Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data housing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Comparison of ground and flight test results using a modified F106B aircraft

A F106 aircraft was modified by installing two additional underwing nacelles housing afterburning J85 engines to study exhaust nozzles in flight at Mach numbers up to 1.3. Installation effects were determined for several nozzles by comparing flight and wind-tunnel data. The effect is to decrease boattail drag and delay its drag rise Mach number to about 0.98. A study of Reynolds number effects, carried out at subsonic speeds with afterburning turbofan engines showed boattail drag to be sensitive to Reynolds number. In flight, drag was highest at the lowest Reynolds number, and decreased as the Re number was increased. Static and flyover noise measurements showed that, except for special cases, noise levels at takeoff (M = 0.4) were higher than predicted from static data.

Wilcox, F. A.↗

Auxiliary payload power system study for space processing applications payloads. Preliminary requirements study

The preliminary designs, specifications, and programmatic data for the auxiliary payload power system (APPS) are presented. The APPS concept is an independent system to be carried in the Orbiter's cargo bay having the capability of housing and supporting space processing applications (SPA) experiment payloads and augmenting Spacelab power and heat rejection capabilities as required in the performance of these experiments.

Source record↗

New in-flight calibration adjustment of the Nimbus 6 and 7 earth radiation budget wide field of view radiometers

In-flight calibration adjustments are developed to process data obtained from the wide-field-of-view channels of Nimbus-6 and Nimbus-7 after the failure of the Nimbus-7 longwave scanner on June 22, 1980. The sensor characteristics are investigated; the satellite environment is examined in detail; and algorithms are constructed to correct for long-term sensor-response changes, on/off-cycle thermal transients, and filter-dome absorption of longwave radiation. Data and results are presented in graphs and tables, including comparisons of the old and new algorithms.

Kyle, H. L.↗

Review of convectively cooled structures for hypersonic flight

Resurgent interest in development of Aerospace Plane and Orient Express type vehicles promises to stretch structural technology for hypersonic flight vehicles to the uppermost limits. Significant portions of the structure may require active cooling of some type to survive hostile environments. Despite a lack of recent research activity for cooled structures, a significant body of unclassified knowledge exists concerning such structures. Contractual and in-house research conducted mainly by NASA's Langley Research Center during the 60's and 70's on vehicles very similar to the proposed Orient Express has provided a substantial data base for convectively cooled hypersonic flight structures. Specifically, results are presented for regeneratively cooled structural concepts which have a relatively high heat flux capability and use the hydrogen fuel directly as a coolant; and for structural concepts which use a secondary coolant loop to absorb incident heating and then transfer the absorbed heat to the liquid hydrogen fuel as it flows to the engines. Results are presented to indicate application regions in terms of heat flux capability for various concepts and benefits for each concept. Experience gained and costs are discussed in terms of heat flux capability for various concepts and benefits for each concept. Additionally, experience gained and cost involved with design, fabrication, and testing of full-scale convectively cooled structures are discussed.

Shore, Charles P.↗

Cathodic Protection Deployment on Space Shuttle Solid Rocket Boosters

Corrosion protection of the space shuttle solid rocket boosters incorporates the use of cathodic protection(anodes) in concert with several coatings systems. The SRB design has large carbon/carbon composites(motor nozzle) electrically connected to an aluminum alloy structure. Early in the STS program, the aluminum structures incurred tremendous corrosive attack due primarily to the galvanic couple to the carbon/carbon nozzle at coating damage locations. Also contributing to the galvanic corrosion problem were stainless steel and titanium alloy components housed within the aluminum structures and electrically connected to the aluminum structures. This paper will highlight the evolution in the protection of the aluminum structures, providing historical information and summary data from the operation of the corrosion protection systems. Also, data and information will be included regarding the evaluation and deployment of inorganic zinc rich primers as anode area on the aluminum structures.

Zook, Lee M.↗

Multifunction Habitat Workstation/OLED Development

This paper gives a general outline of both a multifunction habitat workstation and the research put into an Organic Light Emitting Diode (OLED) device. It first covers the tests that the OLED device will go through to become flight ready along with reasoning. Guidelines for building an apparatus to house the display and its components are given next, with the build of such following. The three tests the OLED goes through are presented (EMI, Thermal/Vac, Radiation) along with the data recovered. The second project of a multifunction workstation is then discussed in the same pattern. Reasoning for building such a workstation with telepresence in mind is offered. Build guidelines are presented first, with the build timeline following. Building the workstation will then be shown in great detail along with accompanying photos. Once the workstation has been discussed, the versatility of its functions are given. The paper concludes with future views and concepts that can added when the time or technology presents itself.

Schumacher, Shawn↗

FAST v8 Verification and Validation for a Megawatt-Scale Wind Turbine with Aeroelastically Tailored Blades: Preprint

This paper presents findings from a verification and validation exercise on the latest version of the U.S. Department of Energy/National Renewable Energy Laboratory's in-house wind turbine aeroelastic design code FAST v8. Results from a set of 1141 FAST simulations were compared to those from Siemens' BHawC design code results, as well as experimental data from a heavily instrumented 2.3-MW Siemens wind turbine located at the National Wind Technology Center. The code validation was performed following the IEC-61400-13 standard, where a set of select quantities of interest from simulations at various wind speed and atmospheric turbulence conditions were used for a three-way comparison between FAST, BHawC, and the measurements. Results highlight many improvements of the latest version of FAST over its previous versions. This paper also provides comments from the authors on the data quality, and avenues for potential future work using these results.

17 WIND ENERGY↗

ACCELEROMETERS IN FLOW FIELDS: A STRUCTURAL ANALYSIS OF THE CHOPPED DUMMY INPILE TUBE

Four tests characterizing the structural response of the Chopped-Dummy In-Pile tube (CDIPT) experiment design were measured in the Hydro-Mechanical Fuel Test Facility (HMFTF). Four different test configurations were tried. These configurations tested the pressure drop and flow impact of various plate configurations and flow control orifices to be used later at different reactor power levels. Accelerometers were placed on the test vehicle and flow simulation housing. A total of five accelerometers were used with one on the top and bottom of the flow simulator and vehicle, and one on the outside of the flow simulator. Data were collected at a series of flow rates for 5 seconds each at an acquisition rate of 2 kHz for a Nyquist frequency of 1 kHz. The data were then analyzed using a Fast Fourier Transform (FFT) algorithm. The results show very coherent vibrations of the CDIPT experiment on the order of 50 Hz in frequency and 0.01 m/s2 in magnitude. The coherent vibrations, although small in magnitude pose a potential design problem if the frequencies coincide with the natural frequency of the fueled plates or test vehicle. The accelerometer data was integrated and combined to create a 3D trace of the experiment during the test. The merits of this data as well as further anomalies and artifacts are also discussed as well as their relation to the instrumentation and experiment design.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accelerometers in flow fields: a structural analysis of the chopped dummy in-pile tube

Four tests characterizing the structural response of the Chopped-Dummy In-Pile tube (CDIPT) experiment design were measured in the Hydro-Mechanical Fuel Test Facility (HMFTF). Four different test configurations were tried. These configurations tested the pressure drop and flow impact of various plate configurations and flow control orifices to be used later at different reactor power levels. Accelerometers were placed on the test vehicle and flow simulation housing. A total of five accelerometers were used with one on the top and bottom of the flow simulator and vehicle, and one on the outside of the flow simulator. Data were collected at a series of flow rates for 5 seconds each at an acquisition rate of 2 kHz for a Nyquist frequency of 1 kHz. The data were then analyzed using a Fast Fourier Transform (FFT) algorithm. The results show very coherent vibrations of the CDIPT experiment on the order of 50 Hz in frequency and 0.01 m/s{sup 2} in magnitude. The coherent vibrations, although small in magnitude pose a potential design problem if the frequencies coincide with the natural frequency of the fueled plates or test vehicle. The accelerometer data was integrated and combined to create a 3D trace of the experiment during the test. The merits of this data as well as further anomalies and artifacts are also discussed as well as their relation to the instrumentation and experiment design. (authors)

42 ENGINEERING↗

Cold Climate Degradation: An Analysis of Double-Axis Tracked, E-W Vertical, and Fixed-Tilt Photovoltaic Deployments in Alaska

As countries around the world transition towards renewable energy, there is increasing interest in using photovoltaic (PV) technologies to help decarbonize remote northern communities due to their scalability and affordability. However, a major barrier towards large-scale adoption of PV in cold climates is performance uncertainty under extreme environmental conditions including snowfall, freeze-thaw cycles, and high wind loads. Existing literature on PV degradation rates in the North is relatively limited, with published degradation rates varying between -0.2%/year (Sweden) to -1.3%/year (Scotland). At this workshop, we will present preliminary results on the long-term performance of two diverse photovoltaic sites located in Fairbanks, Alaska at 64.8 degrees N: a monofacial Al-BSF double-axis tracking site maintained by the Cold Climate Housing Research Center (CCHRC), and a bifacial PERC/SHJ E-W vertical and south-facing fixed-tilt site maintained by the Alaska Center Energy and Power (ACEP). CCHRC data has been collected over a period of 15 years, while ACEP site data has been collected over 4 years. Using the degradation analysis tool, RdTools, we will present annual system degradation rates, seasonal performance ratio, and identify potential cold climate failure mechanisms for commercially available PV technologies. This analysis will add to existing literature by directly comparing the performance of multiple PV configurations in Alaska.

bifacial↗

Instrumentation for the In-Core Real-Time Mechanical Testing of Structural Materials (INCREASE) Project

Idaho National Laboratory (INL), in collaboration with the Electric Power Research Institute (EPRI), the Nuclear Regulatory Commission (NRC), the French Atomic and Alternative Energies Commission (CEA), the Joint Research Center (JRC), the Nuclear Research and Consultancy Group (NRG), and the Research Center Rez (CVR), started a Joint Experimental Program (JEEP) project that operates within the Nuclear Energy Agency’s Framework for Irradiation Experiments (FIDES II) program in order to develop capabilities for the in-core real-time mechanical testing of structural materials. This effort will focus on designing a shared capsule capable of housing a variety of in-core mechanical testing instrumentation allowing enhanced experiments for the material science community. The outcome of the project would be high-priority, stress relaxation data for stainless-steel-based materials provided by EPRI and CEA. Stress relaxation is a major phenomenon that contributes to material degradation in nuclear reactor components. Currently, nuclear material stress relaxation is assessed both before and after irradiation, using complex and costly post-irradiation examination (PIE) activities. In-situ data would support the development of precision modeling and simulation of this degradation phenomena and would provide validation and benchmarking for existing models using the PIE data. As part of the U.S. Department of Energy Advanced Sensor and Instrumentation (ASI) program, INL has fabricated and tested out-of-core mechanical test instrumentation. This instrumentation was designed for easy adaptation to the irradiation capsule proposed under this JEEP, and can be deployed to measure real-time stress relaxation under pressurized-water reactor (PWR) conditions. This initial effort will partially serve to replace the testing capabilities lost because of shutting down the Halden Boiling Water Reactor (HBWR). The project would provide these capabilities to the international community via a shared capsule design that is easily adaptable to additional material test reactors. The design features will incorporate expansion to PWR and non-light-water reactor (LWR) environments that will be developed in future work. The capsule and instrumentation will be demonstrated in the Massachusetts Institute of Technology Reactor (MITR) for phase I and the Petten High Flux Reactor (HFR) for phase II irradiations to deliver real-time stress relaxation data on high priority stainless steel structural materials.

36 MATERIALS SCIENCE↗

Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate

Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether supplemental dehumidification is a needed and effective investment to promote these long term standards. Data logging equipment was installed at eight test homes in July, 2012 and later at two more test homes in January, 2013. Interior conditions and various end-use loads were monitored until November 7th, 2013. The mechanical systems at each of the 10 homes were commissioned by BSC to ensure consistent operation between each of the homes and to fully comply with the intended mechanical design. PHA-1 to 8 - Energy Savings: 21.8-18.9%, Company: Project Home Again (PHA); Address New Orleans, LA 70112, House Count: 8 BDC-1 - Energy Savings: 28.8%, Company: Broadmoor Development Corporation (BDC); Address New Orleans, LA 70112, House Count: 2

Array↗

Progress in the Measurement of Prompt Neutron Output in Neutron-Induced Fission of 239 Pu: The Chi-Nu Project

Knowledge of the prompt neutron output from neutron-induced fission of 239 Pu is essential to nuclear defense and energy applications. Because the experimental data base is inadequate to constrain models of the spectrum of neutrons from fission, we have embarked on a multi-year program of new measurements of the prompt fission neutron spectrum as a function of the energy of the incident neutron that induces the fission. This is a joint LANL-LLNL project with participation by four university groups in advanced detector development. In the past year much progress has been achieved. The building housing the experiment has been completed and the flight paths including one for this experiment are now constructed. A parallel-plate avalanche counter (PPAC) containing 235 U is installed and working in the beam line. Neutron detectors for both low (<1 MeV) and high (> 0.5 MeV) neutrons have been assembled. The data acquisition system based on waveform digitizers has undergone extensive development and now can handle 10 PPAC channels and 10 neutron detectors simultaneously. In addition, a detector test station centered on a 252 Cf spontaneous fission chamber has been commissioned so that we can characterize our neutron detectors in a well understood experimental environment. Analysis of experiments at this facility has helped us understand the performance of several types of neutron detectors. In addition, the analysis work uncovered that the “standard” 252 Cf fission neutron spectrum in MCNPX disagrees significantly from that presently accepted by the international standards community. One year ago we submitted a report (LA-UR-11-05576) on the accuracies that could be reached under certain assumptions. Several sources of possible systematic uncertainties were identified, and procedures to control these uncertainties were suggested. This report is included as an appendix to this report. One element missing from these estimates was the contribution of backgrounds. It could not be quantified because, at that time, the building and flight path for the experiments had not been constructed. We now have made some measurements of the background and can now add this component to the accuracy projections. This report summarizes the progress in the past year. It also discusses measurements reported in the literature and some factors that should be considered when using these data to optimize parameters in nuclear model codes used in constructing evaluated nuclear data bases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of cosmic-ray correlated events at the Soudan underground laboratory

The ceiling and walls of the Low Background Facility at the Soudan Underground Laboratory are lined proportional tubes which form a 30 m × 17 m ×12 m muon tracker. The data acquisition records GPS-generated time stamps along with position information. The tracker is a refurbished version of the Soudan 2 proton-decay muon veto shield. It can now be used in conjunction with other experiments housed within its walls. Particularly interesting is the possible measurement of cavern muons coincident with high-energy neutron detections in the Neutron Multiplicity Meter (NMM), a 4-tonne gadolinium-loaded water Cherenkov neutron capture detector atop a 20-kilotonne lead target. Here we cover the ability of the shield and co-located detectors to achieve coincident timing resolutions of about 1 microsecond via GPS-synchronized absolute timing electronics. The usage of such technology for constraining muon-neutron correlations underground is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use and Siting of Electric Vehicle Charging Stations in Juneau, Alaska

This report details a study of electric vehicle (EV) Level 2 charging stations in Juneau, Alaska. Utilization analyses of six public over five years and 250 residential chargers over two years are included, and a composite score is introduced to identify optimal locations for future charging stations that target residents of manufactured and multifamily housing (MMFH) in Juneau. We find that public charging station usage is very location-dependent, with three chargers in use more than 60% of days during the peak hour of the day (which ranges from 10 a.m. to 7 p.m.), including a charger near residential housing, illuminating potential needs for additional public chargers in those areas. Residential charging utilization typically occurs overnight - opposite to most public charging stations analyzed - and spikes after 10 p.m. This suggests that Alaska Electric Light & Power Company's time-of-use charging program, which lowers electricity rates at 10 p.m. to incentivize overnight charging, is very effective. Residential charging data also show that households tend to charge 15 hours per week, or 9% of the time, meaning that multiple households could likely share one charger if one were provided near MMFH locations. This is supported by residential charging session analysis, which shows that the median household has around two night charging sessions per week. The EV siting analysis identifies areas of high housing density, low access to public chargers, and unconstrained feeders. A cluster of MMFH parcels in Douglas demonstrated the highest composite scores considering all factors, being the only area to have a perfect score of 2.25.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rapid Response Data Science for COVID-19

This report describes the results of a seven day effort to assist subject matter experts address a problem related to COVID-19. In the course of this effort, we analyzed the 29K documents provided as part of the White House's call to action. This involved applying a variety of natural language processing techniques and compression-based analytics in combination with visualization techniques and assessment with subject matter experts to pursue answers to a specific question. In this paper, we will describe the algorithms, the software, the study performed, and availability of the software developed during the effort.

60 APPLIED LIFE SCIENCES↗

SU-F-T-304: Complex Multi-PTV Treatment Evaluation Using a Remotely Processed 3D Gel Dosimeter

Purpose: A new 3D gel dosimeter (ClearView™, Modus Medical Systems) was investigated for use as a QA tool for stereotactic radiosurgery (SRS) plans exhibiting high dose gradients and spatially separated treatment targets. The unique feature of this gel dosimeter is the remote processing service provided by Modus Medical Systems. Methods: The gel dosimeters were filled in either 10 cm diameter or 15 cm diameter clear plastic jars. The jars were then shipped in ice-cooled containers to our department for irradiation. Clinical SRS plans for treatment of multiple metastases and plans with simulated concave structures were applied to a CT scan of the gel dosimeter. The gel was irradiated in treatment position using modulated arcs and then returned in the cooled container for processing. The 3D gel dose was compared to the DICOM-RT dose from the treatment plan to assess dosimetric and geometric agreement. Results: There was no discernible difference between the planned and measured dose for dose gradients as high as 10%/mm, which was the highest gradient we evaluated. Geometric agreement for distant metastases separated by 6 cm was within 1.5 mm. Among three identically irradiated gels using a plan intended for nine metastases, the 3%/3mm gamma passing rate was 84.5% with a range of 14.7%, measured over the entire volume of the dosimeter. Regions of larger gamma values correlated with geometric offsets between the planned and measured data. Conclusion: The gel dosimeter exhibits the dosimetric and geometric characteristics necessary for 3D evaluation of treatment plan deliverability. The range of observed gamma passing rates suggests a high sensitivity to geometric registration. With proper management of geometric registration between planned and measured data, this service should enable a radiation oncology department to use 3D dosimetry in end-to-end testing or patient plan delivery QA without the expense of an in-house processing system.

60 APPLIED LIFE SCIENCES↗

United States CMM Insights Dataset

Geo-data science applications for critical mineral analysis, development acceleration, economic impact assessment, and project efficiency. Coverage: 10 years (2014-2023), 3 geographic levels (county, state, tract), 45 features Data Categories: - census: 30 features (e.g., asian population percentage, black population percentage, citizen voting age population percentage) - ejscreen: 3 features (e.g., P_DSLPM, P_PM25, P_PWDIS) - energyexpenditure: 12 features (e.g., Housing adjustment factor, Income adjustment factor, Monthly electricity cost)

AS↗