rescaling a distributed storage system as a multi objective optimization problem considering three criteria: load balance, data balance, and duration of the rescaling operation. We propose a heuristic for rapidly finding a good approximate solution, while allowing users to weight the criteria as needed. The heuristic is evaluated with Pufferscale, a new rescaling manager for microservice-based distributed storage systems. To validate our approach in a real-world ecosystem, we showcase the use of Pufferscale as a means to enable storage malleability in the HEPnOS storage system for HEP applications.

Distributed Storage System↗

Generalized Aggregation and Coordination of Residential Loads in a Smart Community

Flexibility from residential loads presents an enormous potential to provide various services to the smart grid. In this paper, we propose a unified hierarchical framework for aggregation and coordination of various residential loads in a smart community, such as Thermostatically Controlled Loads (TCLs), Distributed Energy Storages (DESs), residential Pool Pumps (PPs), and Electric Vehicles (EVs). A central idea of this framework is a virtual battery model, which provides a simple and intuitive tool to aggregate the flexibility of distributed loads. Moreover, a multi-stage Nash-bargainingbased coordination strategy is proposed to coordinate different aggregations of residential loads for demand response. Case studies are provided to demonstrate the efficacy of our proposed framework and coordination strategy in managing peak power demand in a smart residential community.

Hao, He↗

Distributed Intrusion Detection System using Semantic-based Rules for SCADA in Smart Grid

Cyber-physical system (CPS) security for the smart grid enables secure communication for the SCADA and wide-area measurement system data. Power utilities world-wide use various SCADA protocols, namely DNP3, Modbus, and IEC 61850, for the data exchanges across substation field devices, remote terminal units (RTUs), and control center applications. Adversaries may exploit compromised SCADA protocols for the reconnaissance, data exfiltration, vulnerability assessment, and injection of stealthy cyberattacks to affect power system operation. In this paper, we propose an efficient algorithm to generate robust rule sets. We integrate the rule sets into an intrusion detection system (IDS), which continuously monitors the DNP3 data traffic at a substation network and detects intrusions and anomalies in real-time. To enable CPS-aware wide-area situational awareness, we integrated the methodology into an open-source distributed-IDS (D-IDS) framework. The D-IDS facilitates central monitoring of the detected anomalies from the geographically distributed substations and to the control center. The proposed algorithm provides an optimal solution to detect network intrusions and abnormal behavior. Different types of IDS rules based on packet payload, packet flow, and time threshold are generated. Further, IDS testing and evaluation is performed with a set of rules in different sequences. The detection time is measured for different IDS rules, and the results are plotted. All the experiments are conducted at Power Cyber Lab, Iowa State University, for multiple power grid models. After successful testing and evaluation, knowledge and implementation are transferred to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Energy Resources Customer Adoption Model (DER-CAM) v5.9

The Distributed Energy Resources Customer Adoption Model (DER-CAM) is a powerful and comprehensive decision support tool that primarily serves the purpose of finding optimal distributed energy resource (DER) investments in the context of either buildings or multi-energy microgrids. Version 5.9 introduces significant advancements to DER-CAM, including support for wholesale market integration (ancillary services), storage aging effects, improved solar thermal collector modeling, improved part-load efficiency modeling for conventional generators, added support for hydro generation, among others.

Deforest, Nicholas↗

Photovoltaic Microinverter Testbed for Multiple Device Interoperability

IEEE Standard 1547-2003 conformance of several interconnected microinverters was performed by Sandia National Laboratories (SNL) to determine if there were emergent adverse behaviors of co-located aggregated distributed energy resources. Experiments demonstrated the certification tests could be expanded for multi-manufacturer microinverter interoperability. Evaluations determined the microinverters' response to abnormal conditions in voltage and frequency, interruption in grid service, and cumulative power quality. No issues were identified to be caused by the interconnection of multiple devices.

42 ENGINEERING↗

A Selectivity based approach to Continuous Pattern Detection in Streaming Graphs

Cyber security is one of the most significant technical challenges in current times. Detecting adversarial activities, prevention of theft of intellectual properties and customer data is a high priority for corporations and government agencies around the world. Cyber defenders need to analyze massive-scale, high-resolution network flows to identify, categorize, and mitigate attacks involving net- works spanning institutional and national boundaries. Many of the cyber attacks can be described as subgraph patterns, with promi- nent examples being insider infiltrations (path queries), denial of service (parallel paths) and malicious spreads (tree queries). This motivates us to explore subgraph matching on streaming graphs in a continuous setting. The novelty of our work lies in using the subgraph distributional statistics collected from the streaming graph to determine the query processing strategy. We introduce a “Lazy Search" algorithm where the search strategy is decided on a vertex-to-vertex basis depending on the likelihood of a match in the vertex neighborhood. We also propose a metric named “Relative Selectivity" that is used to se- lect between different query processing strategies. Our experiments performed on real online news, network traffic stream and a syn- thetic social network benchmark demonstrate 10-100x speedups over selectivity agnostic approaches.

graphs, cybersecurity↗

A Selectivity based approach to Continuous Pattern Detection in Streaming Graphs

Cyber security is one of the most significant technical challenges in current times. Detecting adversarial activities, prevention of theft of intellectual properties and customer data is a high priority for corporations and government agencies around the world. Cyber defenders need to analyze massive-scale, high-resolution network flows to identify, categorize, and mitigate attacks involving networks spanning institutional and national boundaries. Many of the cyber attacks can be described as subgraph patterns, with prominent examples being insider infiltrations (path queries), denial of service (parallel paths) and malicious spreads (tree queries). This motivates us to explore subgraph matching on streaming graphs in a continuous setting. The novelty of our work lies in using the subgraph distributional statistics collected from the streaming graph to determine the query processing strategy. We introduce a ``Lazy Search" algorithm where the search strategy is decided on a vertex-to-vertex basis depending on the likelihood of a match in the vertex neighborhood. We also propose a metric named ``Relative Selectivity" that is used to select between different query processing strategies. Our experiments performed on real online news, network traffic stream and a synthetic social network benchmark demonstrate 10-100x speedups over non-incremental, selectivity agnostic approaches.

dynamic graphs↗

Added Value of Reliability to a Microgrid: Simulations of Three California Buildings

The Distributed Energy Resources Customer Adoption Model is used to estimate the value an Oakland nursing home, a Riverside high school, and a Sunnyvale data center would need to put on higher electricity service reliability for them to adopt a Consortium for Electric Reliability Technology Solutions Microgrid (CM) based on economics alone. A fraction of each building's load is deemed critical based on its mission, and the added cost of CM capability to meet it added to on-site generation options. The three sites are analyzed with various resources available as microgrid components. Results show that the value placed on higher reliability often does not have to be significant for CM to appear attractive, about 25 $/kWcdota and up, but the carbon footprint consequences are mixed because storage is often used to shift cheaper off-peak electricity to use during afternoon hours in competition with the solar sources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Energy Storage Cost Comparison: Li-Ion Batteries vs Distributed Load Control

In 2017, San Diego Gas & Electric installed a 30 MW, 120 MWh lithium-ion battery storage facility-the world's largest at the time. But, recent work demonstrates that local control can enable flexible loads to provide equivalent battery-like services to the grid. Our cost comparison shows that it is much cheaper to acquire 30 MW, 120 MWh of capacity by retro-fitting 120,000 water heaters with control hardware and telecommunications. Surprisingly, it may even be cheaper to give away 120,000 'smart' water heaters!

25 ENERGY STORAGE↗

Plan for Post-Irradiation Examination of Zion Reactor Pressure Vessel Beltline Materials

The reactor pressure vessel (RPV) is a potentially life-limiting component in light-water reactors (LWR) because replacement of the RPV is not considered a viable option. Researchers studying the effects of radiation on RPV materials have long been interested in evaluating service-irradiated materials to assess currently available models for predicting radiation embrittlement of RPV steels. The decommissioning of the Zion Unit 1 NPP in Zion, Illinois presents a unique opportunity for characterization of an actual reactor pressure vessel (RPV) material after inservice degradation. The main interests in this case are the belt-line weld and base metals. Through-RPV wall thickness attenuation and chemical composition distributions are the obvious objectives of this characterization program. However, it also provides an opportunity to examine the inservice degradation and its comparison with currently available models for prediction of radiation embrittlement of RPV steels. All of these efforts will provide a better understanding of materials degradation and other issues associated with extending the lifetime of existing NPPs beyond 60 years of service. The primary foci are the Linde 80 flux, wire heat 72105 (WF-70) circumferential belt-line weld and the A533B-1 base metal from the intermediate shell harvested from a region of peak fluence (0.7 x 10{sup 19} n/cm{sup 2}, E > 1.0 MeV) on the internal surface of the Zion Unit 1 vessel. Following determination of the through-thickness chemical composition, Charpy impact, fracture toughness, tensile, and hardness testing will be being performed to characterize the through-thickness mechanical properties of the base metal and belt-line-weld materials. In addition to mechanical properties, microstructural characterizations will be performed using various techniques, including Atom Probe Tomography, Small Angle Neutron Scattering, and Positron Annihilation Spectroscopy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NREL/SCE High Penetration PV Integration Project: FY13 Annual Report

In 2010, the National Renewable Energy Laboratory (NREL), Southern California Edison (SCE), Quanta Technology, Satcon Technology Corporation, Electrical Distribution Design (EDD), and Clean Power Research (CPR) teamed to analyze the impacts of high penetration levels of photovoltaic (PV) systems interconnected onto the SCE distribution system. This project was designed specifically to benefit from the experience that SCE and the project team would gain during the installation of 500 megawatts (MW) of utility-scale PV systems (with 1-5 MW typical ratings) starting in 2010 and completing in 2015 within SCE's service territory through a program approved by the California Public Utility Commission (CPUC). This report provides the findings of the research completed under the project to date.

14 SOLAR ENERGY↗

Advanced Distributed Wind Turbine Controls Series: Part 1-Flatirons Campus Model Overview – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

Wind turbines are typically deployed to provide energy, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL), it is demonstrated that advanced wind turbine controls can be employed to support higher contributions of wind, and to demonstrate ways that wind can play a role in supporting grid stability in islanded or grid-connected configurations. This paper documents models of various subsystem comprising a portion of NREL's Flatirons campus that will be used in three subsequent reports to demonstrate capabilities of advanced wind turbine controls. The series of reports will detail advanced capabilities of distributed wind turbines to provide support to isolated grids, distribution grids, and microgrids. We developed models to simulate a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a diesel generator (2 MW) and various types of loads (critical, dynamic). The model of the subsystems in MATLAB/Simulink are validated with available data from real-world components on NREL's Flatirons Campus. These validated models can be configured for various studies including four MIRACL use cases: 1) isolated grids, 2) microgrids, and 3) behind-the-meter, and 4) front-of-the-meter wind turbine deployments.

17 WIND ENERGY↗