Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

GASNet-EX: A High-Performance, Portable Communication Library for Exascale

Partitioned Global Address Space (PGAS) models, typified by such languages as Unified Parallel C (UPC) and Co-Array Fortran, expose one-sided communication as a key building block for High Performance Computing (HPC) applications. Architectural trends in supercomputing make such programming models increasingly attractive, and newer, more sophisticated models such as UPC++, Legion and Chapel that rely upon similar communication paradigms are gaining popularity. GASNet-EX is a portable, open-source, high-performance communication library designed to efficiently support the networking requirements of PGAS runtime systems and other alternative models in future exascale machines. The library is an evolution of the popular GASNet communication system, building upon over 15 years of lessons learned. We describe and evaluate several features and enhancements that have been introduced to address the needs of modern client systems. Microbenchmark results demonstrate the RMA performance of GASNet-EX is competitive with several MPI-3 implementations on current HPC systems.

97 MATHEMATICS AND COMPUTING↗

MIT - Mighty Steps toward Energy Sustainability

Massachusetts Institute of Technology (MIT) partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce energy consumption by at least 30% as part of DOE’s Commercial Building Partnerships (CBP) Program.1 Lawrence Berkeley National Laboratory (LBNL) provided technical expertise in support of this DOE program. MIT is one of the U.S.’s foremost higher education institutions, occupying a campus that is nearly 100 years old, with a building floor area totaling more than 12 million square feet. The CBP project focused on improving the energy performance of two campus buildings, the Ray and Maria Stata Center (RMSC) and the Building W91 (BW91) data center. A key goal of the project was to identify energy saving measures that could be applied to other buildings both within MIT’s portfolio and at other higher education institutions. The CBP retrofits at MIT are projected to reduce energy consumption by approximately 48%, including a reduction of around 72% in RMSC lighting energy and a reduction of approximately 55% in RMSC server room HVAC energy. The energy efficiency measure (EEM) package proposed for the BW91 data center is expected to reduce heating, ventilation, and air-conditioning (HVAC) energy use by 30% to 50%, depending on the final air intake temperature that is established for the server racks. The RMSC, an iconic building designed by Frank Gehry, houses the Computer Science and Artificial Intelligence Laboratory, the Laboratory for Information and Decision Systems, and the Department of Linguistics and Philosophy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EnergyIQ

EnergyIQ-the first "action-oriented" benchmarking tool for non-residential buildings-provides a standardized opportunity assessment based on benchmarking results. along with decision-support information to help refine action plans. EnergyIQ offers a wide array of benchmark metrics, with visuall as well as tabular display. These include energy, costs, greenhouse-gas emissions, and a large array of characteristics (e.g. building components or operational strategies). The tool supports cross-sectional benchmarking for comparing the user's building to it's peers at one point in time, as well as longitudinal benchmarking for tracking the performance of an individual building or enterprise portfolio over time. Based on user inputs, the tool generates a list of opportunities and recommended actions. Users can then explore the "Decision Support" module for helpful information on how to refine action plans, create design-intent documentation, and implement improvements. This includes information on best practices, links to other energy analysis tools and more. The variety of databases are available within EnergyIQ from which users can specify peer groups for comparison. Using the tool, this data can be visually browsed and used as a backdrop against which to view a variety of energy benchmarking metrics for the user's own building. User can save their project information and return at a later date to continue their exploration. The initial database is the CA Commercial End-Use Survey (CEUS), which provides details on energy use and characteristics for about 2800 buildings (and 62 building types). CEUS is likely the most thorough survey of its kind every conducted. The tool is built as a web service. The EnergyIQ web application is written in JSP with pervasive us of JavaScript and CSS2. EnergyIQ also supports a SOAP based web service to allow the flow of queries and data to occur with non-browser implementations. Data are stored in an Oracle 10g database. References: Mills, Mathew, Brook and Piette. 2008. "Action Oriented Benchmarking: Concepts and Tools." Energy Engineering, Vol.105, No. 4, pp 21-40. LBNL-358E; Mathew, Mills, Bourassa, Brook. 2008. "Action-Oriented Benchmarking: Using the CEUS Database to Benchmark Commercial Buildings in California." Energy Engineering, Vol 105, No. 5, pp 6-18. LBNL-502E.

MILLS, EVAN↗

Challenges and Lessons Learned from an Analysis of Three Zero Energy Buildings

Zero energy buildings, or zero energy ready buildings, which are designed and operated by public or private commercial property owners can play an important role in reducing carbon emissions. This paper discusses lessons learned and key takeaways from an in-depth analysis of three zero energy buildings that took an integrated design and construction approach to significantly reduce energy use. Two of these projects are new construction and one is a retrofit to zero energy. Findings are based on project literature review, data analysis, and in-depth interviews with the building design teams and staff who were involved during the design, construction, and operation of the buildings. The paper addresses value proposition and cost data in such a way that other building owners can replicate the strategies and technology solutions in response to regulatory mandates or organizational goals. It also provides details on operational improvements taken at each zero energy building to enhance energy performance and increase the potential for load flexibility, and discusses challenges and lessons gleaned from design teams and building staff. The findings serve as a reference for building owners, designers, engineers, contractors, or others interested in, or involved with, the design, construction, or use of new or existing buildings. The paper also includes recommended pathways for widespread adoption of zero energy strategies that can be applied in various locations.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Comparison of Demand Response Performance with an EnergyPlus Model in a Low Energy Campus Building

We have studied a low energy building on a campus of the University of California. It has efficient heating, ventilation, and air conditioning (HVAC) systems, consisting of a dual-fan/dual-duct variable air volume (VAV) system. As a major building on the campus, it was included in two demand response (DR) events in the summers of 2008 and 2009. With chilled water supplied by thermal energy storage in the central plant, cooling fans played a critical role during DR events. In this paper, an EnergyPlus model of the building was developed and calibrated. We compared both whole-building and HVAC fan energy consumption with model predictions to understand why demand savings in 2009 were much lower than in 2008. We also used model simulations of the study building to assess pre-cooling, a strategy that has been shown to improve demand saving and thermal comfort in many types of building. This study indicates a properly calibrated EnergyPlus model can reasonably predict demand savings from DR events and can be useful for designing or optimizing DR strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building Prototypes Based on ANSI/ASHRAE/IES Standard 90.1-2019 Appendix G PRM: Technical Support Document

The two paths for documenting compliance with ANSI/ASHRAE/IES Standard 90.1 are the prescriptive path and the performance path. Beyond code programs and rating systems (for example, USGBC-LEED ) are primarily known to use a third path – the Appendix G Performance Rating Method. An update in the 2016 edition of Standard 90.1 approved the Appendix G Performance Rating System for code compliance, extending its application and allowing for greater consistency of modeling rules for code and beyond code building energy modeling. The Appendix G PRM provides rules for the development of whole building energy models of baseline and proposed models for calculating the “performance cost index target” value using the simulated energy results of the baseline and proposed models and the building performance factors published in Table 4.2.1.1 of the Standard. This report documents (1) the methodology used for development of the baseline and proposed energy models of the Pacific Northwest National Laboratory and U.S. Department of Energy commercial building prototypes using the Appendix G Performance Rating Method; and (2) the building performance factors that were calculated using those models.

97 MATHEMATICS AND COMPUTING↗

Sustain

Current building energy simulation technology requires excessive labor, time and expertise to create building energy models, excessive computational time for accurate simulations and difficulties with the interpretation of the results. These deficiencies can be ameliorated using modern graphical user interfaces and algorithms which take advantage of modern computer architectures and display capabilities. To prove this hypothesis, we developed an experimental test bed for building energy simulation. This novel test bed environment offers an easy-to-use interactive graphical interface, provides access to innovative simulation modules that run at accelerated computational speeds, and presents new graphics visualization methods to interpret simulation results. Our system offers the promise of dramatic ease of use in comparison with currently available building energy simulation tools. Its modular structure makes it suitable for early stage building design, as a research platform for the investigation of new simulation methods, and as a tool for teaching concepts of sustainable design. Improvements in the accuracy and execution speed of many of the simulation modules are based on the modification of advanced computer graphics rendering algorithms. Significant performance improvements are demonstrated in several computationally expensive energy simulation modules. The incorporation of these modern graphical techniques should advance the state of the art in the domain of whole building energy analysis and building performance simulation, particularly at the conceptual design stage when decisions have the greatest impact. More importantly, these better simulation tools will enable the transition from prescriptive to performative energy codes, resulting in better, more efficient designs for our future built environment.

Source record↗

Satellite Embedding-Based Population Imputation for Areas with Missing Building Footprint Data: A Computer Vision-Based Approach

High-resolution population modeling is important for supporting effective decision-making across diverse sectors. LandScan Mosaic generates population estimates at the level of individual buildings and aggregates them to 3 arc-second grids, and this approach performs well in regions where building footprint data are comprehensive and reliable. However, large portions of the globe still suffer from incomplete, sparse, or entirely missing building stock datasets, creating a structural limitation for strictly building-based population models. To address this research gap, this study proposes a computer vision-based framework that employs Google Earth Engine satellite embeddings and UNet, which allows us to directly impute grid-level population estimates in building-data-deficient areas. Applied to Taiwan as a case study, the framework achieved strong predictive performance with R$^{2}$ of 0.89, RMSE of 18.70, and MAE of 8.41, outperforming traditional machine learning approaches. Notably, the proposed framework effectively addressed building false-positive errors inherent in Global Human Settlement Layer (GHSL) data, correctly identifying uninhabited areas that were erroneously classified as populated. The framework also offers significant advantages for global population mapping, particularly in terms of scalability and temporal consistency, thereby extending the coverage and accuracy of high-resolution population products in data-scarce regions worldwide. Urban planners, decision makers, and related stakeholders can obtain granular population distributions to support more accurate and targeted infrastructure investment, service delivery, resource allocation, and risk assessment decisions.

97 MATHEMATICS AND COMPUTING↗

Scenario Analysis of Peak Demand Savings for Commercial Buildings with Thermal Mass in California

This paper reports on the potential impact of demand response (DR) strategies in commercial buildings in California based on the Demand Response Quick Assessment Tool (DRQAT), which uses EnergyPlus simulation prototypes for office and retail buildings. The study describes the potential impact of building size, thermal mass, climate, and DR strategies on demand savings in commercial buildings. Sensitivity analyses are performed to evaluate how these factors influence the demand shift and shed during the peak period. The whole-building peak demand of a commercial building with high thermal mass in a hot climate zone can be reduced by 30percent using an optimized demand response strategy. Results are summarized for various simulation scenarios designed to help owners and managers understand the potential savings for demand response deployment. Simulated demand savings under various scenarios were compared to field-measured data in numerous climate zones, allowing calibration of the prototype models. The simulation results are compared to the peak demand data from the Commercial End-Use Survey for commercial buildings in California. On the economic side, a set of electricity rates are used to evaluate the impact of the DR strategies on economic savings for different thermal mass and climate conditions. Our comparison of recent simulation to field test results provides an understanding of the DR potential in commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4, LaFayette, Georgia (CZ4), and Savannah, Georgia (CZ2)

The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk of condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.

Building America↗

Prototyping the BOPTEST Framework for Simulation-Based Testing of Advanced Control Strategies in Buildings

Advanced control strategies are becoming increasingly necessary in buildings in order to meet and balance requirements for energy efficiency, demand flexibility, and occupant comfort. Additional development and widespread adoption of emerging control strategies, however, ultimately require low implementation costs to reduce payback period and verified performance to gain control vendor, building owner, and operator trust. This is difficult in an already first-cost driven and risk-averse industry. Recent innovations in building simulation can significantly aid in meeting these requirements and spurring innovation at early stages of development by evaluating performance, comparing state-of-the-art to new strategies, providing installation experience, and testing controller implementations. This paper presents the development of a simulation framework consisting of test cases and software platform for the testing of advanced control strategies (BOPTEST - Building Optimization Performance Test). The objectives and requirements of the framework, components of a test case, and proposed software platform architecture are described, and the framework is demonstrated with a prototype implementation and example test case.

Blum, David↗

Building fault detection and diagnostics: Achieved savings, and methods to evaluate algorithm performance

Fault detection and diagnosis (FDD) represents one of the most active areas of research and commercial product development in the buildings industry. This paper addresses two questions concerning FDD implementation and advancement 1) What are today's users of FDD saving and spending on the technology? 2) What methods and datasets can be used to evaluate and benchmark FDD algorithm performance? Relevant to the first question, 26 organizations that use FDD across a total 550 buildings and 97 M sf achieved median savings of 8%. Twenty-seven FDD users reported that the median base cost for FDD software, annual recurring software cost, and annual labor cost were $8, $2.7 and $8 per monitoring point, with a median implementation size of approximately 1300 points. To address the second question, this paper describes a systematic methodology for evaluating the performance of FDD algorithms, curates an initial test dataset of air handling unit (AHU) system faults, and completes a trial to demonstrate the evaluation process on three sample FDD algorithms. The work provided a first step toward a standard evaluation of different FDD technologies. Finally, it showed the test methodology is indeed scalable and repeatable, provided an understanding of the types of insights that can be gained from algorithm performance testing, and highlighted the priorities for further expanding the test dataset.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The mechanism of eutectic modification by trace impurities

In the quest toward rational design of materials, establishing direct links between the attributes of microscopic building blocks and the macroscopic performance limits of the bulk structures they comprise is essential. Building blocks of concern to the field of crystallization are the impurities, foreign ingredients that are either deliberately added to or naturally present in the growth medium. While the role of impurities has been studied extensively in various materials systems, the inherent complexity of eutectic crystallization in the presence of trace, often metallic impurities ('eutectic modification') remains poorly understood. In particular, the origins behind the drastic microstructural changes observed upon modification are elusive. Herein, we employ an integrated imaging approach to shed light on the influence of trace metal impurities during the growth of an irregular (faceted-non-faceted) eutectic. Our dynamic and 3D synchrotron-based X-ray imaging results reveal the markedly different microstructural and, for the first time, topological properties of the eutectic constituents that arise upon modification, not fully predicted by the existing theories. Together with ex situ crystallographic characterization of the fully-solidified specimen, our multi-modal study provides a unified picture of eutectic modification: The impurities selectively alter the stacking sequence of the faceted phase, thereby inhibiting its steady-state growth. Consequently, the non-faceted phase advances deeper into the melt, eventually engulfing the faceted phase in its wake. We present a quantitative topological framework to rationalize these experimental observations.

36 MATERIALS SCIENCE↗

sympl (v. 0.4.0) and climt (v. 0.15.3) – towards a flexible framework for building model hierarchies in Python

sympl (System for Modelling Planets) andclimt (Climate Modelling and Diagnostics Toolkit) are anattempt to rethink climate modelling frameworks from the ground up. The aimis to use expressive data structures available in the scientific Pythonecosystem along with best practices in software design to allow scientists toeasily and reliably combine model components to represent the climate systemat a desired level of complexity and to enable users to fully understandwhat the model is doing. sympl is a framework which formulates the model in terms of astate that gets evolved forward in time or modified within a specifictime by well-defined components. sympl's design facilitates buildingmodels that are self-documenting, are highly interoperable, and providefine-grained control over model components and behaviour. symplcomponents contain all relevant information about the input they expect andoutput that they provide. Components are designed to be easily interchanged,even when they rely on different units or array configurations.sympl provides basic functions and objects which could be used inany type of Earth system model. climt is an Earth system modelling toolkit that contains scientificcomponents built using sympl base objects. These include both purePython components and wrapped Fortran libraries. climt providesfunctionality requiring model-specific assumptions, such as stateinitialization and grid configuration. climt's programming interfacedesigned to be easy to use and thus appealing to a wide audience. Model building, configuration and execution are performed through a Pythonscript (or Jupyter Notebook), enabling researchers to build an end-to-endPython-based pipeline along with popular Python data analysis andvisualization tools.

97 MATHEMATICS AND COMPUTING↗

Goddard Space Flight Center solar array missions, requirements and directions

The Goddard Space Flight Center (GSFC) develops and operates a wide variety of spacecraft for conducting NASA's communications, space science, and earth science missions. Some are 'in house' spacecraft for which the GSFC builds the spacecraft and performs all solar array design, analysis, integration, and test. Others are 'out of house' spacecraft for which an aerospace contractor builds the spacecraft and develops the solar array under direction from GSFC. The experience of developing flight solar arrays for numerous GSFC 'in house' and 'out of house' spacecraft has resulted in an understanding of solar array requirements for many different applications. This presentation will review those solar array requirements that are common to most GSFC spacecraft. Solar array technologies will be discussed that are currently under development and that could be useful to future GSFC spacecraft.

Gaddy, Edward↗

Goddard Space Flight Center Solar Array Missions, Requirements and Directions

The Goddard Space Flight Center (GSFC) develops and operates a wide variety of spacecraft for conducting NASA's communications, space science, and earth science missions. Some are "in house" spacecraft for which the GSFC builds the spacecraft and performs all solar array design, analysis, integration, and test. Others are "out of house" spacecraft for which an aerospace contractor builds the spacecraft and develops the solar array under direction from GSFC. The experience of developing flight solar arrays for numerous GSFC "in house" and "out of house" spacecraft has resulted in an understanding of solar array requirements for many different applications. This presentation will review those solar array requirements that are common to most GSFC spacecraft. Solar array technologies will be discussed that are currently under development and that could be useful to future GSFC spacecraft.

Gaddy, Edward↗

mdtmFTP

To address the high-performance challenges of data transfer in big data era, we research, develop, and implement mdtmFTP: a High-performance Data Transfer Tool in Bigdata Era. DOE’s Advanced Scientific Computing Research (ASCR) office has funded Fermilab and Brookhaven National Laboratory to collaboratively work on the Multicore-Aware Data Transfer Middleware (MDTM) project. MDTM aims to accelerate data movement toolkits on multicore systems. mdtmFTP is the latest outcome of this continued research effort. mdtmFTP is a high-performance data transfer tool that builds upon the MDTM middleware. Initial tests show that mdtmFTP performs better than existing data transfer tools

Zhang, L.↗