Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Experimental Studies of NGNP Reactor Cavity Cooling System With Water

This project will investigate the flow behavior that can occur in the reactor cavity cooling system (RCCS) with water coolant under the passive cooling-mode of operation. The team will conduct separate-effects tests and develop associated scaling analyses, and provide system-level phenomenological and computational models that describe key flow phenomena during RCCS operation, from forced to natural circulation, single-phase flow and two-phase flow and flashing. The project consists of the following tasks: Task 1. Conduct separate-effects, single-phase flow experiments and develop scaling analyses for comparison to system-level computational modeling for the RCCS standpipe design. A transition from forced to natural convection cooling occurs in the standpipe under accident conditions. These tests will measure global flow behavior and local flow velocities, as well as develop instrumentation for use in larger scale tests, thereby providing proper flow distribution among standpipes for decay heat removal. Task 2. Conduct separate-effects experiments for the RCCS standpipe design as two-phase flashing occurs and flow develops. As natural circulation cooling continues without an ultimate heat sink, water within the system will heat to temperatures approaching saturation , at which point two-phase flashing and flow will begin. The focus is to develop a phenomenological model from these tests that will describe the flashing and flow stability phenomena. In addition, one could determine the efficiency of phase separation in the RCCS storage tank as the two-phase flashing phenomena ensues and the storage tank vents the steam produced. Task 3. Develop a system-level computational model that will describe the overall RCCS behavior as it transitions from forced flow to natural circulation and eventual two-phase flow in the passive cooling-mode of operation. This modeling can then be used to test the phenomenological models developed as a function of scale.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Complete Muon Collider Cooling Channel Design & Simulations – Phase 1

Considerable progress has been made in developing promising subsystems for muon beam cooling channels to provide the extraordinary reduction of emittance required for an Energy-Frontier Muon Collider, but lacks an end-to-end design. Meanwhile, the recent discovery of a Higgs-like boson has created interest in the High Energy physics community for a Higgs Factory to investigate its properties and verify whether it is Standard Model or beyond. This project will develop principles and tools to match emittances between and within muon beam cooling subsystems that may have different characteristics. The Helical Cooling Channel (HCC), which combines helical dipoles and a solenoid field, allows a general analytic approach to guide designs of transitions from one set of cooling channel parameters to another. These principles and tools will be applied to design a complete cooling channel that would be applicable to a Higgs Factory and an Energy Frontier Muon Collider.

Yoshikawa, Cary↗

Evaluation of the Impact of Slab Foundation Heat Transfer on Heating and Cooling in Florida

During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floors according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature measurements were taken at both buildings for more than 3 years prior to the experiments to ensure that the ground and foundation temperatures had fully come into equilibrium.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Impact of Slab Foundation Heat Transfer on Heating and Cooling in Florida

During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floors according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature measurements were taken at both buildings for more than 3 years prior to the experiments to ensure that the ground and foundation temperatures had fully come into equilibrium.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Cooling for a Muon Collider

To explore the new energy frontier, a new generation of particle accelerators is needed. Muon colliders are a promising alternative, if muon cooling can be made to work. Muons are 200 times heavier than electrons, so they produce less synchrotron radiation, and they behave like point particles. However, they have a short lifetime of 2.2 $\mathrm{\mu s}$ and the beam is more difficult to cool than an electron beam. The Muon Accelerator Program (MAP) was created to develop concepts and technologies required by a muon collider. An important effort has been made in the program to design and optimize a muon beam cooling system. The goal is to achieve the small beam emittance required by a muon collider. This work explores a final ionization cooling system using magnetic quadrupole lattices with a low enough $\beta^{\star} $ region to cool the beam to the required limit with available low Z absorbers.

43 PARTICLE ACCELERATORS↗

Complete Muon Collider Cooling Channel Design & Simulations

Considerable progress has been made in developing promising subsystems for muon beam cooling channels to provide the extraordinary reduction of emittance required for an Energy-Frontier Muon Collider, but lacks an end-to-end design. Meanwhile, the recent discovery of a Higgs-like boson has created interest in the High Energy physics community for a Higgs Factory to investigate its properties and verify whether it is Standard Model or beyond. This project will develop principles and tools to match emittances between and within muon beam cooling subsystems that may have different characteristics. The Helical Cooling Channel (HCC), which combines helical dipoles and a solenoid field, allows a general analytic approach to guide designs of transitions from one set of cooling channel parameters to another. These principles and tools will be applied to design a complete cooling channel that would be applicable to a Higgs Factory and an Energy Frontier Muon Collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absorber Cooling Circuits Dynamic Pressure Study

The flow rates through the flange/stick absorber cooling circuit and the crotch absorber cooling circuit should not exceed 2 GPM. The purpose of this document is to define the scope and present the results of the NSLSII absorber circuit water cooling pressure test. This report also provides flow capacities for each type of absorber cooling circuit in accordance with the required header pressure differential and other cooling system design parameters.

43 PARTICLE ACCELERATORS↗

Advanced SMRs Using S-CO2 Power Conversion with Dry Cooling

This report concludes the LDRD entitled "Advanced SMRs using S-CO2 Power Conversion with Dry Cooling." The goal of this project was to demonstrate the feasibility of using sCO 2 as the working fluid in a dry-cooled natural circulation loop. The reason for doing this is to demonstrate that such a loop could be utilized in small modular reactors (SMRs) as a method for (a) passively removing decay heat from the reactor and (b) cooling the reactor without using the copious amounts of water needed for wet-cooled reactors. The dry-cooling aspect of this work is possible due to the working conditions of a sCO 2 Brayton power conversion cycle. The loop was designed, built, and operated over the three-year life of the LDRD project. This report outlines some of the key accomplishments and some of the future work that we are continuing to try to complete in the future. A more comprehensive report will be completed and submitted in the Fall of 2015.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat Storage Options for Sodium, Salt and Helium Cooled Reactors to Enable Variable Electricity to the Grid and Heat to Industry with Base-Load Reactor Operations

Electricity markets are changing rapidly because of (1) the addition of wind and solar and (2) the goal of a low-carbon electricity grid. These changes result in times of high electricity prices and very low or negative electricity prices. California has seen its first month where more than 20% of the time (mid-day) the wholesale price of electricity was zero or negative. This creates large incentives for coupling heat storage to advanced reactors to enable variable electricity and industrial-heat output (to maximize revenue) while the reactor operates at base load (minimize cost). Recent studies have examined coupling various types of heat storage to Rankine and Brayton power cycles. However, there has been little examination of heat-storage options between (1) the reactor and (2) the power-conversion system or industrial customer. Heat-storage systems can be incorporated into sodium , helium-, and salt-cooled reactors. Salt-cooled reactors include the fluoride-salt-cooled high-temperature reactor (FHR) with its solid fuel and clean coolant and the molten salt reactor (MSR) with its fuel dissolved in the salt. For sodium and salt reactors, it is assumed that a heat-storage system would be in the secondary loop between the reactor and power cycle. For helium-cooled reactors, heat storage can be in the primary or secondary loop. This report is a first look at the rational and the heat storage options for deploying gigawatt-watt hour heat-storage systems with GenIV reactors. Economics and safety are the primary selection criteria. The leading heat-storage candidate for sodium-cooled systems (a low-pressure secondary system with small temperature drop across the reactor core) is sodium coolant stored in large steel tanks, with the coolant transferring heat in channels. The design minimizes sodium volume in the storage and, thus, the risks and costs associated with sodium. For helium systems (high-pressure with large temperature drop across the core), the leading heat storage options are (1) varying the temperature of the reactor core, (2) steel or alumina firebrick in a secondary pressure vessel and (3) nitrate or hot-rock/firebrick at atmospheric pressure. For salt systems (low pressure, high temperatures, and small temperature drop across the reactor core) the leading heat-storage systems are secondary salts. In each case, options are identified and questions to be addressed are identified. In some cases there is a strong coupling between the heat-storage technology and the power cycle. The leading sodium heat-storage technology may imply changes in the power cycle. High-temperature salt systems couple efficiency to Brayton power cycles that may create large incentives for the heat storage to remain within the power cycle rather than in any intermediate heat transfer loop.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity and Techno-Economic Analysis for Turbine Cooling Technologies for Higher Combined Cycle Efficiency

The objective of this study is to evaluate the impacts on natural gas combined cycle (NGCC) efficiency from several turbine cooling parameters through sensitivity and techno-economic analyses. This study aims to identify and evaluate cooling technologies, such as advanced blade materials, thermal barrier coatings, film cooling, internal cooling and stage purge cooling, that will lead to a gas turbine efficiency greater than 40 percent, which will eventually lead to a combined cycle efficiency of 65 percent or higher.

03 NATURAL GAS↗

Muon Capture, Phase Rotation, and Cooling in Pressurized RF Cavities

Gas-filled rf cavities can provide high-gradient accelerating fields for muons and can be used for simultaneous acceleration and cooling of muons. In this paper we explore using these cavities in the front-end of the capture and cooling systems for neutrino factories and muon colliders. We consider using gas-filled rf cavities for the initial front-end cooling systems. We also consider using them for simultaneous phase-energy rotation and cooling in a front-end system. We also consider using lower-density rf cavities, where the gas density is primarily for rf breakdown suppression, with less cooling effect. Pressurized rf cavities enable higher gradient rf within magnetic fields than is possible with evacuated cavities, enabling more options in the front-end. The status of designs of the capture, phase rotation, and precooling systems of muon beams in pressurized cavities is described

43 PARTICLE ACCELERATORS↗

Review of Cooling Water Chemistry at ORNL/SNS

The SNS comprises of 24 separate cooling loops to control temperature of the components.Appropriate cooling water chemistry is required in order to avoid corrosion damage of equipment, electric and mechanical malfunctions by deposition, as well as impairment of cooling by plugging of the water passages. Although up to now no severe chemistry related problems have yet occurred at SNS it is nevertheless prudent to consider some upgrades in order to assure reliable long-term performance.This report gives an assessment of the SNS cooling loops from the power plant generator technology perspective and experience. The most important recommendations are to operate the cooling loops with the highest achievable water purity and the highest reasonable mixed bed flow, to consider efficient main stream filtration, and to make and implement a common concept for water chemistry and for preventative maintenance. Main risk areas are electrochemical corrosion in loops with DC voltage, and materials performance of the RID window.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PDC Modifications for Analysis of Gas-Cooled Reactors with Direct Helium Brayton Cycle

Capabilities of the Plant Dynamics Code (PDC) have been extended to allow steady-state and transient simulation of graphite-cooled reactors with direct helium Brayton cycle. On the cycle side, the most significant code modification is the addition of helium properties, in the format required by the code’s equations. Since the code was already formulated to handle more complex real gas properties, adding helium as working fluid that behaves like ideal gas was fairly straightforward. A reactor module was added to PDC to simulate a reactor cooled by the working fluid of the Brayton cycle. Two options are supported: channel type, typical for graphite gas-cooled reactors, and pin type, typical for light-water and liquid metal-cooled reactors. The reactor module is an extension of the electrical heater model and simulates heat deposition in the fuel and transfer of this heat from the fuel to the coolant through the matrix and tube materials. The new reactor module becomes the third option in PDC for modeling heat addition to the cycle, besides previously modeled heat addition heat exchanger and electrical heater. In addition to those changes, other minor code modifications and improvements were introduced during the work of expanding PDC to modeling of gas-cooled reactors. These modifications are summarized in the last chapter of this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Emerging Technologies Review: Water Reuse Systems for Cooling Tower Applications

This report explores the concept of water reuse systems for cooling tower water makeup, specifically focusing on the use of alternative water sources, and the viability of these systems for Air Force installations and operations. Cooling is a critical requirement for DAF operations, and alternative water supplies that enable cooling tower use during a disruption of utility-supplied water increase Air Force resilience. The components of a water reuse system for cooling towers include alternative water supplies, storage, treatment, and distribution in addition to the cooling tower itself. Alternative water sources are not derived from fresh surface water or groundwater and can provide a redundant water supply to utility supply or to fresh water produced on site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring Interferometry Diagnostics for Optical Stochastic Cooling at FAST/IOTA

Optical Stochastic Cooling (OSC) is an advanced beam-cooling technique that will precede the traditional stochastic cooling. This method leverages optical radiation and high-precision feedback to cool the particles more efficiently than traditional stochastic methods by more than three orders of magnitude. As such, it is an enabler for the development of next generation discovery science machines at the frontiers of energy and intensity. This paper focuses on the development of the second phase of OSC and improving extreme beam cooling technique in accelerators. Along with the assembly and use of an interferometer to provide diagnostics and optimization to OSC systems. The interferometer can allow for the observation and analysis of fringe patterns from a recreated simpler version in the laser room. By leveraging interferometric techniques, OSC can achieve higher efficiency, verification, stability and performance.

Teriba, Folashade↗

Electron Ion Collider Strong Hadron Cooling design Summary

The Electron-Ion Collider (EIC) requires a high-energy cooler to maintain excellent beam quality and achieve high luminosity throughout long collision stores. To meet this requirement, the EIC project has adopted a novel approach known as Coherent Electron Cooling (CeC)—referred to as Strong Hadron Cooling (SHC)—which can provide rapid cooling rates at high energies. The SHC relies on an Energy Recovery Linac (ERL) to provide the intense, high-quality, and low-noise electron beam essential for the cooling process. This paper summarizes the design progress of the Strong Hadron Cooler for the EIC. We discuss key aspects of the project, including cooling physics modeling, luminosity evolution during collisions, the ERL design, risk mitigation strategies, remaining challenges, and ongoing R&D efforts.

43 PARTICLE ACCELERATORS↗

New Mexico cloud super cooled liquid water survey final report 2009.

Los Alamos and Sandia National Laboratories are partners in an effort to survey the super-cooled liquid water in clouds over the state of New Mexico in a project sponsored by the New Mexico Small Business Assistance Program. This report summarizes the scientific work performed at Sandia National Laboratories during the 2009. In this second year of the project a practical methodology for estimating cloud super-cooled liquid water was created. This was accomplished through the analysis of certain MODIS sensor satellite derived cloud products and vetted parameterizations techniques. A software code was developed to analyze multiple cases automatically. The eighty-one storm events identified in the previous year effort from 2006-2007 were again the focus. Six derived MODIS products were obtained first through careful MODIS image evaluation. Both cloud and clear-sky properties from this dataset were determined over New Mexico. Sensitivity studies were performed that identified the parameters which most influenced the estimation of cloud super-cooled liquid water. Limited validation was undertaken to ensure the soundness of the cloud super-cooled estimates. Finally, a path forward was formulized to insure the successful completion of the initial scientific goals which include analyzing different of annual datasets, validation of the developed algorithm, and the creation of a user-friendly and interactive tool for estimating cloud super-cooled liquid water.

54 ENVIRONMENTAL SCIENCES↗

Residual Strains in an Additively Processed Ni-based Superalloy Transpiration-Cooled Aerodynamic Leading Edge Structure using Neutron Diffraction

Selective Laser Melting (SLM) is a well-known additive manufacturing method based on a layer-by-layer building process that is capable of fabricating gas turbine Ni-based superalloy parts with complex and integrated cooling geometries that are typically not achievable using conventional casting methods. However, the impact of residual stress concentration on SLM component life is a concern. In this work, residual strains present at room temperature in an SLM Inconel 718 generic aerodynamic leading edge segment with transpiration cooling were investigated using neutron diffraction at Oak Ridge National Laboratory. This study reveals that areas of the part where complex cooling holes were printed exhibit residual tensile strains that can be detrimental to its integrity. The study paves the way for future studies of the design of cooling hole geometries and manufacturing parameters that achieve improved cooling while minimizing stress concentration effects.

Fouliard, Quentin↗