Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TOMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Fourier-based magnetic induction tomography for mapping resistivity

Magnetic induction tomography is used as an experimental tool for mapping the passive electromagnetic properties of conductors, with the potential for imaging biological tissues. Our numerical approach to solving the inverse problem is to obtain a Fourier expansion of the resistivity and the stream functions of the magnetic fields and eddy current density. Thus, we are able to solve the inverse problem of determining the resistivity from the applied and measured magnetic fields for a two-dimensional conducting plane. When we add noise to the measured magnetic field, we find the fidelity of the measured to the true resistivity is quite robust for increasing levels of noise and increasing distances of the applied and measured field coils from the conducting plane, when properly filtered. We conclude that Fourier methods provide a reliable alternative for solving the inverse problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theoretical and Experimental Study of Optical Coherence Tomography (OCT) Signals Using an Analytical Transport Model

Optical coherence tomography (OCT) is a non-invasive low coherent interferometric technique that provides cross-sectional images of turbid media. OCT is based on the classical Michelson interferometer where the mirror of the reference arm is oscillating and the signal arm contains a biological sample. In this work, we analyzed theoretically the heterodyne optical signal adopting the so called extended Huygens-Fresnel principle (EHFP). We use simulated OCT images with known optical properties to test an algorithm developed by ourselves to recover the scattering coefficient and we recovered the scattering coefficient with a relative error less than 5% for noisy signals. In addition, we applied this algorithm to OCT images from phantoms of known optical properties; in this case curves were indistinguishable. A revision of the validity of the analytical model applied to our system should be done.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effective grain pinning revealed by nanoscale electron tomography

The grain pinning behavior of TiC particles in a rapidly solidified MRE-Fe-B (MRE = Nd + Y + Dy) nanocrystalline hard magnet was studied using electron tomography (ET). The 3D reconstruction overcomes the inherent 2D nature of conventional transmission electronmicroscopy (TEM) to reveal how this grain boundary phase controls the nanoscale structure in the rapidly solidified alloy. The 3D reconstruction was performed on the optimally annealed alloy (750 C/15 min) with hard magnetic properties of M{sub r} = 8.1 kGs, H{sub c} = 6.2 kOe, (BH){sub max} = 11.2 MGOe measured at 300 k. The sampled volume, 425 x 425 x 92.5 nm{sup 3}, contains more than 20 grains of the RE2-14-1 phase and more than 70 TiC nanoparticles. The TiC grains shapes depend on their sizes and locations along the grain boundary. Most of the TiC particles are oval or short rod like shapes and range from 5 nm to 10 nm. TiC particles less than 10 nm formed between adjacent 2-14-1 grains, while the largest ones formed at triple junctions. There are -1.7 x 10{sup 8} TiC particles within a 1 mm{sup 3} volume in the alloy. This accounts for the strong grain boundary pinning effect, which limits grain growth during annealing.

36 MATERIALS SCIENCE↗

Performance of a Drift Chamber Candidate for a Cosmic Muon Tomography System

In the last decade, many groups around the world have been exploring different ways to probe transport containers which may contain illicit Special Nuclear Materials such as uranium. The muon tomography technique has been proposed as a cost effective system with an acceptable accuracy. A group of Canadian institutions (see above), funded by Defence Research and Development Canada, is testing different technologies to track the cosmic muons. One candidate is the single wire Drift Chamber. With the capability of a 2D impact position measurement, two detectors will be placed above and two below the object to be probed. In order to achieve a good 3D image quality of the cargo content, a good angular resolution is required. The simulation showed that 1mrad was required implying the spatial resolution of the trackers must be in the range of 1 to 2 mm for 1 m separation. A tracking system using three prototypes has been built and tested. The spatial resolution obtained is 1.7 mm perpendicular to the wire and 3 mm along the wire.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dopant characterization in self-regulatory plasma doped fin field-effect transistors by atom probe tomography

Fin field-effect transistors are promising next-generation electronic devices, and the identification of dopant positions is important for their accurate characterization. We report atom probe tomography (APT) of silicon fin structures prepared by a recently developed self-regulatory plasma doping (SRPD) technique. Trenches between fin-arrays were filled using a low-energy focused ion beam to directly deposit silicon, which allowed the analysis of dopant distribution by APT near the surface of an actual fin transistor exposed to air. We directly demonstrate that SRPD can achieve a boron concentration above 1 x 10{sup 20} atoms/cm{sup 3} at the fin sidewall.

36 MATERIALS SCIENCE↗

Soft x-ray tomography for real-time applications: present status at Tore Supra and possible future developments

This paper is focused on the soft x-ray (SXR) tomography system setup at Tore Supra (DTOMOX) and the recent developments made to automatically get precise information about plasma features from inverted data. The first part describes the main aspects of the tomographic inversion optimization process. Several observations are made using this new tool and a set of shape factors is defined to help characterizing the emissivity field in a real-time perspective. The second part presents a detailed off-line analysis comparing the positions of the magnetic axis obtained from a magnetic equilibrium solver, and the maximum of the reconstructed emissivity field for ohmic and heated pulses. A systematic discrepancy of about 5 cm is found in both cases and it is shown that this discrepancy increases during sawtooth crashes. Finally, evidence of radially localized tungsten accumulation with an in-out asymmetry during a lower hybrid current drive pulse is provided to illustrate the DTOMOX capabilities for a precise observation of local phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introducing minimum Fisher regularisation tomography to AXUV and soft x-ray diagnostic systems of the COMPASS tokamak

The contribution focuses on plasma tomography via the minimum Fisher regularisation (MFR) algorithm applied on data from the recently commissioned tomographic diagnostics on the COMPASS tokamak. The MFR expertise is based on previous applications at Joint European Torus (JET), as exemplified in a new case study of the plasma position analyses based on JET soft x-ray (SXR) tomographic reconstruction. Subsequent application of the MFR algorithm on COMPASS data from cameras with absolute extreme ultraviolet (AXUV) photodiodes disclosed a peaked radiating region near the limiter. Moreover, its time evolution indicates transient plasma edge cooling following a radial plasma shift. In the SXR data, MFR demonstrated that a high resolution plasma positioning independent of the magnetic diagnostics would be possible provided that a proper calibration of the cameras on an x-ray source is undertaken.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of a polychromatic tomography method for the extraction of the three-dimensional spatial structure of implosion core plasmas

A spectroscopic method has been developed to extract the three-dimentional spatial structure (i.e., spatial distribution of electron temperature and density) of inertial confinement fusion implosion cores based on the analysis of space-resolved spectra from a tracer element recorded along three quasi-orthogonal lines of sight. We discuss a spectral model that computes space-resolved spectra for a given spatial structure. This model is then combined with a multi-objective search and optimization technique driven by a Pareto genetic algorithm to perform the inversion and to extract the spatial structure of the implosion core from a simultaneous and self-consistent analysis of a set of space-resolved spectra. This method is investigated with a series of synthetic data test cases to explore its reliability, requirements, and limitations. We have found a constraint parameter P{sub const} such that the method is robust and the extracted spatial structure is reliable when P{sub const}> 1. The idea of polychromatic tomography is general and has potential to extract the spatial structure of other laboratory high energy-density plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of plasma-doped fin structure and characterization of dopants by atom probe tomography

As and P dopants in a plasma-doped Si-based fin structure were analyzed using atom probe tomography. The distributions and concentrations of As and P atoms in various regions of the fin structure and the oxidation levels for different dopants were determined. Most dopants were segregated at the fin boundary, and the As and P concentrations exceeded 9 Multiplication-Sign 10{sup 20} atoms/cm{sup 3} and 2 Multiplication-Sign 10{sup 20} atoms/cm{sup 3}, respectively. The atomic oxygen and SiO{sub 2} concentrations depended on the dopant type. The larger and heavier As dopant severely damaged the surface of the fin structure and could cause more severe oxidation.

36 MATERIALS SCIENCE↗

A fast-converging iterative method for X-ray in-line phase contrast tomography

X-ray in-line phase contrast tomography holds great promise for the quantitative analysis of soft materials. However, its applications have been limited, so far, by the fact that direct methods based on the transport-of-intensity equation and the contrast transfer function are sensitive to noise and applicable only to limited types of samples. Here, we propose an iterative method based on the Gerchberg-Saxton algorithm (R. W. Gerchberg and W. O. Saxton, Optik 35, 237 (1972)), but overcoming its slow convergence by an acceleration technique, named random signed feedback, which shows an excellent performance, both in numerical simulation and tomographic experiment, of discriminating various polymers even when using 53 keV synchrotron X-rays.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic-scale characterization of germanium isotopic multilayers by atom probe tomography

We report comparison of the interfacial sharpness characterization of germanium (Ge) isotopic multilayers between laser-assisted atom probe tomography (APT) and secondary ion mass spectrometry (SIMS). An alternating stack of 8-nm-thick naturally available Ge layers and 8-nm-thick isotopically enriched {sup 70}Ge layers was prepared on a Ge(100) substrate by molecular beam epitaxy. The APT mass spectra consist of clearly resolved peaks of five stable Ge isotopes ({sup 70}Ge, {sup 72}Ge, {sup 73}Ge, {sup 74}Ge, and {sup 76}Ge). The degree of intermixing at the interfaces between adjacent layers was determined by APT to be around 0.8 {+-} 0.1 nm which was much sharper than that obtained by SIMS.

36 MATERIALS SCIENCE↗

Magnetic field calculation for a 10 MeV positron emission tomography cyclotron

The magnetic field calculation and correction for a 10 MeV positron emission tomography cyclotron is presented. 3D TOSCA analysis results are compared with the measured data, and the calculation error is used to calibrate the B-H curve to obtain a very precise finite element method estimator, which is used to predict the correction of the magnet pole for achieving the isochronous field. The isochronous field error is approximated with the effects of a set of standard patches. On the assumption that the effect of each small patch is proportional to its surface, the correction of the magnet pole is found by solving a system of equations using the least square scheme. The magnet shimming is performed and the measured magnetic field is found in good agreement with the prediction, with an error less than 2 G.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined synchrotron X-ray tomography and X-ray powder diffraction using a fluorescing metal foil

This study realizes the concept of simultaneous micro-X-ray computed tomography and X-ray powder diffraction using a synchrotron beamline. A thin zinc metal foil was placed in the primary, monochromatic synchrotron beam to generate a divergent wave to propagate through the samples of interest onto a CCD detector for tomographic imaging, thus removing the need for large beam illumination and high spatial resolution detection. Both low density materials (kapton tubing and a piece of plant) and higher density materials (Egyptian faience) were investigated, and elemental contrast was explored for the example of Cu and Ni meshes. The viability of parallel powder diffraction using the direct beam transmitted through the foil was demonstrated. The outcomes of this study enable further development of the technique towards in situ tomography/diffraction studies combining micrometer and crystallographic length scales, and towards elemental contrast imaging and reconstruction methods using well defined fluorescence outputs from combinations of known fluorescence targets (elements).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian soft X-ray tomography using non-stationary Gaussian Processes

In this study, a Bayesian based non-stationary Gaussian Process (GP) method for the inference of soft X-ray emissivity distribution along with its associated uncertainties has been developed. For the investigation of equilibrium condition and fast magnetohydrodynamic behaviors in nuclear fusion plasmas, it is of importance to infer, especially in the plasma center, spatially resolved soft X-ray profiles from a limited number of noisy line integral measurements. For this ill-posed inversion problem, Bayesian probability theory can provide a posterior probability distribution over all possible solutions under given model assumptions. Specifically, the use of a non-stationary GP to model the emission allows the model to adapt to the varying length scales of the underlying diffusion process. In contrast to other conventional methods, the prior regularization is realized in a probability form which enhances the capability of uncertainty analysis, in consequence, scientists who concern the reliability of their results will benefit from it. Under the assumption of normally distributed noise, the posterior distribution evaluated at a discrete number of points becomes a multivariate normal distribution whose mean and covariance are analytically available, making inversions and calculation of uncertainty fast. Additionally, the hyper-parameters embedded in the model assumption can be optimized through a Bayesian Occam's Razor formalism and thereby automatically adjust the model complexity. This method is shown to produce convincing reconstructions and good agreements with independently calculated results from the Maximum Entropy and Equilibrium-Based Iterative Tomography Algorithm methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase contrast tomography of the mouse cochlea at microfocus x-ray sources

We present phase contrast x-ray tomography of functional soft tissue within the bony cochlear capsule of mice, carried out at laboratory microfocus sources with well-matched source, detector, geometry, and reconstruction algorithms at spatial resolutions down to 2 μm. Contrast, data quality and resolution enable the visualization of thin membranes and nerve fibers as well as automated segmentation of surrounding bone. By complementing synchrotron radiation imaging techniques, a broad range of biomedical applications becomes possible as demonstrated for optogenetic cochlear implant research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigating the effect of characteristic x-rays in cadmium zinc telluride detectors under breast computerized tomography operating conditions

A number of research groups have been investigating the use of dedicated breast computerized tomography (CT). Preliminary results have been encouraging, suggesting an improved visualization of masses on breast CT as compared to conventional mammography. Nonetheless, there are many challenges to overcome before breast CT can become a routine clinical reality. One potential improvement over current breast CT prototypes would be the use of photon counting detectors with cadmium zinc telluride (CZT) (or CdTe) semiconductor material. These detectors can operate at room temperature and provide high detection efficiency and the capability of multi-energy imaging; however, one factor in particular that limits image quality is the emission of characteristic x-rays. In this study, the degradative effects of characteristic x-rays are examined when using a CZT detector under breast CT operating conditions. Monte Carlo simulation software was used to evaluate the effect of characteristic x-rays and the detector element size on spatial and spectral resolution for a CZT detector used under breast CT operating conditions. In particular, lower kVp spectra and thinner CZT thicknesses were studied than that typically used with CZT based conventional CT detectors. In addition, the effect of characteristic x-rays on the accuracy of material decomposition in spectral CT imaging was explored. It was observed that when imaging with 50-60 kVp spectra, the x-ray transmission through CZT was very low for all detector thicknesses studied (0.5–3.0 mm), thus retaining dose efficiency. As expected, characteristic x-ray escape from the detector element of x-ray interaction increased with decreasing detector element size, approaching a 50% escape fraction for a 100 μm size detector element. The detector point spread function was observed to have only minor degradation with detector element size greater than 200 μm and lower kV settings. Characteristic x-rays produced increasing distortion in the spectral response with decreasing detector element size. If not corrected for, this caused a large bias in estimating tissue density parameters for material decomposition. It was also observed that degradation of the spectral response due to characteristic x-rays caused worsening precision in the estimation of tissue density parameters. It was observed that characteristic x-rays do cause some degradation in the spatial and spectral resolution of thin CZT detectors operating under breast CT conditions. These degradations should be manageable with careful selection of the detector element size. Even with the observed spectral distortion from characteristic x-rays, it is still possible to correctly estimate tissue parameters for material decomposition using spectral CT if accurate modeling is used.

36 MATERIALS SCIENCE↗

Low background high efficiency radiocesium detection system based on positron emission tomography technology

After the 2011 nuclear power plant accident at Fukushima, radiocesium contamination in food became a serious concern in Japan. However, low background and high efficiency radiocesium detectors are expensive and huge, including semiconductor germanium detectors. To solve this problem, we developed a radiocesium detector by employing positron emission tomography (PET) technology. Because {sup 134}Cs emits two gamma photons (795 and 605 keV) within 5 ps, they can selectively be measured with coincidence. Such major environmental gamma photons as {sup 40}K (1.46 MeV) are single photon emitters and a coincidence measurement reduces the detection limit of radiocesium detectors. We arranged eight sets of Bi{sub 4}Ge{sub 3}O{sub 12} (BGO) scintillation detectors in double rings (four for each ring) and measured the coincidence between these detectors using PET data acquisition system. A 50 × 50 × 30 mm BGO was optically coupled to a 2 in. square photomultiplier tube (PMT). By measuring the coincidence, we eliminated most single gamma photons from the energy distribution and only detected those from {sup 134}Cs at an average efficiency of 12%. The minimum detectable concentration of the system for the 100 s acquisition time is less than half of the food monitor requirements in Japan (25 Bq/kg). These results show that the developed radiocesium detector based on PET technology is promising to detect low level radiocesium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An image filtering technique for SPIDER visible tomography

The tomographic diagnostic developed for the beam generated in the SPIDER facility (100 keV, 50 A prototype negative ion source of ITER neutral beam injector) will characterize the two-dimensional particle density distribution of the beam. The simulations described in the paper show that instrumental noise has a large influence on the maximum achievable resolution of the diagnostic. To reduce its impact on beam pattern reconstruction, a filtering technique has been adapted and implemented in the tomography code. This technique is applied to the simulated tomographic reconstruction of the SPIDER beam, and the main results are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗