Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Tritium permeation characterization of materials for fusion and generation IV very high temperature reactors

The objective of this work is to establish the tritium-permeation properties of structural alloys considered for Fusion systems and very high temperature reactors (VHTR). A description of the work performed to set up an apparatus to measure permeation rates of hydrogen and tritium in 304L stainless steel is presented. Following successful commissioning with hydrogen, the test apparatus was commissioned with tritium. Commissioning tests with tritium suggest the need for a reduction step that is capable of removing the oxide layer from the test sample surfaces before accurate tritium-permeation data can be obtained. Work is also on-going to clearly establish the temperature profile of the sample to correctly estimate the tritium-permeability data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The metric of the cosmos from luminosity and age data

This paper presents the algorithm for determining the Lemaître-Tolman model that best fits given datasets for maximum stellar ages, and SNIa luminosities, both as functions of redshift. It then applies it to current cosmological data. Special attention must be given to the handling of the origin, and the region of the maximum diameter distances. As with a previous combination of datasets (galaxy number counts and luminosity distances versus redshift), there are relationships that must hold at the region of the maximum diameter distance, which are unlikely to be obeyed exactly by real data. We show how to make corrections that enable a self-consistent solution to be found. We address the questions of the best way to approximate discrete data with smooth functions, and how to estimate the uncertainties of the output — the 3 free functions that determine a specific Lemaître-Tolman metric. While current data does not permit any confidence in our results, we show that the method works well, and reasonable Lemaître-Tolman models do fit with or without a cosmological constant.

79 ASTRONOMY AND ASTROPHYSICS↗

An analysis of the nucleon spectrum from lattice partially-quenched QCD.

The chiral extrapolation of the nucleon mass, M{sub n}, is investigated using data coming from 2-flavour partially-quenched lattice simulations. A large sample of lattice results from the CP-PACS Collaboration is analysed using the leading one-loop corrections, with explicit corrections for finite lattice spacing artifacts. The extrapolation is studied using finite-range regularised chiral perturbation theory. The analysis also provides a quantitative estimate of the leading finite volume corrections. It is found that the discretisation, finite volume and partial quenching effects can all be very well described in this framework, producing an extrapolated value of Mn in agreement with experiment. Furthermore, determinations of the low energy constants of the nucleon mass's chiral expansion are in agreement with previous methods, but with significantly reduced errors. This procedure is also compared with extrapolations based on polynomial forms, where the results are less encouraging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine Learning Potentials with the Iterative Boltzmann Inversion: Training to Experiment

Methodologies for training machine learning potentials (MLPs) with quantum-mechanical simulation data have recently seen tremendous progress. Experimental data have a very different character than simulated data, and most MLP training procedures cannot be easily adapted to incorporate both types of data into the training process. Here, we investigate a training procedure based on iterative Boltzmann inversion that produces a pair potential correction to an existing MLP using equilibrium radial distribution function data. By applying these corrections to an MLP for pure aluminum based on density functional theory, we observe that the resulting model largely addresses previous overstructuring in the melt phase. Interestingly, the corrected MLP also exhibits improved performance in predicting experimental diffusion constants, which are not included in the training procedure. The presented method does not require autodifferentiating through a molecular dynamics solver and does not make assumptions about the MLP architecture. Our results suggest a practical framework for incorporating experimental data into machine learning models to improve the accuracy of molecular dynamics simulations.

36 MATERIALS SCIENCE↗

Photorefractive Correction of the Coupling Ratio of an Integrated Optical Directional X-Coupler on a Lithium Niobate Substrate

The possibility of correcting the power coupling ratio of an integrated optical directional X-coupler upon excitation of a local photorefractive response in the substrate material (LiNbO{sub 3}) has been analyzed. The X-coupler operation has been numerically simulated, and the regions of its maximum sensitivity to photorefraction have been determined. The correspondence between the calculated and experimental data has been obtained. The maximum correction value of the coupling ratio is 1–2%. The photorefractive correction of the coupling ratio has been used to increase the extinction ratio of a Mach–Zehnder modulator to 47 dB.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Raw tensiometer soil matric potential data, from Oct 2017-Jun 2020 in Manaus, Brazil

This data package contains raw output from two Campbell Scientific CR1000 data loggers each connected to three UMS T4e tensiometer sensors in Manaus, Brazil. Tensiometers at each data logger location were installed to depths of 10 cm, 20 cm and 50 cm below the ground surface for the purpose of measuring soil matric potential at each depth. “Station 3” tensiometers were installed at approximately 2°36'31.68"S, 60°12'34.70"W. “Station 4” tensiometers were installed at approximately 2°36'32.46"S, 60°12'34.92"W. The files “tensio3.edit.202109.csv” and “tensio4.edit.202109.csv” contain raw data (with invalid data removed). A text editor will be required to view the raw files in .csv (comma-separated values) format. Data processing was limited to: 1) Editing column headers for clarity; 2) Applying a correction that converts voltage read by the data loggers to pressure units (kPa); 3) removing all data greater than 50 kPa and less than -115 kPa; 4) Adding columns entitled “Caution.10cm”, “Caution.20cm” and “Caution.50cm” that contains values of either “NA” or “Caution”, the latter of which is applied when data exceeds the manufacturer reported data validity range of less than -85 kPa to suggest use of these data with caution; 5) Adding columns entitled “Invalid.10cm”, “Invalid.20cm”, and “Invalid.50cm” that contains values of either “NA” or “Invalid”, the latter of which is applied when data accuracy is deemed compromised due to the introduction of air bubbles into the instrument. Data marked “Invalid” may still indicate general trends of wet/high matric potential and dry/low matric potential, but values are inaccurate and dry/low matric potential values are likely not low enough. Wet/high matric potential values are likely to be more accurate than dry/low matric potential values; 6) Data format changed from .dat to .csv. This research was performed as a part of the NGEE Tropics project, which aims to advance model predictions of tropical forest carbon cycle responses to a changing climate over the 21st Century.

54 ENVIRONMENTAL SCIENCES↗

NCAR/EOL ISFS Data for LASSO-CACTI Overview Paper

5 minute averages of surface meteorology and flux data collected by the NCAR/EOL Integrated Surface Flux System (ISFS) at 15 sites during the RELAMPAGO field campaign. These data have been quality-controlled and are available in NetCDF format. Winds reported by the sonic anemometers have been tilt corrected and rotated into geographic coordinates. Data providence, citation, and acknowledgement This ARM data set is a copy of v2.0 of the NCAR data set obtained on 6-Jun-2024 from https://doi.org/10.26023/ZPHJ-JW9W-2B0Y. The citation for the original data source is: NCAR/EOL In-situ Sensing Facility, Oncley, S. 2021. NCAR/EOL ISFS Surface Meteorology and Flux Products, 5-minute. Version 2.0. UCAR/NCAR - Earth Observing Laboratory. https://doi.org/10.26023/ZPHJ-JW9W-2B0Y Accessed 06 Jun 2024. In addition to the citation reference and any other acknowledgements, please acknowledge NCAR/EOL in your publications with text such as: "Data provided by NCAR/EOL under the sponsorship of the National Science Foundation. https://data.eol.ucar.edu/"

atmosphere: surface↗

Modeling and evaluating 239 Pu and 235 U PFNS and average prompt-neutron multiplicity [Slides]

The following are currently in VIII.1 LANL and IAEA test files: 239 Pu nu-bar including CGMF modeling and CEA data, 239 Pu PFNS including Chi-Nu & CEA data, 239 Pu(n,f) cross section including fission TPC data. The following are currently being tested: 235 U nu-bar including CGMF modeling and 235 U PFNS including Chi-Nu data. Upcoming tasks include the correction of 235 U Chi-Nu PFNS at higher E inc , benchmarking 235 U PFNS and nu-bar evaluations, and getting 238 U nu-bar.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Molecular mechanism of crystallization impacting calcium phosphate cements

In summary, SPM data has shown that (1) Mg inhibits growth on all steps but relatively high Mg/Ca ratios are needed. Extracting the mechanism of interaction requires more modeling of the kinetic data, but step morphology is consistent with incorporation. (2) Citrate has several effects depending on the citrate/Ca ratio. At the lowest concentrations, citrate increases the step free energy without altering the step kinetics; at higher concentrations, the polar step is slowed. (3) Oxalate also slows the polar step but additionally stabilizes a new facet, with a [100]{sub Cc} step. (4) Etidronate has the greatest kinetic impact of the molecules studied. At 7{micro}M concentrations, the polar step slows by 60% and a new polar step appears. However, at the same time the [10-1]{sub Cc} increases by 67%. It should be noted that all of these molecules complex calcium and can effect kinetics by altering the solution supersaturation or the Ca to HPO{sub 4}{sup 2-} ratio. For the SPM data shown, this effect was corrected for to distinguish the effect of the molecule at the crystal surface from the effect of the molecule on the solution speciation. The goal of this paper is to draw connections between fundamental studies of atomic step motion and potential strategies for materials processing. It is not our intent to promote the utility of SPM for investigating processes in cement dynamics. The conditions are spectacularly different in many ways. The data shown in this paper are fairly close to equilibrium (S=1.6) whereas the nucleation of cements is initiated at supersaturation ratios in the thousands to millions. Of course, after the initial nucleation phase, the growth will occur at more modest supersaturations and as the cement evolves towards equilibrium certainly some of the growth will occur in regimes such as shown here. In addition to the difference in supersaturation, cements tend to have lower additive to calcium ratios. As an example, the additive to Ca ratio is {approx}10{sup -3} to 10{sup -4} for a pyrophosphate based cement (Grover et al., 2006). Where the in situ SPM approach provides unique insights is in providing details of where and how molecules inhibit or accelerate kinetics. This has the potential to aid in designing molecules to target specific steps and to guide synergistic combinations of additives. For example, it is unlikely that bulk techniques could deduce the simultaneous acceleration and inhibition effects of etidronate; or that citrate reduced growth rate by altering step density rather than step speed. In addition, SPM data translates to tractable questions for modelers. The questions changes from 'How does etidronate inhibit brushite growth?' to 'Why does etidronate bind strongly to the [101]{sub Cc} step while it doesn't to the [10-1]{sub Cc} step?' This is still a challenging question but it is far better defined. Given that step chemistries are generally different, it seems reasonable to expect that the greatest inhibition will be achieved not with one, but with several synergistically chosen additives. For example, the most effective growth inhibitors for brushite would target the two fast steps, namely the non-polar, [10-1]{sub Cc} and the polar, [101]{sub Cc} steps. Several molecules have been shown to slow the polar step, with etidronate as the most dramatic example. By contrast, only Mg was observed to slow the [10-1]{sub Cc} step. Thus, a combination of high concentrations of Mg to target the [10-1]{sub Cc} step with low concentrations of etidronate to target the polar steps, should be a more effective combination than either alone. However Mg is not a particularly good inhibitor in the sense that high concentrations are needed, and it is not specific. More ideally, an inhibitor would be designed to interact specifically with the [10-1] step, which would allow the two steps to be independently modified. Again, this provides an opportunity for tighter coupling with theoretical modeling. The question changes from 'What types of molecules will inhibit brushite growth' to 'What type of molecule will interact with the [10-1]{sub Cc} step?' Similarly, to increase resorption rate, it would be most efficacious to target the slow moving [-100] step, perhaps by targeting the hydroxyl group which seem to stabilize this step compared to its otherwise similar mirror, [100]. In short, there are a number of opportunities where molecular scale imaging can provide new information that has the prospect to aid in optimizing calcium phosphate cements.

36 MATERIALS SCIENCE↗

Brain necrosis after fractionated radiation therapy: Is the halftime for repair longer than we thought?

Purpose: To derive a radiobiological model that enables the estimation of brain necrosis and spinal cord myelopathy rates for a variety of fractionation schemes, and to compare repair effects between brain and spinal cord. Methods: Sigmoidal dose response relationships for brain radiation necrosis and spinal cord myelopathy are derived from clinical data using nonlinear regression. Three different repair models are considered and the repair halftimes are included as regression parameters. Results: For radiation necrosis, a repair halftime of 38.1 (range 6.9-76) h is found with monoexponential repair, while for spinal cord myelopathy, a repair halftime of 4.1 (range 0-8) h is found. The best-fit alpha beta ratio is 0.96 (range 0.24-1.73)Conclusions: A radiobiological model that includes repair corrections can describe the clinical data for a variety of fraction sizes, fractionation schedules, and total doses. Modeling suggests a relatively long repair halftime for brain necrosis. This study suggests that the repair halftime for late radiation effects in the brain may be longer than is currently thought. If confirmed in future studies, this may lead to a re-evaluation of radiation fractionation schedules for some CNS diseases, particularly for those diseases where fractionated stereotactic radiation therapy is used.

60 APPLIED LIFE SCIENCES↗

A Lyapunov Function Based Remedial Action Screening Tool Using Real-Time Data

This report summarizes the outcome of a research project that comprised the development of a Lyapunov function based remedial action screening tool using real-time data (L-RAS). The L-RAS is an advanced computational tool that is intended to assist system operators in making real-time redispatch decisions to preserve power grid stability. The tool relies on screening contingencies using a homotopy method based on Lyapunov functions to avoid, to the extent possible, the use of time domain simulations. This enables transient stability evaluation at real-time speed without the use of massively parallel computational resources. The project combined the following components. 1. Development of a methodology for contingency screening using a homotopy method based on Lyapunov functions and real-time data. 2. Development of a methodology for recommending remedial actions based on the screening results. 3. Development of a visualization and operator interaction interface. 4. Testing of screening tool, validation of control actions, and demonstration of project outcomes on a representative real system simulated on a Real-Time Digital Simulator (RTDS) cluster. The project was led by Michigan State University (MSU), where the theoretical models including homotopy-based screening, trajectory correction using real-time data, and remedial action were developed and implemented in the form of research-grade software. Los Alamos National Laboratory (LANL) contributed to the development of energy margin sensitivity dynamics, which constituted a part of the remedial action portfolio. Florida State University (FSU) and Southern California Edison (SCE) developed a model of the SCE system that was implemented on FSU's RTDS cluster to simulate real-time data that was streamed over the internet to MSU where the L-RAS tool was executed and remedial actions were communicated back to FSU to execute stabilizing controls on the simulated system. LCG Consulting developed the visualization and operator interaction interface, based on specifications provided by MSU. The project was performed from October 2012 to December 2016, at the end of which the L-RAS tool, as described above, was completed and demonstrated. The project resulted in the following innovations and contributions: (a) the L-RAS software prototype, tested on a simulated system, vetted by utility personnel, and potentially ready for wider testing and commercialization; (b) an RTDS-based test bed that can be used for future research in the field; (c) a suite of breakthrough theoretical contributions to the field of power system stability and control; and (d) a new tool for visualization of power system stability margins. While detailed descriptions of the development and implementation of the various project components have been provided in the quarterly reports, this final report provides an overview of the complete project, and is demonstrated using public domain test systems commonly used in the literature. The SCE system, and demonstrations thereon, are not included in this report due to Critical Energy Infrastructure Information (CEII) restrictions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast BPM data distribution for global orbit feedback using commercial gigabit ethernet technology

In order to correct beam perturbations in RHIC around 10Hz, a new fast data distribution network was required to deliver BPM position data at rates several orders of magnitude above the capability of the existing system. The urgency of the project limited the amount of custom hardware that could be developed, which dictated the use of as much commercially available equipment as possible. The selected architecture uses a custom hardware interface to the existing RHIC BPM electronics together with commercially available Gigabit Ethernet switches to distribute position data to devices located around the collider ring. Using the minimum Ethernet packet size and a field programmable gate array (FPGA) based state machine logic instead of a software based driver, real-time and deterministic data delivery is possible using Ethernet. The method of adapting this protocol for low latency data delivery, bench testing of Ethernet hardware, and the logic to construct Ethernet packets using FPGA hardware will be discussed. A robust communications system using almost all commercial off-the-shelf equipment was developed in under a year which enabled retrofitting of the existing RHIC BPM system to provide 10 KHz data delivery for a global orbit feedback scheme using 72 BPMs. Total latencies from data acquisition at the BPMs to delivery at the controller modules, including very long transmission distances, were kept under 100 {micro}s, which provide very little phase error in correcting the 10 Hz oscillations. Leveraging off of the speed of Gigabit Ethernet and wide availability of Ethernet products enabled this solution to be fully implemented in a much shorter time and at lower cost than if a similar network was developed using a proprietary method.

43 PARTICLE ACCELERATORS↗

Dosimetric influences of rotational setup errors on head and neck carcinoma intensity-modulated radiation therapy treatments

The purpose of this work is to investigate the dosimetric influence of the residual rotational setup errors on head and neck carcinoma (HNC) intensity-modulated radiation therapy (IMRT) with routine 3 translational setup corrections and the adequacy of this routine correction. A total of 66 kV cone beam computed tomography (CBCT) image sets were acquired on the first day of treatment and weekly thereafter for 10 patients with HNC and were registered with the corresponding planning CT images, using 2 3-dimensional (3D) rigid registration methods. Method 1 determines the translational setup errors only, and method 2 determines 6-degree (6D) setup errors, i.e., both rotational and translational setup errors. The 6D setup errors determined by method 2 were simulated in the treatment planning system and were then corrected using the corresponding translational data determined by method 1. For each patient, dose distributions for 6 to 7 fractions with various setup uncertainties were generated, and a plan sum was created to determine the total dose distribution through an entire course and was compared with the original treatment plan. The average rotational setup errors were 0.7°± 1.0°, 0.1°±1.9°, and 0.3°±0.7° around left-right (LR), anterior-posterior (AP), and superior-inferior (SI) axes, respectively. With translational corrections determined by method 1 alone, the dose deviation could be large from fraction to fraction. For a certain fraction, the decrease in prescription dose coverage (V{sub p}) and the dose that covers 95% of target volume (D{sub 95}) could be up to 15.8% and 13.2% for planning target volume (PTV), and the decrease in V{sub p} and the dose that covers 98% of target volume (D{sub 98}) could be up to 9.8% and 5.5% for the clinical target volume (CTV). However, for the entire treatment course, for PTV, the plan sum showed that the average V{sub p} was decreased by 4.2% and D{sub 95} was decreased by 1.2 Gy for the first phase of IMRT with a prescription dose of 50 Gy. For CTV, the plan sum showed that the average V{sub p} was decreased by 0.8% and D{sub 98}, relative to prescription dose, was not decreased. Among these 10 patients, the plan sum showed that the dose to 1-cm{sup 3} spinal cord (D{sub 1cm{sup 3}}) increased no more than 1 Gy for 7 patients and more than 2 Gy for 2 patients. The average increase in D{sub 1cm{sup 3}} was 1.2 Gy. The study shows that, with translational setup error correction, the overall CTV V{sub p} has a minor decrease with a 5-mm margin from CTV to PTV. For the spinal cord, a noticeable dose increase was observed for some patients. So to decide whether the routine clinical translational setup error correction is adequate for this HNC IMRT technique, the dosimetric influence of rotational setup errors should be evaluated carefully from case to case when organs at risk are in close proximity to the target.

61 RADIATION PROTECTION AND DOSIMETRY↗

General Purpose Graphics Processing Unit Based High-Rate Rice Decompression and Reed-Solomon Decoding

As the volume of data acquired by space-based sensors increases, mission data compression/decompression and forward error correction code processing performance must likewise scale. This competency development effort was explored using the General Purpose Graphics Processing Unit (GPGPU) to accomplish high-rate Rice Decompression and high-rate Reed-Solomon (RS) decoding at the satellite mission ground station. Each algorithm was implemented and benchmarked on a single GPGPU. Distributed processing across one to four GPGPUs was also investigated. The results show that the GPGPU has considerable potential for performing satellite communication Data Signal Processing, with three times or better performance improvements and up to ten times reduction in cost over custom hardware, at least in the case of Rice Decompression and Reed-Solomon Decoding.

97 MATHEMATICS AND COMPUTING↗

Effects of Respiration-Averaged Computed Tomography on Positron Emission Tomography/Computed Tomography Quantification and its Potential Impact on Gross Tumor Volume Delineation

Purpose: Patient respiratory motion can cause image artifacts in positron emission tomography (PET) from PET/computed tomography (CT) and change the quantification of PET for thoracic patients. In this study, respiration-averaged CT (ACT) was used to remove the artifacts, and the changes in standardized uptake value (SUV) and gross tumor volume (GTV) were quantified. Methods and Materials: We incorporated the ACT acquisition in a PET/CT session for 216 lung patients, generating two PET/CT data sets for each patient. The first data set (PET{sub HCT}/HCT) contained the clinical PET/CT in which PET was attenuation corrected with a helical CT (HCT). The second data set (PET{sub ACT}/ACT) contained the PET/CT in which PET was corrected with ACT. We quantified the differences between the two datasets in image alignment, maximum SUV (SUV{sub max}), and GTV contours. Results: Of the patients, 68% demonstrated respiratory artifacts in the PET{sub HCT}, and for all patients the artifact was removed or reduced in the corresponding PET{sub ACT}. The impact of respiration artifact was the worst for lesions less than 50 cm{sup 3} and located below the dome of the diaphragm. For lesions in this group, the mean SUV{sub max} difference, GTV volume change, shift in GTV centroid location, and concordance index were 21%, 154%, 2.4 mm, and 0.61, respectively. Conclusion: This study benchmarked the differences between the PET data with and without artifacts. It is important to pay attention to the potential existence of these artifacts during GTV contouring, as such artifacts may increase the uncertainties in the lesion volume and the centroid location.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Moderate spectral resolution solar irradiance measurements, aerosol optical depth, and solar transmission, from 360 to 1070 nm, using the refurbished rotating shadow band spectroradiometer (RSS)

Abstract. This paper reports on a third-generation rotating shadow band spectroradiometer (RSS) used to measure global and diffuse horizontal plus direct normal irradiances and transmissions at 1002 wavelengths between 360 and 1070 nm. The prism-dispersed spectral data are from the Atmospheric Radiation Measurement (ARM) Southern Great Plains site in north-central Oklahoma (36.605∘ N, 97.486∘ W) and cover dates between August 2009 and February 2014. The refurbished RSS isolates the detector in a vacuum chamber with pressures near 10−7 torr. This prevents the deposition of outgassed vapors from the interior of the spectrometer shell on the cooled detector that affected the operation of the first commercial RSS. Methods for (1) ensuring the correct wavelength registration of the data and (2) deriving extraterrestrial responses over the entire spectrum, including throughout strong water vapor and oxygen bands, are described. The resulting data produced are archived as ARM data records and include cloud-screened aerosol optical depths, spectral irradiances and direct normal solar transmission, as well as normalized diffuse and global irradiances.

54 ENVIRONMENTAL SCIENCES↗

ULTRAVIOLET LIGHT CURVES OF SUPERNOVAE WITH THE SWIFT ULTRAVIOLET/OPTICAL TELESCOPE

We present ultraviolet (UV) observations of supernovae (SNe) obtained with the UltraViolet/Optical Telescope (UVOT) on board the Swift spacecraft. This is the largest sample of UV light curves from any single instrument and covers all major SN types and most subtypes. The UV light curves of SNe Ia are fairly homogenous, while SNe Ib/c and IIP show more variety in their light-curve shapes. The UV-optical colors clearly differentiate SNe Ia and IIP, particularly at early times. The color evolution of SNe IIP, however, makes their colors similar to SNe Ia at about 20 days after explosion. SNe Ib/c are shown to have varied UV-optical colors. The use of UV colors to help type SNe will be important for high-redshift SNe discovered in optical observations. These data can be added to ground-based optical and near infrared data to create bolometric light curves of individual objects and as checks on generic bolometric corrections used in the absence of UV data. This sample can also be compared with rest-frame UV observations of high-redshift SNe observed at optical wavelengths.

79 ASTRONOMY AND ASTROPHYSICS↗

Analytical effects on clumped isotope thermometry: Comparison of a common sample set analyzed using multiple instruments, types of standards, and standardization windows

Carbonate clumped isotope geothermometry is being increasingly used in multiple disciplines in the geosciences. However, potential interlaboratory issues are arising from different standardization procedures that may contribute to the multiple Δ 47 -temperature calibrations reported in the literature. We investigate this issue by comparing a common temperature calibration sample set across three different mass spectrometers, using multiple standardization methods. The same temperature calibration sample set was analyzed on three different mass spectrometers. Several standardization methods were utilized, including the use of carbonate versus gas standards, and different types of background correction were applied to the raw data. All standardization types applied resulted in statistically indistinguishable Δ 47 -temperature slopes, with the exception of standardization calculations that did not correct for background effects. Some instruments and standardizations showed different intercepts relative to each other. The use of carbonate standards improved comparability between different instruments relative to gas standards. Our results show that background effects are the largest factor potentially affecting Δ 47 results, and there may be an improvement in interlaboratory precision using carbonate standards. Critically, all techniques used for standardizing Δ 47 results converge on a common slope as long as background effects are properly corrected. The use of carbonate standards is recommended as a component of standardization procedures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗