Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “customize”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Versatile semi-batch apparatus for manometric measurement of gas–solid reaction rates

In this study, we describe the design, construction, operation, and performance of a simple and versatile semi-batch reactor that is especially useful for measurement of gas/solid reaction rates at pressures in the range of 1 mTorr to 1500 Torr. The reactor operates by repeatedly imposing small AC modulations of reactant gas pressure on top of a much larger DC pressure background. Based on the rate of pressure relaxation following each AC pulse, the reaction rate is determined. Our design is characterized by modular construction from off-the-shelf, ultra-high-vacuum-compatible components, which facilitate easy retrofitting and adaptation to a range of experimental conditions. Automated experiment control and data acquisition is accomplished via a custom National Instruments © LabView virtual instrument. Data analysis is automated using a custom series of Mathworks © Matlab scripts. We demonstrate reactor performance through measurements of hydrogenation kinetics for a composite H 2 getter material consisting of 1,4-bis(phenylethynyl)benzene mixed with a palladium/carbon catalyst.

47 OTHER INSTRUMENTATION↗

The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors

We introduce a Xilinx RF System-on-Chip (RFSoC)-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short), which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC field-programmable gate array, custom firmware, and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average gate fidelity of ℱ avg =99.93%. All of the schematics, firmware, and software are open-source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate simulation of direct laser acceleration in a laser wakefield accelerator

In a laser wakefield accelerator (LWFA), an intense laser pulse excites a plasma wave that traps and accelerates electrons to relativistic energies. When the pulse overlaps the accelerated electrons, it can enhance the energy gain through direct laser acceleration (DLA) by resonantly driving the betatron oscillations of the electrons in the plasma wave. The traditional particle-in-cell (PIC) algorithm, although often the tool of choice to study DLA, contains inherent errors due to numerical dispersion and the time staggering of the electric and magnetic fields. Furthermore, conventional PIC implementations cannot reliably disentangle the fields of the plasma wave and laser pulse, which obscures interpretation of the dominant acceleration mechanism. Here, a customized field solver that reduces errors from both numerical dispersion and time staggering is used in conjunction with a field decomposition into azimuthal modes to perform PIC simulations of DLA in an LWFA. Comparisons with traditional PIC methods, model equations, and experimental data show improved accuracy with the customized solver and convergence with an order-of-magnitude fewer cells. Furthermore, the azimuthal-mode decomposition reveals that the most energetic electrons receive comparable energy from DLA and LWFA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wehnelt photoemission in an ultrafast electron microscope: Stability and usability

We tested and compared the stability and usability of three different cathode materials and configurations in a thermionic-based ultrafast electron microscope: (1) on-axis thermionic and photoemission from a custom 100 μm diameter LaB 6 source with a graphite guard ring, (2) off-axis photoemission from the Ni aperture surface of the Wehnelt electrode, and (3) on-axis thermionic and photoemission from a custom 200 μm diameter polycrystalline Ta source. For each cathode type and configuration, including the Ni Wehnelt aperture, we illustrate how the photoelectron beam-current stability is deleteriously impacted by simultaneous cooling of the source following thermionic heating. Furthermore, we demonstrate usability via collection of parallel- and convergent-beam electron diffraction patterns and by formation of the optimum probe size. We find that usability of the off-axis Ni Wehnelt-aperture photoemission is at least comparable to on-axis LaB 6 thermionic emission, as well as to on-axis photoemission [the heretofore conventional approach to ultrafast electron microscopy (UEM) in thermionic-based instruments]. However, the stability and achievable beam currents for off-axis photoemission from the Wehnelt aperture were superior to that of the other cathode types and configurations, regardless of the electron-emission mechanism. Beam-current stability for this configuration was found to be ±1% (one standard deviation from the mean) for 70 min (longest duration tested), and steady-state beam current was reached within the sampling-time resolution used here (~1 s) for 15 pA beam currents (i.e., 460 electrons per packet for a 200 kHz repetition rate). Repeatability and robustness of the steady-state condition were also found to be within ±1% of the mean. We discuss the implications of these findings for UEM imaging and diffraction experiments, for pulsed-beam damage measurements, and for practical switching between optimum conventional TEM and UEM operation within the same instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Proton radiation effects in indium oxide using cascade molecular dynamics simulations

Metal oxide (MO) semiconductors, characterized by their wide band gaps and notable charge transport properties, are promising candidates for electronic applications in extreme environments, including near-Earth space. However, atomistic simulations of radiation–matter interactions in MOs remain challenging due to the limitations of existing interatomic potentials, which often fail to capture both the short-range repulsive forces essential for radiation damage modeling and the long-range electrostatic effects governing defect evolution. In this work, we develop a customized interatomic potential tailored for radiation damage simulations in indium oxide (In 2 O 3 ) as a model system, a representative MO material. Our potential integrates the Ziegler-Biersack-Littmark potential to accurately describe short-range interactions with Buckingham and Coulombic potentials to account for long-range forces. We perform molecular dynamics simulations of low-energy proton irradiation using this custom potential. We employ the primary knock-on atom (PKA) cascade method to study atomic displacements and primary defect formation. Simulations were conducted for 1 keV proton irradiation in four randomly chosen directions, and PKA-driven defect analyses at 5, 10, and 15 keV to examine the effects of direction and energy level on damage generation. Our results provide insight into the impact of irradiation direction and energy level on the cascade evolution and defect formation mechanisms.

Atomistic simulations↗

Online purchasing creates opportunities to lower the life cycle carbon footprints of consumer products

Significance A major barrier to reducing greenhouse emissions from economic consumption involves information about product supply chains. Consumers who wish to reduce or offset the emissions embodied in goods and services they buy have no economical way to inform such choices. Vendors often can, but rarely do, gather embodied carbon information at little cost and offer it to consumers. They can also bundle carbon offsets for customers, thus facilitating choices. We report on a series of experiments using online interfaces to offer carbon footprint information and offset bundling in four sectors: online retailing, ride sharing, video streaming, and short-term lodging. Results indicate that firms can reduce their supply chains’ carbon footprints while improving customer satisfaction by facilitating consumers’ proenvironmental choices.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development and diagnosis of an atmospheric pressure plasma torch for investigating magnetohydrodynamic instabilities

The development and diagnosis of an atmospheric pressure, non-transferred, DC arc plasma torch for investigating magnetohydrodynamic experiments is presented. Utilizing a custom AC starter circuit coupled with a high power DC power supply a long, laminar plasma jet was successfully generated by adjusting voltage and current characteristics, gas flow rates, and torch geometry (nozzle diameter and length). A complete and detailed description of the design and operation conditions of our torch is presented such that our results may be reproduced. Utilizing copper, aluminum, and tungsten alloy electrode components in conjunction with an electrically isolated water cooling system allows for continuous torch operation. The 50 kV AC starter circuit is coupled with a 15 kW DC power supply via a series injection transformer as a part of the custom arc starter circuit components. Axial and tangential gas flow, with nitrogen as the working gas, is regulated to generate a stable, laminar, atmospheric plasma torch with a jet length of over 80 cm under ideal operating conditions. Here, to visualize the plasma interface in magnetohydrodynamics experiments, a technique was developed to image the cylindrical plasma jet in both the R-Z plane (axial) and R-θ plane (cross sectional) using planar-laser Mie scattering from particles added to the surrounding gas. Plasma emission wavelengths are filtered out allowing scattered light from the particle laden-flow field illuminated at 532 nm by an Nd:YAG laser, to be isolated. Plasma electron temperature and degree of ionization were estimated using a technique based on the well-known Fowler–Milne spectroscopic method. Electron temperatures of up to 14 000 K and degree of ionization up to 27% at the torch exit were obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mathematical solutions in internal dose assessment: A comparison of Python-based differential equation solvers in biokinetic modeling

Abstract In biokinetic modeling systems employed for radiation protection, biological retention and excretion have been modeled as a series of discretized compartments representing the organs and tissues of the human body. Fractional retention and excretion in these organ and tissue systems have been mathematically governed by a series of coupled first-order ordinary differential equations (ODEs). The coupled ODE systems comprising the biokinetic models are usually stiff due to the severe difference between rapid and slow transfers between compartments. In this study, the capabilities of solving a complex coupled system of ODEs for biokinetic modeling were evaluated by comparing different Python programming language solvers and solving methods with the motivation of establishing a framework that enables multi-level analysis. The stability of the solvers was analyzed to select the best performers for solving the biokinetic problems. A Python-based linear algebraic method was also explored to examine how the numerical methods deviated from an analytical or semi-analytical method. Results demonstrated that customized implicit methods resulted in an enhanced stable solution for the inhaled 60 Co (Type M) and 131 I (Type F) exposure scenarios for the inhalation pathway of the International Commission on Radiological Protection (ICRP) Publication 130 Human Respiratory Tract Model (HRTM). The customized implementation of the Python-based implicit solvers resulted in approximately consistent solutions with the Python-based matrix exponential method ( expm ). The differences generally observed between the implicit solvers and expm are attributable to numerical precision and the order of numerical approximation of the numerical solvers. This study provides the first analysis of a list of Python ODE solvers and methods by comparing their usage for solving biokinetic models using the ICRP Publication 130 HRTM and provides a framework for the selection of the most appropriate ODE solvers and methods in Python language to implement for modeling the distribution of internal radioactivity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Hardware, methodology and applications of 2 + D backscatter Mössbauer spectroscopy with simultaneous x-ray and γ-ray detection

Abstract A unique method is presented for the acquisition and analysis of 57 Fe backscatter Mössbauer spectra with simultaneous detection of the resonant 14.4 keV γ -rays and the characteristic 6.4 keV x-rays, using a custom-built multi-parameter analyser constructed on the basis of commercial analogue to digital converters and high-speed digital latches. The system allows for the simultaneous registration of Doppler-modulation velocities and photon energies, with up to 4096 and 8192 digital channels respectively. This arrangement is in contrast to most related systems, which detect at a single narrow energy window per detector. Samples of arbitrary atomic structure, morphology and surface topography can be studied without altering the setup or the analysis procedure, provided that the samples are at least micrometre sized. The hardware and software that are used to acquire data with minimal dead time are described and the custom and self-contained methods for post-measurement energy discrimination, background correction and velocity-axis folding are discussed. The data are fit using a general Hamiltonian model for the nuclear energy levels of 57 Fe and a quantum mechanical description of the angular momentum coupling is utilised, with consideration of the crystalline and chemical disorder of the sample under examination. Three examples of distinct magnetic systems, with thicknesses ranging from 5 μ m to 6 mm, that were studied using this method are presented, these are: an amorphous CoFeB-based ribbon with ultra-soft coercivity for high-frequency applications, magnetically hard Nd-Fe-B thick films on Si substrates, examined in both as-deposited and annealed states, and a sample from the nickel-rich iron meteorite NWA 6259 that contains the atomically ordered, elevated coercivity, L 1 0 phase of FeNi, tetrataenite. The wide applicability and usefulness of this method is thus demonstrated on three distinct sample morphologies that required little to no surface preparation prior to examination.

Engineering↗

Design improvements to cables and connectors in the Majorana Demonstrator

The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76 Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radio purity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. In conclusion, we will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.

42 ENGINEERING↗

FELIX: a PCIe based high-throughput approach for interfacing front-end and trigger electronics in the ATLAS Upgrade framework

The ATLAS Phase-I upgrade (2019) requires a Trigger and Data Acquisition (TDAQ) system able to trigger and record data from up to three times the nominal LHC instantaneous luminosity. Furthermore, the Front-End LInk eXchange (FELIX) system provides an infrastructure to achieve this in a scalable, detector agnostic and easily upgradeable way. It is a PC-based gateway, interfacing custom radiation tolerant optical links from front-end electronics, via PCIe Gen3 cards, to a commodity switched Ethernet or InfiniBand network. FELIX enables reducing custom electronics in favour of software running on commercial servers. Here, the FELIX system, the design of the PCIe prototype card and the integration test results are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The electronics and data acquisition system for the DarkSide-50 veto detectors

DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles. It utilizes a liquid argon time projection chamber for the inner main detector, surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors. The system is made of a custom built front end electronics and commercial National Instruments high speed digitizers. The front end electronics, the DAQ, and the trigger system have been used to acquire data in the form of zero-suppressed waveform samples from the 110 PMTs of the LSV and the 80 PMTs of the WCV. The veto DAQ system has proven its performance and reliability. This electronics and DAQ system can be scaled and used as it is for the veto of the next generation DarkSide-20k detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of SiPM-based readout of PbF 2 crystals for high-rate, precision timing applications

Here, we have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The calorimeter absorber is an array of lead-fluoride crystals, which produces short-duration Cherenkov light. The detector sits in the high magnetic field of the muon storage ring. The SiPMs selected, and their accompanying custom electronics, must preserve the short pulse shape, have high quantum efficiency, be non-magnetic, exhibit gain stability under varying rate conditions, and cover a fairly large fraction of the crystal exit surface area. We describe an optimized design that employs the new-generation of thru-silicon via devices. As a result, the performance is documented in a series of bench and beam tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DAQ and control system for the CMS Phase-1 pixel detector upgrade

In 2017 a new pixel detector was installed in the CMS detector. This so-called Phase-1 pixel detector features four barrel layers in the central region and three disks per end in the forward regions. The upgraded pixel detector requires an upgraded data acquisition (DAQ) system to accept a new data format and larger event sizes. A new DAQ and control system has been developed based on a combination of custom and commercial microTCA parts. Custom mezzanine cards on standard carrier cards provide a front-end driver for readout, and two types of front-end controller for configuration and the distribution of clock and trigger signals. Before the installation of the detector the DAQ system underwent a series of integration tests, including readout of the pilot pixel detector, which was constructed with prototype Phase-1 electronics and operated in CMS from 2015 to 2016, quality assurance of the CMS Phase-1 detector during its assembly, and testing with the CMS Central DAQ. This paper describes the Phase-1 pixel DAQ and control system, along with the integration tests and results. A description of the operational experience and performance in data taking is included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production and testing of the powerboard for ATLAS ITk Strip barrel modules

The upgrade of the ATLAS ITk strips detector for HL-LHC will employ a custom PCB (powerboard) for on-module DC-DC conversion, HV switching, and monitoring. Production of about 14100 of such PCBs with high reliability is a big challenge. In this paper we will present the production procedure and quality control (QC) testing system for the powerboards to be installed on ITk Strip barrel modules. During production, about 150 powerboards will be produced every week. Each powerboard will need to pass QC tests before they are assembled to module. The QC tests include thermal cycling between -35 °C and 40 °C, soak test (continuous running of DC-DC converter at high load at 20 °C), and basic functionality and characterization electrical tests of the low voltage (LV), high voltage (HV), and monitoring functions of the powerboard. A custom QC test system is described, which is based on a reusable PCB (active board) with all testing circuits, a one-time powerboard carrier card, and a Z-turn SoC board which hosts and runs the testing program. The production procedure and QC test system has been tested with 400 powerboards during pre-production, and the system has been proven ready for production with the desired testing program, speed, safety, and cost. Performance and typical failures of powerboards observed during the QC test of pre-production powerboards is also presented.

47 OTHER INSTRUMENTATION↗

The COLUTA ADC ASIC and the ATLAS HL-LHC Liquid Argon Front-End Readout

Abstract The upgraded High-Luminosity Large Hadron Collider (HL-LHC) requires a new radiation tolerant ATLAS Liquid Argon (LAr) Calorimeter readout operating at 40 MHz with 16-bit dynamic range. The Front-End Board 2 (FEB2) will provide the front-end readout for the calorimeter, and will interface a series of custom ASICs due to radiation tolerance requirements of the HL-LHC. The COLUTA is a 65 nm CMOS custom 8-channel 15-bit 40 MSPS ADC ASIC developed for this application. This contribution will present performance results of the final prototype of the COLUTA, surpassing specifications at >11.5 ENOB for relevant frequencies, as well as non-linearity and radiation requirements. Preliminary integration results of the front-end readout components will also be described by means of the FEB2 Pre-Prototype, the “Slice Testboard”.

Instruments & Instrumentation↗

Smart pixel sensors: towards on-sensor filtering of pixel clusters with deep learning

Highly granular pixel detectors allow for increasingly precise measurements of charged particle tracks. Next-generation detectors require that pixel sizes will be further reduced, leading to unprecedented data rates exceeding those foreseen at the High- Luminosity Large Hadron Collider. Signal processing that handles data incoming at a rate of $\mathcal{O}$(40 MHz) and intelligently reduces the data within the pixelated region of the detector at rate will enhance physics performance at high luminosity and enable physics analyses that are not currently possible. Using the shape of charge clusters deposited in an array of small pixels, the physical properties of the traversing particle can be extracted with locally customized neural networks. In this first demonstration, we present a neural network that can be embedded into the on-sensor readout and filter out hits from low momentum tracks, reducing the detector's data volume by 57.1%–75.7%. The network is designed and simulated as a custom readout integrated circuit with 28 nm CMOS technology and is expected to operate at less than 300 μW with an area of less than 0.2 mm 2 . The temporal development of charge clusters is investigated to demonstrate possible future performance gains, and there is also a discussion of future algorithmic and technological improvements that could enhance efficiency, data reduction, and power per area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SymbolNet: neural symbolic regression with adaptive dynamic pruning for compression

Abstract Compact symbolic expressions have been shown to be more efficient than neural network (NN) models in terms of resource consumption and inference speed when implemented on custom hardware such as field-programmable gate arrays (FPGAs), while maintaining comparable accuracy (Tsoi et al 2024 EPJ Web Conf. 295 09036). These capabilities are highly valuable in environments with stringent computational resource constraints, such as high-energy physics experiments at the CERN Large Hadron Collider. However, finding compact expressions for high-dimensional datasets remains challenging due to the inherent limitations of genetic programming (GP), the search algorithm of most symbolic regression (SR) methods. Contrary to GP, the NN approach to SR offers scalability to high-dimensional inputs and leverages gradient methods for faster equation searching. Common ways of constraining expression complexity often involve multistage pruning with fine-tuning, which can result in significant performance loss. In this work, we propose S y m b o l N e t , a NN approach to SR specifically designed as a model compression technique, aimed at enabling low-latency inference for high-dimensional inputs on custom hardware such as FPGAs. This framework allows dynamic pruning of model weights, input features, and mathematical operators in a single training process, where both training loss and expression complexity are optimized simultaneously. We introduce a sparsity regularization term for each pruning type, which can adaptively adjust its strength, leading to convergence at a target sparsity ratio. Unlike most existing SR methods that struggle with datasets containing more than O ( 10 ) inputs, we demonstrate the effectiveness of our model on the LHC jet tagging task (16 inputs), MNIST (784 inputs), and SVHN (3072 inputs).

Tsoi, Ho Fung (ORCID:0000000225502184)↗