SEARCH · Engineering Papers
Results for “compaction”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Cross section generation for a conceptual horizontal, compact high temperature gas reactor
Not Available
A conceptual design study of a Compact Photon Source (CPS) for Jefferson Lab
Not Available
The impact of synchrotron radiation at the Compact Linear Collider
Not Available
A compact neutron spectrometer system
A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.
Characterization and alignment of a resonant cavity beam position monitor for the Compact LInear Collider (CLIC) project at CERN
Beam diagnostic devices are essential tools to sense the properties of the beam in particle accelerators. Beam Position Monitors (BPMs) are used to detect the transverse beam spatial coordinates. A large number of high-resolution resonant cavity BPMs, operating at 14GHz, are proposed to monitor the orbit of the two main beam linacs of the CLIC project. This paper discusses innovative calibration techniques on a dedicated test bench in the frame of the PACMAN project. The particular location of the electromagnetic center of the resonant cavity BPM is detected utilizing a stretched-wire measurement approach. Measurements, RF characterization and final fiducialization of the BPM electrical offset are treated with details. Initial studies through EM simulations of the cavity BPM are covered. The presented experimental results prove the feasibility of the alignment methodology with nanometric resolution.
Calibration of a compact ASIC-based data acquisition system for neutron/$γ$ discrimination and spectroscopy with organic scintillators
Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.
Design of a compact, radiation tolerant AlGaAs Geiger photodiode
Not Available
Optimization of the LLNL/CAMS gas-accepting ion source and 1 MV compact AMS for natural abundance radiocarbon analysis of CO2
Explore the source record for details and available documents.
Parallel FFT algorithms for high-order approximations on three-dimensional compact stencils
Not Available
High precision fundamental physics experiments using compact spin-transparent storage rings of low energy polarized electron beams
We present a new design of highly specialized small storage rings for low energy polarized electron beams. The new design is based on the transparent spin methodology that cancels the spin precession due to the magnetic dipole moment at any energy while allowing for spin precession induced by the fundamental physics of interest to accumulate. The buildup of the vertical component of beam polarization can be measured using standard Mott polarimetry that is optimal at low electron energy. These rings can be used to measure the permanent electric dipole moment of the electron, relevant to CP violation and matter-antimatter asymmetry in the universe, and to search for dark energy and ultra-light dark matter.
Onset and impact of plastic deformation in granular compaction
Not Available
Structural mechanism of HP1⍺-dependent transcriptional repression and chromatin compaction
Not Available
Prospects for a high-field, compact break-even axisymmetric mirror (BEAM) and applications
This paper explores the feasibility of a break-even-class mirror referred to as BEAM (break-even axisymmetric mirror): a neutral-beam-heated simple mirror capable of thermonuclear-grade parameters and $Q\sim 1$ conditions. Compared with earlier mirror experiments in the 1980s, BEAM would have: higher-energy neutral beams, a larger and denser plasma at higher magnetic field, both an edge and a core and capabilities to address both magnetohydrodynamic and kinetic stability of the simple mirror in higher-temperature plasmas. Axisymmetry and high-field magnets make this possible at a modest scale enabling a short development time and lower capital cost. Such a $Q\sim 1$ configuration will be useful as a fusion technology development platform, in which tritium handling, materials and blankets can be tested in a real fusion environment, and as a base for development of higher- $Q$ mirrors.
Sulfate Promotes Compact CaCO 3 Formation and Protects Portland Cement from Supercritical CO 2 Attack
Supercritical (sc) CO 2 in geologic carbon sequestration (GCS) can chemically and mechanically deteriorate wellbore cement, raising concerns for long-term operations. In contrast to the conventional view of “sulfate attack” on cement, we found that adding 0.15 M sulfate to the acidic brine can significantly reduce the impact of scCO 2 attack on Portland cement, resulting in stronger cement than that found in a sulfate-free system. Scanning electron microscopy revealed a decreased total attack depth in reacted cement in the presence of sulfate. With a newly defined minimum porosity term in reactive transport modeling, our model suggests that sulfate caused CaCO 3 to fill more nanopore spaces in the cement. Small angle X-ray scattering experiments also showed that sulfate can decrease the pore sizes of the carbonate layer. The results suggest that the interactions between sulfate and cement can generate a less porous CaCO 3 layer, which better resists acidic brine. Using this mechanism as a proof-of-concept, we tested the incorporation of sodium sulfate into Portland cement and synthesized new cement composites that show stronger resistance against scCO 2 attacks. Finally, these newly discovered interfacial interactions between CaCO 3 and sulfate provide new insights into engineering mechanically strong and green materials for safer GCS.
Physics-Driven Construction of Compact Primitive Gaussian Density Fitting Basis Sets
We present a model-assisted density fitting (MADF) basis set generator, an algorithm for generating primitive atomic Gaussian density fitting (DF) basis sets (DFBSs) from a contracted Gaussian orbital basis set (OBS). The MADF algorithm produces DFBSs suitable for accurate robust DF approximation of 2-particle interactions in mean-field and correlated electronic structures. The algorithm is designed to (a) saturate the OBS product space by a large regularized set of primitive solid-harmonic Gaussian shells with nonuniform distribution of exponents, followed by (b) pruning of the shells according to their contributions to the 2- body energy of a correlated atomic ensemble. Building the DFBS generator model almost exclusively on mathematical and physical principles allows one to limit the number of parameters that control the density fitting error to three, with a single set of parameters sufficient for computations with all basis cardinal numbers, with and without correlation of core electrons, with and without scalar and spin-dependent relativistic effects, spanning almost all of the Periodic Table. Performance assessment included basis sets up to quadruple-ζ quality from several major basis set families, using molecules composed of main-group, d-block, and f-block elements. The resulting DF errors in Hartree−Fock and second-order MP2 energies (with relativistic all-electron treatments, when appropriate) were on the order of 20 and 10 μE h per electron, respectively.