Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Monitoring Sulfuric Acid and Temperature Using Raman Spectroscopy and Multivariate Chemometrics

Multivariate regression models were optimized for the quantification of sulfuric acid (H 2 SO 4 ) [0–8 M] and temperature (20 °C–80 °C) in the presence of ammonium sulfate ((NH 4 ) 2 SO 4 [0–0.6 M]) using Raman spectroscopy. Optical vibrational spectroscopy is a useful nondestructive technique for the in situ analysis of complex chemical systems notoriously difficult to monitor in situ and in real-time. Multivariate analysis, a chemometrics method, can be paired with these nondestructive optical methods for determining analyte concentration and speciation in complex solutions, such as dissociated species in polyprotic acids, e.g., H 2 SO 4 . The effect of temperature is often overlooked although it can have a major influence on speciation and the corresponding Raman spectra. Here, in this study, partial least squares regression models were optimized for the quantification of H 2 SO 4 and its two deprotonated forms as a function of temperature. Measuring bisulfate as a function of temperature is particularly challenging owing to changes in the second dissociation constant. A designed training set effectively minimized the sample set size and trained a robust predictive model with percent root mean square error of <3% for H 2 SO 4 . The practical strategy employed here was demonstrated to be effective for building chemometric models that directly account for dynamic temperatures with static samples and is shown to be amenable to flow cell analysis applications with a simple calibration transfer for process monitoring applications.

D-optimal design↗

CEM MARS 6 Microwave Incident

A fire occurred in a CEM MARS 6 analytical microwave during microwave-assisted, acid digestion of a soil sample in a Research and Development (R&D) laboratory. The soil sample had been pretreated at 550°C for approximately 4 hours in a furnace prior to digesting in the microwave. Less than 1-gram aliquots of the pretreated soil sample were placed into separate microwave reaction vessels along with an acid mixture used for digestion. The microwave was used to facilitate digestion of the samples. Microwave reaction vessels were loaded with acid and soil samples, sealed in cassettes, and the cassettes placed onto a microwave carousel. A temperature probe that senses the reaction temperature during the run was inserted into the Reference Cell thermowell. The contents of the Reference Cell were identical to the contents of the other reaction cells. The researcher initiated the run and then left the laboratory to perform other work. Upon returning to check the digestion run, flames and smoke were observed originating from the microwave. The researcher exited the lab, immediate emergency actions were taken, and the local fire department responded and extinguished the fire. No personnel were injured, and no facility structural damage occurred. The affected microwave is a total loss. The fire investigation revealed the most credible cause of the fire is an incompatible temperature probe that did not accurately measure temperature of the liquid phase of the Reference sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Remote measurement of ocean temperature from depolarization in Raman scattering

Ocean temperatures may be mapped in three dimensions from an aircraft down to depths of 2 to 4 attenuation lengths by monitoring Raman radiation backscattered from a laser beam. This paper describes laboratory experiments on the temperature dependence of Raman spectra of saline solutions and calculations of the expected performance of a field system. The Raman technique is of greatest potential utility in coastal and estuarine waters where gradients are relatively high. It is estimated that seawater temperature may be measured to a statistical precision of 0.5 C at depths to four attenuation lengths in two meter water, using one Joule of transmitted laser energy.

Chang, C. H.↗

Short-term cyclic variations and diurnal variations of the Venus upper atmosphere

The vertical structure of the nighttime thermosphere and exosphere of Venus was discussed. A comparison of the day and nighttime profiles indicates, contrary to the model of Dickinson and Riley (1977), that densities (principally atomic oxygen) dropped sharply from day to night. It was suggested either that the lower estimates were related to cooler exospheric temperatures at night or that the atomic bulge was flatter than expected at lower altitudes. Large periodic oscillations, in both density and inferred exospheric temperatures, were detected with periods of 5 to 6 days. The possibility that cyclic variations in the thermosphere and stratosphere were caused by planetary-scale waves, propagated upward from the lower atmosphere, was investigated using simultaneous temperature measurements obtained by the Venus radiometric temperature experiment (VORTEX). Inferred exospheric temperatures in the morning were found to be lower than in the evening as if the atmosphere rotated in the direction of the planet's rotation, similar to that of earth. Superrotation of the thermosphere and exosphere was discussed as a possible extension of the 4-day cyclic atmospheric rotation near the cloud tops.

Keating, G. M.↗

Regional geothermal exploration in Egypt

A study is presented of the evaluation of the potential geothermal resources of Egypt using a thermal gradient/heat flow technique and a groundwater temperature/chemistry technique. Existing oil well bottom-hole temperature data, as well as subsurface temperature measurements in existing boreholes, were employed for the thermal gradient/heat flow investigation before special thermal gradient holes were drilled. The geographic range of the direct subsurface thermal measurements was extended by employing groundwater temperature and chemistry data. Results show the presence of a regional thermal high along the eastern margin of Egypt with a local thermal anomaly in this zone. It is suggested that the sandstones of the Nubian Formation may be a suitable reservoir for geothermal fluids. These findings indicate that temperatures of 150 C or higher may be found in this reservoir in the Gulf of Suez and Red Sea coastal zones where it lies at a depth of 4 km and deeper.

Morgan, P.↗

Observations of stratospheric aerosols associated with the El Chichon eruption

Lidar observations of aerosols were carried out at Aberystwyth between Nov. 1982 and Dec. 1985 using a frequency doubled and frequency tripled Nd/Yag laser and a receiver incorporating a 1 m diameter in a Newtonian telescope configuration. In analyses of the experimental data attention is paid to the magnitude of the coefficient relating extinction and backscatter, the choice being related to the possible presence of aerosols in the upper troposphere and the atmospheric densities employed in the normalisation procedure. The aerosol loading showed marked day to day changes in early months and an overall decay was apparent only after April 1983, this decay being consistent with an e sup -1 time of about 7 months. The general decay was accompanied by a lowering of the layer but layers of aerosols were shown intermittently at heights above the main layer in winter months. The height variations of photon counts corrected for range, or of aerosol backscatter ratio, showed clear signatures of the tropopause. A strong correlation was found between the heights of the tropopause identified from the lidar measurements and from radiosonde-borne temperature measurements. A notable feature of the observations is the appearance of very sharp height gradients of backscatter ratio which seem to be produced by differential advection.

Thomas, L.↗

Experimental investigation of a supersonic swept ramp injector using laser-induced iodine fluorescence

Planar measurements of injectant mole fraction and temperature have been conducted in a nonreacting supersonic combustor configured with underexpanded injection in the base of a swept ramp. The temperature measurements were conducted with a Mach 2 test section inlet in streamwise planes perpendicular to the test section wall on which the ramp was mounted. Injection concentration measurements, conducted in cross flow planes with both Mach 2 and Mach 2.9 free stream conditions, dramatically illustrate the domination of the mixing process by streamwise vorticity generated by the ramp. These measurements, conducted using a nonintrusive optical technique (laser-induced iodine fluorescence), provide an accurate and extensive experimental data base for the validation of computation fluid dynamic codes for the calculation of highly three-dimensional supersonic combustor flow fields.

Hartfield, Roy J.↗

Fiber optic and laser sensors VII; Proceedings of the Meeting, Boston, MA, Sept. 5-7, 1989

Various papers on fiber optic and laser sensors are presented. Individual topics addressed include: fiber optic photoelastic pressure sensor for high-temperature gases, fiber optic gyroscope using an eight-component LiNbO3 integrated optic circuit, design and performance of a fiber optic gyroscope using integrated optics, digital angular position sensor using wavelength division multiplexing, simple repeatable fiber optic intensity sensor for temperature measurement, compensation for effects of ambient temperature on rare-earth-doped fiber optic thermometer.

Udd, Eric↗

Thermal control system for SSF sensor/electronics

A thermal control system was designed for the Space Station Freedom (SSF) sensor/electronics box (SSTACK). Multi-layer insulation and heaters are used to maintain the temperatures of the critical components within their operating and survival temperature limits. Detailed and simplified SSTACK thermal models were developed and temperatures were calculated for worst-case orbital conditions. A comparison between the two models showed very good agreement. Temperature predictions were also compared to measured temperatures from a thermal-vacuum test.

Akau, R. L.↗

Application of the pressure sensitive paint technique to steady and unsteady flow

Pressure sensitive paint is a newly-developed optical measurement technique with which one can get a continuous pressure distribution in much shorter time and lower cost than a conventional pressure tap measurement. However, most of the current pressure sensitive paint applications are restricted to steady pressure measurement at high speeds because of the small signal-to-noise ratio at low speed and a slow response to pressure changes. In the present study, three phases of work have been completed to extend the application of the pressure sensitive paint technique to low-speed testing and to investigate the applicability of the paint technique to unsteady flow. First the measurement system using a commercially available PtOEP/GP-197 pressure sensitive paint was established and applied to impinging jet measurements. An in-situ calibration using only five pressure tap data points was applied and the results showed good repeatability and good agreement with conventional pressure tap measurements on the whole painted area. The overall measurement accuracy in these experiments was found to be within 0.1 psi. The pressure sensitive paint technique was then applied to low-speed wind tunnel tests using a 60 deg delta wing model with leading edge blowing slots. The technical problems encountered in low-speed testing were resolved by using a high grade CCD camera and applying corrections to improve the measurement accuracy. Even at 35 m/s, the paint data not only agreed well with conventional pressure tap measurements but also clearly showed the suction region generated by the leading edge vortices. The vortex breakdown was also detected at alpha=30 deg. It was found that a pressure difference of 0.2 psi was required for a quantitative pressure measurement in this experiment and that temperature control or a parallel temperature measurement is necessary if thermal uniformity does not hold on the model. Finally, the pressure sensitive paint was applied to a periodically changing pressure field with a 12.8s time period. A simple first-order pole model was applied to deal with the phase lag of the paint. The unsteady pressure estimated from the time-changing pressure sensitive paint data agreed well with the pressure transducer data in regions of higher pressure and showed the possibility of extending the technique to unsteady pressure measurements. However, the model still needs further refinement based on the physics of the oxygen diffusion into the paint layer and the oxygen quenching on the paint luminescence.

Shimbo, Y.↗

Design and Checkout of a High Speed Research Nozzle Evaluation Rig

The High Flow Jet Exit Rig (HFJER) was designed to provide simulated mixed flow turbojet engine exhaust for one- seventh scale models of advanced High Speed Research test nozzles. The new rig was designed to be used at NASA Lewis Research Center in the Nozzle Acoustic Test Rig and the 8x6 Supersonic Wind Tunnel. Capabilities were also designed to collect nozzle thrust measurement, aerodynamic measurements, and acoustic measurements when installed at the Nozzle Acoustic Test Rig. Simulated engine exhaust can be supplied from a high pressure air source at 33 pounds of air per second at 530 degrees Rankine and nozzle pressure ratios of 4.0. In addition, a combustion unit was designed from a J-58 aircraft engine burner to provide 20 pounds of air per second at 2000 degrees Rankine, also at nozzle pressure ratios of 4.0. These airflow capacities were designed to test High Speed Research nozzles with exhaust areas from eighteen square inches to twenty-two square inches. Nozzle inlet flow measurement is available through pressure and temperature sensors installed in the rig. Research instrumentation on High Speed Research nozzles is available with a maximum of 200 individual pressure and 100 individual temperature measurements. Checkout testing was performed in May 1997 with a 22 square inch ASME long radius flow nozzle. Checkout test results will be summarized and compared to the stated design goals.

Castner, Raymond S.↗

Numerical Thermal Model of a 30-cm NSTAR Ion Thruster

A thermal computer model of the NSTAR (Nasa Solar Electric Propulsion Technology Applications Readiness) xenon ion thruster has been produced using a lumped parameter thermal nodal network scheme. This model contains 104 nodes on the thruster and was implemented using SINDA (Systems Improved Numerical Differencing Analyzer) and TRASYS (Thermal Radiation Analyzer System) on various UNIX workstations. The model includes radiation and conduction heat transfer, the effect of plasma interaction on the thruster, and an account for finely perforated surfaces. The model was developed in conjunction with an NSTAR thruster outfitted with approximately 20 thermocouples for thermal testing at the NASA Lewis Research Center. The results of these experiments were used to calibrate and confirm the computer model first without and then with the plasma interaction. The calibrated model was able to predict discharge chamber temperatures to within 10 C of measured temperatures. To demonstrate the ability of the model under various circumstances the heat flux was examined for a thruster operating in the environment of space.

VanNoord, Jon↗

A Design Tool for Liquid Rocket Engine Injectors

A practical design tool for the analysis of flowfields near the injector face has been developed and used to analyze the Fastrac engine. The objective was to produce a computational design tool which was detailed enough to predict the interactive effects of injector element impingement angles and points and the momenta of the individual orifice flows. To obtain a model which could be used to simulate a significant number of individual orifices, a homogeneous computational fluid dynamics model was developed. To describe liquid and vapor sub- and super-critical flows, the model included thermal and caloric equations of state which were valid over a wide range of pressures and temperatures. A homogeneous model was constructed such that the local state of the flow was determined directly, i.e. the quality of the flow was calculated. Such a model does not identify drops or their distribution, but it does allow the flow along the injector face and into the acoustic cavity to be predicted. It also allows the film coolant flow to be accurately described. The initial evaluation of the injector code was made by simulating cold flow from an unlike injector element and from a like-on-like overlapping fan (LOL) injector element. The predicted mass flux distributions of these injector elements compared well to cold flow test results. These are the same cold flow tests which serve as the data base for the JANNAF performance prediction codes. The flux distributions 1 inch downstream of the injector face are very similar; the differences were somewhat larger at further distances from the faceplate. Since the cold flow testing did not achieve good mass balances when integrations across the entire fan were made, the CFD simulation appears to be reasonable alternative to future cold flow testing. To simulate the Fastrac, an RP-1/LOX combustion model must be chosen. This submodel must be relatively simple to accomplish three-dimensional, multiphase flow simulations. Single RP-1 pyrolysis and partial oxidation steps were chosen and the combustion was completed with the wet CO mechanism. Soot was also formed with a single global reaction. To validate the combustion submodel, global data from gas generator tests and from subscale motor test were used to predict qualitatively correct mean molecular weights, temperature, and soot levels. Because such tests do not provide general kinetics rates, the methodology is not necessarily appropriate for other than rocket type flows conditions. Soot predictions were made so that radiation heating to the motor walls can be made. These initial studies of the Fastrac were for a small region close to the injector face and chamber wall which included a segment of the acoustic cavity. The region analyzed includes 11 individual orifice holes to represent the LOL elements and the H2 film coolant holes. Typical results of this simulation are shown in Figure 1. At this point the only available test data to verify the predictions are temperatures measured in the acoustic cavity. These temperatures are in reasonable agreement at about 2000R (1111 K). Future work is expected to include improving the computational efficiency or the CFD model and/or using more computer capacity than the single Pentium PC with which these simulations were made.

Farmer, Richard C.↗

Real-Time Temperature Field State Observer and Digital Replica to Support Cyber-Physical Testing

Cyber-physical testing is a class of experimental methods in which a system is partitioned into physical and numerical components to study its overall behavior. Transfer systems are typically needed to capture relevant interactions by enforcing appropriate interface conditions between the physical and numerical portions. While cyber-physical testing is often performed using lumped-parameter systems, thermomechanical cyber-physical testing requires the use of thermal actuators as transfer systems to apply a thermal condition over a spatially distributed region or surface. Thus, the interactions between the numerical and physical components are of a distributed nature, i.e., a field rather than point values. In this paper, we develop and experimentally validate a state observer for temperature fields to enable thermomechanical cyber-physical testing. The state observer provides continuous estimates of temperature over a surface of the thermal actuator using only temperature measurements at discrete locations. The estimated temperature field is then leveraged to account for localized mechanical defects in the interface condition. The method consists of building a digital replica of one portion of the control plant. By imposing defects in the digital replica it is used to generate and output the response of a thermal load pattern that represents that of a physical system with mechanical defects.

Manuel Salmeron↗

Multilevel measurements of surface temperature over undulating terrain planted to barley

A ground and aircraft program was conducted to extend ground based methods for measuring soil moisture and crop water stress to aircraft and satellite altitudes. A 260ha agricultural field in California was used over the 1977-78 growing season. For cloud free days ground based temperature measurements over bare soil were related to soil moisture content. Water stress resulted from too much water, not from lack of it, as was expected. A theoretical examination of the canopy air temperature difference as affected by vapor pressure deficit and net radiation was developed. This analysis shows why surface temperatures delineate crop water stress under conditions of low humidity, but not under high humidity conditions. Multilevel temperatures acquired from the ground, low and high altitude aircraft, and the Heat Capacity Mapping Mission (HCMM) spacecraft were compared for two day and one night overpasses. The U-2 and low altitude temperatures were within 0.5 C. The HCMM data were analyzed using both the pre- and post-launch calibrations, with the former being considerably closer in agreement with the aircraft data than the latter.

Reginato, R. J.↗