Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Storage systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Comparing the economic performance of ice storage and batteries for buildings with on-site PV through model predictive control and optimal sizing

Integrating renewable energy and energy storage systems provides a way of operating the electrical grid system more energy efficiently and stably. Thermal storage and batteries are the most common devices for integration. However, it is not clear which integrated storage system performs better in terms of overall economics. Ice storage has low initial and maintenance costs, but there is an efficiency penalty for charging of storage and it can only shift electrical loads associated with building cooling requirements. A battery's round-trip efficiency, on the contrary, is quite consistent and batteries can be used to shift both HVAC and non-HVAC loads. However, batteries have greater initial costs and a shorter life. Finally, this research presents a tool, using model predictive control and optimal sizing, and provides a case study for comparing life-cycle economics of battery and ice storage systems for commercial buildings that have chillers for cooling and an on-site photovoltaic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of Thermal-Hydraulic Effects of Dry Storage Canister Helium Backfill Loss Using the Horizontal Dry Cask Simulator

A previous investigation produced data sets that can be used to benchmark the codes and best practices presently used to determine cladding temperatures and induced cooling air flows in modern horizontal dry storage systems. The horizontal dry cask simulator (HDCS) was designed to generate this benchmark data and add to the existing knowledge base. The objective of the previous HDCS investigation was to capture the dominant physics of a commercial dry storage system in a well-characterized test apparatus for a wide range of operational parameters. The close coupling between the thermal response of the canister system and the resulting induced cooling air flow rate was of particular importance. The previous investigation explored these parameters using helium backfill at 100 kPa and 800 kPa pressure as well as air backfill with a series of simulated decay heats. The helium tests simulated a horizontal dry cask storage system at normal storage conditions with either atmospheric or elevated backfill pressure, while the air tests simulated horizontal storage canisters following a complete loss of helium backfill, in which case the helium would be replaced by air. The present HDCS investigation adds to the previous investigation by exploring steady-state conditions at various stages of the loss of helium backfill from a horizontal dry cask storage system. This is achieved by using helium/air blends as a backfill in the HDCS and running a series of tests using various simulated decay heats to explore the effects of relative helium/air molar concentration on the thermal response of a simulated horizontal dry cask storage system. A total of twenty tests were conducted where the HDCS achieved steady state for various assembly powers, representative of decay heat. The power levels tested were 0.50, 1.00, 2.50, and 5.00 kW. All tests were run at 100 kPa vessel pressure. The backfill gases used in these tests are given in this report as a function of mole fraction of helium (He), balanced by air: 1.0, 0.9, 0.5, 0.1, and 0.0 He. Steady-state conditions (where the steady-state start condition is defined as where the change in temperature with respect to time for the majority of HDCS components is less than or equal to 0.3 K/h) were achieved for all test cases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Grand challenges in mass storage: A system integrator's perspective

The grand challenges are the following: to develop more innovation in approach; to expand the I/O barrier; to achieve increased volumetric efficiency and incremental cost improvements; to reinforce the 'weakest link' software; to implement improved architectures; and to minimize the impact of self-destructing technologies. Mass storage is defined as any type of storage system exceeding 100 GBytes in total size, under the control of a centralized file management scheme. The topics covered are presented in viewgraph form.

Mintz, Dan↗

Thermal Energy Storage Configurations for Small Modular Reactor Load Shedding

The increased penetration of intermittent renewable energy technologies such as wind and solar power can strain electric grids, forcing carbon-based and nuclear sources of energy to operate in a load follow mode. For nuclear reactors, load follow operation can be undesirable due to the associated thermal and mechanical stresses placed on the fuel and other reactor components. Various methods of Thermal Energy Storage (TES) can be coupled to nuclear (or renewable) power sources to help absorb grid variability caused by daily load demand changes and renewable intermittency. Two TES techniques are investigated as candidate thermal reservoirs to be used in conjunction with a Small Modular Reactor (SMR): a two-tank sensible heat storage system and a stratified chilled-water storage system. The goal when coupling the two systems to the SMR is to match turbine output and demand and bypass steam to the TES systems to maintain reactor power at approximately 100%. Simulations of IPWR dynamics are run in a high-fidelity FORTRAN model developed at NCSU. Both TES systems are developed as callable FORTRAN subroutines to model the time-varying behavior associated with different configurations of these systems when connected to the SMR simulator. Simulation results reveal the sensible heat storage system is capable of meeting turbine demand and maintaining reactor power constant, while providing enough steam to power four absorption chillers for chilled-water production and storage. Here,the stored chilled water is used to supplement cooling loads of an adjacent facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Layout-Aware I/O Scheduling for Terabits Data Movement

Many science facilities, such as the Department of Energy s Leadership Computing Facilities and experimental facilities including the Spallation Neutron Source, Stanford Linear Accelerator Center, and Advanced Photon Source, produce massive amounts of experimental and simulation data. These data are often shared among the facilities and with collaborating institutions. Moving large datasets over the wide- area network (WAN) is a major problem inhibiting collaboration. Next- generation, terabit-networks will help alleviate the problem, however, the parallel storage systems on the end-system hosts at these institutions can become a bottleneck for terabit data movement. The parallel storage system (PFS) is shared by simulation systems, experimental systems, analysis and visualization clusters, in addition to wide-area data movers. These competing uses often induce temporary, but significant, I/O load imbalances on the storage system, which impact the performance of all the users. The problem is a serious concern because some resources are more expensive (e.g. super computers) or have time-critical deadlines (e.g. experimental data from a light source), but parallel file systems handle all requests fairly even if some storage servers are under heavy load. This paper investigates the problem of competing workloads accessing the parallel file system and how the performance of wide-area data movement can be improved in these environments. First, we study the I/O load imbalance problems using actual I/O performance data collected from the Spider storage system at the Oak Ridge Leadership Computing Facility. Second, we present I/O optimization solutions with layout-awareness on end-system hosts for bulk data movement. With our evaluation, we show that our I/O optimization techniques can avoid the I/O congested disk groups, improving storage I/O times on parallel storage systems for terabit data movement.

I/O and Storage↗

Natural Language Query System Design for Interactive Information Storage and Retrieval Systems

The currently developed multi-level language interfaces of information systems are generally designed for experienced users. These interfaces commonly ignore the nature and needs of the largest user group, i.e., casual users. This research identifies the importance of natural language query system research within information storage and retrieval system development; addresses the topics of developing such a query system; and finally, proposes a framework for the development of natural language query systems in order to facilitate the communication between casual users and information storage and retrieval systems.

Dominick, Wayne D.↗

Application of Mobile Energy Storage for Enhancing Power Grid Resilience: A Review

Natural disasters can lead to large-scale power outages, affecting critical infrastructure and causing social and economic damages. These events are exacerbated by climate change, which increases their frequency and magnitude. Improving power grid resilience can help mitigate the damages caused by these events. Mobile energy storage systems, classified as truck-mounted or towable battery storage systems, have recently been considered to enhance distribution grid resilience by providing localized support to critical loads during an outage. Compared to stationary batteries and other energy storage systems, their mobility provides operational flexibility to support geographically dispersed loads across an outage area. This paper provides a comprehensive and critical review of academic literature on mobile energy storage for power system resilience enhancement. As mobile energy storage is often coupled with mobile emergency generators or electric buses, those technologies are also considered in the review. Allocation of these resources for power grid resilience enhancement requires modeling of both the transportation system constraints and the power grid operational constraints. These aspects are discussed, along with a discussion on the cost–benefit analysis of mobile energy resources. The paper concludes by presenting research gaps, associated challenges, and potential future directions to address these challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Evaluation of Energy Storage Cost and Performance Characteristics

The energy storage industry continues to expand globally as costs continue to fall and opportunities in consumer, transportation and grid applications are defined. As the rapid evolution of the industry continues, it has become increasingly important to understand how varying technologies compare in terms of cost and performance. This paper defines and evaluates cost and performance parameters of six battery energy storage technologies (BESS) - lithium-ion batteries, lead-acid batteries, redox flow batteries, sodium-sulfur batteries, sodium metal halide batteries, and zinc-hybrid cathode batteries - four non-BESS storage technologies - pumped storage hydropower, flywheels, compressed air energy storage, and ultracapacitors - and combustion turbines. Cost and performance information was compiled based on an extensive literature review, conversations with vendors and stakeholders, and costs of systems procured at sites across the United States. Detailed cost and performance estimates are presented for 2018 and projected out to 2025. Annualized costs were also calculated for each technology.

Mongird, Kendall↗

Lignin-derived electrochemical energy materials and systems

Electrochemical energy storage systems such as supercapacitors, rechargeable batteries and fuel cells have been proven the most effective technologies for energy conversion, storage, and management at different scales. Although a large number of electrochemical energy technologies have been developed in the past and they will continue to be optimized in terms of cost, lifetime, and performance, there is a substantial growing demand for advanced electrochemical energy systems. To deploy these advanced systems, the electrode and electrolyte materials with higher performance, longer life, and lower cost, must be developed. Lignin is the second most abundant natural polymer after cellulose, a byproduct from emerging cellulosic biorefineries, and a waste product from pulp and paper industries. Numerous researches have successfully demonstrated that lignin from different sources can be used as precursors or feedstocks for preparing high-performance electrochemical energy materials and components such as electrodes, electrolytes, membrane separators, and additives. Moreover, techno-economic analyses indicate that it is possible to prepare cost-effective carbons from lignin at engineering scales, compared to current carbon products. These facts suggest that scalable conversion of lignin into high-value energy materials will offer a promising pathway to not only promote the utilization and valorization of lignin but also boost the development of the advanced electrochemical energy systems. This review presents state of the arts of renewable energy materials derived from various lignin and their applications in electrochemical energy systems with emphasis on supercapacitors, rechargeable batteries, and fuel cells. Meanwhile, this article also aims to carve out the critical barriers for lignin-derived high-performance materials for energy applications, intending to identify viable approaches for synthesis of sustainable new energy materials.

09 BIOMASS FUELS↗

CERF: IM3 Projected Western US Power Plant Locations

Overview The Capacity Expansion Regional Feasibility (CERF) model is an open-source geospatial python package that provides new power plant locations at a 1km resolution. The model ingests U.S. state or regional-scale electricity system capacity expansion plans, such as those produced by the Global Change Analysis Model (GCAM-USA), and identifies feasible, site-specific locations for individual new power plants (renewable and non-renewable). CERF combines high-resolution geospatial suitability analyses with an economic algorithm that selects individual plant siting locations based on grid interconnection costs and the locational marginal value of new generation. The model incorporates a wide range of dynamic constraints and opportunities, such as protected lands, population density, existing infrastructure, and water availability. This dataset provides CERF power plant siting results for IM3 Phase 2 simulations across eight different scenarios for the Western US through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see, https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 CERF siting results in this dataset correspond to capacity expansion plans in the GCAM-USA IM3 Phase 2 simulation data and are available for each of the above scenarios. Data Details Temporal Range: 2015-2055 in 5-year timesteps. Note that 2015 is the experiment base year and 2020 and beyond represent model simulation years. Spatial Range: Plant locations are provided for the eleven states in the Western US including Arizona, California, Colorado, Idaho, Montana, New Mexico, Nevada, Oregon, Utah, Washington, and Wyoming. Spatial Resolution: 1 km-squared, provided in x and y coordinates Geospatial Projection: Albers Equal Area Conic (ESRI:102003) File Type: csv The dataset contains subdirectories for each of the eight scenarios described in the overview. Each scenario folder contains two subfolders with the following information: 1. Power Plant Data This directory contains a single .csv file of power plant locations for both pre-existing (non-CERF sited plants in operation in 2015) and new (CERF-sited) power plants across the temporal range along with additional CERF model output parameters for CERF-sited plants. Plant with a siting year earlier than 2020 correspond to facilities that are operational leading into the first timestep CERF simulation. For a more detailed description of CERF model output parameters, see the CERF model documentation. Note that the cerf_plant_id parameter is unique within each scenario file but not across scenario files. Parameter Descriptions scenario - Name of scenario cerf_plant_id - Unique siting identifier cerf_sited - If True, indicates that plant was sited by CERF model. If False, indicates pre-existing facility region_name - Name of region (state) tech_id - Technology ID tech_name - Full generation technology name inclusive of cooling type (if applicable) and additional characteristics tech_simple - Simplified generation technology type unit_size_mw - Power plant unit size (MW) xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) index - Index position in the flattend 2D array buffer_in_km - Exclusion buffer around site (km) sited_year - Year of siting retirement_year - Year of retirement lmp_zone - Locational marginal price (LMP) zone ID locational_marginal_price_usd_per_mwh - Locational marginal price ($/MWh) generation_mwh_per_year - Generation output (MWh/yr) operating_cost_usd_per_year - Cost of plant operations ($/yr) net_operational_value - Net operational value based on LMP and and operating costs ($/yr) interconnection_cost - Cost of interconnection for transmission & gas pipeline (if applicable) net_locational_cost -- Difference of interconnection cost and operating value ($/yr) capacity_factor_fraction - Capacity factor (fraction) carbon_capture_rate_fraction - Carbon capture rate (fraction) fuel_co2_content_tons_per_btu - Fuel CO2 content (tons/Btu) fuel_price_usd_per_mmbtu - Fuel price ($/MMBtu) fuel_price_esc_rate_fraction - Fuel price escalation rate (fraction) heat_rate_btu_per_kWh - Heat rate (Btu/kWh) lifetime_yrs - Technology lifetime for annuity (years) operational_life_yrs - Operational lifetime for retirement (years) variable_om_usd_per_mwh - Variable operation and maintenance costs of yearly capacity use ($/MWh) variable_om_esc_rate_fraction - Variable operation and maintenance costs escalation rate (fraction) carbon_tax_usd_per_ton - Carbon tax ($/ton) carbon_tax_esc_rate_fraction - Carbon tax escalation rate (fraction) 2. Storage Data This directory contains information on new and pre-existing energy storage facilities operational in each timestep along with various storage operational parameters. The 2015 timestep provides pre-existing energy storage data and corresponds with facilities that are operational leading into the first model simulation timestep. Note that coordinates in the storage files correspond to the interconnection point on the grid (substation location), not individual energy storage locations. Energy storage is added in a cumulative process at each given interconnection point. That is, each individual file provides the total operational storage capacity interconnected to the specified substation for the given timestep, inclusive of previously installed storage at that location and new storage installed in that timestep at that location. Parameters scenario - Name of scenario timestep - Simulation timestep name - Unique storage identifier s_typ - Type of energy storage technology (battery or pumped storage hydro) s_node - Node ID of interconnecting substation xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) charge_rate - Maximum charge rate (power capacity) of storage system (MW) discharge_rate - Maximum discharge rate (power capacity) of storage system (MW) duration - Duration of storage system (hours) max_SoC - Allowed maximum state of charge (energy capacity) of storage system (MWh) min_SoC -Allowed minimum state of charge (energy capacity) of storage system (MWh) charge_eff - Efficiency of charge (fraction between 0 and 1) discharge_eff - Efficiency of discharge (fraction between 0 and 1) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

CERF↗

Modular Undersea Compressed Air Energy Storage (UCAES) System

This project has been devoted to the design, optimization, and cost analysis of a unique power plant with integral energy storage. The proposed facility combines a novel underwater compressed air energy storage (UCAES) system with a customized gas turbine generator, providing exceptional power management and overall efficiency. Unlike conventional CAES, opportunities for underwater storage are plentiful and proximal to the power grid. The UCAES system provides coastal and island communities a practical means for managing the volatility of large-scale wind and solar power resources. The result is higher renewable energy absorption and improved electrical reliability with reduced fossil fuel consumption. The UCAES power plant is composed of three major subsystems: The underwater air containment system (ACS), the air transport pipe (ATP), and the land-based power conversion system (PCS). The underwater ACS is made up of modular concrete shell units, structurally optimized for minimal material usage while employing conventional production methods and equipment. Each shell is designed to receive and control loose fill or gravel, serving as the ballast. The static nature of the final structures make them an asset to marine habitats and includes features intended to permit safe and cost-effective deployment. The ATP Connects the ACS modules to each other and to the on-land power conversion system and utilizes high density polyethylene (HDPE) pipe for low cost and long life. The PCS Houses the turbine-generator ‘expander modules’, with peak capacity of 12.3 MWe each, engineered from existing gas turbine equipment and includes electrically driven commercial 3-stage intercooled centrifugal compressors, each nominally drawing 6.6 MWe when matching the turbine flow requirements. The subsystems listed above are designed with the intent to serve as building-blocks to achieve a peak power output rating in the 40 to 120 MWe range, with 0.25 to 4 hours of energy storage capacity. The modular facility with integral energy storage provides some remarkable transient maneuvers and load-following features unachievable by competing technologies. The system can operate as a dispatchable power plant with a fuel-to-electric efficiency over 41%; substantially better that the average existing Hawaiian peak power generation assets. Optimal efficiency can be maintained while load-following due to modular PCS design and is operable with a range of liquid or gaseous fuels while meeting the most stringent California (CARB) emission standards. The system can operate as a peaking energy plant in discharge mode. Power ramp-up equivalent to 215% of continuous load rating within 1 second accomplished by simply turning off the electric compressor(s). Contrarily, the system can offer energy absorption during periods of grid surplus generation. The electric compressors may be sequenced on to absorb power within seconds. More moderate transitions are easily achieved with standard compressor control functions. The system offers unique features as compared to energy storage systems. ‘Round-trip efficiency’, as calculated by industry standard methods, is in the 90% range. The PCS equipment has a mean-time between overhauls of 80,000 hours, with maintenance costs of less than $0.005/kW-hr of electricity delivered. The underwater ACS structures and piping employ materials and designs specified to achieve a 75 year life. With the underwater containment modules qualified as a marine habitat, there would be no decommissioning costs. In conjunction with the engineering work invested in the design of the UCAES power plant, Brayton Energy has employed a team of manufacturing specialists, marine construction engineers, and power industry experts to create a comprehensive economic model that captures the many site-related variables and configuration options. The cost results and methodology have been validated by suppliers, engineers, and deployment specialists through a detailed case study on Hawaii. While creation of the parametric cost model was based on inputs specific to Hawaii, the proposed construction and deployment steps were chosen to be general enough to allow extrapolation across locations world-wide. Analysis of the proposed system shows it to be a viable option and addresses the principal challenges described by the Department of Energy by offering competitive costs, validated safety and reliability, consideration of the regulatory environment, and utilization of industry accepted practices and equipment. The UCAES system is recommended for immediate consideration in Hawaii. Estimation of time to complete planning, design, and construction of the facility is anticipated to take 3 to 5 years. Other coastal and island communities world-wide should realize similar benefits; as the results presented in this report are considered generally transferable to other locations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of the Back End of the Nuclear Fuel Cycle

Management of spent nuclear fuel and high-level radioactive waste consists of three main phases – storage, transportation, and disposal – commonly referred to as the back end of the nuclear fuel cycle. Current practice for commercial spent nuclear fuel management in the United States (US) includes temporary storage of spent fuel in both pools and dry storage systems at operating or shutdown nuclear power plants. Storage pools are filling to their operational capacity, and management of the approximately 2,200 metric tons of spent fuel newly discharged each year requires transferring older and cooler spent fuel from pools into dry storage. Unless a repository becomes available that can accept spent fuel for permanent disposal, projections indicate that the US will have approximately 136,000 metric tons of spent fuel in dry storage systems by mid-century, when the last plants in the current reactor fleet are decommissioned. Current designs for dry storage systems rely on large multi-assembly canisters, the most common of which are so-called “dual-purpose canisters” (DPCs). DPCs are certified for both storage and transportation, but are not designed or licensed for permanent disposal. The large capacity (greater number of spent fuel assemblies) of these canisters can lead to higher canister temperatures, which can delay transportation and/or complicate disposal. This current management practice, in which the utilities continue loading an ever-increasing inventory of larger DPCs, does not emphasize integration among storage, transportation, and disposal. This lack of integration does not cause safety issues, but it does lead to a suboptimal system that increases costs, complicates storage and transportation operations, and limits options for permanent disposal. This paper describes strategies for improving integration of management practices in the US across the entire back end of the nuclear fuel cycle. The complex interactions between storage, transportation, and disposal make a single optimal solution unlikely. However, efforts to integrate various phases of nuclear waste management can have the greatest impact if they begin promptly and continue to evolve throughout the remaining life of the current fuel cycle. A key factor that influences the path forward for integration of nuclear waste management practices is the identification of the timing and location for a repository. The most cost-effective path forward would be to open a repository by mid-century with the capability to directly dispose of DPCs without repackaging the spent fuel into disposalready canisters. Options that involve repackaging of spent fuel from DPCs into disposalready canisters or that delay the repository opening significantly beyond mid-century could add 10s of billions of dollars to the total system life cycle cost.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Overview of the Geoanalytical Economic Evaluation of Saline Storage (GEESS) System

This report provides an overview on the Geoanalytical Economic Evaluation of Saline Storage (GEESS) system which characterized 57 geologic saline formations targeted for geologic carbon storage across the lower-48 U.S. states using publicly available resources. The GEESS system consists of high spatial resolution datasets (up to 5 km grid spacing) that provide key geologic parameters (e.g., depth, thickness, permeability), and estimates of CO 2 plume size and CO 2 first-year break-even price that were determined by exercising GEESS data through the FECM/NETL CO 2 Saline Storage Cost Model (CO2_S_COM). The GEESS geodatabase is available on NETL’s EDX at GEESS Geodatabase.

54 ENVIRONMENTAL SCIENCES↗

Apparatus and method for use in storing energy

Some embodiments provide energy storage systems that comprise: a first electrode; a second electrode; an electrolyte; the first electrode, the second electrode and the electrolyte are positioned such that the electrolyte is in contact with at least the first electrode; and a polarity reversal system electrically coupled with the first electrode and the second electrode, wherein the polarity reversal system is configured to allow the energy storage system to operate while a first polarity to charge and discharge electrical energy while operating in the first polarity, and the polarity reversal system is configured to reverse the voltage polarity across the first and second electrodes to a second polarity to allow the energy storage system to continue to operate while the second polarity is established across the first electrode and the second electrode to continue to charge and discharge electrical energy while operating in the second polarity.

25 ENERGY STORAGE↗

A Long-Cycle-Life Lithium-CO{sub 2} Battery with Carbon Neutrality.

Lithium-CO2 batteries are attractive energy-storage systems for fulfilling the demand of future large-scale applications such as electric vehicles due to their high specific energy density. However, a major challenge with Li-CO2 batteries is to attain reversible formation and decomposition of the Li2CO3 and carbon discharge products. A fully reversible Li-CO2 battery is developed with overall carbon neutrality using MoS2 nanoflakes as a cathode catalyst combined with an ionic liquid/dimethyl sulfoxide electrolyte. This combination of materials produces a multicomponent composite (Li2CO3/C) product. The battery shows a superior long cycle life of 500 for a fixed 500 mAh g(-1) capacity per cycle, far exceeding the best cycling stability reported in Li-CO2 batteries. The long cycle life demonstrates that chemical transformations, making and breaking covalent C-O bonds can be used in energy-storage systems. Theoretical calculations are used to deduce a mechanism for the reversible discharge/charge processes and explain how the carbon interface with Li2CO3 provides the electronic conduction needed for the oxidation of Li2CO3 and carbon to generate the CO2 on charge. This achievement paves the way for the use of CO2 in advanced energy-storage systems.

carbon neutrality↗

Economic Comparison Between a Battery and Supercapacitor for Hourly Dispatching Wave Energy Converter Power: Preprint

This paper demonstrates a successful dispatching scheme of slider-crank wave energy converter (WEC) production using two different kinds of energy storage systems, namely, (i) Li-ion battery and (ii) Supercapacitors (SC). The performance of two energy storage systems has been compared in order to develop the most economical energy storage system for WEC hourly dispatching scheme. The cost optimization of the energy storage system considering both cycling and calendar aging expenses is made based on its usage of depth of discharge (DOD). In this study, the extensive simulation is conducted in MATLAB/Simulink platform, and it is found that SC is a better candidate than Li-ion battery in terms of economic assessment for hourly dispatching WEC power.

50 EE - Wind and Water Power Program - Water (EE-4↗

Integrated Solutions for Interim Used Fuel Management: From Pool Unloading to Safe Delivery to Recycling or Repository Facilities - 17235

Safe management of used nuclear fuel (UNF) is key to the survival of the nuclear industry. That is why it is more important than ever to have a consent-based, practical, credible, and sustainable roadmap for managing the back-end of the nuclear cycle. Worldwide UNF Light Water Reactors (LWR) inventories are currently around 200,000 tons and are estimated to grow to more than 350,000 tons by 2030, and operating nuclear reactors in the U.S. continue to discharge UNF every 18 to 24 months. International experience has demonstrated that the development of a permanent geological repository can be a multi-decade process, especially in the face of public acceptance challenges. Meanwhile, the solution for permanent disposal of UNF in the U.S. is moving at a glacial pace. As a result, industrial stakeholders have been forced to find practical interim UNF storage solutions in order to continue safely operating their reactors. Among those interim solutions are the cask- or canister-based dry storage systems that have dramatically increased in the last 10 years as they provide flexibility for expansion with a low up-front investment. With interim dry storage in place for more than 30 years, our industry is entering a new phase as we are forced to prepare for a few more decades before geological repositories begin operating. Consequently, interim dry storage has to be extended for 80 years or more. Thus, new considerations have to be taken into account to ensure the safety of this stored used fuel: - Interim storage systems are aging; - High burn-up fuel behavior overtime is uncertain; - Used fuel is losing its self-protection; - The number of shutdown sites without a fuel transfer facility, such as a pool, is increasing; - Some owners of Independent Spent Fuel Storage installation (ISFSI) at shutdown sites are not nuclear operators anymore. With increasing uncertainties, AREVA TN -- based on its long expertise with used fuel transportation and interim storage systems -- is adapting its portfolio to develop integrated and flexible solutions that will remove the burden of interim used fuel management from nuclear operators. AREVA TN is developing comprehensive solutions to reduce risks including the continued supply of proven safe high-performance dry storage systems; on-site services to safely transfer used fuel from pool to pad; the optimization of fuel heat load in the storage pool and pad; innovative aging management services including inspection, monitoring and repair; a realistic solution for consolidated interim storage with a priority to remove Used Nuclear Fuel stored in dry storage systems from shutdown sites; world-class transport and logistics services to safely move the used fuel from nuclear reactor sites to consolidated storage and repository or recycling as applicable, and turnkey management of shutdown ISFSIs. Due to the lack of an available path for transporting used fuel away from reactors, nuclear operators are faced with many challenges and growing uncertainties. Our presentation will describe the practical solutions developed and being developed in order to manage used fuel on behalf of nuclear operators and allows them to continue focusing on the important job of producing carbon-free clean energy. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Layout-aware I/O Scheduling for terabits data movement

Many science facilities, such as the Department of Energy's Leadership Computing Facilities and experimental facilities including the Spallation Neutron Source, Stanford Linear Accelerator Center, and Advanced Photon Source, produce massive amounts of experimental and simulation data. These data are often shared among the facilities and with collaborating institutions. Moving large datasets over the wide-area network (WAN) is a major problem inhibiting collaboration. Next-generation, terabit-networks will help alleviate the problem, however, the parallel storage systems on the endsystem hosts at these institutions can become a bottleneck for terabit data movement. The parallel storage system (PFS) is shared by simulation systems, experimental systems, analysis and visualization clusters, in addition to wide-area data movers. These competing uses often induce temporary, but significant, I/O load imbalances on the storage system, which impact the performance of all the users. The problem is a serious concern because some resources are more expensive (e.g. super computers) or have time-critical deadlines (e.g. experimental data from a light source), but parallel file systems handle all requests fairly even if some storage servers are under heavy load. This paper investigates the problem of competing workloads accessing the parallel file system and how the performance of wide-area data movement can be improved in these environments. First, we study the I/O load imbalance problems using actual I/O performance data collected from the Spider storage system at the Oak Ridge Leadership Computing Facility. Second, we present I/O optimization solutions with layout-awareness on end-system hosts for bulk data movement. With our evaluation, we show that our I/O optimization techniques can avoid the I/O congested disk groups, improving storage I/O times on parallel storage systems for terabit data movement.

Kim, Youngjae↗