Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Design of a new charge exchange recombination spectroscopy diagnostic for impurity transport experiments at Wendelstein 7-X

In this study, we present the design of a new charge exchange recombination spectroscopy (CXRS) system for Wendelstein 7-X (W7-X), which aims at measuring line radiation from highly ionized iron impurities after laser blow off injections over transport timescales. New fiber bundles with a core diameter of 600 µm have been added to one of the existing optical systems at W7-X used for CXRS. The fibers direct collected light to five newly developed single channel high frame rate F/2.8 spectrometers. The new custom-made spectrometers are built using entirely off-the-shelf and 3D printed components, and employ a round-to-linear fiber bundle, instead of an entrance slit, to maximize light throughput. The detector is an ultra-low readout noise EM-CCD camera capable of frame rates of up to 10 000 fps for about 500 consecutive frames when operated using a single readout channel. Such high frame rates will enable the study of inward convection of injected impurities. An initial sensitivity study is performed using a newly developed Markov chain Monte Carlo approach based on the pySTRAHL impurity transport code. This study indicates that, with the addition of the new CX diagnostic, impurity convection velocities can be inferred.

Instruments & Instrumentation↗

Development of mercuric iodide uncooled x ray detectors and spectrometers

The results obtained in the development of miniature, lowpower, light weight mercuric iodide, HgI2, x ray spectrometers for future space missions are summarized. It was demonstrated that HgI2 detectors can be employed in a high resolution x ray spectrometer, operating in a scanning electron microscope. Also, the development of HgI2 x ray detectors to augment alpha backscattering spectrometers is discussed. These combination instruments allow for the identification of all chemical elements, with the possible exception of hydrogen, and their respective concentrations. Additionally, further investigations of questions regarding radiation damage effects in the HgI2 x ray detectors are reported.

Iwanczyk, Jan S.↗

Constraints on vacuum decay from the microwave background

We consider the possible decay of a vacuum with nonzero energy density into radiation. This is one way to introduce a time-varying cosmological constant, which has been suggested as a means of resolving the cosmological constant problem. We concentrate on the model of Freese et al., in which the vacuum energy density is given as a fraction x/(1 - x) of the energy density of radiation. Using equations for the visible extragalactic background light and assuming that the vacuum decay energy is converted entirely into photons with a Planckian spectrum, we show that the decay process would be capable of contributing significantly to the intensity of the cosmic microwave background. Comparison with COBE observations leads to the constraint x is equal to or less than 0.001, which is stronger than the upper limit of 0.07 obtained previously by Freese et al. from considerations of primordial nucleosynthesis.

Overduin, J. M.↗

Lightning and Other Influences On Tropical Tropospheric Ozone: Empirical Studies of Covariation

Tropical and subtropical tropospheric ozone are important radiatively active species, with particularly large effects in the upper third of the troposphere. Temporal variability of O3 has proved difficult to simulate day by day in process models. Thus, individual roles of lightning, biomass burning, and other pollution in providing precursor NO(x), radicals, and chain carriers (CO, hydrocarbons) remain unquantified by simulation, and it is theoretically reasonable that individual roles are magnified by a joint synergy. We use wavelet analysis and Burg-algorithm maximum entropy spectral analyses to describe time-scales and correlation of ozone with proxies for processes controlling its concentration. Our empirical studies link time variations apparent in several datasets: the SHADOZ (Southern Hemisphere Additional Ozonesondes) network stations (Nairobi, Fiji), and auxiliary series with power to explain ozone-determining processes, with some interpretation based on the TTO (Tropical Tropospheric Ozone) product derived from TOMS (the Total Ozone Mapping Spectrometer). The auxiliary series are The OTD/LIS(Optical Transient Detector/Lightning Imaging Sensor) measurements of the lightning NO(x) source, the OLR (Outgoing Longwave Radiation)measurement of high-topped clouds, and standard meteorological variables from the United States NCEP (National Centers for Environmental Prediction) and Data Assimilation Office analyses. Concentrating on equatorial ozone, we compare the statistical evidence on the variability of tropospheric ozone. Important variations occur on approximately two-week, two-month (Madden-Julian Oscillation) and annual scales, and relations with OLR suggest controls associated with continental clouds. Hence we are now using the Lightning Imaging Sensor data set to indicate NO(x) sources. We report initial results defining relative roles of the process mentioned affecting O3 using their covariance properties.

Chatfield, Robert B.↗

Effect of radiation-induced defects on the superfluid density and optical conductivity of overdoped La 2 - x Sr x CuO 4

Using a combination of time-domain THz spectroscopy (TDTS) and mutual inductance measurements, we have investigated the low-energy electrodynamic response of overdoped La$_{2-x}$Sr$_x$CuO$_4$ films that have been exposed to ion irradiation. Films went through three rounds of irradiation (2, 4, and 6 $\times 10^{13}$ ions/cm$^2$) and mututal inductance and TDTS experiments were performed between each step. Together with the as-grown film, this gives four different levels of disorder. The transport scattering rate that is measured directly in the THz experiments is an approximately linear function of the radiation dose at all temperatures. This is consistent with a proportionate increase in elastic scattering from point-like 2D disorder. Here, in the superconducting state we find that the relation between T$_c$, the superfluid density, and the scattering rates are quantitatively at odds with the predictions based on the extant theory of Abrikosov-Gorkov-like pair breaking in a dirty d-wave superconductor. Increasing disorder causes only a small change in T$_c$ for the overdoped films, but the changes to the $\omega \sim 0$ superfluid density are much larger.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

190-GHz radiation from a quasioptical Josephson junction array

At 190 GHz, 0.36 micro W has been detected from an 11 x 58 array of niobium Josephson junctions. The power is radiated directly into free space above the surface of the two-dimensional array of junctions. Detection is made by a commercial bolometer outside the array cryostat. The junctions in the array are closely spaced in the y-dimension, but spaced by more than one-half wavelength in the x-direction. This asymmetry results in mutual phase-locking between adjacent junctions suitable for the production of y-polarized radiation. The resonance and asymmetry also result in a reasonable impedance match between the Josephson junctions and the free-space radiation mode.

ARRAY CRYOSTAT↗

Unprecedented Radiation Resistant Thorium–Binaphthol Metal–Organic Framework

A thorium–organic framework (TOF-16) containing hexameric secondary building units connected by functionalized binaphthol linkers was synthesized, characterized, and irradiated to probe its radiation resistance. Radiation stability was examined using γ-rays and 5 MeV He 2+ ions to simulate α particles. γ-irradiation of TOF-16 to an unprecedented 4 MGy dose resulted in no apparent bulk structural damage visible by X-ray diffraction. To further probe radiation stability, we conducted the first He 2+ ion irradiation study of a metal–organic framework (MOF). Diffraction data indicate onset of crystallinity loss upon approximately 15 MGy of irradiation and total loss of crystallinity upon exposure to approximately 25 MGy of He 2+ ion irradiation. In conclusion, the high radiation resistance observed suggests MOFs can withstand radiation exposure at doses found in nuclear waste streams and highlights the need for a systematic approach to understand and eventually design frameworks with exceptional radiation resistance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiometric and Radiation Response of Visible FPAs

The readout integrated circuit (ROIC) used in these devices was originally developed for use in space based infrared systems operating at deep cryogenic temperatures and was selected because of its proven tolerance to total ionizing radiation? The detectors are a 128 x 128 array of 60 pm x 60 pm pixel elements that have been anti-reflection (AR) coated to improve the response at very short wavelengths. These visible focal plane arrays were operated at -40 C (233 K). Two focal planes were characterized using cobalt-60 radiation to produce ionizing total dose damage in the VFPAs. Both operational and performance data were obtained as functions of total dose. The first device tested showed no appreciable change in responsivity or noise up to 300 krad(Si). However, at the next dose level of 600 krad(Si), the readout was non-operational due to failure in the digital circuitry. The second device was characterized to a total dose of 750 krad(Si) with no observed change in responsivity. An increase dark current was observed in both devices, and in the second device, the dark current caused an increase in noise at low irradiance at 400 krad(Si) and above. The increase in dark current was somewhat un-expected for visible PIN detectors. The median dark current increased more than two orders of magnitude at 300 krad(Si) for the first device and a factor of 350 at 750 krad(Si) for pixels near the edge for the second device. The dark current was found to be a strong function of detector bias, with pixels near the edge of the array showing a greater increase in dark current with bias than those near the center. Since the optical response was not a function of bias, it is hypothesized that the dark current is a surface effect and that the variation in dark current with location is due to a variation in pixel bias, caused by a voltage drop across the pixel common lead. As the total dose increased, the dark current and the voltage drop increased

Hubbs, John↗

Advancing X-ray quantum imaging through Monte-Carlo simulations

Imaging with X-rays poses fundamental limits due to radiation damage of the highly energetic photons. This becomes problematic for sensitive biological systems such as subcellular structures. Lowering the radiation dose, without sacrificing the signal-to-noise ratio, would be desirable for any kind of imaging modalities involving X-rays. To achieve this goal, quantum imaging with entangled X-ray photons constitutes a promising route. Production of biphotons have been demonstrated in the X-ray regime by the process of Spontaneous Parametric Down-Conversion (SPDC). However, compared to SPDC in the regime of visible light, the production rate for X-ray biphotons is extremely low. With the introduction of new high average brightness X-ray sources, such as 4th generation synchrotrons and high repetition rate Free-Electron X-ray Lasers (XFEL), quantum imaging may become practical. We introduce a ray tracing approach using Monte-Carlo sampling, specifically designed for quantum imaging with entangled X-ray photons generated by SPDC. By simulation, the superior image quality of quantum over classical imaging methods is demonstrated using realistic experimental conditions available at high repetition rate XFELs. With these simulations, we can efficiently assist the design of future experiments at beam lines, which can substantially accelerate the advancement of X-ray quantum imaging and reduce costs.

Entangled Photons↗

Luminescence from Self‐Trapped Excitons and Energy Transfers in Vacancy‐Ordered Hexagonal Halide Perovskite Cs 2 HfF 6 Doped with Rare Earths for Radiation Detection

Abstract Compared to halides Cs 2 HfX 6 (X = Cl, Br, I) with a vacancy‐ordered cubic double perovskite structure, the halide Cs 2 HfF 6 (CHF), with a hexagonal Bravais lattice, possesses a higher mass density and chemical stability for radiation detection. Luminescence properties and energy transfer mechanisms of rare‐earths‐doped CHF materials are studied here. The structure of CHF is identified as a new type of vacancy‐ordered hexagonal perovskite, with the same type of building blocks of the double perovskite but stacked with single layers. Density‐functional theory calculations reveal a large bandgap of CHF. A broad emission is observed from the pristine CHF host, which is suggested to be associated with self‐trapped excitons (STEs). A series of rare‐earths‐doped materials are designed utilizing the STE emissions, and efficient energy transfers from STEs and Tb 3+ to Eu 3+ are achieved for tunable emissions. The codoped material shows stable emission under X‐ray irradiation, with 10.2% reduction from its initial emission intensity, associated with possible structural evolution by radiation‐induced deformation of the soft host. The radiation responses of singly and codoped materials are evaluated, and the codoped material is found to be more sensitive to the radiation energy than the singly doped or pristine CHF for radiation detection.

36 MATERIALS SCIENCE↗

Neutron and gamma ray production in the 1991 June X-class flares

We present new calculations of pion radiation and neutron emission from solar flares. We fit the recently reported high energy GAMMA-1 observations with pion radiation produced in a solar flare magnetic loop. We calculate the expected neutron emission in such a loop model and make predictions of the neutron fluences expected from the 1991 June X-class flares.

Ramaty, R.↗

Thermal loading on self-seeding monochromators in x-ray free electron lasers

One approach to achieve longitudinally coherent hard X-ray free electron laser (XFEL) radiation is to introduce a single-crystal monochromator in the beam path to generate a co-propagating, time-synchronized self-seeding radiation pulse. For modern high-repetition rate XFELs, however, thermal loading on the crystal can degrade the quality of the seed pulse. To assess limitations on the maximum XFEL pulse repetition rate imposed by the seeding crystal, a comprehensive study of thermomechanical, and X-ray diffraction effects within the crystal is presented in this paper for two consecutive self-amplified spontaneous emission pulses incident on both reflective and transmissive crystal monochromators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionization sources of the ionospheric D and E regions.

Solar radiation in the extreme ultraviolet, lambda less than 1216 A, and X-ray regions of the spectrum is deposited between 60 and 200 km producing free electrons and ions. Below 60 km cosmic radiation creates ion pairs. Energetic electron precipitation, as during auroral events, creates additional ionization as do protons originating from solar flares, which also enhance solar X-ray and extreme ultraviolet emission. At night scattered solar Lyman alpha (1216 A) and Lyman beta (1026 A) as well as He I (584 A) and He II (304 A) are present. These and other lesser known sources, for example cosmic X-ray and extreme ultraviolet radiation, contribute to the formation of the nocturnal D and E regions.

Aikin, A. C.↗

A comparison between bright points in a coronal hole and a quiet-sun region

A comparison is made of the morphological structure and temporal behavior of the emission from coronal bright points in a coronal hole and a quiet region, using data from the Harvard EUV experiment on Skylab. It is found that, in both regions, coronal bright points are located at network boundaries and cover a range of sizes from 10 to 40 in in linear extent. In a given bright pint, the peaks of emission in the six different lines, measured simultaneously through the same instrument slit, are not always cospatial, implying that bright points consist of a complex of small-scale loops at different temperatures. The intensity of bright points in both regions is also characterized by a significant temporal variability in all the wavelengths measured. This variability exhibits no regular periodicity. Yet the ratio of the varying (ac) to the constant (dc) components of the emission, in all the bright points studied, has a local maximum at 1-2 x 10 to the 5th k which coincides with the peak of the radiative loss function, and another local maximum at Mg x (1.4 x 10 to the 6th K). It is found that coronal bright points in a coronal hole or a quiet region are indistinguishable structures, and, therefore, conclude that they are independent of the overlying background corona.

Habbal, Shadia Rifai↗