Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TABLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

SU-D-206-05: A Critical Look at CBCT-Based Dose Calculation Accuracy as It Is Applied to Adaptive Radiotherapy

Purpose: Cone-beam CTs (CBCT) obtained from On-Board Imaging Devices (OBI) are increasingly being used for dose calculation purposes in adaptive radiotherapy. Patient and target morphology are monitored and the treatment plan is updated using CBCT. Due to the difference in image acquisition parameters, dose calculated in a CBCT can differ from planned dose. We evaluate the difference between dose calculation in kV CBCT and simulation CT, and the effect of HU-density tables in dose discrepancies Methods: HU values for various materials were obtained using a Catphan 504 phantom for a simulator CT (CTSIM) and two different OBI systems using three imaging protocols: Head, Thorax and Pelvis. HU-density tables were created in the TPS for each OBI image protocol. Treatment plans were made on each Catphan 504 dataset and on the head, thorax and pelvis sections of an anthropomorphic phantom, with and without the respective HU-density table. DVH information was compared among OBI systems and planning CT. Results: Dose calculations carried on the Catphan 504 CBCTs, with and without the respective CT-density table, had a maximum difference of −0.65% from the values on the planning CT. The use of the respective HU-density table decreased the percent differences from planned values by half in most of the protocols. For the anthropomorphic phantom datasets, the use of the correct HU-density table reduced differences by 0.89% on OBI1 and 0.59% on OBI2 for the head, 0.49% on OBI1 for the thorax, and 0.25% on OBI2 for the pelvis. Differences from planned values without HU-density correction ranged from 3.13% (OBI1, thorax) to 0.30% (OBI2, thorax). Conclusion: CT-density tables in the TPS yield acceptable differences when used in partly homogeneous medium. Further corrections are needed when the medium contains pronounced density differences for accurate CBCT calculation. Current difference range (1–3%) can be clinically acceptable.

60 APPLIED LIFE SCIENCES↗

SU-F-P-44: A Direct Estimate of Peak Skin Dose for Interventional Fluoroscopy Procedures

Purpose: There is an increasing demand for medical physicist to calculate peak skin dose (PSD) for interventional fluoroscopy procedures. The dose information (Dose-Area-Product and Air Kerma) displayed in the console cannot directly be used for this purpose. Our clinical experience shows that the use of the existing methods may overestimate or underestimate PSD. This study attempts to develop a direct estimate of PSD from the displayed dose metrics. Methods: An anthropomorphic torso phantom was used for dose measurements for a common fluoroscopic procedure. Entrance skin doses were measured with a Piranha solid state point detector placed on the table surface below the torso phantom. An initial “reference dose rate” (RE) measurement was conducted by comparing the displayed dose rate (mGy/min) to the dose rate measured. The distance from table top to focal spot was taken as the reference distance (RD at the RE. Table height was then adjusted. The displayed air kerma and DAP were recorded and sent to three physicists to estimate PSD. An inverse square correction was applied to correct displayed air kerma at various table heights. The PSD estimated by physicists and the PSD by the proposed method were then compared with the measurements. The estimated DAPs were compared to displayed DAP readings (mGycm2). Results: The difference between estimated PSD by the proposed method and direct measurements was less than 5%. For the same set of data, the estimated PSD by each of three physicists is different from measurements by ±52%. The DAP calculated by the proposed method and displayed DAP readings in the console is less than 20% at various table heights. Conclusion: PSD may be simply estimated from displayed air kerma or DAP if the distance between table top and tube focal spot or if x-ray beam area on table top is available.

60 APPLIED LIFE SCIENCES↗

eCo-Pylot - A Python-Based Script for Sending Parsed Email Data to a Database

eCo-PylotDB, written completely in Python, provides a script that parses incoming emails and prepares extracted data for submission to a database table. The script extracts the database server, the database table, the server password, and the server username all from the email address to which the email is sent. The database table is specified on the Subject line. Any text in the body of the email is extracted as user comments for the database table. Attached files are extracted as data files with each file submitted to a specified table field but in separate rows of the targeted database table. Other information such as sender, date, time, and machine from which the email was sent is extracted and submitted to the database table as well. An email is sent back to the user specifying whether the data from the initial email was accepted or rejected by the database server. If rejected, the return email includes details as to why.

Barnette, DanielW.↗

RLUOB Toppled Load: Near Miss to Personnel Injury (Incident Investigation Final Report)

On Monday, February 25, 2019, at approximately 1430, the Logistics Central Shop (LOG-CS) Hoisting and Rigging (H&R) crew moved an anti-vibration table on the first floor of Technical Area 55 (TA-55), Building 400, Radiological Laboratory/Utilities/Office Building (RLUOB). The table was designed to be anchored to the facility floor on pedestals to provide vibration dampening for an electron microscope (SEM/TEM). The table was approximately 86 inches wide by 56 inches tall, an asymmetrical load. It weighed approximately 2,300 pounds. The crew was transporting the load using a lifting device, specifically a Vere Optical Table Hoist. The work control package (Integrated Work Document [IWD] and H&R Ordinary Lift Plan) included staging the table, moving the load from the loading dock through corridors into a laboratory, and installing the table. During the table move, the riggers made adjustments to the lifting device to enable the load and device to pass through security double doors. After the crew successfully passed through the security double doors, three riggers moved the load approximately ten linear feet further at which point the lifting device and load fell to the RLUOB facility floor. No injuries were sustained as a result of the toppled load and frame. The rigging crew immediately notified supervision who then notified the TA-55 Facility Operations Director (FOD). After further review, the TA-55 FOD categorized the event as a near miss to personnel injury. The scene was preserved and all H&R operations within the TA-55 directorate were paused pending a review of all lift plans with the rigging supervisor and the Chemistry and Metallurgy Research Replacement (CMRR) Construction Manager. All lift plans were to be reviewed prior to resumption of H&R lifts within the directorate. Additionally, all newly generated lift plans will be reviewed by the TA-55 FOD, the H&R supervisor and the affected manager. The Associate Laboratory Director for Weapons Production (ALDWP) appointed a team to investigate the event, identify all relevant facts, and determine the direct, contributing, and root causes. The team was also charged with reviewing other similar events to identify common causes for multiple recurring events and the organizational and management weaknesses that have led to failure to correct recurring events. (See Appendix A: Memo, Appointment of Accident Investigation Board.)

99 GENERAL AND MISCELLANEOUS↗

Transportation Energy: A Comparison Including and Excluding Upstream Energy

Thirty-eight editions of the Transportation Energy Data Book (Data Book) have been published since the report began in 1976. It was designed as a desk-top reference of statistics and information that characterize transportation activity. The most recent Data Book, edition 38, has 226 tables and 70 figures in the body of the report, with an additional 51 tables in appendices. One of the most-often used tables in the Data Book is referred to by the authors as “the big energy table.” It has transportation energy use in British thermal units (Btu) by mode and fuel type. The data are compiled from about 20 different sources and combined to create a detailed picture of transportation energy use. From the first edition to edition 35 of the Data Book, electricity use in the big energy table was converted from the original kilowatt-hours (kWh) to Btu using the net generation heat rate for fossil fuels. In those days, electricity was used mainly by transit rail. As electricity began to be used in the highway modes with consumer sales of electric vehicles, that process was revisited. Since energy use in the Data Book’s big energy table for all other fuels did not include the upstream energy to create the fuel, it seemed inconsistent to include upstream energy for generation of electricity. Beginning with edition 36, electricity use for the big energy table was converted from kilowatt hours to Btu using the heat content of electricity. Using heat content instead of net generation reduced electricity use data by about two-thirds. Feedback in recent years on the change in process for electricity led to an investigation of the differences in transportation energy use when adding estimates of upstream energy use to all the fuels used in transportation. This report documents the result of that effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Update to the Finite Cloud Dose Correction Factors in MACCS

In WASH - 1400, external exposure from the finite radioactive cloud (cloudshine) is calculated by assuming that the cloud is semi-infinite, the concentration of radioactive material is uniform, and by using a correction factor to account for these approximations. This correction factor is originally based upon formulations by Healy and depends on the effective size of the plume and the distance from the plume center to the receptor. The range of the finite cloud dose correction factor table from WASH - 1400 developed using Healy formulations can be exceeded in certain situations. When the range of the table is exceeded, no extrapolation is performed; rather interpolation at the edge of the table is performed per WASH - 1400. The tabulated values of these finite cloud dose correction factors from WASH - 1400 and the interpolation at the edge of the table have been used in MACCS since its creation. An expanded table of finite cloud dose correction factors is one way to reduce the need of using interpolation at the edge of the table. The generation of an expanded finite cloud dose correction factor table for future use in MACCS is documented in this report.

54 ENVIRONMENTAL SCIENCES↗

Extending and Smoothing Two-dimension Equation of State Simulation Data

The Multiphase Equation of State (MEOS) project works to produce high quality equation of state tables which are used in computationally intensive simulations of materials in different conditions. An equation of state table describes the state of matter under certain physical conditions such as pressure, volume, temperature, or internal energy. MEOS uses many different models and combinations thereof to produce accurate tables consisting of continuous smooth data, derivatives, and higher-order derivatives. Accurate and smooth data are important factors in producing precise simulations. This report focuses on improving the electron tables produced from Purgatorio and Thomas-Fermi data. Purgatorio data is extremely accurate but often jagged and discontinuous in the lower temperature and density region. Thomas-Fermi is a model that provides smooth data throughout. Together, this produces an EOS data table that is both accurate and smooth. This report describes the implementation of a new feature that allows users to define more detailed regions in the Purgatorio table to be replaced with Thomas-Fermi. As a result, MEOS can generate a table that is both more smooth and still accurate.

97 MATHEMATICS AND COMPUTING↗

Evaluation of Howard A. Hanson Dam Juvenile Fish Passage and Survival Study Live Fish Injury Assessment, Sensor Fish, and BioPA Modeling Tasks

The live fish injury assessment, Sensor Fish, and BioPA modeling study tasks were conducted by researchers from Pacific Northwest National Laboratory (PNNL). The four tasks were part of the larger Evaluation of Howard A. Hanson Dam (HAHD) Juvenile Fish Passage and Survival study, which had six total tasks. To achieve study objectives for each of the four tasks, field work occurred at Green Peter Dam (GPR) to evaluate the highest elevation steep slope bypass pipe, at HAHD to evaluate baseline conditions of the horseshoe tunnel, and at PNNL’s Aquatic Research Laboratory (ARL) to evaluate simulated dam passage conditions (i.e., shear forces and collision). Each of these evaluations utilized live fish injury assessment, Sensor Fish, and BioPA modeling. Live fish injury assessment and survival (tagged with and without balloon or passive integrated transponder [PIT] tags) was correlated with Sensor Fish to determine thresholds. The CFD analyses were then performed, and the computed values were compared to the corresponding measured values of Sensor Fish data. The results of the overall injury and survival of fish was also used in the validation of the CFD modeling method. Collectively, the results will aid in future modeling of fish passage at HAHD. Results from these tasks can be used by biologists, engineers, resource managers, and regional decision-makers to inform baseline conditions under current operations and the engineering design of the new FPF at HAHD. This draft report contains initial data and results from the four tasks. Table 8 1, Table 8 2, and Table 8 3, and Figure 8 1, Figure 8 2, and Figure 8 3 depict the CFD modeling findings for the GPR steep slope bypass, HAHD horseshoe tunnel, and laboratory testing. Table 8 4, Table 8 5, and Table 8 6 depict the Sensor Fish findings for the GPR steep slope bypass and HAHD horseshoe tunnel testing. The Mv values observed in the HAHD were significantly lower compared to the laboratory experiments conducted at PNNL. Currently, investigations are underway to understand the reasons for this disparity and to establish an appropriate threshold value for Mv. Survival predictions presented in the tables below should be considered preliminary and should not be used until further analyses and adjustments are completed. The next steps for modeling will include the flow regime, (i.e., density of flow regimes due to water and air mixing ) to continue to improve on the threshold value for Mv.

13 HYDRO ENERGY↗

The Dose Rate Conversion Factors for Nuclear Fallout

In a previous paper, the composite exposure rate conversion factor (ECF) for nuclear fallout was calculated using a simple theoretical photon-transport model. The theoretical model was used to fill in the gaps in the FGR-12 table generated by ORNL. The FGR-12 table contains the individual conversion factors for approximate 1000 radionuclides. However, in order to calculate the exposure rate during the first 30 minutes following a nuclear detonation, the conversion factors for approximately 2000 radionuclides are needed. From a human-effects standpoint, it is also necessary to have the dose rate conversion factors (DCFs) for all 2000 radionuclides. The DCFs are used to predict the whole-body dose rates that would occur if a human were standing in a radiation field of known exposure rate. As calculated by ORNL, the whole-body dose rate (rem/hr) is approximately 70% of the exposure rate (R/hr) at one meter above the surface. Hence, the individual DCFs could be estimated by multiplying the individual ECFs by 0.7. Although this is a handy rule-of-thumb, a more consistent (and perhaps, more accurate) method of estimating the individual DCFs for the missing radionuclides in the FGR-12 table is to use the linear relationship between DCF and total gamma energy released per decay. This relationship is shown in Figure 1. The DCFs for individual organs in the body can also be estimated from the estimated whole-body DCF. Using the DCFs given FGR-12, the ratio of the organ-specific DCFs to the whole-body DCF were plotted as a function of the whole-body DCF. From these plots, the asymptotic ratios were obtained (see Table 1). Using these asymptotic ratios, the organ-specific DCFs can be estimated using the estimated whole-body DCF for each of the missing radionuclides in the FGR-12 table. Although this procedure for estimating the organ-specific DCFs may over-estimate the value for some low gamma-energy emitters, having a finite value for the organ-specific DCFs in the table is probably better than having no value at all. A summary of the complete ECF and DCF values are given in Table 2.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Dynamic Characterization of NASA Armstrong Test Facility Mechanical Vibration Facility

In preparation for Sierra Nevada Corporation’s (SNC) Dream Chaser spacecraft vibration test campaign at NASA Armstrong Test Facility (ATF) in Sandusky, Ohio, a dynamic characterization of the Mechanical Vibration Facility (MVF) is currently ongoing. The Mechanical Vibration Facility is comprised of an 18 ft diameter annulus table that is driven with sixteen hydraulic vertical actuator assemblies and four hydraulic horizontal actuator assemblies. During a test campaign this allows for single axis vibration testing in the vertical axis and in each of the two orthogonal horizontal axes without the need for reconfiguring the test article. The dynamic characterization of the facility was defined to follow a building-block approach requiring three vibration test configurations: (1) MVF bare table (2) MVF table and head expander (3) MVF table, head expander, and a dummy test article. Following the completion of the facility dynamic characterization, a facility finite element model (FEM) will be test-verified allowing for more accurate pretest analysis used for determining response limits and abort levels. To date two of the three test configurations have been completed. Test results have been used to verify the facility FEM that includes both the 18 ft diameter annulus table and the aluminum head expander that fills in the center opening of the annulus to provide a continuous flat mounting surface. Both the MVF table and the head expander models were previously correlated using test results from free-free boundary condition modal tests so model updates to the facility FEM focused on the uncorrelated vertical actuator assemblies and horizontal actuator assemblies. The accuracy of the test-verified facility FEM will be further determined based on comparison of analytical and test results from the vibration test of the dummy test article. Efforts will also be made to determine fixed base modes of the test article attached to the flexible vibration table using fixed base correction techniques. This paper will discuss test and analytical results from the MVF dynamic characterization test sequence and corresponding model updating effort.

Emma L Pierson↗

Evaluation of a six-DOF electrodynamic shaker system.

The paper describes the preliminary evaluation of a 6 degree of freedom electrodynamic shaker system. The 8 by 8 inch (20.3 cm) table is driven by 12 electrodynamic shakers producing motion in all 6 rigid body modes. A small electrodynamic shaker system suitable for small component testing is described. The principal purpose of the system is to demonstrate the technology. The shaker is driven by 12 electrodynamic shakers each with a force capability of about 50 lbs (220 N). The system was developed through an informal cooperative agreement between Sandia National Laboratories, Team Corp. and Spectral Dynamics Corporation. Sandia provided the laboratory space and some development funds. Team provided the mechanical system, and Spectral Dynamics provided the control system. Spectral Dynamics was chosen to provide the control system partly because of their experience in MIMO control and partly because Sandia already had part of the system in house. The shaker system was conceived and manufactured by TEAM Corp. Figure 1 shows the overall system. The vibration table, electrodynamic shakers, hydraulic pumps, and amplifiers are all housed in a single cabinet. Figure 2 is a drawing showing how the electrodynamic shakers are coupled to the table. The shakers are coupled to the table through a hydraulic spherical pad bearing providing 5 degrees of freedom and one stiff degree of freedom. The pad bearing must be preloaded with a static force as they are unable to provide any tension forces. The horizontal bearings are preloaded with steel springs. The drawing shows a spring providing the vertical preload. This was changed in the final design. The vertical preload is provided by multiple strands of an O-ring material as shown in Figure 4. Four shakers provide excitation in each of the three orthogonal axes. The specifications of the shaker are outlined in Table 1. Four shakers provide inputs in each of the three orthogonal directions. By choosing the phase relationships between the shakers all six rigid body modes (three translation, and three rotations) can be excited. The system is over determined. There are more shakers than degrees of freedom. This provided an interesting control problem. The problem was approached using the input-output transformation matrices provided in the Spectral control system. Twelve accelerometers were selected for the control accelerometers (a tri-axial accelerometer at each corner of the table (see Figure 5). Figure 6 shows the nomenclature used to identify the shakers and control accelerometers. A fifth tri-axial accelerometer was placed at the center of the table, but it was not used for control. Thus we had 12 control accelerometers and 12 shakers to control a 6-dof shaker. The 12 control channels were reduced to a 6-dof control using a simple input transformation matrix. The control was defined by a 6x6 spectral density matrix. The six outputs in the control variable coordinates were transformed to twelve physical drive signals using another simple output transformation matrix. It was assumed that the accelerometers and shakers were well matched such that the transformation matrices were independent of frequency and could be deduced from rigid body considerations. The input/output transformations are shown in Equations 1 and 2.

36 MATERIALS SCIENCE↗

Zero-Kelvin Compression Isotherms of the Elements 1 ≤ Z ≤ 92 to 100 GPa

Most of the chemical elements have now been compressed close to or above 100 GPa (1 Mbar) pressure in diamond-anvil cells and the pressure–volume room-temperature isotherms have been measured. We collect these data and use simple lattice-dynamics models to reduce the isotherms to 0 K. We have extended the published work by making new diamond-anvil-cell measurements on Cr and Rh, and by conducting density-functional calculations on the elements Po, At, Rn, Fr, Ra, and Ac. The 0 K data are tabulated for all elements 1 ≤ Z ≤ 92 and 0 ≤ P ≤ 100 GPa. These data are useful for generating wide-range equation of state models and for studying the stability of chemical compounds at high pressure (“Megabar chemistry”). The tables presented here are intended to be reference thermodynamic tables for use in high-pressure research. Further experimental and theoretical work will be needed to extend the tables to higher pressure and to improve accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Global‐view coefficients: a data management solution for parallel quantum Monte Carlo applications

Summary Quantum Monte Carlo (QMC) applications perform simulation with respect to an initial state of the quantum mechanical system, which is often captured by using a cubic B‐spline basis. This representation is stored as a read‐only table of coefficients and accesses to the table are generated at random as part of the Monte Carlo simulation. Current QMC applications, such as QWalk and QMCPACK, replicate this table at every process or node, which limits scalability because increasing the number of processors does not enable larger systems to be run. We present a partitioned global address space approach to transparently managing this data using Global Arrays in a manner that allows the memory of multiple nodes to be aggregated. We develop an automated data management system that significantly reduces communication overheads, enabling new capabilities for QMC codes. Experimental results with QWalk and QMCPACK demonstrate the effectiveness of the data management system. Copyright © 2016 John Wiley & Sons, Ltd.

Niu, Qingpeng↗

Influence of hydrological, biogeochemical and temperature transients on subsurface carbon fluxes in a flood plain environment

Flood plains play a potentially important role in the global carbon cycle. The accumulation of organic matter in flood plains often induces the formation of chemically reduced groundwater and sediments along riverbanks. In this study, our objective is to evaluate the cumulative impact of such reduced zones, water table fluctuations, and temperature gradients on subsurface carbon fluxes in a flood plain at Rifle, Colorado located along the Colorado River. 2-D coupled variably-saturated, non-isothermal flow and biogeochemical reactive transport modeling was applied to improve our understanding of the abiotic and microbially mediated reactions controlling carbon dynamics at the Rifle site. Model simulations considering only abiotic reactions (thus ignoring microbial reactions) underestimated CO 2 partial pressures observed in the unsaturated zone and severely underestimated inorganic (and overestimated organic) carbon fluxes to the river compared to simulations with biotic pathways. Both model simulations and field observations highlighted the need to include microbial contributions from chemolithoautotrophic processes (e.g., Fe +2 and S -2 oxidation) to match locally-observed high CO 2 concentrations above reduced zones. Observed seasonal variations in CO 2 concentrations in the unsaturated zone could not be reproduced without incorporating temperature gradients in the simulations. Incorporating temperature fluctuations resulted in an increase in the annual groundwater carbon fluxes to the river by 170 % to 3.3 g m -2 d -1 , while including water table variations resulted in an overall decrease in the simulated fluxes. We thus conclude that spatial microbial and redox zonation as well as temporal fluctuations of temperature and water table depth contribute significantly to subsurface carbon fluxes in flood plains and need to be represented appropriately in model simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GraphTango: A Hybrid Representation Format for Efficient Streaming Graph Updates and Analysis

Abstract Streaming graph processing performs batched updates and analytics on a time-evolving graph. The underlying representation format of the graph largely determines the throughputs of these updates and analytics phases. Existing representation formats usually employ variations of hash tables or adjacency lists. However, a recent study showed that the adjacency-list-based approaches perform poorly on heavy-tailed graphs, and the hash table-based approaches suffer on short-tailed graphs. We propose GraphTango, a hybrid representation format that provides excellent update and analytics throughput regardless of the graph’s degree distribution. GraphTango dynamically switches among three different formats based on a vertex’s degree: (i) Low-degree vertices store the edges directly with the neighborhood metadata, confining accesses to a single cache line, (2) Medium-degree vertices use adjacency lists, and (3) High-degree vertices use hash tables as well as adjacency lists. In this case, the adjacency list provides fast traversal during the analytics phase, while the hash table provides constant-time lookups during the update phase. We further optimized the performance by designing an open-addressing-based hash table that fully utilizes every fetched cache line. In addition, we developed a thread-local lock-free memory pool that allows fast growing/shrinking of the adjacency lists and hash tables in a multi-threaded environment. We evaluated GraphTango with the help of the SAGA-Bench framework and compared it with four other representation formats: Stinger, Degree-aware Robin Hood Hashing, and two adjacency list-based formats with different workload balancing scheme. On average, GraphTango provides 4.5x higher insertion throughput, 3.2x higher deletion throughput, and 1.1x higher analytics throughput over the next best format. Furthermore, we integrated GraphTango with the state-of-the-art graph processing frameworks DZiG and RisGraph. Compared to the vanilla DZiG and vanilla RisGraph , [ GraphTango + DZiG ] and [ GraphTango + RisGraph ] reduces the average batch processing time by 2.3x and 1.5x, respectively.

Ahmed, Alif↗

Ergodicity of the generalized lemon billiards

In this paper, we study a two-parameter family of convex billiard tables, by taking the intersection of two round disks (with different radii) in the plane. These tables give a generalization of the one-parameter family of lemon-shaped billiards. Initially, there is only one ergodic table among all lemon tables. In our generalized family, we observe numerically the prevalence of ergodicity among the some perturbations of that table. Moreover, numerical estimates of the mixing rate of the billiard dynamics on some ergodic tables are also provided.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strong Coupling and Degeneracy Effects in Inertial Confinement Fusion Implosions

Accurate knowledge about the equation of state (EOS) of deuterium is critical to inertial confinement fusion (ICF). Low-adiabat ICF implosions routinely access strongly coupled and degenerate plasma conditions. Using the path integral Monte Carlo method, we have derived a first-principles EOS (FPEOS) table of deuterium. It is the first ab initio EOS table which completely covers typical ICF implosion trajectory in the density and temperature ranges of {rho}=0.002-1596 g/cm{sup 3} and T=1.35 eV-5.5 keV. Discrepancies in internal energy and pressure have been found in strongly coupled and degenerate regimes with respect to SESAME EOS. Hydrodynamics simulations of cryogenic ICF implosions using the FPEOS table have indicated significant differences in peak density, areal density ({rho}R), and neutron yield relative to SESAME simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-54: A New Method for Optimizing Radiation Isocenter for Linac-Based SRS

Purpose: To develop a new method to minimize deviation of linac x-ray beams from the centroid of the volumetric radiation isocenter for all combinations of gantry and table angle. Methods: A set of ball-bearing (Winston-Lutz) images was used to determine the gantry radiation isocenter as the midrange of deviation values. Deviations in the cross-plane direction were minimized by calibration of MLC leaf position offset, and by adjusting beam position steering for each energy. Special attention was also paid to matching the absolute position of isocenter across all energies by adjusting position steering in the gun-target axis. Displacement of table axis from the gantry isocenter, and recommended table axis adjustment for contemporary Elekta linacs, was also determined. Eight images were used to characterize the volumetric isocenter for the full range of gantry and table rotations available. Tabulation of deviation for each beam was used to test compliance with isocenter tolerance. Results: Four contemporary Elekta linacs were evaluated and the radius in the gun-target axis of the radiation isocenter was 0.5 to 0.7 mm. After beam steering adjustment, the radius in the cross-plane direction was typically 0.2 to 0.4 mm. Position matching between energies can be reduced to 0.28 mm. Maximum total deviation was 0.68 to 1.07 mm, depending primarily on the effect of systematic table axis wobble with rotation. Conclusion: This new method effectively facilitates minimization of deviation between beam center and target position. The test, which requires a few minutes to perform, can be easily incorporated into a routine machine QA program. A tighter radiation isocenter for contemporary Elekta linacs would require reducing the effect of gantry arm flex and/or table axis wobble that are the two main components of deviation from the designated isocenter point.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗